Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105. This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of Cathode and Cavity Geometries in Electropolishing (EP): Electric Field Simulation

Niobium (Nb) superconducting radio frequency (SRF) cavities require electropolishing surface treatment to reach high acceleration gradient. EP performed in the plateau region of an I-V curve [1] leads to a smooth finish of the cavity surface including the equator surface. The equator surface is vital because a rough equator surface leads to premature quench and limit the cavity performance. Previous experimental work was performed to optimize EP parameters for low-beta (LB) 650 MHz Nb cavity [1]. It was found that different cathode surface areas vary the plateau onset voltage. A lower onset voltage was achieved for HB650 cavity with an enlarged cathode surface area. The aim of the study is to perform electrostatic and electrochemical simulation to understand the impact of both cavity geometry and cathodes. This report covers an initial result on electric field simulation performed with HB and LB 650 MHz cavities.

Loer, Bereket↗

Nb SRF cavities applied to searches for beyond the standard model physics

The SRF technology developed for accelerators can be successfully applied to new applications, including quantum computing, dark matter searches and beyond the standard model physics. The ultra-high quality factor of SRF cavities can al-low to achieve unprecedented sensitivity in fields outside of the usual accelerator applications, for examples fundamental and beyond the standard model physics. Applications of SRF cavities for gravitational waves searches are also being investigated. The SQMS Physics and Sensing thrust is working on this effort as it strives to combine SRF cavities with QIS, with a focus on BSM and fundamental physics. Using Nb SRF cavities, we run a proof of principle search for the dark photon dark matter candidate at fixed frequency demonstrating the deepest sensitivity to wavelike dark mater [1]. The Dark SRF experiment uses two 1.3GHz SRF cavities to conduct a light shining through wall (LSW) experiment to attempt producing and detecting dark photons in the laboratory. The results of this first superconducting LSW search were recently published [2] and we are now working on the second phase of the experiment, which will be run in a dilution refrigerator using 2.6GHz SRF cavities. In addition to the limits we have achieved, we will also present the experiments we are currently developing, such as the heterodyne axion DM search [3, 4], the SERAPH series of experiments, and gravitational waves searches based on SRF cavities as proposed in [5-8].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Prototype Superconducting Radio-Frequency Cavity for Conduction-Cooled Accelerators

Recent progress in the development of high-quality Nb?Sn film coatings along with the availability of cryocoolers with high cooling capacity at 4 K makes it feasible to operate SRF cavities cooled by thermal conduction at relevant accelerating gradients for use in accelerators. We have developed a prototype single-cell cavity to prove the feasibility of operation up to the accelerating gradient required for 1 MeV energy gain, cooled by conduction with cryocoolers. The cavity has a ~3 ¿m thick Nb?Sn film on the inner surface, deposited on a ~4 mm thick bulk Nb substrate and a bulk ~7 mm thick Cu outer shell with three Cu attachment tabs. The cavity was tested up to a peak surface magnetic field of 53 mT in liquid He at 4.3 K. A horizontal test cryostat was designed and built to test the cavity cooled with three cryocoolers. The rf tests of the conduction-cooled cavity achieved a peak surface magnetic field of 50 mT and stable operation was possible with up to 18.5 W of rf heat load. The peak frequency shift due to microphonics was 23 Hz. These results represent the highest peak surface magnetic field achieved in a conduction-cooled SRF cavity to date

Ciovati, Gianluigi↗

SRF Cavity Instability Detection with Machine Learning at CEBAF

During the operation of CEBAF, one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. Identifying an unstable cavity out of the hundreds of cavities installed at CEBAF is difficult and time-consuming. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detect fast transient instabilities. A fast data acquisition system for the legacy SRF cavities is being developed which samples and reports at 5 kHz to allow for detection of transients. A prototype chassis has been installed and tested in CEBAF. An autoencoder based machine learning model is being developed to identify anomalous SRF cavity behavior. The model is presently being trained on the slow (1 Hz) data that is currently available, and a separate model will be developed and trained using the fast (5 kHz) DAQ data once it becomes available. This paper will discuss the present status of the new fast data acquisition system and results of testing the prototype chassis. This paper will also detail the initial performance metrics of the autoencoder model.

Carpenter, A.↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

SRF Cavity Instability Detection with Machine Learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detect fast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. A Principal Component Analysis (PCA) approach is being developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and PCA model, along with initial performance metrics. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Carpenter, A.↗

A Mechanically Tuned Superconducting Main Injector Cavity

Radio Frequency (RF) superconductivity has been a mainstay of accelerator science for decades. However, its benefits have yet to be applied to proton synchrotrons with demanding tuning requirements. For example, the Main Injector (MI), Fermilab's high-energy proton synchrotron, currently utilizes 20+ ferrite-loaded cavities for a targeted 1.2 s acceleration cycle. Harnessing the extremely high gradients associated with superconductivity, the required number of cavities could be reduced by an order of magnitude, dramatically lowering operational power requirements even with cryogenic considerations. Additionally, the current plans for the Fermilab Accelerator Complex Evolution (ACE) initiative involve almost doubling the number of cavities in MI if the same designs are to be used, further highlighting the potential benefits of superconductivity. These advantages are attractive, but to date, no tunable superconducting cavity suitable for MI has been proposed due to the incompatibility of conventional broadband tuning methods with superconductivity. Here, we present a tunable superconducting cavity concept capable of record-breaking performance. Tuning will be accomplished by using high-speed linear actuators to vary the insertion depth of metallic plungers into the cavity volume. This tuning concept is theoretically viable with currently available technology and will be fully compatible with a superconducting cavity.

43 PARTICLE ACCELERATORS↗

Progress and Challenges in Traveling-Wave SRF cavity development at Fermilab

Traveling-wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the limit of 50~60MV/m in Standing-wave (SW) technology. The early stages of TW SRF cavity developments had been funded by several SBIR grants to Euclid Techlabs and completed in collaboration with Fermilab through a 1-cell prototype and a proof-of-principle 3-cell TW cavity. The TW resonance excitation in the 3-cell TW cavity at 2K was demonstrated through the low power RF test in early 2024. A high-power test of the 3-cell in TW mode being prepared. To advance a design and technology to fabricate a novel high gradient TW SRF cavity, FNAL proposed a half-meter TW RF design and R&Ds to realize that are in progress. Here we will report the recent progress in the 3-cell TW cavity and the challenges towards a half-meter scale TW cavity.

Furuta, F.↗

Development of Transformative Preparation Methods to Push up High Q&G Performance of FRIB Spare HWR Cryomodule Cavities

The FRIB accelerator project construction, a top priority of US nuclear science, was completed in January 2022, and is now moving to user operation. The stable and reliable operation of the accelerating cryomodules is essential in achieving/fulfilling DOE and user expectations. So far, FRIB cryomodules meet all FRIB specifications for cavity performance. However, during the lifetime of machine operation, degradation of cryomodule performance is possible, as reported in similar operating facilities (CEBAF, SNS). If cryomodule degradation is observed at FRIB, the under-performing cryomodule will require replacement/maintenance. In effort to manage operational reliability, FRIB plans to construct a 0.53 half-wave cryomodule to serve as an active spare. In a parallel effort, FRIB will also work toward increasing operational Q and gradient of spare cryomodule cavities to gain an overall performance margin to support future operational reliability. The current FRIB cavity designs have a potential to operate at gradients higher than 8 MV/m, but are currently limited by field emission (FE) and/or high field Q slope (HFQS); known issue in buffered chemical polished (BCP) treated cavities. The proposal looks to develop transformative surface preparation treatments to improve the operational gradient of spare cryomodules higher than 10 MV/m while maintaining high Q. Thus, increasing operational margin by 30 - 50%. With the goal to improve operational reliability set, the proposal will investigate multiple objectives as possible paths forward to achieve an overall increase in cavity performance and gain a better understanding of SRF limiting mechanisms. The proposal will study the application of different chemical surface treatments to 0.53 half-wave cavities, with the addition of low temperature bakes (LTB), and measure their effects on accelerating performance. Proposed chemical treatments to be explored in this proposal include conventional EP acid mixtures, as well as innovated EP and BCP acid mixtures designed to simplify processing paths in migrating FE and HFQS. The proposed transformative treatment wet N-doping also has the potential to replicate recent advancements in SRF technology relating to nitrogen doping and high Q operation without the requirement for an ultra-high vacuum annealing furnace; currently being developed at FNAL and JLAB. In parallel, high Q performance relating to flux trapping will be investigated with the installation of a second layer of magnetic shielding in the vertical test Dewar. The research objectives presented in the proposal, and their corresponding effects on cavity performance, will provide essential knowledge and future guidance to the SRF community and provide possible paths for future SRF based projects and applications.

43 PARTICLE ACCELERATORS↗

Advancements in High-Q development for novel medium-velocity 644 MHz 5-cell elliptical superconducting RF cavities for continuous-wave operation in heavy-ion linacs

The Facility for Rare Isotope Beams is a world-leading center for experimental nuclear physics research, and relies on a first-in-kind superconducting RF driver linac to supply 400 kW beams of a uniquely large range of particles, from protons through the heaviest uranium ions. The FRIB400 project proposes to double the end energy of the current superconducting FRIB linac for the heaviest uranium ions from 200 MeV per nucleon (MeV/u) to 400 MeV/u, which equates to approximately 1 GeV for protons. The increased rare isotope production from higher-energy drive beams would deliver new and exciting capabilities to FRIB users, which include extending the facility's reach along the neutron drip-line, greatly increasing the facility's rare isotope yield, and significantly improving the precision of parameter measurements for the nuclear matter equation of state, which is a particularly timely complement to the recent advent of multi-messenger astronomy, and the study of neutron star mergers. The unique set of design parameters defined by the 400 MeV/u (uranium) energy goal, the physical size, continuous-wave operation, and cryogenic capacity of the extant facilities at FRIB, requires development of a first-in-kind beta = v/c = 0.65, 644 MHz 5-cell elliptical superconducting RF (SRF) cavity, with field-leading efficiency, measured by the cavity's intrinsic quality factor, Q_0. The field of SRF has recently experienced a very active period of development, which demonstrated the potential to raise the Q_0 of 1.3 GHz cavities by factors of two to three or more. In addition to uncovering fascinating new properties of the fundamental physics of superconducting RF phenomena, these improvements suggest substantial improvements could be made over the minimum Q_0 of the proposed FRIB400 upgrade SRF cavities, if these new techniques can be adapted to the beta = 0.65, 644 MHz regime. This work presents the first validation of the the novel beta = 0.65, 644 MHz 5-cell elliptical superconducting RF cavity design, and the first results of both conventional and advanced RF surface preparation techniques. In particular, this work focuses on two recently-developed high-Q_0 recipes: N-doping, and furnace baking, setting the current world-record Q_0 for this type of resonant cavity at 3.8 x 10^10 at the FRIB400 operating gradient of 17.5 MV/m. We also find evidence that these results may be further improved upon, and make the case for further RF surface preparation recipe optimization. We then pair these high-power RF investigations with techniques borrowed from material science to try to better understand the ways in which specific properties of the niobium material, such as grain structure and superconducting flux pinning force, can be related to its superconducting RF performance. These experiments better elucidate the effects of high-temperature annealing on niobium samples, which suggest methods of further optimizing cavity flux expulsion and thus SRF performance.Read

McGee, Kellen E.↗

PI Loop Resonance Control for Dark Photon Experiment at 2 K Using a 2.6 GHz SRF Cavity

Two 2.6 GHz SRF cavities are being used for a dark photon search at the vertical test stand (VTS) in FNAL, for the second phase of the Dark SRF experiment. During testing at 2 K the cavities experience frequency detuning caused by microphonics and slow frequency drifts. The experiment requires that the two cavities have the same frequency within the cavity's bandwidth. These two cavities are equipped with frequency tuners consisting of three piezo actuators. The piezo actuators are used for fine-fast frequency tuning. A proportional-integral (PI) loop utilizing the three piezos on the emitter was used to stabilize the cavity frequency and match the receiver cavity frequency. The results from this implementation will be discussed. The integration time was also calculated via simulation.

43 PARTICLE ACCELERATORS↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105.This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress and Challenges in Traveling-Wave SRF cavity development at Fermilab

Traveling-wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the limit of 50~60MV/m in Standing-wave (SW) technology. The early stages of TW SRF cavity developments had been funded by several SBIR grants to Euclid Techlabs and completed in collaboration with Fermilab through a 1-cell prototype and a proof-of-principle 3-cell TW cavity. The TW resonance excitation in the 3-cell TW cavity at 2K was demonstrated through the low power RF test in early 2024. A high-power test of the 3-cell in TW mode being prepared. To advance a design and technology to fabricate a novel high gradient TW SRF cavity, FNAL proposed a half-meter TW RF design and R&Ds to realize that are in progress. Here we will report the recent progress in the 3-cell TW cavity and the challenges towards a half-meter scale TW cavity.

Furuta, F.↗

Excellent performance of 650 MHz single-cell niobium cavity after electropolishing

Electropolishing process and cathodes have undergone modification and optimization for both low- and high-beta 650 MHz five-cell niobium cavities for PIP-II. Cavities treated with these modified electropolishing conditions exhibited smooth surfaces and good performance in baseline tests. Nonetheless, due to administrative constraints on project cavities, maximum gradient performance testing was not conducted. This paper presents a study conducted on a single-cell 650 MHz cavity utilizing the optimized electropolishing conditions, highlighting the maximum performance attained for this specific cavity. The cavity tested at 2 K in a vertical cryostat reached a superior accelerating field gradient of 53.3 MV/m at Q0 of 1.6x1010, which is the highest gradient attained for this type of large-sized cavities.

43 PARTICLE ACCELERATORS↗

Nb3Sn Superconducting Radiofrequency Cavity Fabricated by Sputter Deposition from a Stoichiometric Target

Nb$_3$Sn is a promising coating material for superconducting radiofrequency cavities in next-generation accelerators due to its higher superconducting transition temperature (~18.3 K) and superheating field (~400 mT), offering the potential to surpass the intrinsic performance limits of bulk niobium. We developed a sputter coating technique employing a stoichiometric target to fabricate Nb$_3$Sn films on the inner surfaces of niobium cavities. A Nb$_3$Sn tube target, prepared by growing a >20 m thick Nb$_3$Sn coating on the surface of a Nb tube via a Sn vapor diffusion process, was used in a DC cylindrical magnetron sputtering system. Approximately 170 nm thick Nb-Sn films were sputter-coated onto flat Nb substrates positioned to replicate the beam tube and equator regions of a 2.6 GHz cavity, followed by annealing at 950 °C for 3 hours to form Nb$_3$Sn. The composition, morphology, and structure of the annealed Nb$_3$Sn films were examined. Then, a ~1.2 m-thick film was sputter-coated onto the interior of a 2.6 GHz Nb cavity following the procedure developed for the flat samples. The cavity was subsequently annealed under the same conditions used for the flat samples. Cryogenic RF testing of the sputter-coated cavity demonstrated a T$_c$ of approximately 17.8 K, consistent with Nb$_3$Sn layer. Subsequently, the cavity underwent a light Sn recoating followed by a vapor diffusion Nb$_3$Sn coating process, achieving a quality factor of approximately 8.5 × 10$^9$ and an accelerating gradient of up to 11.3 MV/m at 4.2 K.

Shakel, Md Sharifuzzaman [Old Dominion U.; Jeffers↗

Neural-Network Inverse Design of SRF Cavities and Transmons for Bosonic Quantum Computation

Three-dimensional superconducting radio-frequency (SRF) cavities provide exceptionally long-lived electromagnetic modes and, when coupled to nonlinear elements such as transmon qubits, become promising architectures for bosonic quantum information processing. The inverse design of such systems, i.e., recovering device geometries that produce specified electromagnetic and coupling targets, is generally a one-to-many problem. The qubit-cavity coupling strength depends sensitively on both the transmon geometry and its position within the cavity's electromagnetic field. As these systems scale up and their design parameter spaces grow, the cost of conventional iterative simulation becomes prohibitive. We present two deep neural network (DNN) approaches that address this inverse-design problem at complementary levels of the design stack. The first proposes SRF cavity geometries that produce target cavity observables. The second proposes transmon qubit designs that produce target qubit-cavity parameters - the coupling rate, qubit frequency, and anharmonicity $(g, ν_q, α)$. The recovered candidate designs match the targets to within ~5% (cavity) and ~2% (transmon), confirmed by end-to-end re-simulation. Both approaches map desired device behavior directly to candidate designs, a fast alternative to the iterative simulation studies usually required.

Yaker, Joseph [Fermilab; Northwestern U.]↗

Axion dark matter search with a photonic bandgap cavity haloscope and dielectric tuning rod over 10.25-10.45 GHz

We report the development of a new widely tunable cavity and demonstrate its use in a search for dark matter axions. We achieve unloaded quality factors above $10^{5}$, roughly $25\times$ larger than a bare copper cavity at the same frequency, using concentric sapphire shells to reduce Ohmic losses on the cavity barrel. A rotating sapphire rod tunes our cavity mode over the $10.1-11.7$ GHz range, approximately $16\%$ of its resonant frequency. Using an amplified receiver chain, we demonstrate sensitivity to new axion parameter space by tuning the cavity over the $200$ MHz range between $10.25-10.45$ GHz (42.4 - 43.2, $μ$eV) to constrain the axion-to-photon coupling to $|g_{aγγ}|$$\leq$ 1 $\times$$10^{-12}$${GeV}^{-1}$. This cavity can scan its tuning range about $9$ times faster compared to a bare copper cavity when paired with a photon counting device, laying the groundwork for a definitive search for the QCD axion over $10.1-11.7$ GHz.

Lynn, Morgan [Chicago U.]↗