Vehicle-to-Grid Electric School Bus Commercialization Project

The Vehicle-to-Grid Electric School Bus Commercialization Project was chartered to advance the idea that the batteries in electric vehicles can play a valuable role in supporting the electric grid. As deployment of wind and solar generating resources accelerates to provide an ever-greater share of the nation’s electricity, concurrent investment in solutions that can offset their inherent intermittency will be necessary. Many types of energy storage systems have been proposed, and more than one type will find an economic fit in the grid of the future. Electric vehicle batteries have the potential to provide grid support services in an advantaged manner. The project’s method of exploring this proposition called for development and demonstration of a fleet of vehicle-to-grid (V2G) electric school buses. School buses were chosen because their energy storage capacity is large relative light-duty vehicles; they are typically domiciled in fleet settings; and the number of hours per year they are available for grid support services is high on an absolute basis (generally 80-85% of the hours in a year) and relative to other categories of medium- and heavy-duty vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Depot-Based Vehicle Data for National Analysis of Medium- and Heavy-Duty Electric Vehicle Charging

Medium- and heavy-duty vehicles (MHDVs) are a major source of greenhouse gases and local criteria air pollutants. Electrifying MHDVs may reduce these harmful emissions, which disproportionately impact disadvantaged communities. Due to their relatively high per-vehicle energy needs, consistent fleet operations, and frequent colocation of multiple vehicles at depots, MHDVs may have more spatially and temporally concentrated charging demands than light-duty passenger electric vehicles. That charging concentration means their electrification may require careful advance planning and coordination to manage potential impacts to the electrical grid via charge management or infrastructure upgrades. However, MHDV duty cycles and parking schedules are highly variable across vocations of operation, and there is a shortage of nationally representative, vocationally diverse public data describing typical MHDV operations. This report summarizes the methodology - designed with national representativeness in mind - used to create a new set of data describing typical daily driving distances, dwell durations, and normalized electric vehicle depot charging load curves for MHDVs. The dataset reflects the subset of MHDV operating patterns that may originate from a consistent depot each day and rely on the same depot for charging. In addition to trucks with depot-centric vocational patterns, the data describes operations of transit buses and school buses, each with a depot-centric focus. The dataset is available to the public and suitable for national analysis. It can inform research, infrastructure planning, and policymaking regarding the electrification of MHDVs.

33 ADVANCED PROPULSION SYSTEMS↗

Electric Medium- and Heavy-Duty Vehicle Charging Infrastructure Attributes and Development

Although more established for light-duty vehicles (LDVs), advancements in electric vehicle (EV) charging technology are being made in the medium- and heavy-duty (MD/HD) sector. Progress is also being made with the electrification of MD/HD vehicles, including transit buses, school buses, MD trucks, and HD trucks. The diverse set of operational requirements and duty cycles for each vocation, as well as the range in the size of fleets, present unique charging and infrastructure requirements. This report focuses on charging requirements for MD/HD vehicles and synergies with LDV infrastructure. This analysis leans toward the qualitative rather than quantitative because relevant model inputs are in development and will not be established for a few years, as EV deployments are more mature in the LDV sectors than MD/HD. The report begins with an overview of MD/HD vehicle classes and types of charging, including depot and residential charging, among others (Section 2). Section 3 analyzes the home bases (overnight dwell locations) of existing MD/HD vehicles, with an emphasis on depot and residential home bases, and discusses implications for charging infrastructure. Section 4 discusses the key characteristics for determining if, when, and where MD/HD vehicles can leverage LDV charging infrastructure rather than requiring dedicated chargers. These considerations include electricity demand, connectors, physical space requirements, payment considerations, and impacts on the grid. Section 5 summarizes shared characteristics for MD/HD vehicles that are appropriate for near-term electrification and includes a summary of the outlook of the electric MD/HD vehicle market. The conclusion (Section 6) summarizes the report's findings and outlines areas for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Innovative Advanced Hydrogen Mobile Fueler (Final Technical Report)

The US Department of Energy (DOE) funded a project to design, develop, deploy and analyze the economic viability of an innovative Advanced Hydrogen Mobile Fueler (AHMF). As part of the design activity the project team defined specifications based upon vehicle requirements and compliance with specific fueling performance criteria. The AHMF was originally designed to fuel 10-20 fuel cell vehicles (FCV) per day, consistent with the requirements of the H70 fueling category. The AHMF is able to operate without remote power connections, is modular for easy transport and deployment, and can provide expanded daily capacity and multi-day operations using delivered gaseous hydrogen. Toward the end of the project, due to request from the hydrogen industry and some necessary modifications of the AHMF, the system is now modified to fuel heavy duty vehicles. The project was conducted over two primary phases, each including several key tasks, subtasks, and project milestones. Phase 1 involved the design, development, and construction of the AHMF, moving from a conceptual design through to completion of assembly and testing. In addition to reviewing several different approaches, the team chose to take a conventional station design and modify it for mobile fueling. There were several innovative components included in the design. The high pressure storage was the first to achieve a US Department of Energy (DOE) Special Permit (SP 20391) to transport high pressure hydrogen (95 MPa) in a composite cylinder. The second novel system was a liquid nitrogen (LIN) cooling system with a compact heat exchanger. Without this change, the cooling system would not be able to fit into the AHMF. Phase 2 demonstrated the AHMF by fueling fuel cell buses at a fleet in Pomona, CA. The site was chosen because a temporary fueling solution was required while a fixed station was being installed. The existing permits for the fixed station and non-public access also was a determining factor. Over two months, the buses were fueled 320 times with over 5000 kg of hydrogen from tube trailers. Existing shore power was used, and the average electrical efficiency was 0.13 kWh/kg. The average liquid nitrogen (LIN) consumption was 90.68 scf/kg. The fueling and consumption data was provided to the National Renewable Energy Laboratory (NREL) for analysis. An economic analysis was performed and will be provided in a separate report. The project was successful, but not without challenges and lessons learned. The DOT special permit led the way for the use of high pressure, composite cylinders and is being by multiple other systems and applications. The pandemic along with time for the DOT special permit approval delayed the project for years. The team also believes that hydrogen mobile fueling has a use for the industry, especially during this upcoming phase of expansion. However, it does have its limitations due to high cost to build and operate, and the same permitting challenges as a fixed station. A fully capable system at the speeds and pressures of the AHMF may not be necessary for most applications and would help reduce the cost and increase storage capacity. The on-board generator can be easily replaced with shore power or the wide range of power generation solutions in the marketplace. One of the major results of the project was the development of new code language in National Fire Protection Agency (NFPA) 2 and the International Fire Code (IFC) for on-demand mobile fueling. This will provide guidance for Authorities Having Jurisdiction (AHJ) and user on how to permit temporary fueling sites across the nation.

08 HYDROGEN↗

Spatially Resolved Domicile Charging Demands for Light-, Medium-, and Heavy-Duty Electric Vehicles in Virginia

The use of plug-in electric vehicles (PEVs) and resulting grid impacts are likely to grow rapidly, and evaluation of optimal smart charge management and grid integration strategies is warranted now. Evaluating distribution grid impacts requires fine-grained models of PEV operations to estimate charging loads across diverse vehicles at high spatial resolution. We propose such a model and consider a high-electrification scenario in Richmond and Newport News, Virginia. Our framework considers four categories of vehicle that are amenable to early aggressive electrification: light-duty passenger vehicles (LDV), trucks and vans with a focus on delivery or other local operations, school buses, and transit buses. These vehicles have a relatively consistent domicile, reducing the need for public charging infrastructure rollout to electrify. We apply a recent LDV model and propose new models for each vocation of medium- and heavy-duty vehicle, leveraging telematics data. We demonstrate our framework in Virginia and find energy demands in the region may total 15 GWh day, with most consumed by LDV. However, considering power demand at high spatial resolution reveals a different trend: LDVs have relatively small peak loads at specific sites (peak site demand around 800 kW) compared to average and high demand medium- and heavy-duty vehicle charging sites (peak site demand around 6,000 kW at a transit bus depot, 1,500 kW at a local freight hub, and 1,000 kW at a school). Our framework yields insights on the relative impacts of each vocation and enables future work to tailor grid integration strategies to each vehicle category.

33 ADVANCED PROPULSION SYSTEMS↗

Feasibility and Qualitative Risk Assessment of Fuel Cell Electric Bus Use for Emergency Backup Power for Airport Applications

Airports rely on robust backup power systems to maintain critical operations during emergencies. This paper investigates the feasibility of using hydrogen fuel cell electric buses (FCEBs) as emergency backup power sources, focusing on their technical specifications, operational challenges, and associated risks. Using Portland International Airport as a case study, the analysis evaluates the power output and hydrogen consumption of New Flyer’s 40’ Xcelsior Charge fuel cell buses, to provide power for key airport systems. Additionally, the paper explores the design and layout of how FCEBs can be connected to airport facilities, and addresses safety considerations, hydrogen supply logistics, and electrical compatibility. While FCEBs present significant advantages in terms of sustainability and resilience, their implementation requires careful planning, infrastructure investment, and adherence to safety standards. This research provides actionable insights for airport stakeholders seeking to transition to hydrogen-based backup power system.

08 HYDROGEN↗

Analyzing Impact of Distributed PV Generation on Integrated Transmission & Distribution System Voltage Stability—A Graph Trace Analysis Based Approach

The use of a Graph Trace Analysis (GTA)-based power flow for analyzing the voltage stability of integrated Transmission and Distribution (T&D) networks is discussed in the context of distributed Photovoltaic (PV) generation. The voltage stability of lines and the load carrying capability of buses is analyzed at various PV penetration levels. It is shown that as the PV generation levels increase, an increase in the steady state voltage stability of the system is observed. Moreover, within certain regions of stability margin changes, changes in voltage stability margins of transmission lines are shown to be linearly related to changes in the loading of the lines. Two case studies are presented, where one case study involves a model with eight voltage levels and 784,000 nodes. In one case study, a voltage-stability heat map is used to demonstrate the identification of weak lines and buses.

14 SOLAR ENERGY↗

Study of passenger subjective response to ideal and real-vehicle vibration environments

The stimulus received by subjects tested on the passenger ride quality apparatus (PRQA) is defined. Additional analyses on the data collected from field tests using buses, were conducted to assess the relation between subjective ratings of ride quality and vibrations measured on the buses, and to better define the vibration stimulus measured in the field. The relation of subjective evaluation of simulations of bus rides produced by the DRQA to subjective evaluations of the actual bus rides is discussed. The relative contribution of the seat and floor vibration to human comfort in a simulated aircraft ride environment is discussed along with the determination of equal comfort curves through magnitude estimation.

Kirby, R. H.↗

Analysis of payload bay magnetic fields due to dc power multipoint and single point ground configurations

An analysis of magnetic fields in the Orbiter Payload Bay resulting from the present grounding configuration (structure return) was presented and the amount of improvement that would result from installing wire returns for the three dc power buses was determined. Ac and dc magnetic fields at five points in a cross-section of the bay are calculated for both grounding configurations. Y and Z components of the field at each point are derived in terms of a constant coefficient and the current amplitude of each bus. The dc loads assumed are 100 Amperes for each bus. The ac noise current used is a spectrum 6 db higher than the Orbiter equipment limit for narrowband conducted emissions. It was concluded that installing return wiring to provide a single point ground for the dc Buses in the Payload Bay would reduce the ac and dc magnetic field intensity by approximately 30 db.

Lawton, R. M.↗

Microprocessor systems for industrial process control

Six computers operate synchronously and are interconnected by three independent data buses. Processors control one subsystem. Some can control buses to transfer data at 1 megabit per second. Every 2.5 msec each processor examines list of things to do during next interval. This spacecraft control system could be adapted for controlling complex industrial processes.

Lesh, F. H.↗

Fault-tolerant computer study

A set of building block circuits is described which can be used with commercially available microprocessors and memories to implement fault tolerant distributed computer systems. Each building block circuit is intended for VLSI implementation as a single chip. Several building blocks and associated processor and memory chips form a self checking computer module with self contained input output and interfaces to redundant communications buses. Fault tolerance is achieved by connecting self checking computer modules into a redundant network in which backup buses and computer modules are provided to circumvent failures. The requirements and design methodology which led to the definition of the building block circuits are discussed.

Rennels, D. A.↗

High voltage systems (tube-type microwave)/low voltage system (solid-state microwave) power distribution

SPS satellite power distribution systems are described. The reference Satellite Power System (SPS) concept utilizes high-voltage klystrons to convert the onboard satellite power from dc to RF for transmission to the ground receiving station. The solar array generates this required high voltage and the power is delivered to the klystrons through a power distribution subsystem. An array switching of solar cell submodules is used to maintain bus voltage regulation. Individual klystron dc voltage conversion is performed by centralized converters. The on-board data processing system performs the necessary switching of submodules to maintain voltage regulation. Electrical power output from the solar panels is fed via switch gears into feeder buses and then into main distribution buses to the antenna. Power also is distributed to batteries so that critical functions can be provided through solar eclipses.

Nussberger, A. A.↗

On-board communication for active-control transport aircraft

An investigation of active control communications sponsored by the NASA Langley Research Center is summarized. Particular attention is given to comparative architectures, for which a common set of requirements is generated as a baseline. Most of the requirements are aircraft functional in nature, such as stability and command augmentation, structural load relief, flight path control, flight control linkage, flight monitoring, management, navigation, engine control, and ground communication; the time element, the hazard environment, and the communications capacity estimation are also important factors. The architectures involve several communication technologies, including dedicated links, broadcast busing, and multiplex busing. The multiplex bus system provides the greatest flexibility and installation efficiency. A future homogeneous network system is also proposed, which would be fault and damage tolerant and would, with advanced technology, avoid the problems of designing a very large and flight critical multiplex bus system.

Brock, L. D.↗

A historical overview of the electrical power systems in the US manned and some US unmanned spacecraft

A historical overview of electrical power systems used in the U.S. manned spacecraft and some of the U.S. unmanned spacecraft is presented in this investigation. A time frame of approximately 25 years, the period for 1959 to 1984, is covered in this report. Results indicate that the nominal bus voltage was 28 volts dc in most spacecraft and all other voltage levels were derived from this voltage through such techniques as voltage inversion or rectification, or a combination. Most spacecraft used solar arrays for the main source of power except for those spacecraft that had a relatively short flight duration, or deep spaceprobes that were designed for very long flight duration. Fuel cells were used on Gemini, Apollo, and Space Shuttle (short duration flights) while radioisotope thermoelectric generators were employed on the Pioneer, Jupiter/Saturn, Viking Lander, and Voyager spacecraft (long duration flights). The main dc bus voltage was unregulated on the manned spacecraft with voltage regulation provided at the user loads. A combination of regulated, semiregulated, and unregulated buses were used on the unmanned spacecraft depending on the type of load. For example, scientific instruments were usually connected to regulated buses while fans, relays, etc. were energized from an unregulated bus. Different forms of voltage regulation, such as shunt, buck/boot, and pulse-width modulated regulators, were used. This report includes a comprehensive bibliography on spacecraft electrical power systems for the space programs investigated.

Maisel, J. E.↗

Avionics/crew station integration

The U.S. Navy has been encouraging advanced development concepts aimed at increasing the aircraft instrumentation performance for multi-platform applications of 1990's weapons systems. The three areas covered by the Navy's research and development effort are: System Integration, Technology, and Human Factors. The System Integration objectives are to produce a system architecture easily adaptable to many platforms. Technology objectives are to determine the state of the art for displays, electronics, and controls. The Human Factors objectives are to determine the proper human-machine interfaces so that the ultimate crew station will be capable of providing the pilot with the proper display and controls performance to satisfy the diverse requirements of a fighter, attack, ASW, fixed-wing, rotary-wing, and V/STOL platforms in both a one-man crew or two-man crew matrix. All data/control interface among units of this crew station and other platform subsystems will be via digital data buses and video multiplex buses. No individual discrete signal, data, or control lines will be needed. This paper discusses the six interfaces necessary to ensure the optimum development of this crew station, the predicted platform mission improvements, and the requisite life-cycle cost considerations. This concept will serve as a basis for planning the integration of the necessary hardware and software features in current and future weapons systems.

Mulley, W. G.↗

Some Protocols For Optical-Fiber Digital Communications

One works best in heavy traffic, another, in light traffic. Three protocols proposed for digital communications among stations connected by passive taps to pair of uni-directional optical-fiber buses. Mediate round-robin, bounded-delay access to buses by all stations and particularly suited to fast transmission. Partly because transmission medium passive (no relay stations) and partly because protocols distribute control of network among all stations with provision for addition and deletion of stations (no control stations), communication network able to resist and recover from failures. Implicit token propagates in one direction on one bus and in opposite direction on other bus, minimizing interval of silence between end of one round and beginning of next.

Yeh, Cavour↗

Automatic Detection of Electric Power Troubles (ADEPT)

Automatic Detection of Electric Power Troubles (A DEPT) is an expert system that integrates knowledge from three different suppliers to offer an advanced fault-detection system. It is designed for two modes of operation: real time fault isolation and simulated modeling. Real time fault isolation of components is accomplished on a power system breadboard through the Fault Isolation Expert System (FIES II) interface with a rule system developed in-house. Faults are quickly detected and displayed and the rules and chain of reasoning optionally provided on a laser printer. This system consists of a simulated space station power module using direct-current power supplies for solar arrays on three power buses. For tests of the system's ablilty to locate faults inserted via switches, loads are configured by an INTEL microcomputer and the Symbolics artificial intelligence development system. As these loads are resistive in nature, Ohm's Law is used as the basis for rules by which faults are located. The three-bus system can correct faults automatically where there is a surplus of power available on any of the three buses. Techniques developed and used can be applied readily to other control systems requiring rapid intelligent decisions. Simulated modeling, used for theoretical studies, is implemented using a modified version of Kennedy Space Center's KATE (Knowledge-Based Automatic Test Equipment), FIES II windowing, and an ADEPT knowledge base.

Wang, Caroline↗

DC-DC power converter research for Orbiter/Station power exchange

This project was to produce innovative DC-DC power converter concepts which are appropriate for the power exchange between the Orbiter and the Space Station Freedom (SSF). The new converters must interface three regulated power buses on SSF, which are at different voltages, with three fuel cell power buses on the Orbiter which can be at different voltages and should be tracked independently. Power exchange is to be bi-directional between the SSF and the Orbiter. The new converters must satisfy the above operational requirements with better weight, volume, efficiency, and reliability than is available from the present conventional technology. Two families of zero current DC-DC converters were developed and successfully adapted to this application. Most of the converters developed are new and are presented.

Ehsani, M.↗