Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Plasma Bubble Column Reactor: A High Throughput Reactor Design for Water Treatment

Plasma-based water treatment (PWT) is a promising technology that can degrade various emerging contaminants. However, PWT application on an industrially viable scale is hindered by the lack of an efficient reactor design that combines enhanced plasma-liquid contact with high liquid throughput. This work investigates the applicability of a bubble column gas-liquid contactor to PWT. A pulsed plasma bubble column reactor (PBCR) with a concentric rod-cylinder electrode configuration was used to correlate contaminant removal performance with the gas-liquid contact parameters of the bubble column. A surfactant, rhodamine B dye, and a nonsurfactant, caffeine, were used as model contaminants at µM concentration levels. The bubble column characteristics, i.e., gas holdup, bubble size distribution, and gas-liquid area, were measured as a function of superficial gas velocity using image-based methods. Degradation rates of both contaminants increased with gas flowrate. For caffeine, the increase was attributed to intensified bulk liquid mixing, while dye degradation increased due to the increased gas-liquid area. Ultimately, we show that bubble column contactors significantly improve the utilization of plasma-generated reactive species toward contaminant degradation by distributing them over a large contact area. As a result, a better match between the plasma species interfacial flux and the interfacial contaminant concentration leads to improved treatment energy efficiency. Furthermore, typical degradation energy efficiencies were ~10 g/kWh for caffeine and ~60 g/kWh for rhodamine B.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrodynamics of countercurrent flow in an additive-manufactured column with triply periodic minimal surfaces for carbon dioxide capture

Computational investigation of the countercurrent flows in an additively manufactured (AM) column packed with triply periodic minimal surface (TPMS) is challenging. Multiphase flow simulations using the volume of fluid (VOF) method can explain the column’s hydrodynamic characteristics, including interfacial area, liquid holdup, pressure drop, flow regime, etc. The interfacial area is a key factor dictating the mass transfer via the absorption process, and thereby the overall efficiency of the column. The impacts of a solvent's physical properties, liquid and gas loads, and contact angle on the hydrodynamics are extensively explored. The solvents include traditional solvent (monoethanolamine [MEA]) used in industry as well as a water-lean solvent (EEMPA) as prospective solvents for carbon capture. As expected, interfacial area and liquid holdup increase with increasing liquid loads (q L ). The EEMPA exhibits higher values for the interfacial area and liquid holdup compared to those for the MEA. The dry and wet pressure drops per unit length in the column at different gas loads (F G ) are calculated and further compared with the empirical correlations for traditional packings. At low gas loads, i.e., in the preloading regime, the predicted values of the wet and dry pressure drops match well with the corresponding values calculated from available correlations. The gas load has a marginal impact on the interfacial area at its lower value, but the higher value of F G (>2.18 $\sqrt{Pa}$) causes flooding in the column. The effect of varying contact angles on the interfacial area and liquid holdup in the preloading regime is also studied. Both interfacial area and liquid holdup decrease with the increase in the value of the contact angle. Altogether, the effect of the contact angle on interfacial area is more pronounced than other parameters influencing the interfacial area.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Void fraction, bubble size and interfacial area measurements in co-current downflow bubble column reactor with microbubble dispersion

Micro-bubbles dispersed in bubble column reactors have received great interest in recent years, due to their small size, stability, high gas-liquid interfacial area concentrations and longer residence times. The high gas-liquid interfacial area concentrations lead to high mass transfer rates compared to conventional bubble column reactors. In the present work, experiments have been performed in a down-flow bubble column reactor with micro-bubbles generated and dispersed by a novel mechanism to determine the gas-liquid interfacial area concentrations by measuring the void fraction and bubble size distributions. Gamma-ray densitometry has been employed to determine the axial and radial distributions of void fraction and a high speed camera equipped with a borescope is used to measure the axial and radial variations of bubble sizes. Also, the effects of superficial gas and liquid velocities on the two-phase flow characteristics have been investigated. Further, reconstruction techniques of the radial void fraction profiles from the gamma densitometry's chordal measurements are discussed and compared for a bubble column reactor with dispersed micro-bubbles. The results demonstrate that the new bubble generation technique offers high interfacial area concentrations (1,000 to 4,500 m 2 /m 3 ) with sub-millimeter bubbles (500 to 900 µm) and high overall void fractions (10% – 60%) in comparison with previous bubble column reactor designs. The void fraction data was analyzed using slip velocity model and empirical correlation has been proposed to predict the Sauter mean bubble diameter.

09 BIOMASS FUELS↗

New Method for Evaluating Irreversible Adsorption and Stationary Phase Bleed in Gas Chromatographic Capillary Columns

A novel method for the evaluation of gas chromatographic (GC) column inertness has been developed using a tandem GC approach. Typically column inertness is measured by analyte peak shape evaluation. In general, silica, glass, and metal surfaces are chemically reactive and can cause analyte adsorption, which typically is observed as chromatographic peak tailing. Adsorption processes produce broad, short chromatographic peaks that confound peak area determinations because a significant portion can reside in the noise. In addition, chromatographic surfaces and stationary phases can irreversibly adsorb certain analytes without obvious degradation of peak shape. The inertness measurements described in this work specifically determine the degree of irreversible adsorption behavior of specific target compounds at levels ranging from approximately 50 picograms to 1 nanogram on selected gas chromatographic columns. Chromatographic columns with 5% phenylmethylsiloxane, polyethylene glycol (wax), trifluoropropylsiloxane, and 78% cyanopropylsiloxane stationary phases were evaluated with a variety of phosphorus- and sulfur- containing compounds selected as test compounds due to their ease of adsorption and importance in trace analytical detection. In addition, the method was shown effective for characterizing column bleed.

bleed↗

Influence of porous aluminosilicate grain size materials in experimental and modelling Cs + adsorption kinetics and wastewater column process

This paper focuses on the influence of the grain size of a geopolymer based adsorbent on its Cs + adsorption performances both in batch and fixed-bed process. The geopolymer phase was used as a binder to support NaY zeolite particle in a 20 wt% charged porous composite with 160 m 2 .g –1 of porous surface area. These samples were shaped with three grain sizes (50 /100/500 µm) to remove 80–90 mg/g of Cs + in batch and column operations. After their microstructural and porous characterizations, their efficiency and adsorption characteristics were investigated through adsorption isotherms and kinetic in the two processes. While the grain size has no influence on the maximal extraction capacity of the adsorbent, it strongly affects the sorption kinetic. By coupling experimental data and a modelling approach, the complex sorption mechanism was highlighted, suggesting a new insight of the contaminant sorption kinetic. Then, comparison of batch and column adsorption experiments illustrates the detailed explanation of various process parameters for column study. The results show challenges for fixed-bed column utilization by the choice of the appropriate grain size as a compromise between the material sorption kinetic and hydrodynamic considerations. Furthermore, this is of high importance to more accurately optimize the design of column adsorption to assess the transport of Cs+ in multi-porous tailored grain size materials.

36 MATERIALS SCIENCE↗

Multiphase Large Eddy Simulation of a Pulsed Sieve-Plate Extraction Column - 18125

Presented here is research resulting from a framework of single-phase and multiphase modelling trials. These are intended to accurately simulate the internal flow phenomena arising in pulsed sieve-plate extraction columns representative of those found in industry. Three-dimensional unsteady flow calculations using large eddy simulation coupled with dynamic sub-grid scale modelling have been used to capture the transient effects of sinusoidal flow conditions using the open source CFD code OpenFOAM{sup R}. Multiphase interface interactions are modelled using the volume of fluid method with appropriate heavy and light phase fluidic properties capturing surface tension, density and viscous effects. The system studied consists of a 150 mm diameter column with two perforated plates with a fractional free area of 25 %, operational under 1 Hz pulsing frequency at a 50 mm amplitude and plate spacing of 300 mm. The materials simulated include water (single-phase) and 3 M nitric acid and dodecane / tributyl phosphate mixture at 30 vol% (multiphase). Results are compared with appropriate correlations from literature. The dispersive mixing efficiency of the system was also evaluated via a mixing index value which allows quantification of the ratio of rotational and irrotational flow components. This study has found that the predictive methods employed are effective at capturing the different scales of turbulence present within pulsed sieve-plate extraction columns, and its influence on their operation. As such, the work highlights the ability of large eddy simulation-based modelling to predict the complex flows in such column geometries. Furthermore, the techniques employed provide valuable insight into the hydrodynamic flow characteristics and mixing mechanisms arising within pulsed sieve-plate extraction columns. (authors)

42 ENGINEERING↗

Ion Exchange Column Thermal Modeling: Prevention of Process Effluent Boiling - 18577

The Savannah River Site treats and disposes of legacy high-level waste, which resulted from 60 years of nuclear material production, medical research, and other nuclear related work. Complex mixtures of soluble and insoluble solids occupy tanks of which the South Carolina Department of Health and Environmental Control recognizes as the single largest environmental risk state-wide. The risk is reduced through removal, treatment, and solidification of decontaminated salt waste. Presently, SRS decontaminates the soluble salt component of the waste, a solution containing actinides and cesium, via implementation of the Actinide Removal Process and the Modular Caustic Side Solvent- Extraction Unit. Caustic solvent extraction is set to increase in scale by late 2018, with startup of the newly constructed Salt Waste Processing Facility. In conjunction with Salt Waste Processing Facility startup, Savannah River Remediation has been tasked by the Department of Energy to demonstrate modular ion exchange technology. The Tank Closure Cesium Removal project aims to demonstrate the feasibility of modular ion exchange processes for future Department of Energy applications. The Tank Closure Cesium Removal system is scheduled to begin operation in mid-2018. Dissolved salt solution, or influent, will be fed through a filter and ion exchange columns in lead-lag configuration, producing effluent. The effluent is fed to a separate high-level waste tank, for future disposition at Salt-stone Production Facility. Once the demonstration project is complete, the loaded ion exchange columns will be purged, dried, and placed in interim safe storage, awaiting final disposition. The ion exchange media selected for the Tank Closure Cesium Removal system is Honeywell UOP IONSIV{sup C} R-9120. The media is a prime candidate for separation of cesium from radioactive high-level waste. UOP R-9120{sup C} is inorganic and has high capacity, selectivity, and affinity for cesium. During operation, influent is fed to the ion exchange columns, contacting UOP R-9210{sup C} packed within the media vessel. Contact initiates loading of isotopes, and given ample time the solid phase (ion exchange media) and solution achieve thermodynamic equilibrium. UOP R-9120{sup C} is a prime candidate for separation of cesium and dissolved fission products. Although the properties of UOP R-9120{sup C} are favorable for separation, the same properties lead to accumulation of a heat source in the ion exchange bed. Cesium-137 and its daughter product, barium-137 m, generate a clear majority of heat (i.e. ∼ 94%). During operation salt solution flows through each column and transports heat from the ion exchange bed. Once operation is terminated, the effluent contained within the porous bed volume becomes essentially static. In the absence of engineering controls, the heat generated may boil the effluent. Rapid vaporization of aqueous salt solution would lead to bed over pressurization. Over pressurization and an associated release of high-level waste would result in adverse impacts to human health and the environment. This paper focuses on modeling the heat transfer associated with the Tank Closure Cesium Removal system ion exchange column. The model evaluates the maximum heat generation and the associated radionuclide loadings that prevent boiling within of the media vessel, under no flow conditions. A safety significant control, maintaining loadings less than the established loading limit ensures associated impacts to human health and the environment are prevented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impacts of control strategies, the Great Recession and weekday variations on NO 2 columns above North American cities

The Ozone Monitoring Instrument (OMI) has been estimating NO2 columns from space for over 10 years, and these have been used to estimate emissions and emission trends for point and area sources all over the world. In this study we evaluate the trends in NO2 columns over 54 cities in the USA and Canada to identify the long term trends due to air quality policies, the impact of the Great Recession, and the weekday-weekend effect. A multiple linear regression model is used to fit annual, seasonal and weekly factors for individual swath retrievals along with the impact of temperature, wind speed and pixel size. For most cities, the correlation coefficients of the model fit ranges from 0.47 to 0.76. There have been strong reductions in NO2 columns, with annual decreases of up to 7% per year in most cities. During the years of the Great Recession, NO2 columns were as much as 30% lower than they would have been had they followed the linear annual trend. The analysis yielded insights into the timing of the reductions, with some cities in the northwest and in the east experiencing reductions in 2008 already, and most areas back to where they would have been based on the uniform trend by 2011. The analysis also finds that reductions in columns during the weekend vary significantly from city to city, with a range in reductions of 10%-30% on Saturdays, and 20%-50% on Sundays.

de Foy, Benjamin (ORCID:0000000341509922)↗

Photoluminescence emission at room temperature in zinc oxide nano-columns

Highlights: • ZnO nanoparticles were obtained by microwave-hydrothermal method. • X-ray diffraction reveals a hexagonal structure. • Photoluminescence emission evidenced two absorption peaks, at around 480 nm and 590 nm wavelengths. - Abstract: Hydrothermal microwave method (HTMW) was used to synthesize crystalline zinc oxide (ZnO) nano-columns at the temperature of 120 °C with a soaking time of 8 min. ZnO nano-columns were characterized by using X-ray analyses (XRD), infrared spectroscopy (FT-IR), thermogravimetric analyses (TG-DTA), field emission gun and transmission electron microscopy (FEG-SEM and TEM) and photoluminescence properties (PL). XRD results indicated that the ZnO nano-columns are free of any impurity phase and crystallize in the hexagonal structure. Typical FT-IR spectra for ZnO nano-columns presented well defined bands, indicating a substantial short-range order in the system. PL spectra consist of a broad band at 590 nm and narrow band at 480 nm corresponding to a near-band edge emission related to the recombination of excitons and level emission related to structural defects. These results show that the HTMW synthesis route is rapid, cost effective, and could be used as an alternative to obtain ZnO nano-columns in the temperature of 120 °C for 8 min.

36 MATERIALS SCIENCE↗

Hydrate Formation on Marine Seep Bubbles and the Implications for Water Column Methane Dissolution

Abstract Methane released from seafloor seeps contributes to a number of benthic, water column, and atmospheric processes. At seafloor seeps within the methane hydrate stability zone, crystalline gas hydrate shells can form on methane bubbles while the bubbles are still in contact with the seafloor or as the bubbles begin ascending through the water column. These shells reduce methane dissolution rates, allowing hydrate‐coated bubbles to deliver methane to shallower depths in the water column than hydrate‐free bubbles. Here, we analyze seafloor videos from six deepwater seep sites associated with a diverse range of bubble‐release processes involving hydrate formation. Bubbles that grow rapidly are often hydrate‐free when released from the seafloor. As bubble growth slows and seafloor residence time increases, a hydrate coating can form on the bubble's gas‐water interface, fully coating most bubbles within ∼10 s of the onset of hydrate formation at the seafloor. This finding agrees with water‐column observations that most bubbles become hydrate‐coated after their initial ∼150 cm of rise, which takes about 10 s. Whether a bubble is coated or not at the seafloor affects how much methane a bubble contains and how quickly that methane dissolves during the bubble's rise through the water column. A simplified model shows that, after rising 150 cm above the seafloor, a bubble that grew a hydrate shell before releasing from the seafloor will have ∼5% more methane than a bubble of initial equal volume that did not grow a hydrate shell after it traveled to the same height.

54 ENVIRONMENTAL SCIENCES↗

Modeling of column apparatuses: A review

This paper presents a review of the modeling method on the base of the physical approximations of the mechanics of continua, which have been developed for processes in column apparatuses. This method includes diffusion type of model for modeling of mass transfer with chemical reaction in column apparatuses with and without circulation zones. The diffusion type of model is used for modeling of scale effect in column apparatuses too. The study concluded that the proposal method is possibility for investigation the influence of radial non uniformity of the velocity distribution on the process efficiency, influence of zones breadths on the mass transfer efficiency in the column. The method of the column apparatuses modeling can be used for modeling of physical and chemical absorption, chemical adsorption, homogeneous and heterogeneous (catalytic) chemical reactions, airlift reactors for chemical and photochemical reactions.

42 ENGINEERING↗

Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing the single camera image), we provide here a 3D data analysis that includes 3D reconstructions of the plasma column and 3D particle tracking velocimetry based on discrete tomography methods. The 3D analysis, in particular, the determination of the 3D slip velocity between the plasma column and the gas flow, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius of the conducting zone of the plasma column.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Regenerated silica gel as stationary phase on vacuum column chromatography to purify temulawak’s extracts

Commercial silica gel only used once by many researchers and affected high cost for purification process, also less support the green chemistry program. This research focused in regeneration silica gel that used purification of temulawak’s extracts (Curcuma xanthorrhiza Roxb) by vacuum column chromatography. Sample extracts (contains 10.1195±0.5971% of curcuminoids) was purified by vacuum column chromatography (pressure: 45 kPa, column: 100mm on length and 16mm on diameter). Ethanol 96% and acetone were compared as eluent. The amount of solvent and yield of curcuminoids used as indicator purification. The silica gel was regenerated with heating in 600°C for 8 hours The silica gels were analyzed by IR spectroscopy and X-ray diffraction. Furthermore, regenerated silica gel was used as the stationary phase in vacuum column chromatography under the same conditions with the previous purification. All the purification experiments were performed in three repetitions. Based on regression equation, y=0.132x+0.0011 (r{sup 2}=0.9997) the yield of curcuminoids on purified products using ethanol as the eluent was improved 4.26% (to 14.3724±0.5749%) and by acetone was improved 3,03% (to 13.1450 ±0.6318%). The IR spectrum of both silica gel showed the same vibration profile and also there were three crystallinity peaks missing on its X-ray diffraction. Regenerated silica gel has the same performance with new silica gel in purification of temulawak’s extract: by ethanol has increased 4.08% (14.1947±0.7415%) and 2.93% (13.0447±0.4822) by acetone. In addition, all purification products showed similar TLC profiles. Purification using regenerated silica gel as the adsorbent on vacuum column chromatography has exactly same potential with the new silica gel.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temporal structure of an electric signal produced upon interaction of radiation from a HF laser with the bottom surface of a water column

Generation of an electric signal is investigated when a HF-laser pulse interacts with the lower surface of a water column in a cell with a bottom transparent to laser radiation, while the upper surface of the water column remains open. The electric signal exhibits a temporal structure of two spikes spaced by time {tau} which is linearly dependent on the laser output energy. It is found that the value of {tau} (up to 1.3 ms) is an order of magnitude greater than the time during which the vapour pressure in a cavity produced due to the volume explosive boiling of water in the exposed area is greater than the atmospheric pressure. The second spike was determined to appear upon the collapse of the vapour cavity. A mathematical model is constructed that explains the motion of the water column above the vapour cavity taking into account the temporal evolution of the vapour pressure above it. It is shown that the prolonged lifetime of the vapour cavity after the decrease in the vapour pressure down to the atmospheric value is caused by the inertial motion of the water column acquiring the velocity at the initial stage of the cavity expansion. The calculated time of the water column motion agrees well with the experimental time interval between the spikes of an electric signal. (interaction of laser radiation with matter)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TRACING H{sub 2} COLUMN DENSITY WITH ATOMIC CARBON (C I) AND CO ISOTOPOLOGS

We present the first results of neutral carbon ([C I] {sup 3} P {sub 1}-{sup 3} P {sub 0} at 492 GHz) and carbon monoxide ({sup 13}CO, J = 1-0) mapping in the Vela Molecular Ridge cloud C (VMR-C) and the G333 giant molecular cloud complexes with the NANTEN2 and Mopra telescopes. For the four regions mapped in this work, we find that [C I] has very similar spectral emission profiles to {sup 13}CO, with comparable line widths. We find that [C I] has an opacity of 0.1-1.3 across the mapped region while the [C I]/{sup 13}CO peak brightness temperature ratio is between 0.2 and 0.8. The [C I] column density is an order of magnitude lower than that of {sup 13}CO. The H{sub 2} column density derived from [C I] is comparable to values obtained from {sup 12}CO. Our maps show that C I is preferentially detected in gas with low temperatures (below 20 K), which possibly explains the comparable H{sub 2} column density calculated from both tracers (both C I and {sup 12}CO underestimate column density), as a significant amount of the C I in the warmer gas is likely in the higher energy state transition ([C I] {sup 3} P {sub 2}-{sup 3} P {sub 1} at 810 GHz), and thus it is likely that observations of both the above [C I] transitions are needed in order to recover the total H{sub 2} column density.

79 ASTRONOMY AND ASTROPHYSICS↗

Evenly spaced columns in the Bishop Tuff (California, USA) as relicts of hydrothermal cooling

A few square kilometers of the Bishop Tuff in eastern California (USA) have evenly spaced columns that are more resistant to erosion than the surrounding tuff owing to the precipitation of mordenite, a low-temperature (100-130 °C) zeolite. We hypothesize that the columns are a result of instabilities at the liquid water and steam interface as cold water seeped into the still-cooling Bishop Tuff. We use two methods to quantitatively assess this hypothesis. First, scaling shows which hydrodynamic instabilities exist in the system. Second, to account for the effects of multiphase flow, latent heat, and the finite amplitude and temporal evolution of these instabilities we use two-dimensional numerical models of liquid water infiltrating hot tuff. These tests highlight several features of boiling hydrothermal systems. (1) The geometry of at least some convection appears to be broadly captured by linear stability theory that neglects reactive transport, heterogeneity of the host rock, and the finite amplitude of instabilities. (2) Slopes > 10% set the wavelength of convection, meaning that these columns formed somewhere with relatively gentle topography. (3) For permeabilities of > 10 -13 m 2 , the wavelength of the instability changes through time, slowing infiltration, while for permeabilities < 10 -15 m 2 , cooling is dominated by conduction. The spacing and stability of columns increase with higher vertical permeability and decrease with higher horizontal permeability. These columns are a rare window into hydrothermal processes that may be widespread.

58 GEOSCIENCES↗

Small-Column Cesium Ion Exchange Elution Testing of Spherical Resorcinol-Formaldehyde

This report summarizes the work performed to evaluate multiple, cesium loading, and elution cycles for small columns containing SRF resin using a simple, high-level waste (HLW) simulant. Cesium ion exchange loading and elution curves were generated for a nominal 5 M Na, 2.4E-05 M Cs, 0.115 M Al loading solution traced with 134 Cs followed by elution with variable HNO 3 (0.02, 0.07, 0.15, 0.23, and 0.28 M) containing variable CsNO 3 (5.0E-09, 5.0E-08, and 5.0E-07 M) and traced with 137 Cs. The ion exchange system consisted of a pump, tubing, process solutions, and a single, small (~15.7 mL) bed of SRF resin with a water-jacketed column for temperature-control. The columns were loaded with approximately 250 bed volumes (BVs) of feed solution at 45°C and at 1.5 to 12 BV per hour (0.15 to 1.2 cm/min). The columns were then eluted with 29+ BVs of HNO 3 processed at 25°C and at 1.4 BV/h. The two independent tracers allowed analysis of the on-column cesium interaction between the loading and elution solutions. The objective of these tests was to improve the correlation between the spent resin cesium content and cesium leached out of the resin in subsequent loading cycles (cesium leakage) to help establish acid strength and purity requirements.

74 ATOMIC AND MOLECULAR PHYSICS↗

Documenting Dual-Column Experiment with Mini-SHINE Solution

Argonne National Laboratory (Argonne) is assisting SHINE Medical Technologies (SHINE) in developing a production method and recovery and purification processes for molybdenum 99 (Mo-99) using an accelerator-driven, subcritical target consisting of an aqueous uranyl-sulfate solution. An integral part of the process is the development of a column for the separation and recovery of Mo-99, followed by a concentration column to reduce the product volume from 15–25 L to <1 L prior to entry into the low-enriched uranium (LEU)-Modified Cintichem purification process. Argonne has developed plant-scale column designs for the initial Mo-recovery column and the concentration column.

Stepinski, Dominique C.↗