Control Decision and Control Development of Hanford Tank Farms First Two ISA-84 Safety Instrumented Systems - 17370

Hanford's 242-A Evaporator has had the mission of reducing waste volume in the Hanford Tank Farms since the late 1970's. Until 2014, the Documented Safety Analysis for the 242-A facility considered protection and controls of the collocated worker (workers outside the facility) and the public. In 2010, Tank Farms Nuclear Safety engineers initiated a significant revision of the Documented Safety Analysis to implement DOE-STD-3009, Change Notice 3, which requires the protection of the facility worker in addition to the collocated worker and public. Through the use of an extensive process hazards analysis performed on the facility, it was concluded that it was essential to control conditions in the primary evaporation vessel (C-A-1) such that flammable gasses could not build up to the Lower Flammability Limit, and that another control was necessary to ensure that the C-A-1 vessel could not overflow. Early control decision meetings held during the development of the Documented Safety Analysis revision yielded no simple solution to the protection of workers from a flammable gas deflagration. Controls selected for the waste overflow accident were all mitigative in nature (i.e. the detection of a waste overflow after it already happened). Engineering could not replace the mitigative controls with preventive controls without attempting to credit some of the existing facility interlocks associated with the C-A-1 vessel operations. Software and hard-wired interlocks had been used at the facility to prevent overheating of the waste and overfilling of the C-A-1 vessel. These interlocks were considered useful to the prevention of the flammable gas deflagration and vessel overfilling accidents, but lacked the pedigree and reliability necessary to credit the interlocks as safety significant. It was at this stage of the Documented Safety Analysis control decision and control development that engineering became aware of the DOE's acceptance of the ISA-84 instrumented system standard. It became apparent that the ideal solution was not to attempt to credit existing interlock systems, but to develop a new system of 'safety interlocks' to the ISA-84 standard. A meeting was held with upper management of both engineering and operations to propose the use of safety instrumented systems at the 242-A facility. URS Corporation (now AECOM), who had recently supported the Savanah River site in developing ISA-84 controls, was consulted to support the development of two new instrumented systems for the 242-A facility. In addition to the use of the newly adopted ISA-84 standard, the failure modes and effect analysis process was implemented in a very effective manner to support the development of the new safety instrumented systems. Through a brand new methodology, and through a very dedicated and hard-working engineering, projects, and operations team, the new controls were designed, built, tested, and commissioned. At this time, five successful waste reduction campaigns have been performed at the facility with the new safety instrumented systems. During these waste processing campaigns, trips and spurious trips of the SIS have occurred - all of which acted properly. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controllability analysis and decentralized control of a wet limestone flue gas desulfurization plant

Presently, decentralized feedback control is the only control strategy used in wet limestone flue gas desulfurization (WLFGD) plants. Proper tuning of this control strategy is becoming an important issue in WLFGD plants because more stringent SO{sub 2} regulations have come into force recently. Controllability analysis is a highly valuable tool for proper design of control systems, but it has not been applied to WLFGD plants so far. In this paper a decentralized control strategy is designed and applied to a WLFGD pilot plant taking into account the conclusions of a controllability analysis. The results reveal that good SO{sub 2} control in WLFGD plants can be achieved mainly because the main disturbance of the process is well-aligned with the plant and interactions between control loops are beneficial to SO{sub 2} control.

01 COAL, LIGNITE, AND PEAT↗

Decentralized Control of Cascaded H-Bridge Inverters for Medium-Voltage Grid Integration: Preprint

This paper introduces a fully decentralized control strategy that allows for individualized active and reactive power control of H-bridge inverters connected in series. After formulating a model of the system power flows, we outline a communications-free approach where each inverter can act on independent commands. Inverter-level feedback is accomplished locally via a measurement of current flowing through the stack. A key feature is the lack of any centralized control routines or phase-locked loop. In this framework, the reactive power control loops achieve voltage synchronization among the converters and the grid, and the active power control loops modulate the terminal voltage amplitudes that influence power delivery. Furthermore, pole placement via state feedback is used to ensure stability of voltage synchronization while also enabling tracking of bidirectional power commands. Simulations are presented to validate the proposed approach.

communication-free modular converter control↗

COHORT: Coordination of Heterogeneous Thermostatically Controlled Loads for Demand Flexibility

Demand flexibility is increasingly important for power grids. Careful coordination of thermostatically controlled loads (TCLs) can modulate energy demand, decrease operating costs, and increase grid resiliency. We propose a novel distributed control framework for the Coordination Of HeterOgeneous Residential Thermostatically controlled loads (COHORT). COHORT is a practical, scalable, and versatile solution that coordinates a population of TCLs to jointly optimize a grid-level objective, while satisfying each TCL’s end-use requirements and operational constraints. To achieve that, we decompose the grid-scale problem into subproblems and coordi- nate their solutions to find the global optimum using the alternating direction method of multipliers (ADMM). The TCLs’ local problems are distributed to and computed in parallel at each TCL, making COHORT highly scalable and privacy-preserving. While each TCL poses combinatorial and non-convex constraints, we characterize these constraints as a convex set through relaxation, thereby making COHORT computationally viable over long planning horizons. After coordination, each TCL is responsible for its own control and tracks the agreed-upon power trajectory with its preferred strategy. In this work, we translate continuous power back to discrete on/off actuation, using pulse width modulation. COHORT is generalizable to a wide range of grid objectives, which we demonstrate through three distinct use cases: generation following, minimizing ramping, and peak load curtailment. In a notable experiment, we validated our approach through a hardware-in-the-loop simulation, including a real-world air conditioner (AC) controlled via a smart thermostat, and simulated instances of ACs modeled after real-world data traces. During the 15-day experimental period, COHORT reduced daily peak loads by an average of 12.5% and maintained comfortable temperatures.

demand response↗

Control Banding Nanotool: Evaluation of a qualitative risk assessment method for the control of nanoparticulate exposures

Control Banding strategies offer a simplified control of worker exposures when there is an absence of firm toxicological and exposure information. The nanotechnology industry fits this classification as there are overwhelming uncertainties of work-related health risks posed by nanomaterials. Many experts have suggested Control Banding as a solution for these issues. A recent survey shows a majority of nanomaterial users are not performing a basic risk assessment of their product in use. A Control Banding Nanotool has been developed and implemented to afford a qualitative risk assessment toward the control of nanoparticle exposures. The international use of the Control Banding Nanotool reflects on both its need and its possibilities. By developing this dynamic Control Banding Nanotool within the realm of the scientific information available, this application of Control Banding appears to be a useful approach for assessing the risk of nanomaterial operations. This success can be seen in providing recommendations for appropriate engineering controls, facilitating the allocation of resources to the activities that most need them, and initiating an appropriate discussion of these risks with nonexperts. Experts have requested standardization of toxicological parameters, affording better utility and consistency of research. This database of toxicological research findings should be harnessed and presented in a format feeding directly into the Control Banding Nanotool severity and probability risk matrix. Making the latest research available for experts and practitioners alike will provide the best protection of workers in the nanotechnology industries. This presentation will also show the science behind the simplified Control Banding Nanotool approach, its structure, weighting of risks, utility for exposure mitigation, and the research needs to bolster its effectiveness.

99 GENERAL AND MISCELLANEOUS↗

Modelica-based system modeling for studying control-related faults in chiller plants and boiler plants serving large office buildings

System modeling is critical when studying operation faults in chiller plants and boiler plants. However, current fault models have difficulties faithfully representing the operation of chiller plants and boiler plants under the effects of those faults, especially the control-related ones. In this study, we present a systematic method to develop high-fidelity models for approximating the behaviors of chiller plants and boiler plants under faulty conditions. Compared to existing ones, the resulting fault models have two advantages: first, they better characterize the dynamic patterns in the system operation. In those models, control architecture and control logic are faithfully implemented. Thus, they can be used to study control-related faults, such as incorrect staging control due to sensor bias and mistuned feedback control. Second, they are readily extensible and can support large-scale investigations to explore different faulty conditions/scenarios. Those models are established in a hierarchical structure while modules in each layer can be redeclared and parameterized at upper layers. In such a case, modifications to the models can be realized through model modifiers and the process can be easily streamlined with scripts. We applied the proposed models in a comprehensive fault impact evaluation of the 13 control-related faults of chiller and boiler plants. In this evaluation, the proposed plant model is coupled with the EnergyPlus thermal load model to study the impact of various faulty scenarios. Based on the evaluation results, we identified the faults that have the most significant impacts on the operation of the chiller and boiler plants, respectively. We also found that the relationship between the impacts of the studied faults and the severity level of the faults are highly non-linear

Huang, Sen↗

Equivalent Test Bed in PSCAD and PSLF for Studying Advanced Power Systems Controller Performance

With increasing popularity of sustainable energy resources, research on power electronic-based renewable generation modeling is gaining impetus to enhance reliability of electric grids with high penetrations of renewable energy. A set of generic and public models for renewable energy are available in commercial positive sequence power system simulation software. However, advanced controller models applicable for renewable resources are typically not included in these tools. To ensure the integrity of the newly developed controller models for renewables in positive sequence simulators for large power systems, it is necessary to validate the dynamic performance of the proposed model with detailed electromagnetic models. This paper creates an equivalent test bed in PSCAD and PSLF for validating the performance of advanced controllers associated with renewable energy sources. To demonstrate the usefulness of the test-bed, a user-defined synthetic inertia (SI) controller model was developed in PSLF and validated through the proposed test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexibility Estimation and Control of Thermostatically Controlled Loads with Lock Time for Regulation Service

A virtual battery model is a simple and general method to quantify aggregate flexibility from thermostatically controlled loads (TCLs), enabling grid operators to effectively coordinate a large number of flexible building loads with supplyside resources in power systems. Lockout controls are designed to avoid wear and tear resulting from short-cycling of hardware. The lock on/off time could significantly affect aggregate flexibility from TCLs to provide ancillary services and may even fail control algorithms designed without considering the lock time constraints. This paper focuses on flexibility estimation and control design for TCLs with lock time constraints to provide frequency regulation service. We first investigate the potential impacts of lock time on TCLs’ aggregate flexibility and control performance. Both control-dependent and control-independent power bounds are derived, based on either previous TCL switching operations or regulation signals. While the control-dependent method provides aggregate flexibility for a given control method, the control-independent method calculates the theoretical maximum of power bounds. Two control algorithms are proposed to better distribute flexibility over time and thereby improve signal tracking performance. The proposed methods are illustrated and validated through simulations.

Wang, Peng↗

Automated Reconstruction of Control Logic for Programmable Logic Controller Forensics

This paper presents Similo, an automated scalable framework for control logic forensics in industrial control systems. Similo is designed to investigate denial of engineering operations (DEO) attacks, recently demonstrated to hide malicious control logic in a programmable logic controller (PLC) at field sites from an engineering software (at control center). The network traffic (if captured) contains substantial evidence to investigate DEO attacks including manipulation of control logic. Laddis, a state-of-the-art forensic approach for DEO attacks, is a binary-logic decompiler for the Allen-Bradley’s RSLogix engineering software and MicroLogix 1400 PLC. It is developed with extensive manual reverse engineering effort of the underlying proprietary network protocol and the binary control logic. Unfortunately, Laddis is not scalable and requires similar efforts to extend on other engineering software/PLCs. The proposed solution, Similo, is based on the observation that engineering software of different vendors are equipped with decompilers. Similo is a virtual-PLC framework that integrates the decompilers with their respective (previously-captured) ICS network traffic of control logic. It recovers the binary logic into a high-level source code (of the programming languages defined by IEC 61131-3 standard) automatically. Similo can work with both proprietary/open protocols without requiring protocol specifications and the binary formats of control logic. Thus, it is scalable to different ICS vendors. We evaluate Similo on three PLCs of two ICS vendors, i.e. MicroLogix 1400, MicroLogix 1100, and Modicon M221. These PLCs support proprietary protocols and the control logics written in two programming languages: Ladder Logic and Instruction List. The evaluation results show that Similo can accurately reconstruct a control logic from an ICS network traffic and can be used to investigate the DEO attacks effectively.

Ali qasim, Syed↗

Benchmarking Real-Time Control Platforms Using a Matlab/Simulink Coder with Applications in the Control of DC/AC Switched Power Converters

In the control of DC/AC switched power converters (SPC), one of the most important aspects to be considered is the selection of the real-time control platform. The real-time control platform must be able to meet the high performance efficiency and regulation requirements of the DC/AC SPC, as these typically operate at switching frequencies in the order of kHz to MHz. For this reason, the hardware characteristics of the ADC and PWM, and the processing capacity of the real-time control platform are of vital importance when implementing advanced digital controllers that maintain voltage and current levels within regulatory standards. In this context, we aimed to perform a comparative study of the computation times of different real-time control platforms when implementing different control strategies for DC/AC switched power converters. We also analyzed the impact of the real-time control platforms on the THD of the voltages generated by the DC/AC switched power converters. With the help of this paper, researchers and developers will have criteria to select which real-time control platform to use in real-time control for DC/AC SPC applications.

42 ENGINEERING↗

Active Power Control for Wind Farms Using Distributed Model Predictive Control and Nearest Neighbor Communication: Preprint

Wind plant control strategies, including axial induction and wake steering control, aim to improve the performance of wind farms, including increasing energy production and decreasing turbine loads. This paper presents a linear model of wake characteristics for use with a distributed model predictive control method for the purpose of optimizing axial induction and yaw misalignment setpoints. In particular, we use an iterative, distributed control method with nearest neighbor communication to coordinate turbine control actions that account for wake interactions between turbines. Simulations of the model and controller are performed on a 2x3 array of turbines using a modified version of the FLOw Redirection and Induction in Steady-state (FLORIS) model to dynamically track the relevant wake parameters. Preliminary results show the controller's ability to follow an arbitrary wind farm power reference signal for the purpose of providing active power control (APC) ancillary services for power grid stability. This efficient distributed control strategy can enable real-time wind farm optimization and control, even for very large scale farms.

17 WIND ENERGY↗

Composite Robust $H_\infty$ Control for Uncertain Stochastic Nonlinear Systems with State Delay via Disturbance Observer

Here in this note, the robust stochastic stabilization and robust H_infinity control problems are investigated for uncertain stochastic time-delay systems with nonlinearity and multiple disturbances. By estimating the disturbance, which can be described by an exogenous model, a composite hierarchical control scheme is proposed that integrates the output of the disturbance observer with state feedback control law. Sufficient conditions for the existence of the disturbance observer and composite hierarchical controller are established in terms of linear matrix inequalities, which ensure the mean-square asymptotic stability of the resulting closed-loop system and the disturbance attenuation. It has been shown that the disturbance rejection performance can also be achieved. A numerical example is provided to show the potential of the proposed techniques and encouraging results have been obtained.

42 ENGINEERING↗

Bridging semantics, control specifications and assessment: A library for scalable demand flexibility controls

There is growing recognition that Demand Flexibility (DF) can play a major role in enhancing grid reliability, with building control applications emerging as key enablers for DF. However, the traditional approach to deploying new control applications in buildings, including those for DF, remains largely manual and tailored to individual buildings, making it difficult to scale. While research efforts have explored semantics-driven portability, DF controls specification, and assessment approaches, these initiatives are fragmented and limited in scope. This paper proposes a novel methodology, grounded in design science research, to integrate these elements and create a comprehensive DF controls library for both industry and academia. This approach is applied to develop the Demand FLEXibility controls LIBrary using Semantics (DFLEXLIBS), an extensible open-source library that provides DF controls for HVAC systems in Python. DFLEXLIBS enables portable, easy-to-deploy controls that abstract building-specific data points, facilitating assessment across diverse buildings. DFLEXLIBS features nine different control applications, and it is successfully implemented and tested across four virtual and two real buildings, bridging the gap between semantics-driven portability, DF controls specification, and rigorous performance assessment. Its benefits are measured by a reusability ratio greater than 90% and a functional overlap ratio of around 70% for the most common functions used in the library, significantly reducing time for deploying new controls.

Controls library↗

Controlling X-rays With Light

Ultrafast x-ray science is an exciting frontier that promises the visualization of electronic, atomic and molecular dynamics on atomic time and length scales. A largelyunexplored area of ultrafast x-ray science is the use of light to control how x-rays interact with matter. In order to extend control concepts established for long wavelengthprobes to the x-ray regime, the optical control field must drive a coherent electronic response on a timescale comparable to femtosecond core-hole lifetimes. An intense field is required to achieve this rapid response. Here an intense optical control pulse isobserved to efficiently modulate photoelectric absorption for x-rays and to create an ultrafast transparency window. We demonstrate an application of x-ray transparencyrelevant to ultrafast x-ray sources: an all-photonic temporal cross-correlation measurement of a femtosecond x-ray pulse. The ability to control x-ray/matterinteractions with light will create new opportunities at current and next-generation x-ray light sources.

43 PARTICLE ACCELERATORS↗

Design of set-point weighting PI{sup λ} + D{sup μ} controller for vertical magnetic flux controller in Damavand tokamak

In this paper, a simple method is presented for tuning weighted PI{sup λ} + D{sup μ} controller parameters based on the pole placement controller of pseudo-second-order fractional systems. One of the advantages of this controller is capability of reducing the disturbance effects and improving response to input, simultaneously. In the following sections, the performance of this controller is evaluated experimentally to control the vertical magnetic flux in Damavand tokamak. For this work, at first a fractional order model is identified using output-error technique in time domain. For various practical experiments, having desired time responses for magnetic flux in Damavand tokamak, is vital. To approach this, at first the desired closed loop reference models are obtained based on generalized characteristic ratio assignment method in fractional order systems. After that, for the identified model, a set-point weighting PI{sup λ} + D{sup μ} controller is designed and simulated. Finally, this controller is implemented on digital signal processor control system of the plant to fast/slow control of magnetic flux. The practical results show appropriate performance of this controller.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Radioactive Iodine and Krypton Control for Nuclear Fuel Reprocessing Facilities

Nuclear fission results in the production of fission products and activation products, some of which tend to be volatile during used fuel reprocessing. These can evolve in volatile species in the reprocessing facility off-gas streams, depending on the separations and reprocessing technologies that are used. Radionuclides that have been identified as “volatile radionuclides” are noble gases (most notably isotopes of Kr and Xe); 3H; 14C; and 129I. Radionuclides that tend to form volatile species that evolve into reprocessing facility off-gas systems are more challenging to efficiently control compared to radionuclides that tend to stay in solid or liquid phases. Future used fuel reprocessing facilities in the United States can require efficient capture of some volatile radionuclides in their off-gas streams to meet regulatory emission requirements. In aqueous reprocessing, these radionuclides are most commonly expected to evolve into off-gas streams in tritiated water [3H2O (T2O) and 3HHO (THO)], radioactive CO2, noble gases, and gaseous HI, I2, or volatile organic iodides. The fate and speciation of these radionuclides from a non-aqueous fuel reprocessing facility is less well known at this time, but active investigations are in progress. An Off-Gas Sigma Team was formed in late FY 2009 to integrate and coordinate the Fuel Cycle Research and Development (FCR&D) activities directed towards the capture and sequestration of the these volatile radionuclides (Jubin 2012a). The Sigma Team concept was envisioned to bring together multidisciplinary teams from across the DOE complex that would work collaboratively to solve the technical challenges and to develop the scientific basis for the capture and immobilization technologies such that the sum of the efforts was greater than the individual parts. The Laboratories currently participating in this effort are Argonne National Laboratory (ANL), Idaho National Laboratory (INL), Oak Ridge National Laboratory (ORNL), Pacific Northwest National Laboratory (PNNL), and Sandia National Laboratories (SNL). This article focuses on control of volatile radionuclides that evolve during aqueous reprocessing of UNF. In particular, most of the work by the Off-gas Sigma Team has focused on the capture and sequestration of 129I and 85Kr, mainly because, as discussed below, control of 129I can require high efficiencies to meet regulatory requirements, and control of 85Kr using cryogenic processing, which has been the technology demonstrated and used commercially to date, can add considerable cost to a reprocessing facility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗