Precise frequency calibration using television video carriers

The availability of inexpensive and quick precise frequency calibration methods is limited. VLF and GPS do offer precise calibration. However, antenna placement, cost of equipment, and calibration time place many restrictions on the user. The USNO maintained line-10 television Time of Coincidence (TOC) of station WTTG, channel 5, Washington, DC requires a frequency stable video carrier. This video carrier, 77.24 MHz is controlled by the same cesium beam standard controlling the TOC of line-10. Excellent frequency comparisons against this video carrier have been accomplished at 95 miles (153 km). With stable propagation and a three foot wire antenna, a part in 10(exp 9) can be determined in a few minutes. Inexpensive field equipment with a synthesized 1 kHz offset from the video carrier offers parts in 10(exp 11) calibrations in a few minutes using an oscilloscope as a phase comparator.

Burkhardt, Edward E.↗

SeaWiFS calibration and algorithm validation

A substantial amount of field research has been completed during this period (1 October 1994 - 31 October 1995). The applicability of different in-flight calibration methods was studied. In addition, various field instruments and new equipment were tested to appraise their usefulness during such calibration activities. The purposes and (expected) results of these field experiments are detailed in separate sections of this report. One section contains a synopsis of calibrations conducted over both land and water targets. A second section contains the results of an experiment conducted to determine the spatial uniformity of surface reflectance at Lake Tahoe, the chosen water calibration site. Advances were also made in the area of radiative transfer software development. An existing exact radiative transfer code, Successive Orders (SO), was modified to provide outputs of the radiance distribution at arbitrary altitudes above a selected calibration target. These modifications were needed to utilize the SO software in radiance-based sensor calibrations. Serious thought was given to the general applicability of various calibration techniques to calibrations conducted over water surfaces. In particular, the practicality of the radiance-based and reflectance-based methods of in-flight radiometric calibration was evaluated.

Parada, Robert J., Jr.↗

A new rapid method of solar simulator calibration

A quick method for checking solar simulator spectra content is presented. The method is based upon a solar cell of extended spectral sensitivity and known absolute response, and a dichroic mirror with the reflection transmission transition close to the peak wavelength of the Thekaekara AMO distribution. It compromises the need for spectral discrimination with the ability to integrate wide spectral regions of the distribution which was considered important due to the spiky nature of the high pressure xenon lamp in common use. The results are expressed in terms of a single number, the blue/red ratio, which, combined with the total (unfiltered) output, provides a simple adequate characterization. Measurements were conducted at eleven major facilities across the country and a total of eighteen simulators were measured including five pulsed units.

Ross, B.↗

Evaluation of Wing Load Calibration and Sensing Methods Using Conventional Strain Gages and a Fiber Optic Sensing System Installed on a Straight Tapered Wing

State-of-the-art instrumentation techniques have provided an opportunity to obtain greater insight into structural wing loads during flight. An investigation was undertaken to research new wing instrumentation and load sensing techniques for measuring accurate in-flight spanwise load distributions on wing structures. A straight tapered wing was instrumented with both conventional foil strain gages at five spanwise wing stations and fiber optic strain sensors at every half inch along the entire wing span. Thirty-nine unique load cases were applied to the wing lower surface using hydraulic actuators to obtain various shear, bending moment, and torque load distributions on the wing. This paper will highlight three load calibration approaches. Conventional linear regression calibration methods were applied to foil strain gages providing a single wing station vertical shear, bending moment, and torque load. Linear regression methods were applied to a fiber optic sensing system to provide bending moment and torque spanwise load distributions. A load sensing scheme using strain derived wing shape information derived from a single load case provided vertical shear and bending moment spanwise load distribution information. Aspects of the three different approaches will be compared and contrasted to inform the reader of the benefits or disadvantages of each. Instrument installation, sensor characteristics, test execution aspects, and recommended calibration techniques will be discussed.

structural mechanics↗

Results of calibrations of the NOAA-11 AVHRR made by reference to calibrated SPOT imagery at White Sands, N.M

The calibration method reported here makes use of the reflectances of several large, uniform areas determined from calibrated and atmospherically corrected SPOT Haute Resolution Visible (HRV) scenes of White Sands, New Mexico. These reflectances were used to predict the radiances in the first two channels of the NOAA-11 Advanced Very High Resolution Radiometer (AVHRR). The digital counts in the AVHRR image corresponding to these known reflectance areas were determined by the use of two image registration techniques. The plots of digital counts versus pixel radiance provided the calibration gains and offsets for the AVHRR. A reduction in the gains of 4 and 13 percent in channels 1 and 2 respectively was found during the period 1988-11-19 to 1990-6-21. An error budget is presented for the method and is extended to the case of cross-calibrating sensors on the same orbital platform in the Earth Observing System (EOS) era.

Nianzeng, Che↗

Calibration of Hot Wire Anemometers. (Latest Citations from the Aerospace Database)

The bibliography contains citations concerning calibration methods and measurement correction schemes for hot wire anemometers. Coverage includes static and dynamic calibration of sensors having single, multiple, cross, and ring wire configurations. Correction methods to account for yaw angle, low-velocity flow, microgravity, wall proximity, and highly fluctuating turbulence, velocity, or temperature are covered. Correction methods are also referenced for installations having multiple sensors. Hot film and laser anemometers, and the use of anemometers in specific industrial and aerospace applications are extensively covered in separate biblographies. (Contains 50-250 citations and includes a subject term index and title list.)

HOT WIRE ANEMOMETERS↗

Aquarius Instrument Science Calibration During the Risk Reduction Phase

This final report presents the results of work performed under NASA Grant NAG512726 during the period 15 January 2003 through 30 June 2004. An analysis was performed of a possible vicarious calibration method for use by Aquarius to monitor and stabilize the absolute and relative calibration of its microwave radiometer. Stationary statistical properties of the brightness temperature (T(sub B)) measured by a low Earth orbiting radiometer operating at 1.4135 GHz are considered as a means of validating its absolute calibration. The global minimum, maximum, and average T(sub B) are considered, together with a vicarious cold reference method that detects the presence of a sharp lower bound on naturally occurring values for T(sub B). Of particular interest is the reliability with which these statistics can be extracted from a realistic distribution of T(sub B) measurements that would be observed by a typical sensor. Simulations of measurements are performed that include the effects of instrument noise and variable environmental factors such as the global water vapor and ocean surface temperature, salinity and wind distributions. Global minima can vary widely due to instrument noise and are not a reliable calibration reference. Global maxima are strongly influenced by several environmental factors as well as instrument noise and are even less stationary. Global averages are largely insensitive to instrument noise and, in most cases, to environmental conditions as well. The global average T(sub B) varies at only the 0.1 K RMS level except in cases of anomalously high winds, when it can increase considerably more. The vicarious cold reference is similarly insensitive to instrument effects and most environmental factors. It is not significantly affected by high wind conditions. The stability of the vicarious reference is, however, found to be somewhat sensitive (at the several tenths of Kelvins level) to variations in the background cold space brightness, T(sub c). The global average is much less sensitive to this parameter and so using two approaches together can be mutually beneficial.

Ruf, Christopher S.↗

Uncertainties for Pre- and Post-Launch Radiometric Calibration of Imaging Spectrometers for Multi-Sensor Applications

An important aspect to using imaging spectrometer data is the radiometric characterization and calibration of the sensors and validation of their data products and doing so with error budgets with known traceability. The radiometric accuracy of a given sensor is important for demonstrating the expected quality of data from the sensor. Known traceability allows data from multiple sensors to be directly comparable as will become more important in the near future with the expected launches of multiple imaging spectrometers from multiple countries, agencies, and commercial entities. The current work describes the state of pre- and post-launch radiometric absolute and relative uncertainties and their role in harmonising on-orbit data. Examples of prelaunch uncertainties based on the calibration of EnMAP and the calibration planned for the CLARREO Pathfinder Mission are presented highlighting recent work in the area of detector-based approaches using tunable laser sources. Post-launch calibration approaches for Pathfinder, EnMAP, CHIME, and DESIS including traditional vicarious calibration methods and the challenges of working with commercial data are presented. The vicarious calibration discussion relies on the example of the recently-available RadCalNet data to describe typical methods and challenges that will be faced when harmonising data between imaging spectrometers as well as with multispectral sensors.

Thome, K.↗

Variations in in-flight absolute radiometric calibration

Variations in the in-flight absolute radiometric calibration of the Coastal Zone Color Scanner and the Thematic Mapper (TM) are reviewed. At short wavelengths, the sensors show a gradual reduction in response, while in the mid-IR the TM shows oscillatory variations. One set of measurements made at White Sands, New Mexico shows anomalous results in TM bands 2 and 4. The results of a reflectance-based and a radiance-based calibration method at White Sands are described. An analysis of the radiance-based method shows the value of such measurements from helicopter altitudes for calibration.

Slater, Philip N.↗

Method and apparatus for precision control of radiometer

A radiometer controller of a radiation detector is provided with a calibration method and apparatus comprised of mounting all temperature sensitive elements of the controller in thermostatically controlled ovens during calibration and measurements, using a selected temperature that is above any which might be reached in the field. The instrument is calibrated in situ by adjusting heater power (EI) to the receptor cavity in the radiometer detector to a predetermined full scale level and is displayed by a meter.

Estey, R. S.↗

Radiometric Calibration Techniques for Signal-of-Opportunity Reflectometers

Bi-static reflection measurements utilizing global navigation satellite service (GNSS) or other signals of opportunity (SoOp) can be used to sense ocean and terrestrial surface properties. End-to-end calibration of GNSS-R has been performed using well-characterized reflection surface (e.g., water), direct path antenna, and receiver gain characterization. We propose an augmented approach using on-board receiver electronics for radiometric calibration of SoOp reflectometers utilizing direct and reflected signal receiving antennas. The method calibrates receiver and correlator gains and offsets utilizing a reference switch and common noise source. On-board electronic calibration sources, such as reference switches, noise diodes and loop-back circuits, have shown great utility in stabilizing total power and correlation microwave radiometer and scatterometer receiver electronics in L-band spaceborne instruments. Application to SoOp instruments is likely to bring several benefits. For example, application to provide short and long time scale calibration stability of the direct path channel, especially in low signal-to-noise ratio configurations, is directly analogous to the microwave radiometer problem. The direct path channel is analogous to the loopback path in a scatterometer to provide a reference of the transmitted power, although the receiver is independent from the reflected path channel. Thus, a common noise source can be used to measure the gain ratio of the two paths. Using these techniques long-term (days to weeks) calibration stability of spaceborne L-band scatterometer and radiometer has been achieved better than 0.1. Similar long-term stability would likely be needed for a spaceborne reflectometer mission to measure terrestrial properties such as soil moisture.

calibrating↗

Derivation of the final OSIRIS-REx OVIRS in-flight radiometric calibration

The OSIRIS-REx Visible and InfraRed Spectrometer (OVIRS) operates over the ∼0.4- to 4.3-μm wavelength range. Radiometric calibration over this broad range requires the use of multiple calibration sources. Initial OVIRS in-flight calibration coefficients were previously computed using ground calibration from visible integrating sphere and IR blackbody sources, cross-calibrated with Earth-observing satellites for visible wavelengths, and adjusted using the spectrum of the OSIRIS-REx mission’s target body, asteroid (101955) Bennu. As part of the final in-flight calibration, we determined that the best calibration method removes out-of-band IR signal leakage prior to radiometric calibration and updated the calibration coefficients accordingly. These final calibration coefficients work well for data where the field of view is filled, and we document the possible artifacts in underfilled spots.

Amy A. Simon↗

TPSAS-NF1676L-10863-DND

One important aspect of successful climate monitoring is satellite calibration. There is at least a 25-year of operational geostationary (GEO) record available for climate studies, if properly calibrated. The Global Space-based Inter-Calibration System (GSICS) project is another effort to provide the climate community consistent calibration across multiple platforms. Also, the Clouds and the Earth's Radiant Energy System (CERES) project, provides consistent GEO retrieved cloud properties and derived broadband fluxes across multiple platforms. This year GSICS is focusing on geostationary visible channel calibration. The GSICS strategy is to use multiple approaches, such as cross-calibrating the GEO radiances against MODIS as a reference, deep convective clouds as bright stable targets, deserts, sun-glint, stars, moon and other model based calibration methods. Each of these methods is independent of each other and can assess the stability of the GEO visible instrument with differing uncertainties. This study focuses on the inter-calibration of the GEO radiances against MODIS as a reference by using collocated, and coincident ray-matched radiances. The advantage of the ray-matching technique is that it provides a full dynamic range of radiances to check the linearity of the GEO visible instrument. This presentation will focus on the technique, some error analysis, comparisons with other methods, and an approach to inter-calibrate historical GEOs before MODIS.

D R Doelling↗

General Matrix Inversion Technique for the Calibration of Electric Field Sensor Arrays on Aircraft Platforms

A matrix calibration procedure has been developed that uniquely relates the electric fields measured at the aircraft with the external vector electric field and net aircraft charge. The calibration method can be generalized to any reasonable combination of electric field measurements and aircraft. A calibration matrix is determined for each aircraft that represents the individual instrument responses to the external electric field. The aircraft geometry and configuration of field mills (FMs) uniquely define the matrix. The matrix can then be inverted to determine the external electric field and net aircraft charge from the FM outputs. A distinct advantage of the method is that if one or more FMs need to be eliminated or deemphasized [e.g., due to a malfunction), it is a simple matter to reinvert the matrix without the malfunctioning FMs. To demonstrate the calibration technique, data are presented from several aircraft programs (ER-2, DC-8, Altus, and Citation).

Mach, D. M.↗

The absolute radiometric calibration of the advanced very high resolution radiometer

The need for independent, redundant absolute radiometric calibration methods is discussed with reference to the Thematic Mapper. Uncertainty requirements for absolute calibration of between 0.5 and 4 percent are defined based on the accuracy of reflectance retrievals at an agricultural site. It is shown that even very approximate atmospheric corrections can reduce the error in reflectance retrieval to 0.02 over the reflectance range 0 to 0.4.

Slater, P. N.↗

Radiometric calibration requirements and atmospheric correction

The need for independent, radundant, absolute radiometric calibration methods is discussed with reference to the Thematic Mapper. Uncertainty requirements for absolute calibration of between 0.5 percent and 4 percent are defined based on the accuracy of reflectance retrievals at an agricultural site. It is shown that even very approximate atmospheric corrections can reduce the error in reflectance retrieval to 0.02 over the reflectance range 0 to 0.4.

Slater, Philip N.↗

A review of some radiometric calibration problems and methods

The in-flight radiometric calibration instrumentation and procedures of the Landsat Thematic Mapper and the high-resolution visible-range instruments of SPOT are illustrated with drawings and diagrams, characterized, and compared. Problems encountered in the laboratory calibration process, minimizing the temporal instability of the systems, identifying anomalies in the electronics in flight, and rechecking the calibration are examined, and it is pointed out that the stability of the calibration systems is less than that of the instruments themselves. The use of carefully measured ground-site data and atmospheric parameters in combination with radiative-transfer models for periodic calibration is recommended.

Slater, P. N.↗

Mode shape analysis using a commercially available peak store video frame buffer

Time exposure photography, sometimes coupled with strobe illumination, is an accepted method for motion analysis that bypasses frame by frame analysis and resynthesis of data. Garden variety video cameras can now exploit this technique using a unique frame buffer that is a non-integrating memory that compares incoming data with that already stored. The device continuously outputs an analog video signal of the stored contents which can then be redigitized and analyzed using conventional equipment. Historically, photographic time exposures have been used to record the displacement envelope of harmonically oscillating structures to show mode shape. Mode shape analysis is crucial, for example, in aeroelastic testing of wind tunnel models. Aerodynamic, inertial, and elastic forces can couple together leading to catastrophic failure of a poorly designed aircraft. This paper will explore the usefulness of the peak store device as a videometric tool and in particular discuss methods for analyzing a targeted vibrating plate using the 'peak store' in conjunction with calibration methods familiar to the close-range videometry community. Results for the first three normal modes will be presented.

Snow, Walter L.↗