Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capillary pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Compressed CO2 Hard Rock Drill for Mars

We have developed a down-the-hole (DTH) rotary-percussive drill prototype that could operate on compressed Mars atmospheric CO2 gas with a wireline drilling approach. This technology addresses a need for more aggressive sampling and drilling techniques, for both scientific purposes and to obtain In-Situ Resource Utilization (ISRU) resources for future NASA missions and human crew support. Using a spool of lightweight, high-pressure capillary, a DTH drill assembly would be moved in and out of the hole that could be a kilometer or more in depth. The CO2 drill is designed so that Mars atmospheric CO2 could be collected, compressed, and supplied down the hole and routed through microducts, valves, and reservoirs for the purpose of controlling miniature mechanical actuation in the assembly. By using compressed CO2, the drill system avoids the need for heavy electrical cabling and actuator systems or a liquid media for carrying away particulates as is typically used in terrestrial drilling systems. Instead, the liquid CO2 that powers the drill expands to a gas and could be channeled around the drill housing to carry cuttings to be collected in a bailing bucket. Where terrestrial systems often use drill depth vs time as a metric, a Mars drilling system would need to be extremely low mass, but would have no need to perform under tight schedules. In this paper, we will document our trade studies, progression for the design of microduct logic verified through multiple generations of prototypes, and provide predictive performance data on energy consumption, hole depth, and drill time.

Wilcox, Brian↗

Compressed CO2 Hard Rock Drill for Mars

We have developed a down-the-hole (DTH) rotary-percussive drill prototype that could operate on compressed Mars atmospheric CO2 gas with a wireline drilling approach. This technology addresses a need for more aggressive sampling and drilling techniques, for both scientific purposes and to obtain In-Situ Resource Utilization (ISRU) resources for future NASA missions and human crew support. Using a spool of lightweight, high-pressure capillary, a DTH drill assembly would be moved in and out of the hole that could be a kilometer or more in depth. The CO2 drill is designed so that Mars atmospheric CO2 could be collected, compressed, and supplied down the hole and routed through microducts, valves, and reservoirs for the purpose of controlling miniature mechanical actuation in the assembly. By using compressed CO2, the drill system avoids the need for heavy electrical cabling and actuator systems or a liquid media for carrying away particulates as is typically used in terrestrial drilling systems. Instead, the liquid CO2 that powers the drill expands to a gas and could be channeled around the drill housing to carry cuttings to be collected in a bailing bucket. Where terrestrial systems often use drill depth vs time as a metric, a Mars drilling system would need to be extremely low mass, but would have no need to perform under tight schedules. In this paper, we will document our trade studies, progression for the design of microduct logic verified through multiple generations of prototypes, and provide predictive performance data on energy consumption, hole depth, and drill time.

Wilcox, Brian↗

Impact of sub-core scale heterogeneity on CO2/brine multiphase flow for geological carbon storage in the Minnelusa sandstone

CO2 geological storage in deep saline aquifers is a mitigation option for CO2 emissions due to its large storage capacity and immediate accessibility. Accurately determining the CO2-brine relative permeability curves is key to the evaluation of CO2 injectivity and sweep efficiency in reservoir simulation as well as the CO2 injection in the field. This study highlights the remarkable effects of sub-core scale heterogeneity on the CO2-brine multiphase flow properties of the Minnelusa Sandstone in Wyoming. Two unsteady state CO2-brine drainage experiments were performed on the two samples. The first sample exhibits slanted laminated structure, while the second one represents a more homogeneous sandstone system. The CO2 saturation distributions during drainage reveals that the main variation in multiphase flow properties of two core samples were attributed to the porosity distribution that leads to the capillary pressure heterogeneity. Assisted history matching was used to obtain the respective relative permeability curves, which suggests heterogeneity-dependent behavior. In addition, sensitive and uncertainty analyses indicate that physical and petro-physical properties of low-porosity and low-permeability bedding layers exert marked effects on CO2 front breakthrough time and brine production. The results presented in this study help to gain insight into the CO2-brine multiphase flow properties in heterogeneous sandstones and can pave the way for the upscaling of CO2 migration and field-scale simulation accurately. This work is funded under the Department of Energy CarbonSAFE program (awards DE-FE0031624 DE0031891).

Kou, Zuhao↗

System and method for optimizing hydrocarbon production from subsurface reservoirs

A method is described for subsurface hydrocarbon reservoir characterization including receiving a time-lapse electromagnetic (EM) dataset and a flow dataset; inverting the time-lapse EM dataset using a parametric inversion that models steel well casings to determine a volume of fluid-changed reservoir; inverting the time-lapse EM dataset and the flow dataset using a joint inversion that honors the volume of the fluid-changed reservoir to determine relative permeability and capillary pressure; and characterizing flow characteristics in the volume of the fluid-changed reservoir. The method may be executed by a computer system.

Hoversten, Gary Michael↗

Micro-Textured Black Silicon Wick for Silicon Heat Pipe Array

Planar, semiconductor heat arrays have been previously proposed and developed; however, this design makes use of a novel, microscale black silicon wick structure that provides increased capillary pumping pressure of the internal working fluid, resulting in increased effective thermal conductivity of the device, and also enables operation of the device in any orientation with respect to the gravity vector. In a heat pipe, the efficiency of thermal transfer from the case to the working fluid is directly proportional to the surface area of the wick in contact with the fluid. Also, the primary failure mechanism for heat pipes operating within the temperature range of interest is inadequate capillary pressure for the return of fluid from the condenser to the wick. This is also what makes the operation of heat pipes orientation-sensitive. Thus, the two primary requirements for a good wick design are a large surface area and high capillary pressure. Surface area can be maximized through nanomachined surface roughening. Capillary pressure is largely driven by the working fluid and wick structure. The proposed nanostructure wick has characteristic dimensions on the order of tens of microns, which promotes menisci of very small radii. This results in the possibility of enormous pumping potential due to the inverse proportionality with radius. Wetting, which also enhances capillary pumping, can be maximized through growth of an oxide layer or material deposition (e.g. TiO2) to create a superhydrophilic surface.

Yee, Karl Y.↗

Deterioration of left ventricular chamber performance after bed rest : "cardiovascular deconditioning" or hypovolemia?

BACKGROUND: Orthostatic intolerance after bed rest is characterized by hypovolemia and an excessive reduction in stroke volume (SV) in the upright position. We studied whether the reduction in SV is due to a specific adaptation of the heart to head-down tilt bed rest (HDTBR) or acute hypovolemia alone. METHODS AND RESULTS: We constructed left ventricular (LV) pressure-volume curves from pulmonary capillary wedge pressure and LV end-diastolic volume and Starling curves from pulmonary capillary wedge pressure and SV during lower body negative pressure and saline loading in 7 men (25+/-2 years) before and after 2 weeks of -6 degrees HDTBR and after the acute administration of intravenous furosemide. Both HDTBR and hypovolemia led to a similar reduction in plasma volume. However, baseline LV end-diastolic volume decreased by 20+/-4% after HDTBR and by 7+/-2% after hypovolemia (interaction P<0.001). Moreover, SV was reduced more and the Starling curve was steeper during orthostatic stress after HDTBR than after hypovolemia. The pressure-volume curve showed a leftward shift and the equilibrium volume of the left ventricle was decreased after HDTBR; however, after hypovolemia alone, the curve was identical, with no change in equilibrium volume. Lower body negative pressure tolerance was reduced after both conditions; it decreased by 27+/-7% (P<0.05) after HDTBR and by 18+/-8% (P<0.05) after hypovolemia. CONCLUSIONS: Chronic HDTBR leads to ventricular remodeling, which is not seen with equivalent degrees of acute hypovolemia. This remodeling leads to a greater decrease in SV during orthostatic stress after bed rest than hypovolemia alone, potentially contributing to orthostatic intolerance.

NASA Discipline Cardiopulmonary↗

Capillary electrophoresis: Imaging of electroosmotic and pressure driven flow profiles in fused silica capillaries

This study is a continuation of the summer of 1994 NASA/ASEE Summer Faculty Fellowship Program. This effort is a portion of the ongoing work by the Biophysics Branch of the Marshall Space Flight Center. The work has focused recently on the separation of macromolecules using capillary electrophoresis (CE). Two primary goals were established for the effort this summer. First, we wanted to use capillary electrophoresis to study the electrohydrodynamics of a sample stream. Secondly, there was a need to develop a methodology for using CE for separation of DNA molecules of various sizes. In order to achieve these goals we needed to establish a procedure for detection of a sample plug under the influence of an electric field Detection of the sample with the microscope and image analysis system would be helpful in studying the electrohydrodynamics of this stream under load. Videotaping this process under the influence of an electric field in real time would also be useful. Imaging and photography of the sample/background electrolyte interface would be vital to this study. Finally, detection and imaging of electroosmotic flow and pressure driven flow must be accomplished.

Williams, George O., Jr.↗

An Experimental Study of Pressure Oscillation in a Capillary Pumped Loop with Multiple Evaporators and Condensers

The heat transport capability of a capillary pumped loop (CPL) is limited by the pressure drop that its evaporator wick can sustain. The pressure drop in a CPL is not constant even under seemingly steady operation, but rather exhibits an oscillatory behavior. A hydrodynamic theory based on a mass-spring-dashpot model was previously developed to predict the pressure oscillation in a CPL with a single evaporator and a single condenser. The theory states that the pressure oscillation is a function of physical dimensions of the CPL components and operating conditions. Experimental data agreed very well with theoretical predictions. The hydrodynamic stability theory has recently been extended to predict the pressure oscillations in CPLs with multiple evaporators and multiple condensers. Concurrently, an experimental study was conducted to verify the theory and to investigate the effects of various parameters on the pressure oscillation. Four evaporators with different wick properties were tested using a test loop containing two condenser plates. The test loop allowed the four evaporators to be tested in a single-pump, two-pump or four-pump configuration, and the two condenser plates to be plumbed either in parallel or in series. Test conditions included varying the power input, the reservoir set point temperature, the condenser sink temperature, and the flow resistance between the reservoir and the loop. Experimental results agreed well with theoretical predictions.

Ku, Jen-Tung↗

Enhanced Laplace Pressures for Functional Surfaces: Wicking, Switchability, and Selectivity

Abstract Wetting functionalities of rough surfaces are largely determined by the Laplace pressure generated across liquid–gas interfaces formed within surface structures. Typically, rough wetting surfaces create negative Laplace pressures, enabling capillary wicking, while rough non‐wetting surfaces create positive Laplace pressures, exhibiting fluid repellency. Here, with microfabricated reentrant structures, it is shown that the same surface can exhibit either a negative or positive Laplace pressure, regardless of its intrinsic wettability. This material‐independent Laplace pressure duality enables or enhances a range of wetting functionalities including wicking, switchability, and selectivity. On the same surface, capillary rise, capillary dip, and the combination of the two which leads to further enhancement of the total sustainable capillary height and Laplace pressure, the driving force for wicking is demonstrated. Further, active switching of wetting states between the hemiwicking and the repellent Cassie state on reentrant structures is shown. Moreover, with a water‐hexane mixture system, selective wetting of reentrant structures are demonstrated, that is, water can be selectively wicked or repelled in the presence of hexane, and vice versa. These functionalities are achieved, which would typically require complex chemical coatings, solely using surface structures, thus largely expanding the design space for a wide range of thermofluidic applications.

36 MATERIALS SCIENCE↗

Effects of alkali dosage and silicate modulus on autogenous shrinkage of alkali-activated slag cement paste

Autogenous shrinkage of alkali-activated slag cement (AASC) paste prepared with different levels of alkali dosage and silicate modulus (M{sub s}) is investigated. The results show that autogenous shrinkage of AASC paste increases at a decreasing rate with alkali dosage, which is attributed to enhanced capillary pore pressure and syneresis of C-A-S-H gels. Autogenous shrinkage of AASC paste with a constant alkali dosage increases as M{sub s} increases from 0.5 to 1.0, followed with a reduction as M{sub s} further increases to 2.0. Increasing M{sub s} initially enhances the capillary pore pressure due to the enhanced reaction degree, and promotes the formation of saturated capillary pores and viscoelasticity, which facilitates the autogenous shrinkage of AASC paste. However, excessive silicate in the activator retards the internal moisture consumption, and subsequently decreases the autogenous shrinkage of AASC paste. Furthermore, increasing M{sub s} can also intensify syneresis of C-A-S-H gels, contributing to the early-age autogenous shrinkage of AASC paste.

36 MATERIALS SCIENCE↗

Leakage From Coexisting Geologic Forcing and Injection‐Induced Pressurization: A Semi‐Analytical Solution for Multilayered Aquifers With Multiple Wells

Abstract Abnormal fluid pressures (above or below hydrostatic pressure) can develop and persist in sedimentary basins. The common occurrence of abnormal pressures may cause challenges for project permitting of geological carbon sequestration (GCS), particularly in reservoirs with pre‐injection overpressure. The leaky wells that may exist in some sedimentary basins can provide flow paths between deep brine aquifers and shallower freshwater aquifers. Pre‐injection relative overpressures can cause brine leakage through leaky wells even before any injection occurs. The tendency for flow through leaky wells is coupled with the process of pressure dissipation that occurs through aquitards. Specifically, with non‐zero permeability, aquitards can dissipate pressure over large areal extents and thereby reduce leakage rates through leaky wells. This study presents development of a semi‐analytical solution for hydraulic head and brine leakage in multilayered aquifer–aquitard systems with geologic pressure forcing. The geologic forcing that causes abnormal pressures in the multilayered system can coexist with any number of injection, extraction, and leaky wells that also affect fluid pressure. The semi‐analytical model is applied to explore how leakage through leaky wells varies as functions of pressurization rate, along with aquitard and leaky well properties in an overpressured multilayered system. The results show that although injection‐induced pressures can dissipate rapidly through suitably permeable aquitards, coexisting geologic forcing may create sustained rates of brine leakage into freshwater aquifers through leaky wells. In GCS, a very low‐permeability aquitard with high capillary entry pressure to free‐phase CO 2 is desired to serve as the caprock to prevent leakage of CO 2 from the storage reservoir. Nevertheless, the results from this study show that the brine leakage impact to shallow freshwater aquifers through leaky wells might substantially decrease with increasing aquitard permeability values, as long as small aquitard permeability and high capillary entry pressure serve to prevent CO 2 leakage.

Cihan, A.↗

Recent bed rest results and countermeasure development at NASA

Bedrest studies of normal subjects provide opportunities to understand physiologic responses to supine posture and inactivity. Furthermore, head-down tilt has been a valuable procedure to investigate adaptation to microgravity and development of countermeasures to maintain the health and well-being of humans during space-flight. Recent bedrest experiments at NASA have ranged in duration from a few hours to 17 weeks. Acute studies of 6 degrees head-down tilt indicate that elevation of capillary blood pressure from 28 to 34 mm Hg and increased capillary perfusion in tissues of the head cause facial and intracranial edema. Intracranial pressure increases from 2 to 17 mm Hg going from upright posture to 6 degrees head-down tilt. Microvessels of the head have a low capacity to constrict and diminish local perfusion. Elevation of blood and tissue fluid pressures/flow in the head may also explain the higher headward bone density associated with long-term head-down tilt. These mechanistic studies of head-down tilt, along with a better understanding of the relative stresses involved with upright posture and lower body negative pressure, have facilitated development of suitable physiologic countermeasures to maintain astronaut health during microgravity. Presently no exercise hardware is available to provide a blood pressure gradient from head to feet in space. However, recent studies in our laboratory suggest that treadmill exercise using a graded lower-body compression suit and 100 mmHg lower body negative pressure provides equivalent or greater physiologic stress than similar upright exercise on Earth. Therefore, exercise within a lower body negative pressure chamber may provide a cost-effective and simple countermeasure to maintain the cardiovascular and neuro-musculoskeletal systems of astronauts during long-duration flight.

manned↗

Measurements of capillary system degradation

The effects of vibration, flow transients, and warm gas pressurization on capillary acquisition system performance were evaluated. The degradation observed under wide band random and high frequency sinusoidal vibration was of a substantially different nature from that obtained under low frequency sinusoidal vibration. With the former, ingestion of small gas bubbles into the liquid region was correlated by a hydrostatic model, while the capillary stability was destroyed and liquid was lost from the liquid region with the latter. No degradation was observed as a result of flow transients in a flight-type multichannel screen device, but it was observed in a transparent laboratory device. Liquid hydrogen outflow tests were conducted with a multilayer dual-screen-liner system with both helium and hydrogen pressurant gases. The tendency towards dryout of the device with hydrogen pressurant was found to increase with increasing pressurant temperature and length of prepressurization period. Dryout did not occur with helium pressurant.

Warren, R. P.↗

Chronic mitral regurgitation and Doppler estimation of left ventricular filling pressures in patients with heart failure

Previous studies relating Doppler parameters and pulmonary capillary wedge pressures (PCWP) typically exclude patients with severe mitral regurgitation (MR). We evaluated the effects of varying degrees of chronic MR on the Doppler estimation of PCWP. PCWP and mitral Doppler profiles were obtained in 88 patients (mean age 55 +/- 8 years) with severe left ventricular (LV) dysfunction (mean ejection fraction 23% +/- 5%). Patients were classified by severity of MR. Patients with severe MR had greater left atrial areas, LV end-diastolic volumes, and mean PCWPs and lower ejection fractions (each P <.01). In patients with mild MR, multiple echocardiographic parameters correlated with PCWP; however, with worsening MR, only deceleration time strongly related to PCWP. From stepwise multivariate analysis, deceleration time was the best independent predictor of PCWP overall, and it was the only predictor in patients with moderate or severe MR. Doppler-derived early mitral deceleration time reliably predicts PCWP in patients with severe LV dysfunction irrespective of degree of MR.

NASA Discipline Cardiopulmonary↗

Measurement of viscosity of gaseous mixtures at atmospheric pressure

Coefficients of viscosity of various types of gas mixtures, including simulated natural-gas samples, have been measured at atmospheric pressure and room temperature using a modified capillary tube method. Pressure drops across the straight capillary tube section of a thermal mass flowmeter were measured for small, well-defined, volume flow rates for the test gases and for standard air. In this configuration, the flowmeter provides the volumetric flow rates as well as a well-characterized capillary section for differential pressure measurements across it. The coefficients of viscosity of the test gases were calculated using the reported value of 185.6 micro P for the viscosity of air. The coefficients of viscosity for the test mixtures were also calculated using Wilke's approximation of the Chapman-Enskog (C-E) theory. The experimental and calculated values for binary mixtures are in agreement within the reported accuracy of Wilke's approximation of the C-E theory. However, the agreement for multicomponent mixtures is less satisfactory, possible because of the limitations of Wilkes's approximation of the classical dilute-gas state model.

Singh, J. J.↗