Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “circuit breakers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Optimized Highly Efficient SSCB Using Organic Substrate Packaging for Electric Vehicle Applications

Solid State Circuit Breakers (SSCBs) are an attractive protection solution for their arcless current interruption and fast actuation speeds over mechanical breakers. This paper proposes a Bidirectional SSCB (BSSCB) with a thermally defined and digitally controlled current time profile for fault protection in EV and other low-voltage DC systems. The paper proposes an organic packaging approach utilizing flex circuitry to develop a reliable, cost-effective power module for BSSCBs. The paper studies transient heat transfer in the power modules using finite element analysis (FEA). An RC themal ladder network is extracted to define a fusing curve. To demonstrate and verify the design, a 1kV/50 A SiC MOSFET BSSCB prototype is fabricated and tested, having a power density of 60 W/cm3 and 4x reduction in form factor over presently researched breakers. Also, given are results for 750 V/150 A operation showing interruption in 2.4 μs.

organic power packaging↗

Calculating the Starting Currents of Electric Motors in 0.4 kV Auxiliary Networks of Nuclear Power Plants

Consideration is given to the effect of the resistance of the cable supplying power to the electric motor in the 0.4 kV auxiliary network of a nuclear (thermal) power plant on the starting current and, hence, on the current setpoint for the circuit breaker, on its sensitivity to short-circuit current, and on the cable size. It is shown that accounting for the resistance of the power cable of the motor that is commensurable with the starting resistance of the latter allows using a cable of smaller size compared with that determined regardless of its resistance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study of feasibility of solid-state electric switch gear for aircraft and spacecraft

The design of a solid-state circuit breaker that can be interconnected to a second breaker to form a transfer switch is presented. The breaker operates on a nominal 270-V dc circuit and controls power to loads of up to 15 A. Automatic overload trip is provided as a function of excess energy measured through the breaker and/or excess current through the breaker. After an overload trip, up to nine preprogrammable attempts to reclose may be tried with programmable delays between each attempt. The breaker or switch is remotely controllable. Test data on performance in the laboratory over temperatures from -45 to 100 C are provided. The feasibility of solid-state switch gear has been established.

Buchanan, E.↗

Federal Market Information Technology in the Post Flash Crash Era: Roles for Supercomputing

This paper describes collaborative work between active traders, regulators, economists, and supercomputing researchers to replicate and extend investigations of the Flash Crash and other market anomalies in a National Laboratory HPC environment. Our work suggests that supercomputing tools and methods will be valuable to market regulators in achieving the goal of market safety, stability, and security. Research results using high frequency data and analytics are described, and directions for future development are discussed. Currently the key mechanism for preventing catastrophic market action are “circuit breakers.” We believe a more graduated approach, similar to the “yellow light” approach in motorsports to slow down traffic, might be a better way to achieve the same goal. To enable this objective, we study a number of indicators that could foresee hazards in market conditions and explore options to confirm such predictions. Our tests confirm that Volume Synchronized Probability of Informed Trading (VPIN) and a version of volume Herfindahl-Hirschman Index (HHI) for measuring market fragmentation can indeed give strong signals ahead of the Flash Crash event on May 6 2010. This is a preliminary step toward a full-fledged early-warning system for unusual market conditions.

97 MATHEMATICS AND COMPUTING↗

Overview spectra and axial distribution of spectral line intensities in a high-current vacuum arc with CuCr electrodes

Spectroscopic investigations of free-burning vacuum arcs in diffuse mode with CuCr electrodes are presented. The experimental conditions of the investigated arc correspond to the typical system for vacuum circuit breakers. Spectra of six species Cu I, Cu II, Cu III, Cr I, Cr II, and Cr III have been analyzed in the wavelength range 350–810 nm. The axial intensity distributions were found to be strongly dependent on the ionization stage of radiating species. Emission distributions of Cr II and Cu II can be distinguished as well as the distributions of Cr III and Cu III. Information on the axial distribution was used to identify the spectra and for identification of overlapping spectral lines. The overview spectra and some spectral windows recorded with high resolution are presented. Analysis of axial distributions of emitted light, which originates from different ionization states, is presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Autonomous Restoration of Networked Microgrids Using Communication-Free Smart Sensing and Protection Units

Here this paper presents autonomous restoration of networked microgrids using distributed energy resources (DERs), inverter-based resources (IBRs) in general, and controllable assets of intelligence without communication to achieve a extremely resilient power system restoration. The main innovation of this work lies in use of real-time smart sensing and decision making that enable autonomous recombination of islanded microgrids, which are individually black-started by local grid-forming (GFM) inverter units. The smart circuit breakers (SCBs) designed and demonstrated here play critical roles in the restoration process to achieve autonomy; the autonomous restoration scheme is not pre-engineered and may be subject to encounter overloading, live or downed segments as the boundary of the microgrids dynamically expands without prior knowledge and only with local measurement. We demonstrate autonomous microgrid restoration both in simulation of a modified IEEE 13-bus system, and in a hardware testbed comprising 24 GFM-IBRs and 6-SCBs, depicting several scenarios to evaluate their functionalities and interoperability. This work validates high potential of extremely resilient microgrid using novel approaches for inverter-based bottom-up system restoration in a communication-free paradigm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Two-temperature transport coefficients of SF{sub 6}–N{sub 2} plasma

Sulfur hexafluoride (SF{sub 6}) is widely adopted in electric power industry, especially in high-voltage circuit breakers and gas-insulated switchgear. However, the use of SF{sub 6} is limited by its high liquidation temperature and high global warming potential. Recently, research shows SF{sub 6}–N{sub 2} mixture, which shows environmental friendliness and good electrical properties, may be a feasible substitute for pure SF{sub 6}. This paper is devoted to the calculation of and transport coefficients of SF{sub 6}–N{sub 2} mixture under both LTE (local thermodynamic equilibrium) and non-LTE condition. The two–temperature mass action law was used to determine the composition. The transport coefficients were calculated by classical Chapman–Enskog method simplified by Devoto. The thermophysical properties are presented for electron temperatures of 300–40 000 K, ratios of electron to heavy species temperature of 1–10 and N{sub 2} mole fraction of 0%–100% at atmospheric pressure. The ionization processes under both LTE and non-LTE have been discussed. The results show that deviations from local thermodynamic equilibrium significantly affect the properties of SF{sub 6}–N{sub 2} plasma, especially before the plasma is fully ionized. The different influence of N{sub 2} on properties for SF{sub 6}–N{sub 2} plasma in and out of LTE has been found. The results will serve as reliable reference data for computational simulation of the behavior of SF{sub 6}–N{sub 2} plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-Fast Resonant DC Breaker

This project’s focus was to create an ultra-fast resonant hybrid dc circuit breaker for medium voltage electric systems. Medium voltage DC systems offer higher efficiency, additional resiliency, more controllability, and greater flexibility over comparable AC systems. Although technically, medium voltage DC systems are more attractive than their AC counterparts, no solution exists for the protection of medium voltage DC systems, and thus one cannot build a reliable MVDC system. This research will fill the technology gap, providing a MVDC protection solution, allowing mass adoption and proliferation of MVDC systems. MVDC systems will allow greater integration of renewable energy sources, higher efficiency of transmission and distribution, reduced losses in transmission lines, reduce carbon emissions, and higher electric power reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligent, grid-friendly, modular extreme fast charging system with solid-state DC protection

The development of electric vehicle (EV) charging infrastructure is crucial for the widespread adoption of electric transportation. However, implementing such infrastructure is a complex task that requires consideration of factors such as space limitations, adherence to industry standards, grid capacity, and other technical and policy issues. This project seeks to create a framework for the efficient design of compact medium voltage (MV) extreme fast charging (XFC) stations for EVs. The station design involves the use of a solid-state transformer (SST) that connects to the MV distribution network, delivering power to a shared DC bus. This innovative approach eliminates the need for a step-down transformer to provide low-voltage service by connecting directly to the MV distribution network. Eliminating the low-frequency transformer not only reduces the system footprint and losses but also eliminates inrush currents during grid black-start. Additionally, placing power electronics directly on the distribution system allows for high-bandwidth filtering and power factor correction. The inclusion of a shared DC bus enables multiple charging dispensers and DC storage/generation units to connect, forming a DC microgrid. This setup facilitates power sharing with minimal conversion stages. The project showcases a DC distribution network protected by intelligent solid-state (SS) DC circuit breakers (DCCB) capable of isolating the smallest section of the faulted circuit much faster than existing mechanical solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltages and currents induced by lightning

Indirect effects of lightning, the damage to or malfunction of electrical equipment that results from lightning flashes, were considered. These effects range from tripped circuit breakers to computer upset, to physical damage to input or output circuits of electronic equipment. Voltages and currents induced by lightning on the electrical wiring of the aircraft were emphasized regardless of whether or not such voltages and currents cause damage or upset of electrical equipment.

Franklin A Fisher↗

Short-Circuit Characterization and Protection of 10-kV SiC mosfet

This paper presents the characterization of the temperature-dependent short-circuit performance of a Gen3 10 kV/20 A silicon carbide (SiC) mosfet. The test platform consisting of a phase-leg configuration and a fast speed 10-kV solid state circuit breaker, with temperature control, is introduced in detail. A novel FPGA-based short-circuit protection circuit having a response time of 1.5 μs is proposed and integrated into the gate driver. The short-circuit protection is validated through the platform. The short-circuit characteristics for both the hard switching fault and fault under load (FUL) types at various dc-link voltages (from 500 V to 6 kV) are tested and discussed. The saturation current increases with dc-link voltage and achieves 360 A at 6 kV. Different from low voltage SiC devices, there is no current spike in FUL type of fault. The temperature-dependent short-circuit performance is also presented from 25 to 125 °C. The difference of short-circuit waveforms at various initial junction temperatures can be neglected. Here, a thermal model of the 10-kV SiC mosfet is built for the junction temperature estimation during the short circuit and for analysis of the initial junction temperature impact on the short-circuit performance.

10-kV SiC mosfet↗

Designing a 25-kilowatt high frequency series resonant

The feasibility of processing 25 kW of power with a single, transistorized, 20 kHz, series resonant converter stage has been demonstrated by the successful design, development, fabrication, and testing of such a device. It employs four Westinghouse D7ST transistors in a full-bridge configuration and operates from a 250-to-350-Vdc input bus. The unit has an overall worst-case efficiency of 93.5% at its full rated output of 1000 V and 25 A dc. A solid-state dc input circuit breaker and output-transient-current limiters are included in and integrated into the design. Circuit details of the converter are presented along with test data.

Robson, R. R.↗

The 25 kW resonant dc/dc power converter

The feasibility of processing 25-kW of power with a single, transistorized, series resonant converter stage was demonstrated by the successful design, development, fabrication, and testing of such a device which employs four Westinghouse D7ST transistors in a full-bridge configuration and operates from a 250-to-350 Vdc input bus. The unit has an overall worst-case efficiency of 93.5% at its full rated output of 1000 V and 25 A dc. A solid-state dc input circuit breaker and output-transient-current limiters are included in and integrated into the design. Full circuit details of the converter are presented along with the test data.

Robson, R. R.↗

Adaptive Threshold-Based Zonal Isolation of Faults in a Multiterminal DC Using Local Measurements

Fast and accurate methods of fault detection and isolation are a pre-emptive measure in multiterminal dc (MTdc) systems. Zonal isolation of faults is necessary to prevent any misopertation of the dc breakers that can lead to a shutdown of the network. Existing techniques require fast-communication or data synchronization methods have their own disadvantages. This article proposes a method for efficient fault zone isolation without the need of a communication link that prevents any misoperation of the dc breakers in a radial MTdc. This method provides individual local measurement-based control to the hybrid dc circuit breakers (dcCB). Faults created outside the zone of protection for a breaker create a change in the rate of change of current or voltage leading to misoperation. To avoid detection using a fixed threshold, an adaptive threshold based approach is suggested that updates the threshold based on the present operating status. Sensitivity analysis by varying the current limiting inductance and fault location is performed. In conclusion, a three terminal radial model of an MTdc is used for zonal isolation using power system computer aided design/electromagnetic transients including dc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV Inverter Failures Cause AC Breaker Damage - Power Quality

This poster discusses how PV inverter failures cause AC breaker damage and is intended to help system owners identify power quality issues and origins, help inverter and/or circuit breaker manufacturers develop safer failure modes, and develop addendums to standards for failure testing of breakers and inverters.

arc↗

It's a Go

The Electrical Power Distribution Control Team takes on the task of determining power failures throughout the Orbiter. The Displays and Controls Team takes on the task of determining distribution, circuit breakers, and switch failures that might occur on the Orbiter or displays that stop working. This paper will identify the circuit packages I have put together for the D&C group, the redesigning of a Hybrid Driver Controller box, and the web designing the Displays and Controls website for easier access to information which can range from indicators to switches.

Welker, Joshua T.↗

Characterizing electrical panel capacity, breaker space, and loads in U.S. single-family homes

Electrical panels distribute electricity to appliances, equipment, and other building loads and maintain safety by preventing overloads of branch circuits, feeders, and utility service wires connecting homes to the grid. Load calculations in the National Electrical Code (NEC) determine the capacity of installed electrical panels in the United States, which are rated in amps (A). Circuit breakers within electrical panels affect the magnitude and number of loads that panels can serve. In home retrofits and renovations, existing electrical panels may not accommodate new electrical loads, either due to insufficient electrical capacity or a lack of available breaker spaces. Homes with these panel constraints may need to replace existing panels with new panels that have greater capacity and breaker space.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Current-limiting voltage regulator

Voltage regulator, which operates within preset current limits, acts as a circuit breaker to prevent overload failure, and automatically resets when the overload is removed. The power dissipated in the series transistor of the circuit is constant from normal load to short circuit condition.

Cleveland, E. F.↗