Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity factors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Opportunities for green hydrogen production with land-based wind in the United States

Hydrogen (H 2 ) is an efficient energy carrier and storage mechanism that can supply both stationary and transport energy demand. Rapidly declining renewable energy generation costs; technology innovations in wind, solar, battery storage, and electrolysis; and a global push for more sustainable and secure energy have driven increased interest in green H 2 production. In this study, we develop an H 2 scenario analysis tool to assist in rapid, high-resolution insights into future, green H 2 pathways to achieve policy goals and market competitiveness. Using this tool, we estimate H 2 production and costs for U.S., off-grid scenarios given varying policy and cost scenarios from 2025–2035. Results indicate that achieving economically competitive green H 2 production (below $\$$2/kg) is possible in 2030 with no policy incentives (one site achieves this target), while increasing policy support to include wind and green H 2 production tax credits enables widespread economic viability sooner, with sub-$\$$2/kg LCOH targets achieved by 2025 and 51.7% of sites achieving this target by 2035. Maximizing policy support through prevailing wage and apprenticeship credit multipliers enable widespread economic viability, including sub-$\$$2/kg of green H 2 by 2025 and even negative pricing by 2035. Regions with lowest LCOH values correspond to high wind resource areas and capacity factors. Achieving decarbonization goals with green H 2 depends on technology cost reductions and policy support, with a maximum average LCOH reduction of $\$$23.10 between no and maximum policy support scenarios, and a maximum average LCOH reduction of $\$$25.86 between current, conservative technology costs and 2035 projected technology cost assumptions.

08 HYDROGEN↗

Co-optimization of nuclear reactor flexible power operation and maintenance scheduling

As flexible power operation of nuclear power plants becomes more attractive due to the reduction in fossil-fueled dispatchable generation on energy grids, finding optimal power production strategies that balance revenue generation with operational concerns becomes more complex. This article presents a general framework to aid operators in designing economically optimal long term dispatch strategies for nuclear power plants. The principal novelty is the linking of estimated system remaining useable life (RUL) to strategic operational decisions. It is shown that, depending on the relationship between the fixed costs from maintenance and the associated lost revenue from an outage, it can be economically optimal in the long term to delay a maintenance outage and not perform this alongside refueling. For a given relationship between power ramping and degradation, optimal strategies were found that discouraged load following in some situations while minimizing unnecessary maintenance. It is shown that heavy load following can cause maintenance and refueling outages to diverge due to their inverse relationships with respect to load following, potentially leading to a significant loss in capacity factor. As a result, this general framework can be applied to specific reactor dispatch allowing operators to adapt operational strategies as future grid conditions change.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessing the levelized cost of energy in South Korea

This study evaluates the levelized cost of energy (LCOE) for various energy technologies in the Republic of Korea (Korea) from 2023 to 2050, highlighting cost trajectories and potential crossovers among competing technologies. The analysis projects that, based on our set of assumptions, utility-scale photovoltaic systems achieve lower LCOEs than nuclear by 2030, while fixed offshore wind is expected to become cost-competitive with coal-fired generation around the same time. Floating offshore wind is projected to reach cost parity with coal in the late 2030s. Co-firing with natural gas and green hydrogen is identified as the highest-cost generation option due to high natural gas and green fuel costs and declining capacity utilization. This study further examines the potential for hybrid systems that integrate renewable energy with energy storage to serve as flexible, cost-effective, zero-emission alternatives to green hydrogen-based generation. Spatial LCOE assessments indicate that near-shore offshore wind sites may achieve lower costs despite modest capacity factors, contingent on site-specific factors such as grid integration and social acceptance. The findings indicate that renewable energy technologies are expected to experience continued cost declines, with solar photovoltaic becoming the most competitive energy source in Korea by 2030–2035. Incorporating social costs accelerates this shift from conventional alternatives.

Green hydrogen↗

Modeling the Potential Impact of Storage on the US Power Sector in a Multisector Dynamic Context

The electric power sector is expected to grow in size, importance, and complexity around the world as economies expand and electric supply technologies and demand patterns evolve in significant ways. At the same time the electric power sector may see substantial increases in VRE generating technologies which can add variability and uncertainty to the diurnal and seasonal profile of electric supply. With these forces in play, the emergence of modular, flexible electricity storage technologies may have profound impacts on the operation of electric power systems. Here we reduce a storage modeling gap in MSD models by incorporating grid-based electricity storage into the electric sector dynamics of the Global Change Analysis Model-USA (GCAM-USA) with improved power sector representation. We find a potentially significant role for storage technologies in the future of the U.S. power system, with storage capacity ranging from 7.7 to 14.7 GW in 2050 and 13.9 to 31.6 GW in 2100 across several techno-economic scenarios. We also find that storage can help to smooth variability in residual load arising from evolving electricity demands and the introduction of high shares of VRE to the electric grid. This reduces reliance on high-cost peaking generators, improves system-wide capacity factors, and limits curtailment of VRE.

Patel, Pralit L.↗

Evaluation of thermal energy storage for central receiver concentrating solar power plants under charging cycles through structural assessment

Electricity production by concentrated solar power (CSP) systems has stood out among energy transition alternatives due to their large generation capacity (between 30 MW and 400 MW) and high capacity factor (80%) when incorporating thermal storage systems (TES). Although TES tanks in operation worldwide are made of austenitic steels with remarkable mechanical and anticorrosive properties, operational failures have been reported due to low-cycle fatigue, creep, and the abrupt release of residual stresses generated during tank manufacturing. A critical operation for salt tanks is the initial daily charging operation, given the low fluid level and the thermal gradients between the inventory and the salt entering the tank. This study presents a structural simulation of a 39.6 m-diameter molten salt tank for central receiver CSP plants, accounting for temperature and pressure variations during charging and different sparger ring inlet configurations. The initial pre-stressed condition of the floor, resulting from the manufacture of welded plates, is used as a boundary condition. The fatigue and creep life analyses were performed in accordance with the ASME BPVC and API standards. It was found that the tank's floor is in a less favourable mechanical condition than the wall, due to its initial manufacturing condition and the maximum temperature differences during charging. A critical zone was identified in an area affected by residual stress on the floor and under the sparger ring. The baseline sparger ring configuration, with 52 2-inch-diameter orifices and a flow direction of 90 degrees , results in an average floor stress of approximately 25 MPa and creep damage after 1.2 years of tank operation.

14 SOLAR ENERGY↗

A strategy for automated core design to increase economic viability and minimize fuel fragmentation, relocation, and dispersal susceptibility in high-burnup cores

The nuclear industry aims to increase the cycle length of pressurized water reactors from 18 to 24 months to increase power plant capacity factors and economic viability. These cycle length extensions will inherently require fuel rods to exceed the current peak rod average burnup limit of 62 GWd/MTU. A chief concern of operating beyond the current burnup limit is the fuel fragmentation, relocation, and dispersal (FFRD) phenomenon in which pulverized fuel fragments can axially relocate and escape through a burst in the cladding formed during a loss-of-coolant accident. In this work, we demonstrate an approach for automating core design employing an optimization tool based on a penalty-free, parallel simulated annealing algorithm to produce pressurized water reactor core designs with two different optimization objectives. The two objectives were to produce core designs with (1) mitigated FFRD susceptibility while achieving 24-month cycle lengths (2) maximum cycle length with no regard for the likelihood of FFRD. Batch size was considered in tandem with both cases to maximize economic viability. The PARCS nodal model was the primary reactor physics tool used in the optimizations and used nuclear cross sections calculated with 2D Polaris lattice physics models. Reactor performance and safety characteristics of the optimized cores were verified using high-fidelity Virtual Environment for Reactor Applications models. The core designs produced by the optimization tool are compared with each other and to a high-burnup core design produced and analyzed in previous works to highlight the fuel management strategies that may enhance high-burnup reactor safety and economic viability. The optimized cores satisfied their respective objective functions, producing a maximum cycle length of 720 effective full-power days in one core design and one that may reduce FFRD susceptibility by up to 50% based on the first-order approximation to FFRD risk formulated in this work. The optimized cores met most constraints but exceeded the hot channel factor limit, especially in FFRD cases where fresh fuel carried more power. Furthermore, this highlights the need for future lattice-level optimizations and broader assembly options.

Cycle length↗

Design and full core fuel performance assessment of high burnup cores for 4-loop PWRs

Increasing the fuel discharge burnup of current light water reactors (LWRs) promises reductions in fuel cycle and/or operations costs. By assuming a constant core power density, the economic gain is enabled by better fuel utilization and/or an increased capacity factor. In this effort to investigate greater than 62 MWd/kgU maximum rod average burnup for 110+ kW/l core power density, two core designs have been developed for a standard 17x17, 193 fuel assemblies pressurized water reactor (PWR). The levelized unit cost methodology is employed to evaluate fuel cycle, operation and maintenance, and capital cost impacts and to examine the economic viability of both core design pathways. Core design and optimization are performed using the commercial STUDSVIK code package. Fuel performance analysis is realized in full core configuration via auditing FRAPCON4.1, FAST1.2, and the high-fidelity code BISON. To provide a realistic assessment, the core design process takes into consideration best practices in current PWR core design. It features acceptable performance in terms of various core design constraints on maximum allowable peaking and boron concentration. Gadolinia (Gd2O3) is used as a burnable poison with a maximum of 9 wt% concentration while feeding 89 or 77 fuel assemblies in a 3-batch refueling scheme. Full core fuel performance simulation, which allows for characterization of relevant fuel temperatures, plenum pressures, stresses, and strains, is performed with respect to two bounding burnup levels. Such performance is potentially licensable for the 18-month high burnup core (<68 MWd/kgU peak pin), while it is more challenging for the 24-month high burnup core design pathway (<75 MWd/kgU peak pin). Maximum rod plenum pressure is identified as the most limiting fuel performance parameter. Here, while the scope of the present study focuses on the steady-state plus overpower conditions, the acceptability of the new discharge burnup has to be further assessed by considering uncertainties and impacts under accident scenarios in the future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cost estimation of balance of plant equipment scale up for proton exchange membrane water electrolyzer systems

Water electrolyzers that use electricity to split water into hydrogen and oxygen could be a key technology for increasing hydrogen supply to meet expanded and emerging market applications, although currently the capital costs of these electrolyzers are high. Here we examine cost reductions that might be achieved by scaling up proton exchange membrane (PEM) electrolyzer systems and leveraging economies of scale through balance of plant (BOP) components for system sizes between 1 MW and 1 GW. We estimate BOP equipment capital costs of about $\$$848/kW at 1 MW, potentially decreasing to $\$$87/kW at 1 GW (2022-dollar year basis) with most of the cost reduction happening as systems scale from 1 MW to 100 MW. We find that BOP subsystems hydrogen drying and water knockout benefited the most from economies-of-scale cost reductions, and piping, instrumentation, and housing and power electronics were less impacted. These cost reductions from economies of scale could be more significant than estimated cost reductions from manufacturing scale-up reported in literature. These results add to the knowledge base that could guide optimal system designs that balance process scale-up with plant modularization and numbering-up. We also estimate that scaling up BOP could potentially lower the levelized cost of hydrogen (LCOH) by $\$$1.7-$\$$4.6/kg, depending on the scale-up magnitude and the plant capacity factor.

08 HYDROGEN↗

Hydropower operation in future power grid with various renewable power integration

Hydropower generation may play an increasingly important role in the power grid under increasing contribution of variable renewable sources such as wind and solar. An improved understanding of the changes to hydropower dispatch under future higher VRE grid conditions reveals research gap that should be informed power grid planning and reservoir water releases policies considering multiple other water uses and varying hydrologic condition. Here this study aims to understand the role of hydropower in a changing power grid by employing a production cost model, PLEXOS, across future power system scenarios, planning horizons, and regions. We explore optimized hydropower dispatch to understand its potential role in minimizing the system cost and renewable curtailment. We also examine the sensitivity of hydropower revenue under various grid scenarios of the Eastern U.S. and hydrology conditions. Results indicate hydropower generation follows net load and compensates for the variability of solar and wind generation. Although energy prices are lower during some periods in the future grid scenarios, there is a potential for higher revenue for hydropower by providing both energy and ancillary services during times of stress. Additionally, hydropower revenue is sensitive to hydrology in the SERC region, which we considered as an example. The feasibility of hydropower dispatching with higher ramps between low and high hourly-capacity factors, as indicated in the optimization model, requires further study to consider other water use and ecology constraints.

13 HYDRO ENERGY↗

Downwind coning concept rotor for a 25 MW offshore wind turbine

The size of offshore wind turbines over the next decade is expected to continually increase due to reduced balance of station costs per MW and also the higher wind energy at increased altitudes that can lead to higher capacity factors. However, there are challenges that may limit the degree of upscaling which is possible. In this paper, a two-bladed downwind turbine system is upscaled from 13.2 MW to 25 MW, by redesigning aerodynamics, structures, and controls. In particular, three 25 MW rotors have been developed: V1 is the upscaled model, V2 is a partial redesigned model, and V3 is a fully redesigned model. Despite their radically large sizes, it is found that these 25 MW turbine rotors satisfy this limited set of design drivers at the rated condition and that larger blade lengths are possible with cone-wise load-alignment. In addition, flapwise morphing (varying the cone angle with a wind-speed schedule) is investigated in terms of minimizing mean and fluctuating root bending loads using steady inflow proxies for the maximum and damage equivalent load moments. The resulting series of 25 MW rotors, which are the largest ever designed, can be a useful baseline for additional development and assessment.

17 WIND ENERGY↗

A comparison of the power potential for surface- and seabed-deployed tidal turbines in the San Juan Archipelago, Salish Sea, WA

The San Juan archipelago lies along the axis of tidal movement between Straits of Juan de Fuca and Strait of Georgia in the Salish Sea. The amplitude of the tidal exchange produces significant tidal currents between the islands, as well as in Rosario and Haro Straits. These are of interest as a future source of electrical power generation, given the islands’ dependence on electricity supply by a subsea cable from the mainland. Here, we evaluate the tidal current energy potential in this region through a re-analysis of measurements collected by the National Ocean Service (NOS) and a high-resolution numerical model. Given the considerable variations in water depth and vertical velocity profiles across candidate tidal energy sites, we consider the trade-offs between tidal turbines deployed from a floating platform and those anchored to the seabed. Measurement re-analysis indicates several locations that could support tidal current power generation by MW-scale turbines with an acceptable balance between turbine size, rated power, and capacity factor. Even for relatively large (30 m) turbine diameters, surface-deployed turbines would be expected to produce up to 30 % more electricity than the same turbine deployed near the seabed due to vertical shear, with this difference increasing for smaller diameter turbines. A benchmark comparison at the measurement locations with the highest power generation potential shows relatively good model fidelity, though, even with relatively high resolution, time-average power density disagreements of ± 50 % persist throughout the water column. Nonetheless, the simulation identifies several locations with power generation potential more than twice as high as locations in the measurement re-analysis. These sites were either not surveyed by NOS or excluded due to data quality issues. Altogether, these results demonstrate the complimentary of models and measurements for tidal energy site assessment and suggest that tidal currents could be an important source of electricity generation in the San Juan archipelago.

16 TIDAL AND WAVE POWER↗

Comprehensive techno-economic and life cycle greenhouse gases analysis of green ammonia production utilizing PV and wind energy: Jordan as a case study

Ammonia (NH 3 ) has emerged as a critical player in the global energy transition due to its potential as a low-carbon fuel. Conventional ammonia production methods, primarily through steam methane reforming, are significant contributors to global CO 2 emissions. This study investigates the potential of green ammonia production in Jordan by leveraging the country's abundant solar photovoltaic and wind energy resources. A comprehensive techno-economic and life cycle greenhouse gas analysis was conducted to compare green ammonia production with conventional grey and blue ammonia pathways. Here, the study utilized spatial mapping to assess renewable energy capacity factors across Jordan and optimized the integration of hybrid PV/wind systems with proton exchange membrane (PEM) electrolyzers. The results indicate that the levelized cost of green ammonia (LCOA) in Jordan varies between 900 USD/kg NH 3 and 2500 USD/kg NH 3 which is significantly higher than grey ammonia (similar to 360 USD/kg NH 3 ). Nevertheless, the carbon intensity of green ammonia production (between 0.1 kg CO 2eq /kg NH 3 and 0.5 kg CO 2eq /kg NH 3 ) is much lower than the grey ammonia (1.8 kg CO 2eq /kg NH 3 ). Finally, the results indicate that considering future reductions in capital costs and advancement in renewable energy systems and PEM electrolyzers as well as the ability to sell the co-product O 2 can reduce the LCOA by up to 92 % and make it competitive with grey ammonia.

Green Ammonia↗

Spatial impacts of technological innovations on the levelized cost of energy for offshore wind power plants in the United States

Recent studies predict significant decreases in the future levelized cost of energy (LCOE) of offshore wind energy, much of which is attributed to anticipated cost reductions from technological innovation. This study evaluates the spatial variability of LCOE caused by technology-induced decreases in a range of capital, operational, and financial cost categories. A spatial cost model of fixed-bottom and floating offshore wind plants is used to model the impact across thousands of potential United States sites. A specified change in an individual turbine subsystem cost produces a range of LCOE outcomes due to the varying geospatial characteristics of the considered sites and the nonlinear, interactive dependency on these input parameters; for example, a 10.8% improvement in net capacity factor can reduce LCOE by between 6% and 20% at different sites. This work expands upon the existing offshore wind literature, which typically evaluates cost sensitivities at a single site and does not consider the spatial variance in LCOE. The results suggest that the impact of technological innovations can be considerable and should be considered on a spatial as well as temporal basis when prioritizing technology innovation research or funding decisions to advance offshore wind technologies in the United States.

17 WIND ENERGY↗

Techno-economic analysis and environmental benefits of solar industrial process heating based on parabolic trough collectors

In this work, detailed techno-economic and environmental analyses are conducted for employing a 5 MWt parabolic trough-based solar industrial process heat (SIPH) plant in Salt Lake City, Utah. According to the results, an optimum solar multiple of 1.5 was determined, allowing the plant to generate annual thermal energy of 15389.24 MWth with a capacity factor of 35.1% and levelized cost of heat (LCOH) of $\$ 26.3$/MWth. Considering a 30% investment tax credit and a 30% reduction in the total installed cost could reduce the LCOH to $\$ 19.30$/MWth and $\$ 18.52$/MWth, respectively. Employing parabolic trough collectors could avoid emissions of 3,582,422.47 kg, 147.99 kg, 3,341.66 kg, and 14.32 kg for CO 2 , PM, NOx, and SO 2 , respectively per year compared to a natural gas-based plant. Further, it also caused an annual external cost savings of between $\$ 99,900$ and $\$ 357,004$. Including the external costs in the LCOH analysis shows that the SIPH plant is economically competitive with a natural gas-based plant, further demonstrating its value. A further comparison demonstrated the economic superiority of a parabolic trough-driven IPH plant over a photovoltaic-driven electric boiler plant. In summary, with reducing installed costs and providing incentives, parabolic trough-driven IPH plants will be an economically and environmentally viable option.

14 SOLAR ENERGY↗

Evaluating the Case for Reduced Precious Metal Catalysts in Proton Exchange Membrane Electrolyzers

Proton exchange membrane (PEM) water electrolyzers are a key technology in decarbonizing hydrogen production. Though the market for PEM electrolyzer systems is growing, there are concerns that the cost and availability of precious metal catalysts utilized in today’s commercial systems can limit deployment. Herein, we show that while the availability of Ir should not impede deployment in the near term, the inelasticity of the Ir commodity price is cause for immediate concern. Here we emphasize that diversifying catalyst materials, even with other precious metals, can reduce system costs and mitigate supply chain risk. Furthermore, we analyze the trade-offs between catalyst capital cost and catalyst activity for a range of operating conditions (i.e., capacity factor, electricity price). The framework presented herein is a first step toward establishing performance targets (i.e., activity, stability, material cost) for reduced precious metal and non-precious metal catalysts as a function of PEM electrolyzer operating conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Economic Case for Replacing High-Emitting Peaker Plants with Fuel Cells for Automotive Applications

The identification of clean and cost-effective solutions to replace high-emitting peaker plants and support a just transition is a challenge faced by utilities across the US today. However, falling costs of hydrogen production as well as the widespread availability of fuel cells for automotive applications have made them an attractive option for a zero-emission peak power supply. This study evaluates the techno-economics, operation, and environmental justice impacts of siting a peaker plant based on fuel cells for automotive applications through the lens of the existing Intermountain Power Plant, in order to supply peak power to the Los Angeles basin. Compared to the fossil fuel-fired peakers in operation today, the fuel cell peaker would be lower-cost up to a 17% capacity factor with Inflation Reduction Act incentives while also reducing air pollution in environmental justice communities. With corresponding transmission upgrades, the Intermountain site could host up to a 5 GW fuel cell peaker in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimated Hourly Electricity Demand Profiles for Each County in the Contiguous United States

In this data descriptor, we present hourly electricity demand estimates for each county in the contiguous United States from 2016 to 2023. The demand profiles represent the sum of two components for each county. The first is the weighted average of reported hourly demand profiles for North American Electric Reliability Corporation balancing authority (BA) regions and subregions, scaled to match annual estimates of county-level retail sales and direct use of electricity and weighted by the estimated percentage of county load served by each BA region or subregion. The second is the weighted average of modeled hourly, county- and sector-level distributed photovoltaic (DPV) capacity factor profiles, scaled to match annual estimates of on-site consumption of DPV-generated electricity for each county and weighted by the percentage of consumption attributable to each sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid power plant design for low-carbon hydrogen in the United States

In this study, we provide a nationwide techno-economic analysis of clean hydrogen production powered by a hybrid renewable energy plant for over 50,000 locations in the United States. We leverage the open-source Hybrid Optimization Performance Platform (HOPP) tool to simulate the hourly performance of an off-grid wind-solar plant integrated with a 1-GW polymer exchange membrane electrolyzer system. The levelized cost of hydrogen is calculated for varying technology costs, and tax credits to explore cost sensitivities independent of plant design, performance, and site selection. Our findings suggest that strategies for cost reduction include selecting sites with abundant wind resources, complementary wind and solar resources, and optimizing the sizing of wind and solar assets to maximize the hybrid plant capacity factor. These strategies are linked to increased hydrogen production and reduced electrolyzer stack replacements, thereby lowering the overall cost of hydrogen.

08 HYDROGEN↗