Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condensate pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A helium-3 refrigerator employing capillary confinement of liquid cryogen

A condensation refrigerator suitable for operation in a zero gravity space environment was constructed. The condensed liquid refrigerant is confined by surface tension inside a porous metal matrix. Helium-4 and helium-3 gases were condensed and held in a copper matrix. Evaporative cooling of confined liquid helium-4 resulted in a temperature of 1.4K. Using a zeolite adsorption pump external to the cryostat, a temperature of 0.6 K was achieved through evaporative cooling of liquid helium-3. The amount of time required for complete evaporation of a controlled mass of liquid helium-4 contained in the copper matrix was measured as a function of the applied background power. For heating powers below 18 mW the measured times are consistent with the normal boiling of the confined volume of liquid refrigerant. At background powers above 18 mW the rapid rise in the temperature of the copper matrix the signature of the absence of confined liquid occurs in a time a factor of two shorter than that expected on the basis of an extrapolation of the low power data.

Ennis, D. J.↗

Investigation of Condensation/Clustering Effects on Rayleigh Scattering Measurements in a Hypersonic Wind Tunnel

Rayleigh scattering, a nonintrusive measurement technique for the measurement of density in a hypersonic wind tunnel, is under investigation at Wright Laboratory's Mach 6 wind tunnel. Several adverse effects, i.e., extraneous scatter off walls and windows, hinder Rayleigh scattering measurements. Condensation and clustering of flow constituents also present formidable obstacles. Overcoming some of these difficulties, measurements have been achieved while the Mach 6 test section was pumped down to a vacuum, as well as for actual tunnel operation for various stagnation pressures at fixed stagnation temperatures. Stagnation pressures ranged from 0.69 MPa to 6.9 MPa at fixed stagnation temperatures of 511, 556, and 611 K. Rayleigh scatter results show signal levels much higher than expected for molecular scattering in the wind tunnel. Even with higher than expected signals, scattering measurements have been made in the flowfield of an 8-degree half-angle blunt nose cone with a nose radius of 1.5 cm.

Tyler, Charles↗

Analysis and Modeling of a Two-Phase Jet Pump of a Flow Boiling Test Facility for Aerospace Applications

Jet pumps are devices capable of pumping fluids to a higher pressure employing a nozzle/diffuser/mixing chamber combination. A primary fluid is usually allowed to pass through a converging-diverging nozzle where it can accelerate to supersonic speeds at the nozzle exit. The relatively high kinetic energy that the primary fluid possesses at the nozzle exit is accompanied by a low pressure region in order to satisfy Bernoulli's equation. The low pressure region downstream of the nozzle exit permits a secondary fluid to be entrained into and mixed with the primary fluid in a mixing chamber located downstream of the nozzle. Several combinations may exist in terms of the nature of the primary and secondary fluids in so far as whether they are single or two-phase fluids. Depending on this, the jet pump may be classified as gas/gas, gas/liquid, liquid/liquid, two-phase/liquid, or similar combinations. The mixing chamber serves to create a homogeneous single-phase or two-phase mixture which enters a diffuser where the high kinetic energy of the fluid is converted into pressure energy. If the fluid mixture entering the diffuser is in the supersonic flow regime, a normal shock wave usually develops inside the diffuser. If the fluid mixture is one that can easily change phase, a condensation shock would normally develop. Because of the overall rise in pressure in the diffuser as well as the additional rise in pressure across the shock layer, condensation becomes more likely. Associated with the pressure rise across the shock is a velocity reduction from the supersonic to the subsonic range. If the two-phase flow entering the diffuser is predominantly gaseous with liquid droplets suspended in it, it will transform into a predominantly liquid flow containing gaseous bubbles (bubbly flow) somewhere in the diffuser. While past researchers have been able to model the two-phase flow jet pump using the one-dimensional assumption with no shock waves and no phase change, there is no research known to the authors apart from that of Anand (1992) which accounted for condensation shocks. One of the objectives of this research effort is to develop a comprehensive model in which the effects of phase slip and inter-phase heat transfer as well as the wall friction and shock waves are accounted for. While this modeling effort is predominantly analytical in nature and is primarily intended to provide a parametric understanding of the jet pump performance under different operating scenarios, another parallel effort employing a commercial CFD code is also implemented. The latter effort is primarily intended to model an axisymmetric counterpart of the problem in question. The viability of using the CFD code to model a two-phase flow jet pump will be assessed by attempting to recreate some of the existing performance data of similar jet pumps. The code will eventually be used to generate the jet pump performance characteristics of several scenarios involving jet pump geometries as well as flow regimes in order to be able to determine an optimum design which would be suitable for a two-phase flow boiling test facility at NASA-Marshall. Because of the extensive nature of the analytical model developed, the following section will only provide very brief highlights of it, while leaving the details to a more complete report submitted to the NASA colleague. This report will also contain some of the simulation results obtained using the CFD code.

Sherif, S. A.↗

The Trajectory of Recent Solid State Fusion Results

Both NASA and Google have explored and funded Low Energy Nuclear Reaction (LENR) aka Solid-State Fusion or Lattice Confinement Fusion (LCF) research. NASA has funded efforts since 1989, and Google Research began in 2014. Google, and researchers initially-funded by Google, published significant scientific papers in Nature, Nature Communications and the Journal of Applied Physics. NASA began a significant set of LENR-triggering programs in 2012 resulting in papers in Physical Review C, the Journal of Electroanalytical Chemistry and the Journal of Condensed Matter Nuclear Science. Both NASA and Google engaged researchers across fields of nuclear physics, chemistry, electrochemistry, material science and more. NASA built upon early novel gas pumping experiments then followed the patented work of the US Navy SPAWAR (US8,419,919, “System and Method to Generate Particles”) and experiments with the Naval Surface Warfare Centers. Google supported researchers at Lawrence Berkeley National Laboratory (LBNL), the University of British Columbia (UBC), MIT and others. This resulted in patent applications and two granted patents (US10264661B2, “Target structure for enhanced electron screening” and US10566094B2 “Enhanced electron screening through plasmon oscillations”). These separate efforts, unknown to the researchers at the time, provided the impetus for the DoE ARPA-E LENR program followed by the DARPA DSO “Mechanisms for Amplification of Fusion Reaction Rates in Solids” (MARRS) program. This document briefly describes the overlapping NASA and Google Research efforts in plasma loading and electron screening emphasizing the results of the latest paper in Nature Communications. The papers and patents cited are listed.

electron screening↗

Thermodynamic Vent System Test in a Low Earth Orbit Simulation

A thermodynamic vent system for a cryogenic nitrogen tank was tested in a vacuum chamber simulating oxygen storage in low earth orbit. The nitrogen tank was surrounded by a cryo-shroud at -40 F. The tank was insulated with two layers of multi-layer insulation. Heat transfer into cryogenic tanks causes phase change and increases tank pressure which must be controlled. A thermodynamic vent system was used to control pressure as the location of vapor is unknown in low gravity and direct venting would be wasteful. The thermodynamic vent system consists of a Joule-Thomson valve and heat exchanger installed on the inlet side of the tank mixer-pump. The combination is used to extract thermal energy from the tank fluid, reducing temperature and ullage pressure. The system was sized so that the tank mixer-pump operated a small fraction of the time to limit motor heating. Initially the mixer used sub-cooled liquid to cool the liquid-vapor interface inducing condensation and pressure reduction. Later, the thermodynamic vent system was used. Pressure cycles were performed until steady-state operation was demonstrated. Three test runs were conducted at tank fills of 97, 80, and 63 percent. Each test was begun with a boil-off test to determine heat transfer into the tank. The lower tank fills had time averaged vent rates very close to steady-state boil-off rates showing the thermodynamic vent system was nearly as efficient as direct venting in normal gravity.

VanOverbeke, Thomas J.↗

Fluid Transient Analysis During Priming of Evacuated Line

Pressure surges are critical in the design of spacecraft propellant feed lines. The pressure transients that occur during priming of feed lines are very important in the design and analysis of liquid propulsion systems. During the start-up of the propulsion system of a spacecraft, the process of filling of an evacuated pipeline is called priming. Priming can generate severe pressure peaks due to the slam (water hammer) of the propellant against a closed thruster valve. The downstream conditions strongly affect the pressure surge. In space systems, satellites, or interplanetary probes, the propellant lines are vacuum-pumped or filled with low pressure helium or nitrogen before the launch. Before operations, these lines are primed with a vaporizing liquid, sometimes in the presence of a non-condensable gas (NCG), which produces water hammer phenomena. The objective of the current study is to use a finite volume based network flow solver (Generalized Fluid System Simulation Program, GFSSP) for the numerical simulation of Priming in (a) a straight feedline and (b) a flow network. The geometrical configurations and dimensions for the pipe and other components used for the current study are identical to experimental study of Prickett et al.

Bandyopadhyay, Alak↗

Development of an Additive Manufactured Cryogenic TVS Augmented Injector

Cryogenic fluid transfer is critical in ground and space systems. Transfer typically requires venting a receiver vessel during the chill and fill process to maintain a pressure favorable to fluid flow. Venting in space is problematic due to low-gravity where fluid position is indeterminate; possibly allowing fluid to flow out the vent. To control receiver tank venting the vented chill/no-vent fill methodology is attractive. An additively manufactured Injector coupled with a Thermodynamic Venting System (TVS) augmentation can enable the vented chill/no-vent fill approach with simplified operations. The TVS augmented injector includes an internal heat exchanger, fluid injector spray head, and external surface condensation heat exchange; combined with integrated flow paths in one part. Operations using the injector allow the tank vent to be closed very early in the transfer and not reopened. The TVS circuit eliminates the potential for stalled fill by maintaining cooling flow on the injector and condenser elements, reducing tank pressure. The injector can also be employed for long-term cryo fluid storage as a means of controlling tank pressure if integrated with a recirculation pump. A cryo-cooler can be used in place of/or augmenting the TVS flow circuit for a zero loss pressure control system. The Injector was developed using the principles of design for additive manufacture and printed as one part, resulting in part count reduction, improved reproducibility, shorter lead times, and reduced cost. The TVS augmented injector is compact and highly adaptable simplifying its integration. A key benefit is that this methodology enables simplified operations in reaching 100% fill conditions.

Omar Mireles↗

Interstellar molecules

Progress in the discovery and study of interstellar molecules is summarized. The 36 molecular species thus far identified in interstellar space are listed in several groups which include simple hydrides, oxides, and sulfides, various derivatives of ammonia, molecules involving linear carbon chains, cyanides, and molecules related in structure to formaldehyde, alcohols, or ethers. Several free radicals are described, the discovery of molecules in external galaxies is discussed, and possible mechanisms for molecular formation are noted. Methods for examining relative isotopic abundances by measuring molecules in interstellar clouds are outlined, mechanisms for the excitation of interstellar molecules are reviewed, and values are presented for the C-12/C-13 abundance ratio in a number of interstellar clouds. The detection of interstellar masers is discussed along with pumping mechanisms and masing transitions in H2CO, CH, OH, and SiO. The nature of dense interstellar clouds is examined in terms of several simple and complex cloud models, with emphasis on multiple condensation models.

Townes, C. H.↗

Huygens/ACP: An instrument for aerosols chemical composition measurements

The Aerosol Collector Pyrolyzer (ACP) which will be used aboard the Huygens probe is introduced. The scientific objectives, scientific rationale, and a technical description of the ACP are given. The ACP will sample the aerosols of the Titan's atmosphere in two regions, 160 to 60 and 60 to 25 km, respectively. In the first region, it will collect aerosol particles absorbed by a complex core (organic polymers) coated with absorbed or condensed molecules. The second collect will sample larger aerosols and the N2-CH4 droplets. In each sampling, the particles are collected on a metallic filter through which the atmospheric gas is pumped. The filter is then inserted into an oven connected to the Gas Chromatograph Mass Spectrometer (GCMS) Experiment which analyzes the gases produced during the heating of the samples. For each sample it will be possible to bring information on the nature and abundance of the volatile components contained in the particles and/or the composition of the photochemical core.

Israel, Guy↗

Two-phase/two-phase heat exchanger simulation analysis

The capillary pumped loop (CPL) system is one of the most desirable devices to dissipate heat energy in the radiation environment of the Space Station providing a relatively easy control of the temperature. A condenser, a component of the CPL system, is linked with a buffer evaporator in the form of an annulus section of a double tube heat exchanger arrangement: the concentric core of the double tube is the condenser; the annulus section is used as a buffer between the conditioned space and the radiation surrounding but works as an evaporator. A CPL system with this type of condenser is modeled to simulate its function numerically. Preliminary results for temperature variations of the system are shown and more investigations are suggested for further improvement.

Kim, Rhyn H.↗

Review of Orbital Propellant Transfer Techniques and the Feasibility of a Thermal Bootstrap Propellant Transfer Concepts

This study was performed in support of the NASA Task B-2 Study Plan for Space Basing. The nature of space-based operations implies that orbital transfer of propellant is a prime consideration. The intent of this report is (1) to report on the findings and recommendations of existing literature on space-based propellant transfer techniques, and (2) to determine possible alternatives to the recommended methods. The reviewed literature recommends, in general, the use of conventional liquid transfer techniques (i.e., pumping) in conjunction with an artificially induced gravitational field. An alternate concept that was studied, the Thermal Bootstrap Transfer Process, is based on the compression of a two-phase fluid with subsequent condensation to a liquid (vapor compression/condensation). This concept utilizes the intrinsic energy capacities of the tanks and propellant by exploiting temperature differentials and available energy differences. The results indicate the thermodynamic feasibility of the Thermal Bootstrap Transfer Process for a specific range of tank sizes, temperatures, fill-factors and receiver tank heat transfer coefficients.

Yoshikawa, H. H.↗

Nonazeotropic Heat Pump

Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

Ealker, David H.↗

In situ measurement of the cosmic microwave background temperature at a distance of 7.5 kiloparsecs

Absorption of orthoformaldehyde (H2CO) toward the giant H II region W51A (G49.5 - 0.4) has been used as a remote probe of the cosmic microwave background (CMB) at a distance of 7.5 kpc. VLA observations of the 6 cm and 2 cm wavelength transitions provided sufficient resolution and sensitivity to resolve condensations within the foregound clouds. Solutions to the equations of statistical equilibrium within each condensation in the context of a large velocity gradient model yielded an estimate for the CMB temperature at 2.1 mm wavelength of 3.2 + or - 0.9 K. The uncertainty is dominated by modeling of collisional pumping by neutral hydrogen molecules (H2).

Kogut, A.↗

Two-Phase Bidirectional Heat Exchanger

Heat exchanger transfers heat from one two-phase thermal loop to another. Condenses vapor in one loop while evaporating liquid in other. Transfers heat with very small drops in temperature and pressure, and efficiently joins heat pipes thermally without mixing of their working fluids. Several such heat exchangers used to build long, complex multiloop heat-control systems. Exchanger bidirectional: transfers heat in reverse, condensing on normally evaporating side, and vice versa. Can warm equipment it normally cools, without using auxiliary heater. In reverse transfer, wicks on evaporating side supply liquid continuously by capillary action; reverse-flow pump not needed. Design modified for other working fluids and larger heat-transfer rates.

Kroliczek, Edward↗

Development of the Next Generation Gas Trap for the Space Station Internal Thermal Control System

The current dual-membrane gas trap is designed to remove non-condensed gases (NCG) from the Internal Thermal Control System (ITCS) coolant on board the International Space Station (ISS). To date it has successfully served its purpose of preventing depriming, overspeed, and shutdown of the ITCS pump. However, contamination in the ITCS coolant has adversely affected the gas venting rate and lifetime of the gas trap, warranting a development effort for a next-generation gas trap. Design goals are to meet or exceed the current requirements to (1) include greater operating ranges and conditions, (2) eliminate reliance on the current hydrophilic tube fabrication process, and (3) increase operational life and tolerance to particulate and microbial growth fouling. In addition, the next generation gas trap will essentially be a 'dropin" design such that no modifications to the ITCS pump package assembly (PPA) will be required, and the implementation of the new design will not affect changes to the ITCS operational conditions, interfaces, or software. This paper will present the initial membrane module design and development work which has included (1) a trade study among several conceptual designs, (2) performance modeling of a hydrophobic-only design, and (3) small-scale development test data for the hydrophobic-only design. Testing has shown that the hydrophobic-only design is capable of performing even better than the current dual-membrane design for both steady-state gas removal and gas slug removal.

Leimkuehler, Thomas O.↗

Overview of Loop Heat Pipe Operation

Loop heat pipes (LHP's) are two-phase heat transfer devices that utilize the evaporation and condensation of a working fluid to transfer heat, and the capillary forces developed in the porous wicks to circulate the fluid. The LHP was first developed in the former Soviet Union in the early 1980s, about the same time that the capillary pumped loop (CPL) was developed in the United States. The LHP is known for its high pumping capability and robust operation mainly due to the use of fine-pored metal wicks and an integral evaporator/hydro-accumulator design. The LHP technology is rapidly gaining acceptance in aerospace community. It is the baseline design for thermal control of several spacecraft, including NASA's GLAS and Chemistry, ESA's ATLID, CNES' STENTOR, RKA's OBZOR, and several commercial satellites. Numerous LHP papers have been published since the mid-1980's. Most papers presented test results and discussions on certain specific aspects of the LHP operation. LHP's and CPL's show many similarities in their operating principles and performance characteristics. However, they also display significant differences in many aspects of their operation. Some of the LHP behaviors may seem strange or mysterious, even to experienced CPL practitioners. The main purpose of this paper is to present a systematic description of the operating principles and thermal-hydraulic behaviors of LHP'S. LHP operating principles will be given first, followed by a description of the thermal-hydraulics involved in LHP operation. Operating characteristics and important parameters affecting the LHP operation will then be described in detail. Peculiar behaviors of the LHP, including temperature hysteresis and temperature overshoot during start-up, will be explained. For simplicity, most discussions will focus upon LHP's with a single evaporator and a single condenser, but devices with multiple evaporators and condensers will also be discussed. Similarities and differences between LHP's and CPL's will be addressed throughout the paper whenever appropriate.

Ku, Jentung↗

A Comparison of System Architectures for a Mechanically Pumped Two-Phase Thermal Control System

The NASA Jet Propulsion Laboratory is developing a mechanically pumped two-phase fluid loop thermal control system to enable novel mission designs and greater science return. Pumped two-phase fluid loops have the potential to provide robust and effective thermal control that combine the best aspects of passive two-phase systems (heat pipes) and mechanically pumped single-phase fluid loops. The current program requirements include the development of a system with multiple 1 sq.m evaporators, each of which is capable of remaining spatially and temporally isothermal while accommodating heat loads of up to 500 W and local fluxes of up to 5 W/sq.cm. The goal is to attain this using less than 5 W of power. Such a system would be able to accommodate the next generation of payload and bus electronics while using minimal resources. This paper compares two different mechanically pumped two-phase fluid loop architectures in the context of these requirements. A mixed flow and separated flow architecture are compared on a theoretical and experimental basis. Test data from sub-scale, single evaporator/single condenser, mixed flow and separated flow testbeds are presented. In addition, a model is introduced to better understand separated flow systems and some expressions for the theoretical performance limits of such systems are developed. To date, the investigation suggests that a separated flow architecture is better suited to the program requirements. Separated flow systems have the potential to accommodate an isothermalizing two-phase evaporator while using lower levels of power than would be required for a mixed flow system. In addition, it is argued that separated flow systems are more robust and amenable to analysis than mixed flow systems, since they significantly reduce the occurrence of two-phase flow by separating phases in the evaporator. Future work will include developing a full-scale testbed that includes multiple evaporators and condensers in a representative flight configuration.

Furst, Benjamin↗