At least 127 records · Page 7

The three dimensional motion and stability of a rotating space station-cable - Counterweight configuration

The three dimensional equations of motion for a cable connected space station - counterweight system are developed using a Lagrangian formulation. The system model employed allows for cable and end body damping and restoring effects. The equations are then linearized about the equilibrium motion and nondimensionalized. To first degree, the out-of-plane equations uncouple from the in-plane equations. Therefore, the characteristic polynomials for the in-plane and out-of-plane equations are developed and treated separately. From the general in-plane characteristic equation, necessary conditions for stability are obtained. The Routh-Hurwitz necessary and sufficient conditions for stability are derived for the general out-of-plane characteristic equation. Special cases of the in-plane and out-of-plane equations (such as identical end masses, and when the cable is attached to the centers of mass of the two end bodies) are then examined for stability criteria.

Bainum, P. M.↗

The three dimensional motion and stability of a rotating space station: Cable-counterweight configuration

The three dimensional equations of motion for a cable connected space station--counterweight system are developed using a Lagrangian formulation. The system model employed allows for cable and end body damping and restoring effects. The equations are then linearized about the equilibrium motion and nondimensionalized. To first degree, the out-of-plane equations uncouple from the inplane equations. Therefore, the characteristic polynomials for the in-plane and out-of-plane equations are developed and treated separately. From the general in-plane characteristic equation, necessary conditions for stability are obtained. The Routh-Hurwitz necessary and sufficient conditions for stability are derived for the general out-of-plane characteristic equation. Special cases of the in-plane and out-of-plane equations (such as identical end masses, and when the cable is attached to the centers of mass of the two end bodies) are then examined for stability criteria.

Bainum, P. M.↗

Design, development, fabrication and testing of high temperature Flat Conductor Cable (FCC)

The results are presented of a development program for a flat, 25-conductor signal cable and a flat, 3-conductor power cable. Flat cables employ conductors made of strips or flattened round copper conductors insulated with polyimide films. It is shown that conductor thickness ranges from 0.003 to 0.010 inch, and begins to soften and loose mechanical strength at temperatures above 200 C.

Rigling, W. S.↗

Cables and connectors: A compilation

A technological compilation on devices and techniques for various types of electrical cables and connections is presented. Data are reported under three sections: flat conductor cable technology, newly developed electrical connectors, and miscellaneous articles and information on cables and connector techniques.

Source record↗

Overhead tray for cable test system

System consists of overhead slotted tray, series of compatible adapter cables, and automatic test set which consists of control console and cable-switching console. System reduces hookup time and also reduces cost of fabricating and storing test cables.

Saltz, K. T.↗

Relative stiffness of flat-conductor cable

Bending moment data were taken on ten different cable samples and normalized to express all stiffness factors in terms of cable 5.1 cm in width. Relative stiffness data and nominal physical characteristics are tabulated and presented in graphical form for designers who may be interested in finding torques exerted on critical components by short lengths of cable.

Hankins, J. D.↗

Splicing shielded cables

Simple repair technique retains cable characteristic impedance. Shielded-Cable Splicing Technique retains cable characteristic impedance. Procedure involves splicing inner conductors in staggered pattern, installing jumper braid by heat-shrinking two solder sleeves, and placing insulation sleeve over repaired section and heat-shrinking it. Two possible insulation materials are modified polyvinylidene fluoride and polytetrafluoroethylene.

Lind, W. P.↗

Test report for twinax cable (Rockwell type MB0150-051)

A controlled impedance twisted pair shielded cable was tested to determine the frequency response and effects of mismatched termination. It was found that a long length of this cable, about 100 feet, exhibited a frequency sensitive attenuation roll-off greater than 1.5 db down at 5 MHz. It was also determined that improper termination resulted in losses of 1/2 to 1 db within the frequency range of 200 KHz to greater than 1-1/2 MHz. The test results indicate a possible problem where mismatched connectors are used in video signal cables.

Doland, G. D.↗

Strain relief for power-cable connectors

Easily fabricated grommet composed of polytetrafluoroethylene cylinder, containing U-shaped channels equally spaced around periphery, is used in power cable connectors to relieve strain on cables. Utilization of grommets provides more ease in cable insertion and removal. Potential applications include wiring in large residential and commercial buildings.

Dean, W. T., III↗

High-acceleration cable deployment

Prototype high-acceleration umbilical-cable deployment allows electrical communication between above-ground instrumentation and ballistic projectile below surface. Cable deployment is made up of forebody and afterbody. Foreboy can be separated from afterbody by rocket, or they can be fired as unit at target that stops afterbody on impact (forebody would continue, deploying cable). Similar design could be used in study of sea ice and in other surface-penetration studies.

Barns, C. E.↗

Portable device for use in starting air-start-units for aircraft and having cable lead testing capability

A portable device for starting aircraft engines and the like is disclosed. The device includes a lead testing and motor starting circuit characterized by: (1) a direct current voltage source, (2) a pair of terminal plugs connected with the circuit (each being characterized by a first, second, and third terminal) (3) a pair of manually operable switches for connecting the first terminal of each plug of the pair to the positive side of the voltage source, (4) a circuit lead connecting to the second terminal of each plug the negative side of said source, (5) a pair of electrical cables adapted to connect said first and second terminals of each plug to an air-start unit, and means for connecting each cable of the pair of cables between the first terminal of one plug and the third terminal of the other plug of the pair, and (6) a second pair of manually operable switches for selectivity connecting the third terminal of each plug of the pair to the negative side of the voltage source.

Rosier, W. R.↗

Cables and connectors for Large Space System Technology (LSST)

The effect of the environment and extravehicular activity/remote assembly operations on the cables and connectors for spacecraft with metallic and/or nonmetallic structures was examined. Cable and connector philosophy was outlined for the electrical systems and electronic compartments which contain high-voltage, high-power electrical and electronic equipment. The influence of plasma and particulates on the system is analyzed and the effect of static buildup on the spacecraft electrical system discussed. Conceptual cable and connector designs are assessed for capability to withstand high current and high voltage without danger of arcs and electromagnetic interference. The extravehicular activites required of the space station and/or supply spacecraft crew members to join and inspect the electrical system, using manual or remote assembly construction are also considered.

Dunbar, W. G.↗

Rotating Connection for Electrical Cables

Cable reel provides electrical connections between fixed structure and rotating one. Reel carries power and signal lines while allowing rotating structure to turn up to 360 degrees with respect to fixed structure. Reel replaces sliprings. Can be used to electrically connect arm of robot with body. Reel releases cable to rotating part as it turns and takes up cable as rotating part comes back to its starting position, without tangling, twisting, or kinking.

Manges, D. R.↗

Cable-catenary large antenna concept

Deployable to very large diameters (over 1000 ft), while still remaining compatible with a complete satellite system launch by STS, the cable-catenary antenna comprises: 8 radial deployable boom masts; a deployable hub and feed support center mast; balanced front and back, radial and circumferential catenary cabling for highly accurate (mm) surface control; no interfering cabling in the antenna field; and an RF reflecting mesh supported on the front catenaries. Illustrations show the antenna-satellite system deployed and stowed configurations; the antenna deployment sequence; the design analysis logic; the sizing analysis output, and typical parametric design data.

Akle, W.↗

Cables and fire hazards

Besides describing the experiments conducted to develop a nonflammable cable, this article discusses several considerations regarding other hazards which might result from cable fires, particularly the toxicity and opacity of the fumes emitted by the burning cable. In addition, this article examines the effects of using the Oxygen Index as a gauge of quality control during manufacture.

Zanelli, C.↗

Signal Generator Compensates For Phase Shift In Cable

Stabilized reference signal delivered to remote unit. Signals at two different frequencies transmitted back and forth along cable and mixed to measure propagation delay in cable. Delay-measuring circuitry part of feedback loop constraining overall delay at stable value. Intended for use in system generating precise time and frequency signals, signal-generating subsystem compensates for phase shift in cable.

Sigman, E. H.↗

Coaxial cable connector

A coaxial cable connector is provided, which resists radio frequency breakdown in coaxial cables used in the vacuum of outer space. The connector body surrounds an insulator which includes an easily compressible elastomeric portion. An insulated coaxial cable is prepared so that its insulation projects beyond the outer conductor and compresses the elastomeric portion of the connector insulator.

Caro, Edward R.↗

Safety research of insulating materials of cable for nuclear power generating station

The polymers PE, EPR, PVC, Neoprene, CSP, CLPE, EP and other similar substances are frequently used as insulation and protective covering for cables used in nuclear power generating stations. In order to test these materials for flame retardation, environmental resistance, and cable specifications, they were given the cable normal test, flame test, chemical tests, and subjected to design analysis and loss of coolant accident tests. Material was collected on spark tests and actual experience standards were established through these contributions and technology was accumulated.

Lee, C. K.↗