Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coaxial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Combustion and Performance Analyses of Coaxial Element Injectors with Liquid Oxygen/Liquid Methane Propellants

Liquid rocket engines using oxygen and methane propellants are being considered by the National Aeronautics and Space Administration (NASA) for in-space vehicles. This propellant combination has not been previously used in a flight-qualified engine system, so limited test data and analysis results are available at this stage of early development. NASA has funded several hardware-oriented activities with oxygen and methane propellants over the past several years with the Propulsion and Cryogenic Advanced Development (PCAD) project, under the Exploration Technology Development Program. As part of this effort, the NASA Marshall Space Flight Center has conducted combustion, performance, and combustion stability analyses of several of the configurations. This paper summarizes the analyses of combustion and performance as a follow-up to a paper published in the 2008 JANNAF/LPS meeting. Combustion stability analyses are presented in a separate paper. The current paper includes test and analysis results of coaxial element injectors using liquid oxygen and liquid methane or gaseous methane propellants. Several thrust chamber configurations have been modeled, including thrust chambers with multi-element swirl coax element injectors tested at the NASA MSFC, and a uni-element chamber with shear and swirl coax injectors tested at The Pennsylvania State University. Configurations were modeled with two one-dimensional liquid rocket combustion analysis codes, the Rocket Combustor Interaction Design and Analysis (ROCCID), and the Coaxial Injector Combustion Model (CICM). Significant effort was applied to show how these codes can be used to model combustion and performance with oxygen/methane propellants a priori, and what anchoring or calibrating features need to be applied or developed in the future. This paper describes the test hardware configurations, presents the results of all the analyses, and compares the results from the two analytical methods

Hulka, J. R.↗

Coaxial Injectors for Liquid Oxygen/Methane (LOX/CH4) Technology Development

Since late 2005, NASA s Marshall Space Flight Center (MSFC) has been developing and demonstrating technology for liquid oxygen and methane (LOX/CH4) engine designs. Efforts were undertaken to help advance technology that might benefit NASA s Exploration Technology Development Program. The propellant combination has gained interest as a potential option for the ascent stage main propulsion system on the Altair lunar lander vehicle. The propellants are also attractive for eventual Mars missions in future development activities. MSFC s efforts focus on evaluating the performance potential of both liquid and gaseous methane for specific injector designs. Previous JANNAF papers reported the performance observed for LOX and methane with an impinging injector. More recent efforts have focused on testing coaxial injector designs. Hot-fire testing performed at MSFC with thrust levels close to 5000 lbf demonstrated high performance with coaxial injectors of different element densities and various fuel film cooling levels. Test data provided results on performance, chamber wall compatibility, and heat flux profiles for different injectors. A variety of igniters were also demonstrated, including a torch igniter and a microwave (or plasma) igniter.

Elam, Sandra↗

Modified Coaxial Probe Feeds for Layered Antennas

In a modified configuration of a coaxial probe feed for a layered printed-circuit antenna (e.g., a microstrip antenna), the outer conductor of the coaxial cable extends through the thickness of at least one dielectric layer and is connected to both the ground-plane conductor and a radiator-plane conductor. This modified configuration simplifies the incorporation of such radio-frequency integrated circuits as power dividers, filters, and low-noise amplifiers. It also simplifies the design and fabrication of stacked antennas with aperture feeds.

Fink, Patrick W.↗

Uncertainty Analysis of Coaxial Thermocouple Calorimeters Used in Arc Jets

Recent introduction of Coaxial Thermocouple type calorimeters into the NASA Ames arc jet facilities has inspired an analysis of 2D conduction effects internal to this type of calorimeter. The 1D finite slab inverse analysis (which is typically used to deduce the heat transfer to the calorimeter) relies on the assumption that lateral conduction (i.e., 2D effects) is negligible. Most calorimeter bodies have a spherical nose, which in itself is a violation of the 1D finite slab analysis assumption. Secondly most calorimeters experience a variation in heating across the face of the body which is also a violation of the 1D finite slab analysis assumption. It turns out that these two effects tend to cancel each other to some extent. This paper shows the extent to which error exists in the analysis of the Coaxial Thermocouple type calorimeters, and also offers analysis strategies for reducing the errors.

Lateral Conduction↗

Impact of Nozzle Condition on Powder Catchment Efficiency for Coaxial Powder Direct Energy Deposition

Blown powder directed energy deposition is well-designed for fine resolution additive manufacturing processing. Coaxial powder deposition heads use an outer layer of shielding gas directed by an outer nozzle to prevent oxidation occurring during the powder melting process. Powder blown feedstock catchment efficiency can be as low as 50-80% whereas wire deposition systems are closer to 98% efficient. The present study evaluates the impact of directed energy deposition nozzle condition on catchment efficiency. Changes in the overall outer shielding gas nozzle length has been found to increase material usage efficiency by 10% through convergence of the powder flow. The results of this experiment show that for coaxial powder deposition head design, if the standoff distance can safely be decreased, powder catchment efficiency can be increased as the outer shielding gas nozzle is increased in length, or the standoff distance is decreased.

Heinrich, Lauren↗

Impact of Nozzle Condition on Powder Catchment Efficiency for Coaxial Powder Direct Energy Deposition

Blown powder directed energy deposition is well-designed for fine resolution additive manufacturing processing. Coaxial powder deposition heads use an outer layer of shielding gas directed by an outer nozzle to prevent oxidation occurring during the powder melting process. Powder blown feedstock catchment efficiency can be as low as 50-80% whereas wire deposition systems are closer to 98% efficient. The present study evaluates the impact of directed energy deposition nozzle condition on catchment efficiency. Changes in the overall outer shielding gas nozzle length has been found to increase material usage efficiency by 10% through convergence of the powder flow. The results of this experiment show that for coaxial powder deposition head design, if the standoff distance can safely be decreased, powder catchment efficiency can be increased as the outer shielding gas nozzle is increased in length, or the standoff distance is decreased.

Heinrich, Lauren↗

PyOECP: A flexible open-source software library for estimating and modeling the complex permittivity based on the open-ended coaxial probe (OECP) technique

Here, we present PyOECP, a Python-based flexible open-source software for estimating and modeling the complex permittivity obtained from the open-ended coaxial probe (OECP) technique. The transformation of the measured reflection coefficient to complex permittivity is performed based on three different methods. The software library contains the dielectric spectra of common reference liquids, which can be used to transform the reflection coefficient into the dielectric spectra. Several Python routines that are commonly employed (e.g., SciPy and NumPy) in the field of science and engineering are required only so that the users can alter the software structure depending on their needs. The modeling algorithm exploits the Markov Chain Monte Carlo method for the data regression. The discrete relaxation models can be built by a proper combination of well-known relaxation models. In addition to these models, electrode polarization, a typical measurement artifact for interpreting dielectric spectra, can be incorporated into the modeling algorithm. A continuous relaxation model, which solves the Fredholm integral equation of the first kind (a mathematically ill-posed problem), is also included. This open-source software enables users to freely adjust the physical parameters to obtain physical insight into their materials under test and will be consistently updated for more accurate measurement and interpretation of dielectric spectra in an automated manner. This work describes the theoretical and mathematical background of the software, lays out the workflow, and validates the software functionality based on both synthetic and empirical data included in the software.

97 MATHEMATICS AND COMPUTING↗

A metal-ceramic coaxial cable with multipoint Fabry-Pérot interferometers for monitoring distributed high temperature

A metal ceramic coaxial cable (MCCC) sensor containing multiple Fabry-Pérot interferometers (FPIs) has been designed, fabricated, and evaluated for measuring distributed high temperatures. The MCCC sensor demonstrated here consists of stainless steel tube and wire conductors, alumina tube insulator, and three pairs of air gap reflectors distributed along the cable. The multipoint sensor operation is realized by the joint time-frequency domain technique, which combines the functions of time-domain reflectometry and frequency division multiplexing to enable the measurement of spatially distributed temperature. The 3-point MCCC-FPI sensor has been demonstrated for distributed temperature measurements between 250 and 550 °C and operability up to 1000 °C. The sensor offers high sensitivity of >0.18 MHz/°C with a measurement resolution of 1 Hz and reasonably small high temperature measurement error range of ±3 °C.

42 ENGINEERING↗