Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bulk data transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Modeling Xenon Tank Pressurization using One-Dimensional Thermodynamic and Heat Transfer Equations

As a first step in understanding what ground support equipment (GSE) is required to provide external cooling during the loading of 5,000 kg of xenon into 4 aluminum lined composite overwrapped pressure vessels (COPVs), a modeling analysis was performed using Microsoft Excel. The goals of the analysis were to predict xenon temperature and pressure throughout loading at the launch facility, estimate the time required to load one tank, and to get an early estimate of what provisions for cooling xenon might be needed while the tanks are being filled. The model uses the governing thermodynamic and heat transfer equations to achieve these goals. Results indicate that a single tank can be loaded in about 15 hours with reasonable external coolant requirements. The model developed in this study was successfully validated against flight and test data. The first data set is from the Dawn mission which also utilizes solar electric propulsion with xenon propellant, and the second is test data from the rapid loading of a hydrogen cylindrical COPV. The main benefit of this type of model is that the governing physical equations using bulk fluid solid temperatures can provide a quick and accurate estimate of the state of the propellant throughout loading which is much cheaper in terms of computational time and licensing costs than a Computation Fluid Dynamics (CFD) analysis while capturing the majority of the thermodynamics and heat transfer.

Thermodynamic tank modeling↗

Deposit formation in hydrocarbon rocket fuels with an evaluation of a propane heat transfer correlation

A high pressure fuel coking testing apparatus was designed and developed and was used to evaluate thermal decomposition limits and carbon decomposition rates in heated copper tubes for hydrocarbon fuels. A commercial propane (90% grade) and chemically pure (CP) propane were tested. Heat transfer to supercritical propane was evaluated at 136 atm, bulk fluid velocities of 6 to 30 m/s, and tube wall temperatures in the range of 422 to 811 K. A forced convection heat transfer correlation developed in a previous test effort verified a prediction of most of the experimental data within a + or - 30% range, with good agreement for the CP propane data. No significant differences were apparent in the predictions derived from the correlation when the carbon resistance was included with the film resistance. A post-test scanning electron microprobe analysis indicated occurrences of migration and interdiffusion of copper into the carbon deposit.

Masters, P. A.↗

Effectiveness of Shield Termination Techniques Tested with TEM Cell and Bulk Current Injection

This paper presents experimental results of the effectiveness of various shield termination techniques. Each termination technique is evaluated by two independent noise injection methods; transverse electromagnetic (TEM) cell operated from 3 MHz 400 MHz, and bulk current injection (BCI) operated from 50 kHz 400 MHz. Both single carrier and broadband injection tests were investigated. Recommendations as to how to achieve the best shield transfer impedance (i.e. reduced coupled noise) are made based on the empirical data. Finally, the noise injection techniques themselves are indirectly evaluated by comparing the results obtained from the TEM Cell to those from BCI.

Bradley, Arthur T.↗

Field-theoretic parametrization of low-energy nucleon form factors

A field-theoretic parametrization is proposed for nucleon electromagnetic form factors at momentum transfer less than 600 MeV. The parametrization is part of a larger effective field theory Lagrangian that is Lorentz covariant and chirally symmetric and that has been used to successfully describe bulk and single-particle properties of medium- to heavy-mass nuclei. The parametrization is based on vector meson dominance and a derivative expansion of nucleon couplings to the electromagnetic fields. At lowest order in the expansion, it is possible to fit all four parameters to modern data on the rms radii of the nucleon form factors. At next-to-leading order it is possible to fit the form factors to within a few percent up to momentum transfers of 600 MeV. The vector meson dominance contributions are crucial in this fit, because a simple expansion in powers of momentum transfer would require many terms to achieve comparable accuracy. The ability to fit single-nucleon form factors up to 600 MeV momentum transfer makes possible the study of two-body electromagnetic exchange currents within this effective field theory framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Boiling Heat Transfer Mechanisms in Earth and Low Gravity: Boundary Condition and Heater Aspect Ratio Effects

Boiling is a complex phenomenon where hydrodynamics, heat transfer, mass transfer, and interfacial phenomena are tightly interwoven. An understanding of boiling and critical heat flux in microgravity environments is of importance to space based hardware and processes such as heat exchange, cryogenic fuel storage and transportation, electronic cooling, and material processing due to the large amounts of heat that can be removed with relatively little increase in temperature. Although research in this area has been performed in the past four decades, the mechanisms by which heat is removed from surfaces in microgravity are still unclear. Recently, time and space resolved heat transfer data were obtained in both earth and low gravity environments using an array of microheaters varying in size between 100 microns to 700 microns. These heaters were operated in both constant temperature as well as constant heat flux mode. Heat transfer under nucleating bubbles in earth gravity were directly measured using a microheater array with 100 m resolution operated in constant temperature mode with low and high subcooled bulk liquid along with images from below and from the side. The individual bubble departure diameter and energy transfer were larger with low subcooling but the departure frequency increased at high subcooling, resulting in higher overall heat transfer. The bubble growth for both subcoolings was primarily due to energy transfer from the superheated liquid layer relatively little was due to wall heat transfer during the bubble growth process. Oscillating bubbles and sliding bubbles were also observed in highly subcooled boiling. Transient conduction and/or microconvection was the dominant heat transfer mechanism in the above cases. A transient conduction model was developed and compared with the experimental data with good agreement. Data was also obtained with the heater array operated in a constant heat flux mode and measuring the temperature distribution across the array during boiling. The instantaneous heat transfer into the substrate was numerically determined and subtracted from the supplied heat to obtain the wall to liquid heat flux.

Kim, Jungho↗

Periodic and stochastic thermal modulation of protein folding kinetics

Chemical reactions are usually observed either by relaxation of a bulk sample after applying a sudden external perturbation, or by intrinsic fluctuations of a few molecules. Here we show that the two ideas can be combined to measure protein folding kinetics, either by periodic thermal modulation, or by creating artificial thermal noise that greatly exceeds natural thermal fluctuations. We study the folding reaction of the enzyme phosphoglycerate kinase driven by periodic temperature waveforms. As the temperature waveform unfolds and refolds the protein, its fluorescence color changes due to FRET (Förster resonant Energy Transfer) of two donor/acceptor fluorophores labeling the protein. We adapt a simple model of periodically driven kinetics that nicely fits the data at all temperatures and driving frequencies: The phase shifts of the periodic donor and acceptor fluorescence signals as a function of driving frequency reveal reaction rates. We also drive the reaction with stochastic temperature waveforms that produce thermal fluctuations much greater than natural fluctuations in the bulk. Such artificial thermal noise allows the recovery of weak underlying signals due to protein folding kinetics. This opens up the possibility for future detection of a stochastic resonance for protein folding subject to noise with controllable amplitude.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the prediction of the behavior of the velocity, temperature and humidity fields above a thermally stratified air-water interface

A turbulent kinetic energy-dissipation (k-epsilon) model is employed to numerically simulate the behavior of the mean velocity, temperature and humidity fields, along with such second-order statistics as Reynolds stresses, turbulent heat and mass transfer correlation, and bulk transfer coefficients in the boundary layer above wind-generated laboratory waves. The k and epsilon equations have been properly modified to account for thermal stratification, the presence of free surface, and favorable pressure gradient effects. Predictions are compared with available data.

Papadimitrakis, Yiannis A.↗

Analytic Modeling of Pressurization and Cryogenic Propellant

An analytic model for pressurization and cryogenic propellant conditions during all mission phases of any liquid rocket based vehicle has been developed and validated. The model assumes the propellant tanks to be divided into five nodes and also implements an empirical correlation for liquid stratification if desired. The five nodes include a tank wall node exposed to ullage gas, an ullage gas node, a saturated propellant vapor node at the liquid-vapor interface, a liquid node, and a tank wall node exposed to liquid. The conservation equations of mass and energy are then applied across all the node boundaries and, with the use of perfect gas assumptions, explicit solutions for ullage and liquid conditions are derived. All fluid properties are updated real time using NIST Refprop.1 Further, mass transfer at the liquid-vapor interface is included in the form of evaporation, bulk boiling of liquid propellant, and condensation given the appropriate conditions for each. Model validation has proven highly successful against previous analytic models and various Saturn era test data and reasonably successful against more recent LH2 tank self pressurization ground test data. Finally, this model has been applied to numerous design iterations for the Altair Lunar Lander, Ares V Core Stage, and Ares V Earth Departure Stage in order to characterize Helium and autogenous pressurant requirements, propellant lost to evaporation and thermodynamic venting to maintain propellant conditions, and non-uniform tank draining in configurations utilizing multiple LH2 or LO2 propellant tanks. In conclusion, this model provides an accurate and efficient means of analyzing multiple design configurations for any cryogenic propellant tank in launch, low-acceleration coast, or in-space maneuvering and supplies the user with pressurization requirements, unusable propellants from evaporation and liquid stratification, and general ullage gas, liquid, and tank wall conditions as functions of time.

Corpening, Jeremy H.↗

OECD MCCI project Melt Eruption Test (MET) design report, Rev. 2. April 15, 2003.

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core-concrete interaction when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. The Melt Coolability and Concrete Interaction (MCCI) program is pursuing separate effect tests to examine the viability of the melt coolability mechanisms identified as part of the MACE program. These mechanisms include bulk cooling, water ingression, volcanic eruptions, and crust breach. At the second PRG meeting held at ANL on 22-23 October 2002, a preliminary design1 for a separate effects test to investigate the melt eruption cooling mechanism was presented for PRG review. At this meeting, NUPEC made several recommendations on the experiment approach aimed at optimizing the chances of achieving a floating crust boundary condition in this test. The principal recommendation was to incorporate a mortar sidewall liner into the test design, since data from the COTELS experiment program indicates that corium does not form a strong mechanical bond with this material. Other recommendations included: (i) reduction of the electrode elevation to well below the melt upper surface elevation (since the crust may bond to these solid surfaces), and (ii) favorably taper the mortar liner to facilitate crust detachment and relocation during the experiment. Finally, as a precursor to implementing these modifications, the PRG recommended the development of a design for a small-scale scoping test intended to verify the ability of the mortar liner to preclude formation of an anchored bridge crust under core-concrete interaction conditions. This revised Melt Eruption Test (MET) plan is intended to satisfy these PRG recommendations. Specifically, the revised plan focuses on providing data on the extent of crust growth and melt eruptions as a function of gas sparging rate under well-controlled experiment conditions, including a floating crust boundary condition. The overall objective of MET is to determine to what extent core debris is rendered coolable by eruptive-type processes that breach the crust that rests upon the melt. The specific objectives of this test are as follows: (1) Evaluate the augmentation in surface heat flux during periods of melt eruption; (2) Evaluate the melt entrainment coefficient from the heat flux and gas flow rate data for input into models that calculate ex-vessel debris coolability; (3) Characterize the morphology and coolability of debris resulting from eruptive processes that transport melt into overlying water; and (4) Discriminate between periods when eruptions take the form of particle ejections into overlying water, leading to a porous particle bed, and single-phase extrusions, which lead to volcano-type structures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Octane Requirements of Lean Mixed-Mode Combustion in a Direct-Injection Spark-Ignition Engine

Here, this study investigates the octane requirements of a hybrid flame propagation and controlled autoignition mode referred to as mixed-mode combustion (MMC), which allows for strong control over combustion parameters via a spark-initiated deflagration phase. Due to the throughput limitations associated with both experiments and 3-D computational fluid dynamics calculations, a hybrid 0-D and 1-D modeling methodology was developed, supported by experimental validation data. This modeling approach relied on 1-D, two-zone engine simulations to predict bulk in-cylinder thermodynamic conditions over a range of engine speeds, compression ratios, intake pressures, trapped residual levels, fueling rates, and spark timings. Those predictions were then transferred to a 0-D chemical kinetic model, which was used to evaluate the autoignition behavior of fuels when subjected to temperature–pressure trajectories of interest. Finally, the predicted autoignition phasings were screened relative to the progress of the modeled deflagration-based combustion in order to determine if an operating condition was feasible or infeasible due to knock or stability limits. The combined modeling and experimental results reveal that MMC has an octane requirement similar to modern stoichiometric spark-ignition engines in that fuels with high research octane number (RON) and high octane sensitivity (S) enable higher loads. Experimental trends with varying RON and S were well predicted by the model for 1000 and 1400 rpm, confirming its utility in identifying the compatibility of a fuel’s autoignition behavior with an engine configuration and operating strategy. However, the model was not effective in predicting (nor designed to predict) operability limits due to cycle-to-cycle variations, which experimentally inhibited operation of some fuels at 2000 rpm. Putting the operable limits and efficiency from MMC in the context of a state-of-the-art engine, the MMC showed superior efficiencies over the range investigated, demonstrating the potential to further improve fuel economy.

33 ADVANCED PROPULSION SYSTEMS↗

Photocurrent in bulk heterojunction solar cells with similar electron and hole mean free path

We present photocurrents at several temperatures carried out in a bulk heterojunction photovoltaic device. To explain the results, we developed an analytical model assuming non-injecting contacts and equal mean free paths for electrons and holes. The fitting of the equation to the experimental data provided the temperature evolution of the charge transfer state dissociation probability (P) and μτ, where μ is the charge carrier mobility and τ is the charge carrier lifetime. The photocurrent expression tends towards a saturation value of eGPL for high electric fields, where GP is the generation rate of charge carriers.

14 SOLAR ENERGY↗

Tetragonal Lysozyme, From Monomer to Crystal

The data now leads us to a comprehensive model for the process by which tetragonal lysozyme crystals are nucleated and subsequently grow. Lysozyme is typically desolubilized by addition of ionic salts. The salt anions bind to basic and other sites on the protein and promote protein-protein interactions, i.e., initiate the nucleation self assembly process. Formation of protein-protein interactions occurs at the expense of the protein-anion interactions, with the anions being released to the solution. The association follows a defined pattern, forming the "head to side" interactions of the crystal 4(3) helix. The presence of the high salt also promotes hydrophobic interactions between the protein molecules, further tightening their interaction. The solute assembly process persists after crystal nucleation, and the 4(3) helical structures form the subsequent growth units. AFM measurements show that the growth units follow the dimensions of these helices, and that those on the surface are more compact about the c-axis than in the bulk crystal, with adjacent helices riot being in contact. This further supports the role of hydrophobic interactions, as the surface is still in contact with the bulk solution. Once buried within the crystal the protein:salt ratio radically changes and the hydrophobic interactions relax to those measured crystallographically. Thus the crystal growth process recapitulates the initial stages of the nucleation process, and the two seamlessly merge. Experimental evidence, based upon face growth rate, AFM, and fluorescence energy transfer data, for a postulated model of the nucleation of tetragonal lysozyme crystals and how it transitions into crystal growth will be presented.

Pusey, Marc L.↗

MODELING AND SIMULATIONS OF DETERIORATED TURBULENT HEAT TRANSFER IN WALL HEATED CYLINDRICAL TUBE

The paper discusses the modeling and simulations of Deteriorated Turbulent Heat Transfer (DTHT) for a wall-heated fluid flows, which can be observed in gas-cooled nuclear power reactors during Pressurized Conduction Cooldown (PCC) event due to loss of force circulation flow. The DTHT regime is defined as the deterioration of normal turbulent heat transport due to increase of acceleration and buoyancy forces. The Computational Fluid Dynamics (CFD) tools such as Nek5000 and STAR-CCM+ can help to analyze the DTHT phenomena in reactors for efficient thermal-fluid designs. 3D CFD non-isothermal modeling and simulations were performed in a wall-heated circular tube. The simulation results were verified with two different CFD tools, Nek5000 and STAR-CCM+, and validated with an experimental data. The predicted bulk temperatures were identical in both CFD tools, as expected. Good agreement between simulated results and measured data were obtained for wall temperatures along the tube axis using Nek5000. In STAR-CCM+, the under-predicted wall temperatures were mainly due to higher turbulence in the wall region. In STAR-CCM+, the predicted DTHT was over 48% at outlet when compared to inlet heat transfer values.

deteriorated turbulent heat transfer↗

VIEW: A modification of the RAVFAC view factor program for use with the NASTRAN thermal analyzer

The NASTRAN thermal analyzer will include the capability to perform complete thermal analyses on structures. One of the inputs to NASTRAN required to simulate radiative heat transfer between surfaces will be the view factors (also called shape factors, form factors, configuration factors) between those surfaces. The purpose of the VIEW program is to compute these view factors and produce appropriate RADMTX and RADLST output to be used as NASTRAN bulk data.

Puccinelli, E. F.↗

Supercritical oxygen heat transfer

Heat transfer to supercritical oxygen was experimentally measured in electrical heated tubes. Experimental data were obtained for pressures ranging from 17 to 34.5 MPa (2460 to 5000 psia), and heat fluxes from 2 to 90 million w/sq cm (1.2 to 55 Btu/(sq in. sec)). Bulk temperatures ranged from 96 to 217 K (173 to 391 R). Experimental data obtained by other investigators were added to this to increase the range of pressure down to 2 MPa (290 psia) and increase the range of bulk temperature up to 566 K (1019 R). From this compilation of experimental data a correlating equation was developed which predicts over 95% of the experimental data within + or - 30%.

Spencer, R. G.↗

Experimental study of the impact of scavenging efficiency on diesel combustion in an opposed-piston two-stroke engine

The opposed-piston two-stroke (OP2S) engine is a promising alternative powertrain technology that can offer thermal and brake efficiency improvements over conventional four-stroke engines. In recent years, many of the technical barriers of the OP2S engine architecture have been overcome. However, there is still a need for fundamental studies to provide insight into the scavenging and combustion processes of the OP2S engine to help design and operate the most efficient combustion systems using this engine architecture. This work aims to provide such insights by analyzing experimental data collected on a 3-cylinder, 4.9 L OP2S engine. Specifically, a scavenging efficiency sweep, an engine speed sweep with a constant scavenging efficiency, and an engine speed with a constant pressure differential across the engine were studied in detail. It was found that in diesel combustion, as the scavenging efficiency decreased, the increase in temperature of the hot, internal residuals resulted in a significant increase in heat transfer. Despite lowering pumping losses, this resulted in an overall decrease in brake efficiency. When the bulk thermodynamic conditions of two different scavenging efficiency cases (67% and 72%) were matched at port closing, the lower scavenging efficiency case still displayed a 0.7 percentage point penalty in net thermal efficiency and an increase in engine-out indicated specific emissions of NOx of 18% due to residual stratification in the cylinder. The results presented in this work show that the optimal breathing strategy in diesel combustion on an OP2S engine architecture is one that results in a slightly under-scavenged environment at port closing. However, the results did show potential system-level efficiency benefits of decreasing scavenging efficiency, meaning that alternative fuels and combustion strategies without the constraints of diesel combustion could achieve system-level efficiency gains by running significantly under-scavenged.

Engineering↗

Local Heat-Transfer Measurements for Forced Convection of Hydrogen and Helium at Surface Temperatures Up to 5600 Deg R

Local values of heat-transfer coefficients and average friction coefficients were measured experimentally for helium and hydrogen gas flowing through an electrically heated tungsten tube with a length-diameter ratio of 77 for the following range of conditions: local surface temperatures up to 5600° R, local Reynolds number from 7600 to,39,500, local ratios of surface-to-bulk gas temperature up to 5.6, and heat flux up to 1,700,000 Btu per hour per square foot. A comparison of local heat-transfer coefficients for helium and hydrogen gas is made for several types of wall temperature distribution, which determines whether the data can be correlated by a Dittus-Boelter type equation. A wall temperature distribution for hydrogen is compared with one for helium and found to be essentially the same; this result demonstrates that q dissociation of hydrogen at the tube wall for wall temperatures up to 5200O R has little or no effect on the wall temperature distribution.

Maynard F Taylor↗

Microwave Soil Moisture Retrieval Under Trees

Soil moisture is recognized as an important component of the water, energy, and carbon cycles at the interface between the Earth's surface and atmosphere. Current baseline soil moisture retrieval algorithms for microwave space missions have been developed and validated only over grasslands, agricultural crops, and generally light to moderate vegetation. Tree areas have commonly been excluded from operational soil moisture retrieval plans due to the large expected impact of trees on masking the microwave response to the underlying soil moisture. Our understanding of the microwave properties of trees of various sizes and their effect on soil moisture retrieval algorithms at L band is presently limited, although research efforts are ongoing in Europe, the United States, and elsewhere to remedy this situation. As part of this research, a coordinated sequence of field measurements involving the ComRAD (for Combined Radar/Radiometer) active/passive microwave truck instrument system has been undertaken. Jointly developed and operated by NASA Goddard Space Flight Center and George Washington University, ComRAD consists of dual-polarized 1.4 GHz total-power radiometers (LH, LV) and a quad-polarized 1.25 GHz L band radar sharing a single parabolic dish antenna with a novel broadband stacked patch dual-polarized feed, a quad-polarized 4.75 GHz C band radar, and a single channel 10 GHz XHH radar. The instruments are deployed on a mobile truck with an 19-m hydraulic boom and share common control software; real-time calibrated signals, and the capability for automated data collection for unattended operation. Most microwave soil moisture retrieval algorithms developed for use at L band frequencies are based on the tau-omega model, a simplified zero-order radiative transfer approach where scattering is largely ignored and vegetation canopies are generally treated as a bulk attenuating layer. In this approach, vegetation effects are parameterized by tau and omega, the microwave vegetation opacity and single scattering albedo. One goal of our current research is to determine whether the tau-omega model can work for tree canopies given the increased scatter from trees compared to grasses and crops, and. if so, what are effective values for tau and omega for trees.

O'Neill, P.↗