Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capillary flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The Plant Water Management Experiments: Soil

A simple means of watering plants in the low-g environment aboard orbiting spacecraft is not obvious. Since the beginning of spaceflight, numerous approaches have been pursued to water plants that seek to maximize plant viability and system reliability, while minimizing crew time and system complexity. We are not there yet. The Plant Water Management (PWM) Soil experiments seek to apply recent advances in low-g capillary fluidics phenomena to the challenges faced by plant growth operations aboard spacecraft. The primary challenge is to establish earth-like flows minimizing low-g specific adaptations required of the plants. This is difficult due to the ever-present fluid physics challenges of poorly-wetting multiphase inertial-visco-capillary flows in geometrically complex conduits and containers. In this paper, we present recent flight results for the PWM Soil experiments where arcillite ‘soil reservoirs’ are arranged in a non-wetting host soil that serves as an O2-breathing wetting barrier. In this way, a largely terrestrial water-soil environment is mimicked where, as liquid is evapo-transpired through the growing plant foliage, the effective water table passively ‘falls’ reducing viscous lengths and increasing water uptake for the plant. We present data from 6 days of 24-7 experiments on the ISS testing 3 different plant root models. We also present and correlate a capillary flow model which captures the primary features of the flow. Our summary is valued for the assessment of current and future low-g plant watering systems employing soil media.

microgravity↗

CVB: the Constrained Vapor Bubble Capillary Experiment on the International Space Station MARANGONI FLOW REGION

The Constrained Vapor Bubble (CVB) is a wickless, grooved heat pipe and we report on a full- scale fluids experiment flown on the International Space Station (ISS). The CVB system consists of a relatively simple setup a quartz cuvette with sharp corners partially filled with either pentane or an ideal mixture of pentane and isohexane as the working fluids. Along with temperature and pressure measurements, the two-dimensional thickness profile of the menisci formed at the corners of the quartz cuvette was determined using the Light Microscopy Module (LMM). Even with the large, millimeter dimensions of the CVB, interfacial forces dominate in these exceedingly small Bond Number systems. The experiments were carried out at various power inputs. Although conceptually simple, the transport processes were found to be very complex with many different regions. At the heated end of the CVB, due to a high temperature gradient, we observed Marangoni flow at some power inputs. This region from the heated end to the central drop region is defined as a Marangoni dominated region. We present a simple analysis based on interfacial phenomena using only measurements from the ISS experiments that lead to a predictive equation for the thickness of the film near the heated end of the CVB. The average pressure gradient for flow in the film is assumed due to the measured capillary pressure at the two ends of the liquid film and that the pressure stress gradient due to cohesion self adjusts to a constant value over a distance L. The boundary conditions are the no slip condition at the wall interface and an interfacial shear stress at the liquid- vapor interface due to the Marangoni stress, which is due to the high temperature gradient. Although the heated end is extremely complex, since it includes three- dimensional variations in radiation, conduction, evaporation, condensation, fluid flow and interfacial forces, we find that using the above simplifying assumptions, a simple successful model can be developed.

heat pipes↗

Electrohydrodynamic heat pipe experiments

Experiments with two electrohydrodynamic heat pipes are reported. Both devices employ an electromechanical flow structure for axial liquid flow and a capillary wicking structure for (1) collection of condensed liquid at the cooled end and (2) distribution of this liquid at the heated end. One device has circumferential grooving for the capillary structure and the other has feltmetal wicking. The experiments successfully demonstrate the electrohydrodynamic heat pipe concept. Compatibility of the two circumferential wick structures with an axial electromechanical flow structure is also demonstrated. A significant mismatch of the capillary groove and electrohydrodynamic pumping capabilities results in severe hydrodynamic burn-out limiting in the first heat pipe. Both devices have very poor over-all thermal conductances of the order of 1-2 W/deg C, reflecting the generally poor heat-transfer properties of the dielectric working fluids required in electrohydrodynamic heat pipes.

Jones, T. B.↗

Gas-flow restrictor

Gas flow restrictor is described, consisting of predetermined length and size of capillary tubing to control flow rate of carrier gas into gas chromatograph of flow rate of sample gas into mass spectrometer inlet system. Length and inner diameter of capillary tubing was estimated with mathematical expressions for viscous flow.

Bastien, G. J.↗

Preliminary investigation of elongational flow of dilute polymer solutions

A tubeless siphon apparatus has been set up to measure extensional flow. In this apparatus, the liquid is continuously drawn into a capillary and, after steady flow has been established, the tube is raised above the liquid surface. With viscoelastic liquids, the flow continues and a column can be lifted from the reservoir. At the capillary entrance, an oscillating bead of excess liquid collects which interferes with both the flow and the measurements. This can be minimized by careful control of the liquid-column height. For homogeneous solutions, the column is symmetrical and tapers steadily from the liquid surface to the capillary entrance, with no bulging. Preliminary results show tensile viscosities 1000 times that of the Trouton coefficient and having a very strong dependence on deformation rate. A concentration-stretch rate-reduced variable scheme is proposed.

Peng, S. T. J.↗

Dynamics of Liquids in Edges and Corners (DYLCO): IML-2 Experiment for the BDPU

Knowledge of the behavior of fluids possessing free surfaces is important to many fluid systems, particularly in space, where the normally subtle effects of surface wettability play a more dramatic and often surprising role. DYLCO for the IML-2 mission was proposed as a simple experiment to probe the particular behavior of capillary surfaces in containers of irregular cross section. Temperature control was utilized to vary the fluid-solid contact angle, a questionable thermodynamic parameter of the system, small changes in which can dramatically influence the configuration, stability, and flow of a capillary surface. Container shapes, test fluid, and temperature ranges were selected for observing both local changes in interface curvature as well as a global change in fluid orientation due to a critical wetting phenomenon. The experiment hardware performed beyond what was expected and fluid interfaces could be readily digitized post flight to show the dependence of the interface curvature on temperature. For each of the containers tested surfaces were observed which did not satisfy the classic equations for the prediction of interface shape with constant contact angle boundary condition. This is explained by the presence of contact angle hysteresis arising from expansion and contraction of the liquid during the heating and cooling steps of the test procedure. More importantly, surfaces exceeding the critical surface curvature required for critical wetting were measured, yet no wetting was observed. These findings are indeed curious and pose key questions concerning the role of hysteresis for this critical wetting phenomena. The stability of such surfaces was determined numerically and it is shown that stability is enhance (reduced) when a surface is in its 'advancing' ('receding') state, The analysis shows complete instability as the critical wetting condition is reached. The case of ideal dynamic wetting is addressed analytically in detail with results of significant flow characteristics presented in closed form. The solutions indicate a square root of T dependence of the capillary 'rise' rate which is corroborated by drop tower tests. The analysis clearly shows that infinite time is necessary for surfaces to reorient at the critical wetting transition.

Langbein, D.↗

Flow in a differentially rotated cylindrical drop at low Reynolds number

A liquid drop held captive between parallel disks that are differentially rotated is a model for the swirling flows induced by crystal rotation in the floating-zone process for growing semiconductor materials. An asymptotic analysis for a cylindrical drop is presented that elucidates the structure of the axisymmetric cellular motions caused by disk rotation at low Reynolds number. Variations of meniscus shape induced by these flows are described in the limit of small capillary number. Most cellular flow fields break the bifurcation point that corresponds to the Plateau-Rayleigh limit for the length of a static drop into two disjoint shape families and lower the maximum stable drop length. This effect is studied by a singular bifurcation analysis.

Harriott, G. M.↗

Measurements of capillary system degradation

The effects of vibration, flow transients, and warm gas pressurization on capillary acquisition system performance were evaluated. The degradation observed under wide band random and high frequency sinusoidal vibration was of a substantially different nature from that obtained under low frequency sinusoidal vibration. With the former, ingestion of small gas bubbles into the liquid region was correlated by a hydrostatic model, while the capillary stability was destroyed and liquid was lost from the liquid region with the latter. No degradation was observed as a result of flow transients in a flight-type multichannel screen device, but it was observed in a transparent laboratory device. Liquid hydrogen outflow tests were conducted with a multilayer dual-screen-liner system with both helium and hydrogen pressurant gases. The tendency towards dryout of the device with hydrogen pressurant was found to increase with increasing pressurant temperature and length of prepressurization period. Dryout did not occur with helium pressurant.

Warren, R. P.↗

Polyimide processing additives

A method has been found for enhancing the melt flow of thermoplastic polyimides during processing. A high molecular weight 422 copoly(amic acid) or copolyimide was fused with approximately 0.05 to 5 pct by weight of a low molecular weight amic acid or imide additive, and this melt was studied by capillary rheometry. Excellent flow and improved composite properties on graphite resulted from the addition of a PMDA-aniline additive to LARC-TPI. Solution viscosity studies imply that amic acid additives temporarily lower molecular weight and, hence, enlarge the processing window. Thus, compositions containing the additive have a lower melt viscosity for a longer time than those unmodified.

Pratt, J. R.↗

Capillary and acceleration wave breakup of liquid jets in axial-flow airstreams

Empirical correlations of reciprocal mean drop diameter with airstream momentum were derived from capillary and acceleration wave breakup of liquid jets atomized by cross stream injection into axial flow airstreams. A scanning radiometer was used to obtain data over an airstream momentum range of 3.7 to 25.7 g/sq cm sec. Transition from capillary to acceleration wave breakup was obtained at a critical Weber-Reynolds number of 1,000,000.

Ingebo, R. D.↗

Correlation of macro and micro cardiovascular function during weightlessness and simulated weightlessness

The investigation of cardiovascular function necessarily involves a consideration of the exchange of substances at the capillary. If cardiovascular function is compromised or in any way altered during exposure to zero gravity in space, then it stands to reason that microvascular function is also modified. We have shown that an increase in cardiac output similar to that reported during simulated weightlessness is associated with a doubling of the number of post-capillary venules and a reduction in the number of arterioles by 35%. If the weightlessness of space travel produces similar changes in cardiopulmonary volume and cardiac output, a reasonable expectation is that astronauts will undergo venous neovascularization. We have developed an animal model in which to correlate microvascular and systemic cardiovascular function. The microcirculatory preparation consists of a lightweight, thermo-neutral chamber implanted around intact skeletal muscle on the back of a rat. Using this technique, the performed microvasculature of the cutaneous maximus muscle may be observed in the conscious, unanesthetized animal. Microcirculatory variables which may be obtained include venular and arteriolar numbers, lengths and diameters, single vessel flow velocities, vasomotion, capillary hematocrit anastomoses and orders of branching. Systemic hemodynamic monitoring of cardiac output by electromagnetic flowmetry, and arterial and venous pressures allows correlation of macro- and microcirculatory changes at the same time, in the same animal. Observed and calculated hemodynamic variables also include pulse pressure, heart rate, stroke volume, total peripheral resistance, aortic compliance, minute work, peak aortic flow velocity and systolic time interval. In this manner, an integrated assessment of total cardiovascular function may be obtained in the same animal without the complicating influence of anesthetics.

NASA Discipline Number 00-00↗

Predictive models for moving contact line flows

Modeling flows with moving contact lines poses the formidable challenge that the usual assumptions of Newtonian fluid and no-slip condition give rise to a well-known singularity. This singularity prevents one from satisfying the contact angle condition to compute the shape of the fluid-fluid interface, a crucial calculation without which design parameters such as the pressure drop needed to move an immiscible 2-fluid system through a solid matrix cannot be evaluated. Some progress has been made for low Capillary number spreading flows. Combining experimental measurements of fluid-fluid interfaces very near the moving contact line with an analytical expression for the interface shape, we can determine a parameter that forms a boundary condition for the macroscopic interface shape when Ca much les than l. This parameter, which plays the role of an "apparent" or macroscopic dynamic contact angle, is shown by the theory to depend on the system geometry through the macroscopic length scale. This theoretically established dependence on geometry allows this parameter to be "transferable" from the geometry of the measurement to any other geometry involving the same material system. Unfortunately this prediction of the theory cannot be tested on Earth.

Rame, Enrique↗

Experiments with an electrohydrodynamic heat pipe

The experimental results with a working model of the electrohydrodynamic (EHD) heat pipe are presented along with descriptions of the experimental device and its operation. Conclusions reached are: (1) EHD flow structures can be used to provide liquid communication between the condenser and evaporator of a heat pipe. (2) The voltage provides a remote electrical servo linkage of possible use in certain thermal control applications. (3) At least one hybrid flow structure, utilizing capillary and electrohydrodynamic forces, has been found functional. Proposed further experiments are discussed.

Jones, T. B.↗

Turbulent transport of He II in active and passive phase separators using slit devices and porous media

The turbulent transport mode of vapor liquid phase separators (VLPS) for He II has been investigated comparing passive porous plug separators with active phase separators (APS) using slits of variable flow paths within a common frame of reference. It is concluded that the basic transport regimes in both devices are identical. An integrated Gorter-Mellink (1949) equation, found previously to predict VLPS results of porous plugs, is employed to analyze APS data published in the literature. It is found that the Gorter-Mellink flow rate parameter for 9-micron and 14-micron APS slit widths are relatively independent of the slit width, having a rate constant of about 9 + or - 10 percent. This agrees with the early heat flow results for He II entropy transport at zero net mass flow in wide capillaries and slits.

Yuan, S. W. K.↗

Operation and performance of the Ciba-Corning 512 coagulation monitor during parabolic flight

The goal was to assess the functionality and evaluate the procedures and operations required to operate the Ciba-Corning 512 Coagulation Monitor during parabolic flight. This monitor determines the clotting characteristics of blood. The analyzer operates by laser detection of the cessation of blood flow in a capillary channel within a test cartridge. Test simulator results were excellent for both pre-and post-flight. In-flight results were not obtained due to the warm-up time required for the simulator. Since this is an electronic function only, the expected results on the simulator would be the same in zero-g.

Gocke, Robyn↗

Investigation of Drop Formation by a Vortex Ring in Microgravity

An investigation of drop formation by a vortex ring propagating through one or more fluid interfaces in microgravity is described. The main goal of the research is to determine the dynamics of drop formation by vortical flows in the capillary limit with large density change across the intel-face. Dimensional analysis shows that in microgravity experiments the capillary limit can be studied using a relatively large vortex ring diameter to facilitate experimental characterization of the interaction. Results obtained in density matched systems are reviewed to illustrate the complex nature of these interactions.

Bernal, Luis P.↗

Documentation of angiotensin II receptors in glomerular epithelial cells

Angiotensin II decreases glomerular filtration rate, renal plasma flow, and glomerular capillary hydraulic conductivity. Although angiotensin II receptors have been demonstrated in mesangial cells and proximal tubule cells, the presence of angiotensin II receptors in glomerular epithelial cells has not previously been shown. Previously, we have reported that angiotensin II caused an accumulation of cAMP and a reorganization of the actin cytoskeleton in cultured glomerular epithelial cells. Current studies were conducted to verify the presence of angiotensin II receptors by immunological and non-peptide receptor ligand binding techniques and to ascertain the activation of intracellular signal transduction in glomerular epithelial cells in response to angiotensin II. Confluent monolayer cultures of glomerular epithelial cells were incubated with angiotensin II, with or without losartan and/or PD-123,319 in the medium. Membrane vesicle preparations were obtained by homogenization of washed cells followed by centrifugation. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis of membrane proteins followed by multiscreen immunoblotting was used to determine the presence of angiotensin II receptor type 1 (AT1) or type 2 (AT2). Angiotensin II-mediated signal transduction in glomerular epithelial cells was studied by measuring the levels of cAMP, using radioimmunoassay. Results obtained in these experiments showed the presence of both AT1 and AT2 receptor types in glomerular epithelial cells. Angiotensin II was found to cause an accumulation of cAMP in glomerular epithelial cells, which could be prevented only by simultaneous use of losartan and PD-123,319, antagonists for AT1 and AT2, respectively. The presence of both AT1 and AT2 receptors and an increase in cAMP indicate that glomerular epithelial cells respond to angiotensin II in a manner distinct from that of mesangial cells or proximal tubular epithelial cells. Our results suggest that glomerular epithelial cells participate in angiotensin II-mediated control of the glomerular filtration barrier.

Non-NASA Center↗