Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling and trapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Ion Trapping Studies and Mitigation Strategies for the EIC ERL-Based Strong Hadron Cooler

An Energy Recovery Linac based strong hadron cooler was previously considered for the Electron-Ion Collider. The required electron beam parameters for variable-energy strong hadron cooling place significant constraints on ion trapping and collective effects. This paper presents initial studies of these constraints through a combination of analytical modelling and numerical simulations of ion production, trapping behaviour, and mitigation strategies. A multi-bunch tracking framework based on ELEGANT with the ionEffects module is used to simulate machine operation over millisecond time scales, corresponding to more than 3 × 10^5 electron bunches. The simulations include modelling of ionisation processes together with transverse electron–ion dynamics, allowing the evolution and accumulation of ions to be investigated. Analytical expressions based on Gaussian beam distributions are used to estimate ion trapping conditions and benchmark the simulation results. A bi-periodic bunch spacing scheme is also investigated as a possible mitigation method by detuning the ion oscillation frequency. These studies provide an initial assessment of ion trapping in the strong hadron cooler and demonstrate possible approaches for reducing beam–ion effects.

Bi, R. [Lancaster University, Cockcroft Institute]↗

A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Galactic oscillations

Several oscillations have been identified in spherical galaxy models. These are normal mode oscillations in a stable galaxy. Each has its own distinct period and spatial form, and each rings without detectable damping through a Hubble time. The most important are: (1) a simple radial pulsation (fundamental mode), in which all parts of the galaxy move inward or outward with the same phase; and (2) a second spherically symmetrical radial mode with one node, so material inside the node moves outward when material outside moves inward. Numerical experiments suggest that normal mode oscillations may be present in nearly all galaxies at a considerably higher amplitude than has previously been thought. Amplitudes typically run a few percent of equilibrium values, and periods are around 50-300 Myrs in typical galaxies. These time scales are long enough that gas trapped near the center could cool during an oscillation cycle, allowing star formation activity. The second mode oscillations could cause bursts of star formation.

Smith, B. F.↗

Numerical simulations of three-dimensional ion crystal dynamics in a Penning trap using the fast multipole method

We simulate the dynamics, including laser cooling, of three-dimensional (3-D) ion crystals confined in a Penning trap using a newly developed molecular dynamics-like code. The numerical integration of the ions’ equations of motion is accelerated using the fast multipole method to calculate the Coulomb interaction between ions, which allows us to efficiently study large ion crystals with thousands of ions. In particular, we show that the simulation time scales linearly with ion number, rather than with the square of the ion number. By treating the ions’ absorption of photons as a Poisson process, we simulate individual photon scattering events to study laser cooling of 3-D ellipsoidal ion crystals. Initial simulations suggest that these crystals can be efficiently cooled to ultracold temperatures, aided by the mixing of the easily cooled axial motional modes with the low frequency planar modes. In our simulations of a spherical crystal of 1000 ions, the planar kinetic energy is cooled to several millikelvin in a few milliseconds while the axial kinetic energy and total potential energy are cooled even further. This suggests that 3-D ion crystals could be well suited as platforms for future quantum science experiments.

Zaris, John (ORCID:0009000196476323)↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

The Effect of Inverse Compton Losses on Particle Acceleration in Three-dimensional Relativistic Reconnection

Relativistic magnetic reconnection is a key mechanism for dissipating magnetic energy and accelerating particles in astrophysics. In the absence of radiative cooling, recent particle-in-cell (PIC) simulations have shown that high-energy particles gain most of their energy in the upstream region, during a short-lived “free phase” where they meander between the two sides of the layer; when they get captured/trapped by the downstream flux ropes, they undergo a “trapped phase,” where no significant energization occurs. Here, we perform a suite of 3D PIC simulations of relativistic reconnection, including inverse Compton (IC) losses in the weakly cooled regime in which the radiation-reaction-limited Lorentz factor γrad exceeds the magnetization σ. We show that electron cooling losses do not appreciably alter the reconnection rate, the structure of the layer, and the physics of particle acceleration in the free phase, so the spectrum of free electrons is dN free /dγ ∝ γ −1 , as in the uncooled case. The spectrum of trapped electrons above the cooling break γcool (in the range γ cool < γ < γ rad ) is dN/dγ ∝ γ −3 , steeper than the scaling dN/dγ ∝ γ −2 of uncooled simulations. This confirms that no significant particle energization occurs during the trapped phase. Our results validate the model by Zhang et al. for particle acceleration in 3D relativistic reconnection, and imply that radiative emission models of reconnection-powered astrophysical sources should employ a two-zone structure that differentiates between free, rapidly accelerating particles and trapped, passively cooling particles.

79 ASTRONOMY AND ASTROPHYSICS↗

The effect of inverse Compton losses on particle acceleration in three-dimensional relativistic reconnection

Relativistic magnetic reconnection is a key mechanism for dissipating magnetic energy and accelerating particles in astrophysics. In the absence of radiative cooling, recent particle-in-cell (PIC) simulations have shown that high-energy particles gain most of their energy in the upstream region, during a short-lived "free phase" where they meander between the two sides of the layer; when they get captured/trapped by the downstream flux ropes, they undergo a "trapped phase", where no significant energization occurs. Here, we perform a suite of 3D PIC simulations of relativistic reconnection including inverse Compton (IC) losses in the weakly cooled regime in which the radiation-reaction-limited Lorentz factor $γ_{\rm rad}$ exceeds the magnetization $σ$. We show that electron cooling losses do not appreciably alter the reconnection rate, the structure of the layer, and the physics of particle acceleration in the free phase, so the spectrum of free electrons is $dN_{\rm free}/dγ\propto γ^{-1}$, as in the uncooled case. The spectrum of trapped electrons above the cooling break $γ_{\rm cool}$ (in the range $γ_{\rm cool}<γ<γ_{\rm rad}$) is $dN/dγ\propto γ^{-3}$, steeper than the scaling $dN/dγ\propto γ^{-2}$ of uncooled simulations. This confirms that no significant particle energization occurs during the trapped phase. Our results validate the model by arXiv:2302.12269 for particle acceleration in 3D relativistic reconnection, and imply that radiative emission models of reconnection-powered astrophysical sources should employ a two-zone structure, that differentiates between free, rapidly accelerating particles and trapped, passively cooling particles.

FOS: Physical sciences↗

Development of High-efficiency and Cost-effective Forged Ingot Niobium Technology for Science Frontiers and Accelerator Applications

Development of Forged Ingot Niobium Technology: Worlds science frontier programs and SRF accelerator applications demand high performance and cost-effective SRF accelerator technology [1-8]. Fine-grain (FG) and Large-grain (LG) ingot niobium technologies have been very well developed and implemented in all the present-day accelerator projects. However, forged ingot niobium technology which is the focus of this development proposal will be much more cost-effective and expected to have several technical advantages. FG niobium sheet production is very complex involving more than ten processing steps making them prone to contamination. As a result, they are very expensive to produce and require stringent QA procedure to be ready for SRF cavity production. The accelerating cavity process steps are also numerous and require strict procedures in order to achieve high accelerating gradients and quality factors needed for science frontier programs. LG niobium disc production, directly sliced from the ingot, is relatively simple and straight forward to keep surface cleanness. The disc production cost is significantly low compared to FG niobium sheet production. However, there are (some) draw backs due to non-homogeneity of the grain boundary distribution, resulting in non-uniform mechanical properties and complex cavity fabrication, although the LG cavities achieve the expected high-gradient performance goals with lower cost. Medium-grain (MG) niobium disk production may be realized with a new approach/process, the disc directly sliced from the forged ingot, involves a simpler process steps contributing major production cost reduction [9]. These discs are expected to be superior as they tend to be homogenous with uniform sub millimeter grains and mechanical properties. We are eagerly looking forward to developing the forged ingot niobium SRF accelerator technology for the benefit of the world-wide science frontier programs, green energy subcritical nuclear energy systems and a wide variety of industrial applications including the production of radio isotopes and nuclear transmutation applications. Measurement of thermal characteristics of the forged ingot niobium: Measurement of the thermal diffusivity, D, of superconducting MG niobium is important to be understood in comparison with FG sheet and LG disc, as well as that of advanced composite material of Nb3Sn film sputtered on forged ingot Nb, which will be determined using transient pump-probe thermo-modulation [10,11]. Transient thermo-modulation is based on using an ultrafast laser pulse to heat the superconducting materials by a few K, then a synchronized laser pulse probes the reflectance of the heated material. For thin films on a substrate (e.g, 100-nm Nb3Sn on Nb), it takes <100 ps for the heat to reach the substrate by diffusion. Therefore, an ultrafast method is needed to probe D of the studied material. D will be measured from room temperature to liquid helium temperatures. Fundamental Research: The increase of rf loss in SRF cavities is related to trapping of residual magnetic field during the cavity cool-down. The study suggested that the micro structure plays the role in flux trapping sensitivity. The research includes the flux trapping and expulsion study as forged ingot niobium goes through several mechanical deformations, crystallization leading to the optimal SRF cavity performance. Furthermore, the cavity made from FG, MG, and LG sheet/disc will be compared to understand the optimal re-crystallization temperature that cavity needed to be heat treated which minimize the flux trapping and increase SRF cavity performance. References: 1. S. Belomestnykh, Overview of recent SRF developments for ERLs, presented at the SRF 2015, Whistler, BC, Canada (2015). 2. A. Yamamoto, M. Yamanaka and G. Myneni, Ingot Nb based SRF Technology for the International Linear Collider, in Science and Technology of Ingot Niobium for Superconducting Radio Frequency Applications, AIP Conf. Proc. 1687, 030005-1 ? 03005-6, 2015 3. Report of the Workshop on Energy and Environmental Applications of Accelerators, DOE Workshop Report. https://science.osti.gov/-/media/hep/pdf/Reports/2020/CASM_WorkshopReport.pdf? la=en&hash=AEB0B318ED0436B1C5FF4EE0FDD6DEB84C2F15B2 4. G. Ciovati, et al., Design of a cw, low-energy, high-power superconducting linac for environmental applications, Phys. Rev. Accel. Beams 21, 091601 (2018). 5. P. Dhakal, et al., Effect of high temperature heat treatments on the quality factor of a large-grain superconducting radio-frequency niobium cavity, Phys. Rev. ST Accel. Beams 16, 042001 (2013). 6. P. Kneisel et al., Review of ingot niobium as a material for superconducting radio frequency accelerating cavities, Nuclear Instruments and Methods in Physics Research A 774, 133 (2015). 7. G. Ciovati, P. Dhakal, and G. R, Myneni, Superconducting radio-frequency cavities made from medium and low-purity niobium ingots, Supercond. Sci. Technol. 29, 064002 (2016). 8. M. Drury et al., commissioning of the prototype C75 cavities in a CEBAF cryomodule, in Proc. of IPAC 2018, Vancouver, BC, Canada (2018) 9. Feasibility of forged-ingot niobium disc and SRF cavity fabrication technology recently demonstrated in cooperation of ATI, BSCE, and KEK (2020). 10. Hani E. Elsayed-Ali, ?Measurements of heat transport in thin films by ultrafast laser-based techniques,? 3rd International Conference on Thermal Issues in Emerging Technologies Theory and Applications, Cairo, Egypt, pp. 347 ? 350 (2010). DOI: 10.1109/ThETA17616.2010 11. W. M. G. Ibrahim, H. E. Elsayed-Ali, M. Schinn, and C. A. Bonner, Jr., ?Ultrafast investigation of electron dynamics in multilayer metals,? Int. J. Heat and Mass Transfer, 47(10?11), 2261?2268 (2004).

Myneni, G.↗

A Transportable Gravity Gradiometer Based on Atom Interferometry

A transportable atom interferometer-based gravity gradiometer has been developed at JPL to carry out measurements of Earth's gravity field at ever finer spatial resolutions, and to facilitate high-resolution monitoring of temporal variations in the gravity field from ground- and flight-based platforms. Existing satellite-based gravity missions such as CHAMP and GRACE measure the gravity field via precise monitoring of the motion of the satellites; i.e. the satellites themselves function as test masses. JPL's quantum gravity gradiometer employs a quantum phase measurement technique, similar to that employed in atomic clocks, made possible by recent advances in laser cooling and manipulation of atoms. This measurement technique is based on atomwave interferometry, and individual laser-cooled atoms are used as drag-free test masses. The quantum gravity gradiometer employs two identical atom interferometers as precision accelerometers to measure the difference in gravitational acceleration between two points (Figure 1). By using the same lasers for the manipulation of atoms in both interferometers, the accelerometers have a common reference frame and non-inertial accelerations are effectively rejected as common mode noise in the differential measurement of the gravity gradient. As a result, the dual atom interferometer-based gravity gradiometer allows gravity measurements on a moving platform, while achieving the same long-term stability of the best atomic clocks. In the laboratory-based prototype (Figure 2), the cesium atoms used in each atom interferometer are initially collected and cooled in two separate magneto-optic traps (MOTs). Each MOT, consisting of three orthogonal pairs of counter-propagating laser beams centered on a quadrupole magnetic field, collects up to 10(exp 9) atoms. These atoms are then launched vertically as in an atom fountain by switching off the magnetic field and introducing a slight frequency shift between pairs of lasers to create a moving rest frame for the trapped atoms. While still in this moving-frame molasses, the laser frequencies are further detuned from the atomic resonance (while maintaining this relative frequency shift) to cool the atom cloud's temperature to 2 K or below, corresponding to an rms velocity of less than 2 cm/s. After launch, the cold atoms undergo further state and velocity selection to prepare for atom interferometry. The atom interferometers are then realized using laser-induced stimulated Raman transitions to perform the necessary manipulations of each atom, and the resulting interferometer phase is measured using laser-induced fluorescence for state-normalized detection. More than 20 laser beams with independent controls of frequency, phase, and intensity are required for this measurement sequence. This instrument can facilitate the study of Earth's gravitational field from surface and air vehicles, as well as from space by allowing gravity mapping from a low-cost, single spacecraft mission. In addition, the operation of atom interferometer-based instruments in space offers greater sensitivity than is possible in terrestrial instruments due to the much longer interrogation times available in the microgravity environment. A space-based quantum gravity gradiometer has the potential to achieve sensitivities similar to the GRACE mission at long spatial wavelengths, and will also have resolution similar to GOCE for measurement at shorter length scales.

Yu, Nan↗

Method and apparatus for producing microshells

A method is described for forming hollow particles, or shells, of extremely small size. The shell material is heated to a molten temperature in the presence of a gas that is at least moderately soluble in the shell material, to form a solution of the molten shell material and the soluble gas. The solution is atomized to form a multiplicity of separate droplets that are cooled while in free fall. Cooling of a droplet from the outside traps the desolved gas and forces it to form a gas bubble at the center of the droplet which now forms a gas filled shell. The shell is reheated and then cooled in free fall, in an environment having a lower pressure than the gas pressure in the shell. This causes expansion of the shell and the formation of a shell having a small wall thickness compared to its diameter.

Lee, Mark C.↗

Modelling pulsed field magnetization of iron-based bulk superconductors

Abstract Bulk superconductors can be used as super-strength quasi-permanent magnets capable of providing magnetic flux densities considerably superior to conventional permanent magnets. This makes them attractive for several engineering applications that rely on strong magnetic fields like rotating machines, NMR/MRI and magnetic drug delivery systems. Recently, the authors reported a record trapped magnetic field in an iron-based bulk superconductor: 2.83 T was trapped in potassium-doped barium iron arsenide (Ba, K)Fe 2 As 2 (or Ba122) at 5 K. Of particular significance is that the strength and temporal stability of this magnetic field exceeds the requirements of MRI machines, indicating iron-based bulks can now perform at levels demanded by engineering applications. One crucial challenge for their practical use, however, is the need to apply and remove an external magnetic field to magnetize them. Pulsed field magnetization (PFM) shows great promise as a practical method of magnetizing bulks, but the process generates heat in the bulk that is detrimental to its superconducting performance and ability to act as a super-strength magnet. In this paper, coupled electromagnetic–thermal numerical models are used to simulate the PFM of iron-based bulk superconductors. Here we focus on the recent-record-breaking, fine-grain polycrystalline K-doped Ba122 bulks. The impact that the specific J c ( B ) characteristics and thermal properties of the Ba122 material—all of which have been experimentally measured from state-of-the-art samples—have on the magnetic flux dynamics and thermal behaviour during PFM, including the final trapped field, is investigated. We show that because the thermal properties are similar to those of REBa 2 Cu 3 O 7 −δ bulks, a similar response to pulsed fields is obtained. A maximum trapped field of ∼0.81 T (∼43.3% of the maximum trapped field capability under ideal, field-cooling conditions) was simulated at 5 K, with a magnetization efficiency of ∼54%. The modelling framework provides a fast and flexible tool for optimising the practical PFM process at different operating temperatures to maximise the trapped field in state-of-the-art Ba122 bulks and to guide the design of future experiments.

bulk superconductors↗

Ion energy distribution in an electron beam ion trap inferred from simulations of the trapped ion cloud

For this work, we have inferred the energy distribution of trapped ions in an electron beam ion trap (EBIT) from simulations of the spatial distribution of Fe 13+ ions and a comparison with measured visible light images of the ion cloud. We simulated the cloud of Fe 13+ ions by computing ion trajectories in the EBIT for different ion energy distributions used to initialize the trajectories. We then performed a least-squares fit to infer the ion energy distribution that best reproduced the measured ion cloud. These best-fit distributions were typically non-Maxwellian. For electron beam energies of 395–475 eV and electron beam currents of 1–9 mA, we find that the average ion energy is in the range of 10–300 eV. We also find that the average ion energy increases with increasing beam current approximately as $\langle$E$\rangle$ ≈ 25 I e eV, where I e is the electron beam current in mA. We have also compared our results to Maxwell-Boltzmann-distribution ion clouds. We find that our best-fit non-thermal distributions have an $\langle$E$\rangle$ that is less than half that of the T from the best-fit Maxwell-Boltzmann distributions ($\langle$E$\rangle$/q)/T=0.41 ± 0.05.

74 ATOMIC AND MOLECULAR PHYSICS↗

High resolution diagnostic tools for superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 –10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two high-resolution diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system, which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. This setup has a spatial resolution of ~ 13 μm in the azimuthal direction and ~ 1 cm along the cavity contour. The second setup is a stationary, combined magnetic and temperature mapping system, which uses anisotropic magnetoresistance sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. This system has a spatial resolution of 5 mm close to the iris and 11 mm at the equator. Initial results show a non-uniform distribution of trapped flux on the cavities’ surfaces, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hg(+) Frequency Standards

In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

Prestage, John D.↗

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.

Walsworth, Ronald L.↗

Large Solar-Rejection Filter

NASA utilized Image Intensified Video Cameras for ATV data acquisition from a jet flying at 12.8 km. Afterwards the video was digitized and then analyzed with a modified commercial software package, Image Systems Trackeye. Astrometric results were limited by saturation, plate scale, and imposed linear plate solution based on field reference stars. Time-dependent fragment angular trajectories, velocities, accelerations, and luminosities were derived in each video segment. It was evident that individual fragments behave differently. Photometric accuracy was insufficient to confidently assess correlations between luminosity and fragment spatial behavior (velocity, deceleration). Use of high resolution digital video cameras in future should remedy this shortcoming. A scenically accurate description of matter interpreted as a substance made up of corpuscular constituents was established during the course of the 19th century. In this description, atoms--the building blocks of the matter--form molecules. The properties of the molecules were described by chemistry or thermodynamics depending on what characteristics of the matter were investigated. In both theories, the molecules can dissociate to atoms when the kinetic energies of the atoms exceed the strength of the chemical bonds. The number of atoms is always preserved in a closed system. This is not true, however, when the matter takes up much higher energies at relativistic scales. New particles can be produced at the expense of the kinetic energy. The number of particles is no longer preserved. There are other conserved quantities, however, these quantities, the charge, baryon number, lepton number, are associated with particles that are considered elementary today. The properties and behavior of these elementary particles is the subject of Particle Physics or High Energy Physics. Practice Page: A crewmember touching a positively charged surface was thought to be galvanically isolated from the vehicle ground analogous to a bird on a high voltage power wire. Recent analysis confirms that positive floating potentials, ionospheric currents to the EVA suit, can be hazardous. The analysis is wrong in that the ionospheric plasma itself can close the circuit. Parametric analysis of very low voltage exposures (2 to 15 volts) could cause pain and/or involuntary muscle tetani or spinal cord shock. NASA worked with the Naval Health Research Center Detachment Directed Energy Bioeffects Laboratory to examine the affects electrical hazards could have on extravehicular activity using two models. The results of the two computational models were combined to predict areas of the body in which neurons of different diameters would be excited. They predicted that physiologically active current could be conducted across the crew member causing catastrophic hazards. Future work to analyze additional current paths was proposed. The FUSE spectrum of BB Dor, observed in a high state, is modeled with an accretion disk with a very low inclination (possibly lower than 10 degrees). Assuming an average WD mass of 0.8 solar mass leads to a distance of the order of approximately 650pc, consistent with the extremely low galactic reddening in its direction, and a mass accretion rate of 10 (exp -9) solar mass a year. The spectrum presents some broad and deep silicon and sulfur absorption lines, indicating that these elements are over-abundant: silicon is 3 times solar, and sulfur is 20 times solar. The FUSE spectrum of BB Dor, observed in a high state, is modeled with an accretion disk with a very low inclination (possibly lower than 10 degrees). Assuming an average WD mass of 0.8 solar mass leads to a distance of the order of approximately 650pc, consistent with the extremely low galactic reddening in its direction, and a mass accretion rate of 10 (exp -9) solar mass a year. The spectrum presents some broad and deep silicon and sulfur absorption lines, indicating that these elements are over-abundant: silicon is times solar, and sulfur is 20 times solar. From its previously observed optical emission lines, P831-57 (WD 0334 6400 or Ret 1 in A Catalog and Atlas of Cataclysmic Variables: Living Edition) has been suspected to contain an accretion disk associated with a companion star in orbit around a subdwarf star with a temperature T is greater than 21,000K. P831-57 has therefore been classified as a nova-like. However, our present observations show it to be a DA + dMe binary. The analysis of its Far Ultraviolet Spectroscopic Explorer (FUSE) spectrum (continuum and lines) reveal an average mass white dwarf (Log(g) approximately equals 7.8 plus or minus 0.1)with a temperature T approximately equals 37,000 plus or minus 500K, an extremely low projected rotational velocity, and a distance of about 115 plus or minus 5pc. The photosphere contains C, N, Si, and S (at about 1% of solar abundances). The dMe star is seen as a flux excess in near-infrared photometry and appears to show occasional flaring of about one magnitude as seen in the Harvard plates. There is no evidence of periodic variability in the spectroscopic or photometric data. We find no evidence of a an accretion disk, instead we find evidence of wind accretion as the stellar carbon abundance (N(C)/N(H) = 2.5 x 10 (exp -6) is about ten times larger than predicted by radiative levitation for such a gravity and temperature. The power needs and solutions for the space exploration and lunar mobility program are discussed. Long term missions in space and on the lunar surface require high energy batteries. Rechargeable batteries for mobility systems and portable utility pallet are needed for successful exploration missions. Nanomaterial usage increases the energy density of the cells apart from increasing the power density. The symptoms and threats from acute mountain sickness (AMS) are discussed. The underlying assumptions concerning spacecraft atmosphere mean there is a potential risk to astronauts. The baseline worst case scenario is about 25% based on direct ascent to 8.0 psia with 32% O2. The practical mitigation approach is a staged depressurization scheme. Due to the uncertainty about potential AMS risk the flight surgeon should prepare, focused research should proceed, and current analytical efforts should continue. This slide presentation reviews the threat astronauts face from acute mountain sickness (AMS). The incidence of AMS is highly variable and the risk to astronauts is unclear. However, the potential risk is higher than current EAAs suggest and precautions should be implemented. Due to the uncertain nature of the risk flight surgeons should prepare, and focused research should proceed. Quasiparticle tunneling can be understood at low temperatures using a non-equilibrium kinetic theory. Low-temperature tunneling can be suppressed using existing techniques: island-lead gap engineering, lead cooling with SIN junctions, and quasiparticle traps. The slide presentation reviews the science goals and mission planning for the proposed Jupiter System Observer (JSO). The spacecraft would accommodate 9 instruments making the instrument payload more capable than any previously flown to Jupiter. The would-be mission includes study programs for Jupiter's satellites, interior, magnetosphere and atmosphere. The power needs and solutions for the space exploration and lunar mobility program are discussed. Long term missions in space and on the lunar surface require high energy batteries. Rechargeable batteries for mobility systems and portable utility pallet are needed for successful exploration missions. Nanomaterial usage increases the energy density of the cells apart from increasing the power density. This slide presentation reviews the power requirements for the space exploration and the lunar surface mobility programs. It includes information about the specifications for high energy batteries and the power requirements for lunar rovers,

Roberts, William↗

Monte Carlo Dropout Uncertainty Quantification of Long Short-Term Memory Autoencoder Anomaly Detection in a Liquid Sodium Cold Trap

Advanced high-temperature fluid reactors, such as sodium-cooled fast reactors (SFRs) and molten salt–cooled reactors (MSCRs), require coolant purification systems to prevent fluid contamination and local freezing that can lead to plugging. Liquid sodium purification can be achieved with a cold trap, where the sodium temperature is reduced to a near-freezing point to precipitate out impurities. Automation of monitoring of the cold trap performance with machine learning algorithms can aid in early detection of incipient anomalies. An efficient approach to loss-of-coolant–type anomaly detection in a cold trap monitored with more than two dozen thermal-hydraulic sensors consists of a long short-term memory (LSTM) autoencoder. This work develops the uncertainty quantification of the LSTM autoencoder performance for cold trap anomaly detection using the Monte Carlo (MC) dropout method. The MC dropout methodology creates a distribution of sister distributions that all slightly differ from each other because of random neurons being turned off for testing. The variances of the sister network distributions are used to make an uncertainty interval. Our analysis shows that the uncertainty in the autoencoder performance is largest near the peak of the anomaly signal. Using the MC dropout method, we investigate the uncertainty in the anomaly detection with missing sensor inputs. This capability allows the reactor operator to evaluate resilience of the anomaly detection system and to make informed decisions about continuity of operation in the event of sensor failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗