Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “chemical compounds”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Immobilized phosphorylase for synthesis of polysaccharides from glucose

Continuous processes for enzymatic production of carbohydrates from glucose are discussed. Key reactant in process is identified as phosphorylase which catalyzes reversible formation or degradation of polysaccharide. Chemical compounds and reactions to synthesize polysaccharides are analyzed.

Marshall, D. L.↗

New materials for manned spacecraft, aircraft, and other applications

The application of fire resistant spacecraft materials to the interior design of commercial aircraft is discussed. The use of such materials for curtains, upholstery, carpets, decorative panels, cabinets, paper products, and oxygen lines is examined. It is concluded that the highest degree of nonflammability can be obtained with inorganic fibers such as asbestos and fiber glass. The application of various chemical compounds for specific purposes is presented.

Radnofsky, M. I.↗

In situ transfer standard for ultrahigh vacuum gage calibration

A compact insitu calibration assembly, for ultrahigh vacuum gauges is described. The system depends on the repeatable generation of a specific gas pressure by the dissociation of a solid solution chemical compound when subjected to a given temperature. A precise temperature measurement is related to the pressure generated within the vacuum by the properties of the solid solution compound. this accurately establishes the gas pressure which in turn is used to calibrate a vacuum gauge. Also included is a metering orifice used in the calibration system and which is made movable to facilitate the degassing bakeout required in ultrahigh vacuum devices.

Outlaw, R. A.↗

Studies in neuroendocrine pharmacology

The expertise and facilities available within the Medical Sciences Program section on Pharmacology were used along with informational input from various NASA sources to study areas relevant to the manned space effort. Topics discussed include effects of drugs on deprivation-induced fluid consumption, brain biogenic amines, biochemical responses to stressful stimuli, biochemical and behavioral pharmacology of amphetamines, biochemical and pharmacological studies of analogues to biologically active indole compounds, chemical pharmacology: drug metabolism and disposition, toxicology, and chemical methodology. Appendices include a bibliography, and papers submitted for publication or already published.

Maickel, R. P.↗

Low toxic corrosion inhibitors for aluminum in fresh water

Combinations of chemical compounds that reportedly reduce the corrosion of aluminum in fresh water were evaluated. These included combinations of borates, nitrates, nitrites, phosphates, silicates, and mercaptobenzothiazole. Eight of fifty inhibitor combinations evaluated gave excellent corrosion protection and compared favorably with sodium chromate, which has generally been considered standard for many years.

Humphries, T. S.↗

Viking gas chromatograph-mass spectrometer

The Mars Viking gas chromatograph-mass spectrometer is described. The system is designed to determine the composition of the Martian atmosphere and detect and identify chemical compounds vaporized or pyrolyzed from the Martian soil. Construction details, performance data, data processing methods, and references to manufacturing and test procedures are also provided.

Rushneck, D. R.↗

Satellite observations of upper atmosphere O3 and HNO3 from the Limb Infrared Monitor of the Stratosphere /LIMS/ experiment on Nimbus 7

The Limb Infrared Monitor of the Stratosphere (LIMS) experiment, launched on-board the Nimbus satellite, was designed to measure both day and night limb radiance which is used to infer upper atmosphere temperature profiles and chemical compound concentrations important in the study of ozone chemistry. The LIMS instrument is a six channel, limb scanning, thermal radiometer which uses HgCdTe detectors, cooled to approximately 64 K. Measurements include ozone, water vapor, nitrogen dioxide, and nitric acid. The ozone and nitric acid channels are centered at approximately 9.6 microns and 11.3 microns, respectively. Results from the channels are described with an emphasis on data validation. The O3 and HNO3 channels have demonstrated high measurement precision.

Russell, J. M., III↗

The validation of LIMS ozone profiles using correlative rocket, ECC, and Dobson data sets

The Limb Infrared Monitor of the Stratosphere (LIMS) experiment is a limb scanning infrared sounder designed to measure vertical temperature profiles and the concentrations of key chemical compounds which are important in the stratospheric ozone-nitrogen photochemistry. Preliminary ozone profiles are being intercompared with correlative rocket and balloonsonde ozone data sets as part of the Nimbus 7 LIMS data validation activity. The LIMS ozone retrievals extend from the lower mesosphere to the tropopause (or cloud-top altitudes). In this paper, preliminary statistics of comparisons of ECC (electrochemical concentration cell) ozonesonde and rocket ozone profiles with LIMS ozone profiles are presented. ECC ozonesonde data taken at times of LIMS overpasses are also used to extend the LIMS retrieval down to ground level. Each combined profile is then integrated to obtain total column ozone. These integrated results are compared to Dobson data obtained at approximately the same time and location.

Remsberg, E. E.↗

Micro-Raman spectroscopy: The analysis of micrometer and submicrometer atmospheric aerosols

A nondestructive method of molecular analysis which is required to fully utilize the information contained within a collected particle is discussed. Upper atmosphere reaction mechanisms are assessed when the chemical compounds, the use of micro-Raman spectrometric techniques to perform micron and submicron particle analysis was evaluated. The results are favorable and it is concluded that micron and submicron particles can be analyzed by the micron-Raman approach. Completely automatic analysis should be possible to 0.3 micro m. No problems are anticipated with photo or thermal decomposition. Sample and impurity fluorescence are the key source of background as they cannot be completely eliminated.

Klainer, S. M.↗

Dry-Enzyme Test For Gaseous Chemicals

Simple, dry-chemical test detects ethanol in human breath. Method of test also adapted to detection of such toxic chemicals as formaldehyde in airstreams. Used qualitatively to detect chemical compounds above present level; for example, ethanol above legal level for driving. Also used to indicate quantitatively concentrations of compounds. Involves dry enzyme and color indicator. Adapted to detect any gaseous compound transformed by enzymes to produce change evident to human eye or to instrument.

Barzana, Eduardo↗

Low energy gamma ray attenuation in multiphase water

A gauging system is proposed to enable monitoring of slush density, solid-liquid interface, and slush level as well as its flow rate. It is based on the principle that the electromagnetic radiation mass attenuation coefficient of a multiphase chemical compound is constant for all relative phase concentrations. Results showing the essential constancy of mass attenuation coefficients for single-phase water vapor, liquid water, ice, and multiphase mixtures of water/ice are described.

Singh, Jag J.↗

Water/rock interactions in experimentally simulated dirty snowball and dirty iceball cometary nuclei

In the dirty snowball model for cometary nuclei, comet-nucleus materials are regarded as mixtures of volatile ices and relatively non-volatile minerals or chemical compounds. Carbonaceous chondrite meteorites are regarded as useful analogs for the rocky component. To help elucidate the possible physical geochemistry of cometary nuclei, preliminary results are reported of calorimetric experiments with two-component systems involving carbonaceous chondrites and water ice. Based on collective knowledge of the physics of water ice, three general types of interactions can be expected between water and minerals at sub-freezing temperatures: (1) heterogeneous nucleation of ice by insoluble minerals; (2) adsorption of water vapor by hygroscopic phases; and (3) freezing- and melting-point depression of liquid water sustained by soluble minerals. The relative and absolute magnitude of all three effects are expected to vary with mineral composition.

Gooding, James L.↗

Failure analysis of the lithium battery: A study of the header deposit on the cell top and diffusion within the electrode glass seal using nuclear microanalysis and FFTIR spectroscopy

The Solid Rocket Booster Range Safety System (SRBRSS) uses a lithium/poly-carbon monofluoride primary battery as a source of electrical power. After cell fabrication and activation, some battery cells have shown self discharge. One possible source of this cell discharge has been suggested to be the formation and growth of a conducting crystallized chemical compound across the glass bead insulator, electrically shorting the glass bead to the casing. This laboratory has begun an analysis of this compound, the glass seal holding the cathode into place, and the cell electrolyte, using Fast Fourier Transform Infrared (FFTIR) Analysis, Rutherford Backscattering Spectroscopy (RBS), and Nuclear Reaction Microanalysis. Preliminary measurements have confirmed the existence of lithium, nitrogen, fluorine, and oxygen on a reddish-brown deposit covering parts of the glass seal holding the positive electrode in place. Cells using Li metal electrodes, have many advantages over conventional primary batteries. One principal disadvantage of using Li batteries on a commercial basis would be the environmental impact of the fluorocarbon material. Another would be the relatively high expense of (CF)n.

Hassan, Razi A.↗

Feasibility study of a low-energy gamma ray system for measuring quantity and flow rate of slush hydrogen

As part of a study to demonstrate the suitability of an X-ray or gamma ray probe for monitoring the quality and flow rate of slush hydrogen, mass attenuation coefficients for Cd-109 X- and gamma radiation in five chemical compounds were measured. The Ag-109 K rays were used for water and acetic acid, whereas E3 transition from the first excited state at 87.7 keV in Ag-109 provided the probe radiation for bromobenzene, alpha (exp 2) chloroisodurene, and cetyl bromide. Measurements were made for a single phase (gas, liquid, solid) as well as mixed phases (liquid plus solid) in all cases. It was shown that the mass attenuation coefficient for the selected radiations is independent of the phase of the test fluids or phase ratios in the case of mixed phase fluids. Described here are the procedure and the results for the five fluid systems investigated.

Singh, Jag J.↗

Zeolite crystal growth in space

The growth of large, uniform zeolite crystals in high yield in space can have a major impact on the chemical process industry. Large zeolite crystals will be used to improve basic understanding of adsorption and catalytic mechanisms, and to make zeolite membranes. To grow large zeolites in microgravity, it is necessary to control the nucleation event and fluid motion, and to enhance nutrient transfer. Data is presented that suggests nucleation can be controlled using chemical compounds (e.g., Triethanolamine, for zeolite A), while not adversely effecting growth rate. A three-zone furnace has been designed to perform multiple syntheses concurrently. The operating range of the furnace is 295 K to 473 K. Teflon-lined autoclaves (10 ml liquid volume) have been designed to minimize contamination, reduce wall nucleation, and control mixing of pre-gel solutions on orbit. Zeolite synthesis experiments will be performed on USML-1 in 1992.

Sacco, Albert, Jr.↗

Adding intelligent services to an object oriented system

As today's software becomes increasingly complex, the need grows for intelligence of one sort or another to becomes part of the application, often an intelligence that does not readily fit the paradigm of one's software development. There are many methods of developing software, but at this time, the most promising is the object oriented (OO) method. This method involves an analysis to abstract the problem into separate 'objects' that are unique in the data that describe them and the behavior that they exhibit, and eventually to convert this analysis into computer code using a programming language that was designed (or retrofitted) for OO implementation. This paper discusses the creation of three different applications that are analyzed, designed, and programmed using the Shlaer/Mellor method of OO development and C++ as the programming language. All three, however, require the use of an expert system to provide an intelligence that C++ (or any other 'traditional' language) is not directly suited to supply. The flexibility of CLIPS permitted us to make modifications to it that allow seamless integration with any of our applications that require an expert system. We illustrate this integration with the following applications: (1) an after action review (AAR) station that assists a reviewer in watching a simulated tank battle and developing an AAR to critique the performance of the participants in the battle; (2) an embedded training system and over-the-shoulder coach for howitzer crewmen; and (3) a system to identify various chemical compounds from their infrared absorption spectra.

Robideaux, Bret R.↗

A digital boxcar integrator for IMS spectra

When trying to detect or quantify a signal at or near the limit of detectability, it is invariably embeded in the noise. This statement is true for nearly all detectors of any physical phenomena and the limit of detectability, hopefully, occurs at very low signal-to-noise levels. This is particularly true of IMS (Ion Mobility Spectrometers) spectra due to the low vapor pressure of several chemical compounds of great interest and the small currents associated with the ionic detection process. Gated Integrators and Boxcar Integrators or Averagers are designed to recover fast, repetitive analog signals. In a typical application, a time 'Gate' or 'Window' is generated, characterized by a set delay from a trigger or gate pulse and a certain width. A Gated Integrator amplifies and integrates the signal that is present during the time the gate is open, ignoring noise and interference that may be present at other times. Boxcar Integration refers to the practice of averaging the output of the Gated Integrator over many sweeps of the detector. Since any signal present during the gate will add linearly, while noise will add in a 'random walk' fashion as the square root of the number of sweeps, averaging N sweeps will improve the 'Signal-to-Noise Ratio' by a factor of the square root of N.

Cohen, Martin J.↗

The in situ exobiological investigation of the Martian surface mineralogy during unmanned missions

An important goal of exobiological research is to determine if life arose on planets other than Earth. The only other planet known, to date, on which life may have arisen is Mars. The data suggest that the physical environment of early Mars (i.e., temperature, pressure, and radiation regimes) was suitable for life to arise. Thus far, the data also suggest that early Mars possessed sufficient quantities of the required building blocks and a number of the chemical compounds necessary for life to arise. It is not known, however, if water existed in the appropriate state (i.e., liquid) in sufficient quantities long enough for life to arise. Determining the mineralogy and components of the Martian soil through in situ analyses during missions to Mars will provide information from which an assessment can be made for the probability of the origin of life on Mars. Missions to Mars in the near future will be unmanned and capable of in situ analyses. Our studies have shown that differential thermal analysis coupled with gas chromatography (DTA/GC) is a more appropriate analytical technique than, x-ray fluorescence, x-ray diffraction, alpha-proton backscatter, gamma-ray spectrometry, differential scanning calorimetry coupled with mass spectrometry (DSC/MS), or DSC/GC to identify the mineralogy of the Martian surface material in situ. DTA/GC is an advancement over the pyrolytic techniques flown on previous missions that have supplied only limited mineralogical information (Biemann et al. 1977).

Mancinelli, Rocco L.↗