Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Equation-of-state measured via x-ray phase contrast imaging for Epon 828/DEA epoxy

Epoxies are a broad class of polymer materials often used as adhesive, structural or binding materials. Epon 828 is an epoxy resin that can be polymerized with a variety of curing agents with the choice of curing agent potentially having an effect on the resulting epoxy polymer’s material properties. In this study, the dynamic behavior of Epon 828 epoxy resin cured with diethanolamine (DEA) is investigated through a series of tamped Richtmyer-Meshkov instability (RMI) experiments measured with x-ray phase-contrast imaging. The measured shock and particle velocities are combined with data in the literature to calibrate Mie-Grüneisen equations-of-state (EOS) for portions and combinations of the collective dataset. The calibrated Mie-Grüneisen EOS are validated against particle velocity profiles extracted from published literature using the Eulerian hydrocode CTH. Here, the Mie-Grüneisen EOS fit to only the tamped RMI experimental data presented here most closely follows the particle velocity profile in the published literature.

36 MATERIALS SCIENCE↗

High-speed x-ray phase contrast imaging and digital image correlation analysis of microscale shock response of an additively manufactured energetic material simulant

The performance of energetic materials subjected to dynamic loading significantly depends on their micro- and meso-scale structural morphology. The geometric versatility offered by additive manufacturing opens new pathways to tailor the performance of these materials. Additively manufactured energetic materials (AMEMs) have a wide range of structural characteristics with a hierarchy of length scales and process-inherent heterogeneities, which are hitherto difficult to precisely control. It is important to understand how these features affect AMEMs’ response under dynamic/shock loading. Therefore, temporally and spatially resolved measurements of both macroscopic behavior and micro- and meso-level processes influencing macroscopic behavior are required. In this paper, we analyze the shock compression response of an AMEM simulant loaded under several impact conditions and orientations. Furthermore, x-ray phase contrast imaging (PCI) is used to track features across the observed shock front and determine the linear shock velocity vs particle velocity equation of state, as well as to quantify the interior deformation fields via digital image correlation (DIC) analyses. Photon Doppler velocimetry is simultaneously used to measure the particle velocities of the specimens, which are consistent with those obtained from x-ray PCI. The DIC analyses provide an assessment of the average strain fields inside the material, showing that the average axial strain depends on the loading intensity and reaches as high as 0.23 for impact velocities up to 1.5 km/s. The overall results demonstrate the utility of x-ray PCI for probing “in-material” equation of state and interior strains associated with dynamic shock compression behavior of the AMEM simulant.

3D printing↗

A Pockels cell enabled heterodyne phase contrast imaging diagnostic for detection of ion cyclotron emission

This work describes a novel optical heterodyne detection scheme that significantly extends the frequency response of the phase contrast imaging method to detect electron density fluctuations in tens of megahertz frequency range. The system employs a variable frequency electro-optic modulator to allow operation at any frequency in the range 10–40 MHz without the need to realign the system. The frequency coverage of the system makes it suitable to measure the radial structure of the electron density component of ion cyclotron emission on devices having confining magnetic field of a few tesla, thus extending the purely temporal measurements provided so far by magnetic probes.

47 OTHER INSTRUMENTATION↗

X-ray phase-contrast imaging of strong shocks on OMEGA EP

The ongoing improvement in laser technology and target fabrication is opening new possibilities for diagnostic development. An example is x-ray phase-contrast imaging (XPCI), which serves as an advanced x-ray imaging diagnostic in laser-driven experiments. In this work, we present the results of the XPCI platform that was developed at the OMEGA EP Laser-Facility to study multi-Mbar single and double shocks produced using a kilojoule laser driver. Two-dimensional radiation-hydrodynamic simulations agree well with the shock progression and the spherical curvature of the shock fronts. It is demonstrated that XPCI is an excellent method to determine with high accuracy the front position of a trailing shock wave propagating through an expanding CH plasma that was heated by a precursor Mbar shock wave. Furthermore, the interaction between the rarefaction wave and the shock wave results in a clear signature in the radiograph that is well reproduced by radiation-hydrodynamic simulations.

47 OTHER INSTRUMENTATION↗

Planar shock-induced bubble collapse and jetting in water captured via X-ray phase contrast imaging

Shock wave–bubble interactions in water manifest rich dynamics driven by a combination of strong pressure and density mismatches. They have a wide variety of applications, including the injection of pharmaceuticals, and through scaling, enable the exploration of various aspects of high-energy-density systems such as inertial confinement fusion. In this work, the interaction between a micrometric nitrogen bubble and a planar shock wave, characterized by a Mach number of M = 1.24 and a peak pressure of p max = 0.57 , is experimentally recorded using ultra-high-speed x-ray phase contrast imaging. Highly resolved radiographs provide access to all phase discontinuities along the beam path, offering quantities such as the time-varying bubble size, the speed of a jet produced during the bubble collapse, and the time evolution of the shock wave front, which are critical benchmark data for numerical scheme validation. This study addresses the lack of well-characterized, repeatable, and high spatiotemporal resolution experiments at negative Atwood numbers by providing shock–bubble visualization and corresponding numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

Electron tomography imaging methods with diffraction contrast for materials research

Transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) enable the visualization of three-dimensional (3D) microstructures ranging from atomic to micrometer scales using 3D reconstruction techniques based on computed tomography algorithms. This 3D microscopy method is called electron tomography (ET) and has been utilized in the fields of materials science and engineering for more than two decades. Although atomic resolution is one of the current topics in ET research, the development and deployment of intermediate-resolution (non-atomic-resolution) ET imaging methods have garnered considerable attention from researchers. This research trend is probably not irrelevant due to the fact that the spatial resolution and functionality of 3D imaging methods of scanning electron microscopy (SEM) and X-ray microscopy have come to overlap with those of ET. In other words, there may be multiple ways to carry out 3D visualization using different microscopy methods for nanometer-scale objects in materials. From the above standpoint, this review paper aims to (i) describe the current status and issues of intermediate-resolution ET with regard to enhancing the effectiveness of TEM/STEM imaging and (ii) discuss promising applications of state-of-the-art intermediate-resolution ET for materials research with a particular focus on diffraction contrast ET for crystalline microstructures (superlattice domains and dislocations) including a demonstration of in situ dislocation tomography.

36 MATERIALS SCIENCE↗

Deep-learning methods for contrast enhancement and artifact reduction in cryo-electron tomography: a systematic analysis of the state of the art and proposed improvements

Cryo-electron tomography (cryo-ET) has emerged as the preferred technique for visualizing the organization of macromolecular complexes in situ and resolving their structures at subnanometre resolution [Tegunov et al. (2021)View full citation, Nat. Methods, 18, 186–193]. Despite improvements in data quality as a result of advances in detector technology, microscope stability and stage precision, the analysis and interpretation of tomograms remains challenging due to a low signal-to-noise ratio and reconstruction artifacts stemming from experimental constraints in specimen tilt during data collection resulting in a missing wedge in the Fourier space. Recently, self-supervised deep-learning methods have been proposed for contrast enhancement and reduction of resolution anisotropy in reconstructed tomograms. Here, we evaluate several state-of-the-art deep-learning methods which aim to improve the interpretability of cryo-ET reconstructions, with a focus on their performance on downstream tasks of template matching, sub­tomogram averaging and segmentation. We propose new training architectures and a loss function based on Fourier shell correlation that show improved performance over the standard U-Net with L1/L2 losses. We demonstrate our analysis on four diverse experimental datasets: purified 80S ribosomes, in situ Chlamydomonas reinhardtii, immature HIV-1 virus-like particles and INS-1E cells.

contrast enhancement↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

X-Ray Phase Contrast Imaging for Dynamic Material Mix Experiments, LAO-003-17, Year 3 of 3

X-ray phase contrast imaging with transmission gratings for density profile measurements has been developed and tested for dynamic experimental applications. Talbot-Lau x-ray deflectometry is a new method of measuring x-ray refraction in addition to attenuation and ultrasmall-angle scattering that has recently been developed for static imaging, primarily for medical and industrial applications. To obtain density profiles from fast-evolving systems, we must use a flash x-ray source with a spot size much larger than the continuous microfocus sources of static imaging systems, and we can obtain only a single exposure. The challenges to measuring electron density profiles of two mixed elements from a single-image, low spatial resolution system are addressed, and initial results from the first dynamic experiments with one such system, conducted on a gas launcher at the end of FY 2018 and beginning of FY 2019, are presented. In FY 2019, we designed and built a new deflectometer designed for detonator experiments to test new techniques to improve the sensitivity and reliability of the diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Contrast Calibration Protocol for X-ray Speckle Visibility Spectroscopy

X-ray free electron lasers, with their ultrashort highly coherent pulses, opened up the opportunity of probing ultrafast nano- and atomic-scale dynamics in amorphous and disordered material systems via speckle visibility spectroscopy. However, the anticipated count rate in a typical experiment is usually low. Therefore, visibility needs to be extracted via photon statistics analysis, i.e., by estimating the probabilities of multiple photons per pixel events using pixelated detectors. Considering the realistic X-ray detector responses including charge cloud sharing between pixels, pixel readout noise, and gain non-uniformity, speckle visibility extraction relying on photon assignment algorithms are often computationally demanding and suffer from systematic errors. In this paper, we present a systematic study of the commonly-used algorithms by applying them to an experimental data set containing small-angle coherent scattering with visibility levels ranging from below 1% to ∼60%. We also propose a contrast calibration protocol and show that a computationally lightweight algorithm can be implemented for high-speed correlation evaluation.

47 OTHER INSTRUMENTATION↗

Enhanced Optical Contrast and Switching in Near‐Infrared Electrochromic Devices by Optimizing Conjugated Polymer Oligo(Ethylene Glycol) Sidechain Content and Gel Electrolyte Composition

Abstract A detailed investigation addressing the effects of functionalizing conjugated polymers with oligo(ethylene glycol) (EG n ) sidechains on the performance and polymer‐electrolyte compatibility of electrochromic devices (ECDs) is reported. The electrochemistry for a series of donor‐acceptor copolymers having near‐infrared (NIR)‐optical absorption, where the donor fragment is 3,4‐ethylenedioxythiophene (EDOT) or an EG n functionalized bithiophene (g2T) and the acceptor fragment is diketopyrrolopyrrole (DPP) functionalized with branched alkyl or EG n sidechains, is extensively probed. ECDs are next fabricated and it is found that EG n sidechain incorporation must be finely balanced to promote polymer‐electrolyte compatibility and provide efficient ion exchange. Proper electrolyte‐cation pairing and polymer structural tuning affords a 2x increase in optical contrast (from 12% to 24%) and >60x reduction in switching time (from 20 to 0.3 s). Atomic force microscopy (AFM)/grazing incidence wide‐angle X‐ray scattering (GIWAXS) characterization of the polymer film morphology/microstructure reveals that an over‐abundance of EG n sidechains generates large polymer crystallites, which can suppress ion exchange. Lastly, time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) indicates sidechain/electrolyte identity does not influence the electrolyte penetration depth into the films, and EG n sidechain inclusion increases electrolyte cation uptake. The material structural design insight and guidelines regarding the polymer‐electrolyte ion insertion/expulsion dynamics reported here should be of significant utility for developing next‐generation mixed ionic‐electronic conducting materials.

Chemistry↗

Conservative solute transport processes and associated transient storage mechanisms: Comparing streams with contrasting channel morphologies, land use and land cover

Abstract Land use within a watershed impacts stream channel morphology and hydrology and, therefore, in‐stream solute transport processes and associated transient storage mechanisms. This study evaluated transport processes in two contrasting stream sites where channel morphology was influenced by the surrounding land use, land cover, climate and geologic controls: Como Creek, CO, a relatively undisturbed, high gradient, forested stream with a gravel bed and complex channel morphology, and Clear Creek, IA, an incised, low‐gradient stream with low‐permeability substrate draining an agricultural landscape. We performed conservative stream tracer injections at these sites to address the following questions: (1) How does solute transport vary between streams with differing morphologies? and (2) How does solute transport at each stream site change as a function of discharge? We analysed in‐stream tracer time series data and compared results quantifying solute attenuation in surface and subsurface transient storage zones. Significant trends were observed in these metrics with varying discharge conditions at the forested site but not at the agricultural site. There was a broad range of transport mechanisms and evidence of substantial exchange with both surface and hyporheic transient storage in the relatively undisturbed, forested stream. Changing discharge conditions activated or deactivated different solute transport mechanisms in the forested site and greatly impacted advective travel time. Conversely in the simplified agricultural stream, there was a narrow range of solute transport behaviour across flows and predominantly surface transient storage at all measured discharge conditions. These results demonstrate how channel simplification inhibits available solute transport mechanisms across varying discharge conditions.

54 ENVIRONMENTAL SCIENCES↗

Coupled primary production and respiration in a large river contrasts with smaller rivers and streams

Abstract Although time series in ecosystem metabolism are well characterized in small and medium rivers, patterns in the world's largest rivers are almost unknown. Large rivers present technical difficulties, including depth measurements, gas exchange (, ) estimates, and the presence of large dams, which can supersaturate gases. We estimated reach‐scale metabolism for the Hanford Reach of the Columbia River (Washington state, USA), a free‐flowing stretch with an average discharge of 3173 . We calculated from semi‐empirical models and directly estimated it from tracer measurements. We fixed at the median value from these calculations (0.5 ), and used maximum likelihood to estimate reach‐scale, open‐channel metabolism. Both gross primary production (GPP) and ecosystem respiration (ER) were high (GPP range: 0.3–30.8 g , ER range: 0.8–30.6 g ), with peak GPP and ER occurring in the late summer or early fall. GPP increased exponentially with temperature, consistent with metabolic theory, while light was seasonally saturating. Annual average GPP, estimated at 1500 g carbon , was in the top 2% of estimates for other rivers. GPP and ER were tightly coupled and 90% of GPP was immediately respired, resulting in net ecosystem production near 0. Patterns in the Hanford Reach contrast with those in small‐medium rivers, suggesting that metabolism magnitudes and patterns in large rivers may not be simply scaled from knowledge of smaller rivers.

54 ENVIRONMENTAL SCIENCES↗

Trace metal contents of autotrophic flagellates from contrasting open‐ocean ecosystems

Abstract Nano‐ and picophytoplankton are a major component of open‐ocean ecosystems and one of the main plankton functional types in biogeochemical models, yet little is known about their trace metal contents. In cultures of the picoeukaryote Ostreococcus lucimarinus , iron limitation reduced iron quotas by 68%, a fraction of the plasticity known in diatoms. In contrast, a commonly co‐occurring cyanobacterium, Prochlorococcus , showed variable iron contents with iron availability in culture. Synchrotron X‐ray fluorescence was used to measure single‐cell metal (Mn, Fe, Co, Ni, Zn) quotas of autotrophic flagellates (1.4–16.8‐ μ m diameter) collected from four ocean regions. Iron quotas were tightly constrained and showed little response to iron availability, similar to cultured Ostreococcus . Zinc quotas also did not vary with zinc availability but appeared to vary with phosphorus availability. These results suggest that macronutrient and metal availability may be equally important for controlling metal contents of small eukaryotic open‐ocean phytoplankton.

54 ENVIRONMENTAL SCIENCES↗

X-ray Phase Contrast Imaging of the Impact of Multiple HMX Particles in a Polymeric Matrix

The initiation of high explosives (HEs) under shock loading lacks a comprehensive understanding: particularly at the particle scale. One common explanation is the hot spot theory, which suggests that energy in the material resulting from the impact event is localized in a small area causing an increase in temperature that can lead to ignition. This study focuses on the response of HMX particles (a common HE) within a polymer matrix (Sylgard-184 (R)), a simplified example of a polymer-bound explosive (PBX). These PBXs consist of multiple HMX particles in a single polymer-bound sample. A light gas gun was used to load the samples at impact velocities above 400 m/s. The impact events were visualized using X-ray phase-contrast imaging (PCI) allowing real-time observation of the impact event. The experiment used two different types of samples (multi-particle and two crystals) and found evidence of cracking and debonding in both sample types. Additionally, it was found that the multiple particle samples showed similar evidence of damage at lower velocities than that of single particle samples. This is an expected result as the multiple particles add additional interfaces for stress concentration and frictional heating.

42 ENGINEERING↗

Phase Contrast X‐Ray Imaging of the Collapse of an Engineered Void in Single‐Crystal HMX

Abstract Imaging the collapse of a single void that creates a hot spot initiation site in an otherwise defect‐free explosive is challenging given the spatial and temporal scales involved in explosive systems. This work presents our attempt to examine a single hot spot mode (void collapse) in single‐crystal octahydro‐l,3,5,7‐tetranitro‐l,3,5,7‐tetrazocine (HMX) embedded in Sylgard. The hot spot heating mechanisms involved with pore collapse include adiabatic heating, jetting, and viscoplastic dissipation. Quantifying the dynamics of a pore collapse is a crucial step to understanding which mechanisms dominate during ignition events. Our experiments were conducted with a single‐stage, light‐gas gun at Argonne National Laboratory's Advanced Photon Source, applying the phase contrast imaging technique while collecting high‐speed video. The details of HMX single crystal production, defect (pore) engineering, and sample construction, along with experimental results are presented here. These results demonstrate that detailed collapse dynamics can be obtained from homogeneous, single‐crystal explosives with this approach. Qualitative comparisons are made with simulation data which show good agreement in the transition between a quasi‐symmetric pore collapse and an asymmetric collapse with jetting across the pore as measured with normalized pore area and pore circularity.

42 ENGINEERING↗

Seasonal delay of Sahelian rainfall driven by an east–west contrast in radiative forcing in idealized CESM experiments

Recent studies suggest the observed seasonal delay of rainfall over the Sahel is mainly driven by anthropogenic aerosol forcing, which features a robust east–west contrasting changes in recent decades, with negative and positive top-of-the-atmosphere shortwave radiative forcing in South and East Asia (SA&EA) and in North America and Europe (NA&EU), respectively. Their individual effects on the Sahel rainfall annual cycle remain unclear. Here, by designing idealized sensitivity experiments based on Community Earth System Model (CESM1.2), we show that both negative radiative forcing over SA&EA and positive radiative forcing over NA&EU contribute to the delayed phase and enhanced amplitude of Sahel rainfall annual cycle. To understand the underlying physical processes, both the convective quasi-equilibrium (CQE) and atmospheric energetic frameworks are utilized. Both frameworks can well explain the seasonal delay in the rainfall annual cycle over the Sahel under the regional radiative forcings, with the CQE framework showing stronger explanatory power. Based on the insights from both frameworks, we conducted a moisture budget analysis and found that the negative radiative forcing over SA&EA causes an anomalous low-level anticyclonic circulation, which transports more moisture to the Sahel. As the anomalous anticyclone is stronger in summer and fall compared to spring, rainfall is delayed in the Sahel. Further, under the influence of the positive radiative forcing over NA&EU, more warming in the northern hemisphere causes northward transport of moisture to the northern tropics associated with the cross-equatorial transport of energy. The moisture transport increases relativehumidity over the Sahel and enhances the effective atmospheric heat capacity that delays the seasonal rainfall.

54 ENVIRONMENTAL SCIENCES↗