Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Installation of the Pulse-Plate Column Pilot Plant

There are three primary types of solvent extraction equipment utilized in the nuclear industry for reprocessing of used nuclear fuel; pulse columns, mixer-settlers, and centrifugal contactors. Considerable research and development has been performed at the INL and throughout the DOE complex on the application of centrifugal contactors for used fuel reprocessing and these contactors offer many significant advantages. However, pulse columns have been used extensively in the past in throughout the world for aqueous separations processes and remain the preferred equipment by many commercial entities. Therefore, a pulse-plate column pilot plant has been assembled as part of the Advanced Fuel Cycle Initiative to support experimentation and demonstration of pulse column operation. This will allow the training of personnel in the operation of pulse columns. Also, this capability will provide the equipment to allow for research to be conducted in the operation of pulse columns with advanced solvents and processes developed as part of the fuel cycle research and development being performed in the AFCI program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Complete temperature profiles in ultra-high pressure liquid chromatography columns

The temperature profiles were calculated along and across seven packed columns (lengths 30, 50, 100, and 150 mm, i.d., 1 and 2.1 mm, all packed with Acquity UPLC, BEH-C{sub 18} particles, average d{sub p} {approx} 1.7 {micro}m) and their stainless steel tubes (o.d. 4.53 and 6.35 mm). These columns were kept horizontal and sheltered from forced air convection (i.e., under still air conditions), at room temperature. They were all percolated with pure acetonitrile, either under the maximum pressure drop (1034 bar) or at the maximum flow rate (2 mL/min) permitted by the chromatograph. The heat balance equation of chromatographic columns was discretized and solved numerically with minimum approximation. Both the compressibility and the thermal expansion of the eluent were taken into account. The boundary conditions were determined from the experimental measurements of the column inlet pressure and of the temperature profile along the column wall, which were made with a precision better than {+-}0.1 K. These calculation results provide the 3-D temperature profiles along and across the columns. The axial and radial temperature gradients are discussed in relationship with the experimental conditions used. The temperature map obtained permits a prediction of the chromatographic data obtained under a very high pressure gradient.

36 MATERIALS SCIENCE↗

Relationship Between Column-Density and Surface Mixing Ratio: Statistical Analysis of O3 and NO2 Data from the July 2011 Maryland DISCOVER-AQ Mission

To investigate the ability of column (or partial column) information to represent surface air quality, results of linear regression analyses between surface mixing ratio data and column abundances for O3 and NO2 are presented for the July 2011 Maryland deployment of the DISCOVER-AQ mission. Data collected by the P-3B aircraft, ground-based Pandora spectrometers, Aura/OMI satellite instrument, and simulations for July 2011 from the CMAQ air quality model during this deployment provide a large and varied data set, allowing this problem to be approached from multiple perspectives. O3 columns typically exhibited a statistically significant and high degree of correlation with surface data (R(sup 2) > 0.64) in the P- 3B data set, a moderate degree of correlation (0.16 < R(sup 2) < 0.64) in the CMAQ data set, and a low degree of correlation (R(sup 2) < 0.16) in the Pandora and OMI data sets. NO2 columns typically exhibited a low to moderate degree of correlation with surface data in each data set. The results of linear regression analyses for O3 exhibited smaller errors relative to the observations than NO2 regressions. These results suggest that O3 partial column observations from future satellite instruments with sufficient sensitivity to the lower troposphere can be meaningful for surface air quality analysis.

nitrogen dioxide↗

Influence of the Physical Properties of Liquids and Diameter of Bubble on the Formation of Liquid Column at the Interface of Two Liquid Phases by the Rising Bubble

The formation of metal emulsion in a steel-making process enhances the reaction between metal and slag. A part of the metal emulsion is formed by a bubble passing through the interface between the metal and slag phases. In a previous study, it was determined that the formation of metal column by the bubble is related to the formation of metal droplets. In this research, the effects of bubble particle size, interfacial tension, viscosity of upper layer, and lower layer density on the formation of lower liquid column were investigated. In order to conduct an in situ observation of gas and liquid behaviors, aqueous solution and silicon oil systems were employed. It was determined that a narrow and elongated column forms liquid droplets in the upper liquid layer and contributes to the formation of droplets. The height of the column and the volume of droplets increase with the increase in bubble size. The influence of interfacial tension of the two liquid phases on the column height and the formation of droplet is slight. The height of the formed column decreases with the increase in the density of lower liquid.

36 MATERIALS SCIENCE↗

Selective Retention of Explosives and Related Compounds on Gas-Chromatographic Capillary Columns Coated with Lanthanide(III) ß-diketonate Polymers

The purpose of this research was to investigate coating capillary columns with lanthanide(III) beta-diketonate polymers to provide gas-chromatographic columns with selectivity toward explosives and related compounds. Capillary columns were statically coated with a combination of a lanthanide(III) beta-diketonate polymer, which utilized p-di(4,4,5,5,6,6,6-heptafluoro-1,3-hexanedionyl)benzene (dihed) as a ligand, and SE-30. A novel coating technique was developed that used a methanol-containing azeotrope to provide solubility for both polymers while maintaining a low boiling point compatible with static coating. As based on temperature-programmed retention indices, the custom experimental columns displayed selective retention of nitroaromatic, nitroalkane, and nitrate ester test probes relative to an appropriate SE-30 control column. Selective retention was more pronounced for strong Lewis base analytes (i.e., cyclohexanone). Relative analyte retention on the La(dihed), Tb(dihed) and Eu(dihed) columns are discussed relative to Lewis acidity and solubility of the polymer in the azeotrope coating solution.

36 MATERIALS SCIENCE↗

Physical properties and structure of fine core-shell particles used as packing materials for chromatography relationships between particle characteristics and column performance

The recent development of new brands of packing materials made of fine porous-shell particles, e.g., Halo and Kinetex, has brought great improvements in potential column efficiency, demanding considerable progress in the design of chromatographic instruments. Columns packed with Halo and Kinetex particles provide minimum values of their reduced plate heights of nearly 1.5 and 1.2, respectively. These packing materials have physical properties that set them apart from conventional porous particles. The kinetic performance of 4.6 mm I.D. columns packed with these two new materials is analyzed based on the results of a series of nine independent and complementary experiments: low-temperature nitrogen adsorption (LTNA), scanning electron microscopy (SEM), inverse size-exclusion chromatography (ISEC), Coulter counter particle size distributions, pycnometry, height equivalent to a theoretical plate (HETP), peak parking method (PP), total pore blocking method (TPB), and local electrochemical detection across the column exit section (LED). The results of this work establish links between the physical properties of these superficially porous particles and the excellent kinetic performance of columns packed with them. It clarifies the fundamental origin of the difference in the chromatographic performances of the Halo and the Kinetex columns.

36 MATERIALS SCIENCE↗

Comparative uptake, translocation, and plant mediated transport of Tc-99, Cs-133, Np-237, and U-238 in Savannah River Site soil columns for the grass species Andropogon virginicus

Here, this study examines the ability of the grass species Andropogon virginicus to alter the subsurface transport and redistribution of a suite of radionuclides ( 99 Tc, 133 Cs (stable analog for 135 Cs and 137 Cs), 237 Np, 238 U) with varying chemical behaviors in a Savannah River Site soil via the use of vegetated and unvegetated soil columns. After an acclimation period, a small volume of solution containing all radionuclides was introduced into the columns via Rhizon© pore water sampling tubes. Plants were grown for an additional 4 weeks before shoots were harvested, and columns were prepared for sampling. Plant presence led to decreased radionuclide release from the columns, mainly due to radionuclide specific combinations of system hydrology differences resulting from plant transpiration as well as plant uptake. For the most mobile radionuclides, 99 Tc followed by 237 Np, plant presence resulted in significantly different soil concentration profiles between vegetated and unvegetated columns, including notable upward migration for 237 Np in columns with plants. Additionally, plant uptake of 99 Tc was the greatest of all the radionuclides, with plant tissues containing an average of 44 % of the 99 Tc, while plant uptake only accounted for <2 % of 237 Np and <0.5 % of 133 Cs and 238 U in the system. Although overall plant uptake of 133 Cs and 238 U were similar, the majority of 133 Cs taken up by plants was associated with 133 Cs already available in the aqueous phase while 238 U uptake was mainly associated with the solid phase, meaning that plant activity resulted in a fraction of the native 238 U being mobilized and thus, made available for plant uptake. Overall, this study quantified the influence of several plant-mediated physical and biogeochemical factors that have significant influence on radionuclide mobility and transport in this complex system which can be further utilized in future system or site-specific environmental transport and risk assessment models.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of Designs of Hydrogen Isotope Separation Columns by Numerical Modeling

Mixtures of gas-phase hydrogen isotopologues (diatomic combinations of protium, deuterium, and tritium) can be separated using columns containing a solid such as palladium that reversibly absorbs hydrogen. A temperature-swing process can transport hydrogen into or out of a column by inducing temperature-dependent absorption or desorption reactions. Here, we consider two designs: a thermal cycling absorption process, which moves hydrogen back and forth between two columns, and a simulated moving bed (SMB), where columns are in a circular arrangement. We present a numerical mass and heat transport model of absorption columns for hydrogen isotope separation. It includes a detailed treatment of the absorption–desorption reaction for palladium. By comparing the isotope concentrations within the columns as a function of position and time, we observe that SMB can lead to sharper separations for a given number of thermal cycles by avoiding the remixing of isotopes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlling the column spacing in isothermal magnetic advection to enable tunable heat and mass transfer

Isothermal magnetic advection (IMA) is a recently discovered method of inducing highly organized, non-contact flow lattices in suspensions of magnetic particles, using only uniform ac magnetic fields of modest strength. The initiation of these vigorous flows requires neither a thermal gradient nor a gravitational field, and so can be used to transfer heat and mass in circumstances where natural convection does not occur. These advection lattices are comprised of a square lattice of antiparallel flow columns. If the column spacing is sufficiently large compared to the column length and the flow rate within the columns is sufficiently large, then one would expect efficient transfer of both heat and mass. Otherwise, the flow lattice could act as a countercurrent heat exchanger and only mass will be efficiently transferred. Although this latter case might be useful for feeding a reaction front without extracting heat, it is likely that most interest will be focused on using IMA for heat transfer. In this paper, we explore the various experimental parameters of IMA to determine which of these can be used to control the column spacing. These parameters include the field frequency, strength, and phase relation between the two field components, the liquid viscosity, and particle volume fraction. Finally, we find that the column spacing can easily be tuned over a wide range to enable the careful control of heat and mass transfer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Inorganic Microsphere Composite for the Selective Removal of 137 Cesium from Acidic Nuclear Waste Solutions 2: Bench-Scale Column Experiments, Modeling, and Preliminary Process Design

A new inorganic ion exchange composite for removing radioactive cesium from acidic waste streams has been developed. The new material consists of ammonium molybdophosphate, (NH4)3P(Mo3O10)4?3H2O (AMP), synthesized within hollow aluminosilicate microspheres (AMP-C), which are produced as a by-product from coal combustion. The selective cesium exchange capacity of this inorganic composite was evaluated in bench-scale column tests using simulated sodium bearing waste solution as a surrogate for the acidic tank waste currently stored at the Idaho National Laboratory (INL). Total cesium loading on the columns at saturation agreed very well with equilibrium values predicted from isotherm experiments performed previously. A numerical algorithm for solving the governing partial differential equations (PDE) for cesium uptake was developed using the intraparticle mass transfer coefficient obtained from previous batch kinetic experiments. Solutions to the governing equations were generated to obtain the cesium concentration at the column effluent as a function of throughput volume using the same conditions as those used for the actual column experiments. The numerical solutions of the PDE fit the column break through data quite well for all the experimental conditions in the study. The model should therefore provide a reliable prediction of column performance at larger scales.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

H I-to-H{sub 2} transitions and H I column densities in galaxy star-forming regions

We present new analytic theory and radiative transfer computations for the atomic-to-molecular (H I-to-H{sub 2}) transitions and the buildup of atomic hydrogen (H I) gas columns in optically thick interstellar clouds irradiated by far-UV (FUV) photodissociating radiation fields. We derive analytic expressions for the total H I column densities for (one-dimensional (1D)) planar slabs, for beamed or isotropic radiation fields, from the weak- to strong-field limits, for gradual or sharp atomic-to-molecular transitions, and for arbitrary metallicity. Our expressions may be used to evaluate the H I column densities as functions of the radiation field intensity and the H{sub 2}-dust-limited dissociation flux, the hydrogen gas density, and the metallicity-dependent H{sub 2} formation rate coefficient and FUV dust grain absorption cross section. We make the distinction between 'H I-dust' and 'H{sub 2}-dust' opacity, and we present computations for the 'universal H{sub 2}-dust-limited effective dissociation bandwidth'. We validate our analytic formulae with Meudon PDR code computations for the H I-to-H{sub 2} density profiles and total H I column densities. We show that our general 1D formulae predict H I columns and H{sub 2} mass fractions that are essentially identical to those found in more complicated (and approximate) spherical (shell-core) models. We apply our theory to compute H{sub 2} mass fractions and star-formation thresholds for individual clouds in self-regulated galaxy disks, for a wide range of metallicities. Our formulae for the H I columns and H{sub 2} mass fractions may be incorporated into hydrodynamics simulations for galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

FAR-INFRARED DUST TEMPERATURES AND COLUMN DENSITIES OF THE MALT90 MOLECULAR CLUMP SAMPLE

We present dust column densities and dust temperatures for ∼3000 young, high-mass molecular clumps from the Millimeter Astronomy Legacy Team 90 GHz survey, derived from adjusting single-temperature dust emission models to the far-infrared intensity maps measured between 160 and 870 μm from the Herschel/Herschel Infrared Galactic Plane Survey (Hi-Gal) and APEX/APEX Telescope Large Area Survey of the Galaxy (ATLASGAL) surveys. We discuss the methodology employed in analyzing the data, calculating physical parameters, and estimating their uncertainties. The population average dust temperature of the clumps are 16.8 ± 0.2 K for the clumps that do not exhibit mid-infrared signatures of star formation (quiescent clumps), 18.6 ± 0.2 K for the clumps that display mid-infrared signatures of ongoing star formation but have not yet developed an H ii region (protostellar clumps), and 23.7 ± 0.2 and 28.1 ± 0.3 K for clumps associated with H ii and photo-dissociation regions, respectively. These four groups exhibit large overlaps in their temperature distributions, with dispersions ranging between 4 and 6 K. The median of the peak column densities of the protostellar clump population is 0.20 ± 0.02 g cm{sup −2}, which is about 50% higher compared to the median of the peak column densities associated with clumps in the other evolutionary stages. We compare the dust temperatures and column densities measured toward the center of the clumps with the mean values of each clump. We find that in the quiescent clumps, the dust temperature increases toward the outer regions and that these clumps are associated with the shallowest column density profiles. In contrast, molecular clumps in the protostellar or H ii region phase have dust temperature gradients more consistent with internal heating and are associated with steeper column density profiles compared with the quiescent clumps.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-369: Evaluating Intensity Modulated Proton Therapy Relative to Passive Scattering Proton Therapy for Increased Vertebral Column Sparing in CSI of Pediatric Patients

Purpose: To investigate the trade-off between vertebral column sparing and thecal-sac target coverage in craniospinal irradiation (CSI) of pediatric patients treated with passive-scattering (PS) and intensity modulated (IMPT) proton therapy. Methods: We selected 2 pediatric patients treated with PS CSI for medulloblastoma. Spinal irradiation was re-planned with IMPT. For all cases, we assumed prescription dose of 23.4 Gy(RBE), with the spinal canal receiving at least 95% of 23.4 Gy(RBE). PS planning was performed using the commercial system XiO. IMPT planning was done using the Astroid planning system. Beam arrangements consisted of (a) PS posterior-anterior (PA) field, PS-PA, (b) IMPT PA field, IMPT-PA, and (c) two posterior oblique IMPT fields, IMPT2 (-35°, 35°). Dose distributions were re-calculated using TOPAS Monte Carlo, along with LET distributions, to investigate LET variations within the target and vertebra anatomy. Variable RBE-weighed dose distributions were also calculated based on a dose and LET-dependent biophysical model. Dosimetric data were compared among the plans for the target volume, spinal cord and adjacent critical organs (thecal-sac and cauda equina). Results: IMPT2 resulted in better sparing of the posterior vertebral column (entrance region posterior to thecal-sac), where planned dose was approximately 6–8Gy(RBE). For IMPT-PA and PS-PA the MC-calculated dose to the posterior vertebral column was, on average, 20Gy and 18Gy respectively. For IMPT2 higher mean-LET (5keV/µm/(g/cm3)) values were observed in anterior vertebral column (beyond the thecal-sac) relative to IMPT-PA and PS-PA, where mean-LET was 3.5keV/µm/(g/cm3) and 2.5keV/µm/(g/cm3) respectively. The higher LET region observed for both IMPT plans was in the distal end of treatment fields, where dose delivered was less 5Gy(RBE). Conclusion: The two-oblique proton beams IMPT2 best spared the spinal column, while reducing the dose to the posterior spinal column from 18–20 to 6–8 Gy(RBE). The best LET distribution was obtained with the PS-PA fields.

60 APPLIED LIFE SCIENCES↗

Method for Controlling Temperature Profiles and Water Table Depths in Laboratory Sediment Columns

Core Ideas Column experiments simulating subsurface environments require control of temperature profiles. A 2‐m‐tall laboratory sediment column reproduced vadose zone thermal and hydraulic conditions. Measured CO 2 profiles show the importance of microbial respiration below the root zone. Transport from the soil surface to groundwater is commonly mediated through deeper portions of the vadose zone and capillary fringe, where variations in temperature and water saturation strongly influence biogeochemical processes. This technical note describes a sediment column design that allows laboratory simulation of thermal and hydrologic conditions found in many field settings. Temperature control is particularly important because room temperature is not representative of most subsurface environments. A 2.0‐m‐tall column was capable of simulating profiles with temperatures ranging from 3 to 22°C, encompassing the full range of seasonal temperature variation observed in the deep vadose zone and capillary fringe of a semiarid floodplain in western Colorado. The water table was varied within the lower 0.8‐m section of the column, and profiles of water content and matric potential were measured. Vadose zone CO 2 collected from depth‐distributed gas samplers under representative seasonal conditions reflected the influences of temperature and water table depth on microbial respiration. Thus, realistic subsurface biogeochemical dynamics can be simulated in the laboratory through establishing column profiles that represent seasonal thermal and hydrologic conditions.

54 ENVIRONMENTAL SCIENCES↗

Application of Column Extraction Method for Impurities Analysis on HB-Line Plutonium Oxide in Support of MOX Feed Product Specifications

The current mission at H-Canyon involves the dissolution of an Alternate Feedstocks 2 (AFS-2) inventory that contains plutonium metal. Once dissolved, HB-Line is tasked with purifying the plutonium solution via anion exchange, precipitating the Pu as oxalate, and calcining to form plutonium oxide (PuO 2 ). The PuO 2 will provide feed product for the Mixed Oxide (MOX) Fuel Fabrication Facility, and the anion exchange raffinate will be transferred to H-Canyon. The results presented in this report document the potential success of the RE resin column extraction application on highly concentrated Pu samples to meet MOX feed product specifications. The original 'Hearts Cut' sample required a 10000x dilution to limit instrument drift on the ICP-MS method. The instrument dilution factors improved to 125x and 250x for the sample raffinate and sample eluent, respectively. As noted in the introduction, the significantly lower dilutions help to drop the total MRL for the analyte. Although the spike recoveries were half of expected in the eluent for several key elements, they were between 94-98% after Nd tracer correction. It is seen that the lower ICD limit requirements for the rare earths are attainable because of less dilution. Especially important is the extremely low Ga limit at 0.12 μg/g Pu; an ICP-MS method is now available to accomplish this task on the sample raffinate. While B and V meet the column A limits, further development is needed to meet the column B limits. Even though V remained on the RE resin column, an analysis method is ready for investigation on the ICP-MS, but it does not mean that V cannot be measured on the ICP-ES at a low dilution to meet the column B limits. Furthermore, this column method can be applicable for ICP-ES as shown in Table 3-2, in that it trims the sample of Pu, decreasing and sometimes eliminating Pu spectral interferences.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-Column Xe/Kr Separation with AgZ-PAN and HZ-PAN

Previous multi-column xenon/krypton separation tests have demonstrated the capability of separating xenon from krypton in a mixed gas feed stream. The results of this initial testing with AgZ-PAN and HZ-PAN indicated that an excellent separation of xenon from krypton could be achieved. Building upon these initial results, a series of additional multi-column testing were performed in FY-16. The purpose of this testing was to scale up the sorbent beds, test a different composition of feed gas and attempt to improve the accuracy of the analysis of the individual capture columns’ compositions. Two Stirling coolers were installed in series to perform this testing. The use of the coolers instead of the cryostat provided two desired improvements, 1) removal of the large dilution due to the internal volume of the cryostat adsorption chamber, and 2) ability to increase the sorbent bed size for scale-up. The AgZ-PAN sorbent, due to its xenon selectivity, was loaded in the first column to capture the xenon while allowing the krypton to flow through and be routed to a second column containing the HZ-PAN for capture and analysis. The gases captured on both columns were sampled with evacuated sample bombs and subsequently analyzed via GC-MS for both krypton and xenon. The results of these tests can be used to develop the scope of future testing and analysis using this test bed for demonstrating the capture and separation of xenon and krypton using sorbents, for demonstrating desorption and regeneration of the sorbents, and for determining compositions of the desorbed gases. They indicate a need for future desorption studies in order to better quantify co-adsorbed species and final krypton purity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Maximum Potential Hydrogen Gas Retention in the sRF Resin Ion Exchange Column for the LAWPS Process

The Low-Activity Waste Pretreatment System (LAWPS) is being developed to provide treated supernatant liquid from the Hanford tank farms directly to the Low-Activity Waste (LAW) Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant. The design and development of the LAWPS is being conducted by Washington River Protection Solutions, LLC. A key process in LAWPS is the removal of radioactive Cs in ion exchange (IX) columns filled with spherical resorcinol-formaldehyde (sRF) resin. One accident scenario being evaluated is the loss of liquid flow through the sRF resin bed after it has been loaded with radioactive Cs and hydrogen gas is being generated by radiolysis. In normal operations, the generated hydrogen is expected to remain dissolved in the liquid and be continuously removed by liquid flow. For an accident scenario with a loss of flow, hydrogen gas can be retained within the IX column both in the sRF resin and below the bottom screen that supports the resin within the column. The purpose of this report is to summarize calculations that estimate the upper-bound volume of hydrogen gas that can be retained in the column and potentially be released to the headspace of the IX column or to process equipment connected to the IX column and, thus, pose a flammability hazard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Attenuating Sulfidogenesis in a Soured Continuous Flow Column System With Perchlorate Treatment

Hydrogen sulfide production by sulfate reducing bacteria (SRB) is the primary cause of oil reservoir souring. Amending environments with chlorate or perchlorate [collectively denoted (per)chlorate] represents an emerging technology to prevent the onset of souring. Recent studies with perchlorate reducing bacteria (PRB) monocultures demonstrated that they have the innate capability to enzymatically oxidize sulfide, thus PRB may offer an effective means of reversing souring. (Per)chlorate may be effective by (i) direct toxicity to SRB; (ii) competitive exclusion of SRB by PRB; or (iii) reversal of souring through re-oxidation of sulfide by PRB. To determine if (per)chlorate could sweeten a soured column system and assign a quantitative value to each of the mechanisms we treated columns flooded with San Francisco bay water with temporally decreasing amounts (50, 25, and 12.5 mM) of (per)chlorate. Geochemistry and the microbial community structure were monitored and a reactive transport model was developed, Results were compared to columns treated with nitrate or untreated. Souring was reversed by all treatments at 50 mM but nitrate-treated columns began to re-sour when treatment concentrations decreased (25 mM). Re-souring was only observed in (per)chlorate-treated columns when concentrations were decreased to 12.5 mM and the extent of re-souring was less than the control columns. Microbial community analyses indicated treatment-specific community shifts. Nitrate treatment resulted in a distinct community enriched in genera known to perform sulfur cycling metabolisms and genera capable of nitrate reduction. (Per)chlorate treatment enriched for (per)chlorate reducing bacteria. (Per)chlorate treatments only enriched for sulfate reducing organisms when treatment levels were decreased. A reactive transport model of perchlorate treatment was developed and a baseline case simulation demonstrated that the model provided a good fit to the effluent geochemical data. Subsequent simulations teased out the relative role that each of the three perchlorate inhibition mechanisms played during different phases of the experiment. These results indicate that perchlorate addition is an effective strategy for both souring prevention and souring reversal. It provides insight into which organisms are involved, and illuminates the interactive effects of the inhibition mechanisms, further highlighting the versatility of perchlorate as a sweetening agent.

02 PETROLEUM↗