Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building load profile modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of Testing Station for Prototype Rover Thermal Subsystem

In order to successfully and efficiently explore the moon or other planets, a vehicle must be built to assist astronauts as they travel across the surface. One concept created to meet this need is NASA's Space Exploration Vehicle (SEV). The SEV, a small pressurized cabin integrated onto a 12-wheeled chassis, can support two astronauts up to 14 days. Engineers are currently developing the second generation of the SEV, with the goal of being faster, more robust, and able to carry a heavier payload. In order to function properly, the rover must dissipate heat produced during operation and maintain an appropriate temperature profile inside the rover. If these activities do not occur, components of the rover will start to break down, eventually leading to the failure of the rover. On the rover, these requirements are the responsibility of the thermal subsystem. My project for the summer was to design and build a testing station to facilitate the design and testing of the new thermal subsystem. As the rover develops, initial low fidelity parts can be interchanged for the high fidelity parts used on the rover. Based on a schematic of the proposed thermal system, I sized and selected parts for each of the components in the thermal subsystem. For the components in the system that produced heat but had not yet been finalized or fabricated, I used power resistors to model their load patterns. I also selected all of the fittings to put the system together and a mounting platform to support the testing station. Finally, I implemented sensors at various points in the system to measure the temperature, pressure, and flow rate, and a data acquisition system to collect this information. In the future, the information from these sensors will be used to study the behavior of the subsystem under different conditions and select the best part for the rover.

Burlingame, Kaitlin↗

Short-term apartment-level load forecasting using a modified neural network with selected auto-regressive features

Residential electricity load profiles and their diversity have become increasingly important to realize the benefits of Smart or Transactive Energy Networks (TENs). An important element of TENs will be practical, accurate, and implementable residential load forecasting techniques. While there have been many approaches to short-term load forecasting, few have included forecasting for individual households, partly because the high volatility and idiosyncrasies present in individual household load data can pose significant challenges. In this study, we develop a Convolutional Long Short-Term Memory-based neural network with Selected Autoregressive Features (termed a CLSAF model) to improve short-term household electricity load forecasting accuracy by employing three strategies: autoregressive features selection, exogenous features selection, and a “default” state to avoid overfitting at times of high load volatility. We include aggregations of apartments to floor and building level, because utilities may favor transactive approaches that rely on aggregator models, e.g., a cluster of consumers as opposed to an individual. We demonstrate that the CLSAF model, by virtue of its enhanced feature representation and modest computational resources, can accomplish load forecasting in a multi-family residential building across three spatial granularities (individual apartment/household, floor, and building levels), with an accuracy improvement of up to 25% compared to a persistence model. We propose a data screening technique to characterize time-series electricity-load data. This technique is suitable for integration into a TEN ecosystem and allows one to estimate confidence levels of the load forecasts to optimize computational resources and the risks associated with uncertain forecasts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma: Preprint

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Global Influence of Organic Aerosol Volatility on Aerosol Microphysical Processes: Composition and Number

We present MATRIX-VBS, a new aerosol scheme that simulates organic partitioning in an aerosol microphysics model, as part of the NASA GISS ModelE Earth System Model. MATRIX-VBS builds on its predecessor aerosol microphysics model MATRIX (Bauer et al., 2008, https://doi.org/10.5194/acp-8-6003-2008) and was developed in the box model framework (Gao et al., 2017, https://doi.org/10.5194/gmd-10-751-2017). The scheme features the inclusion of organic partitioning between the gas and particle phases and the photochemical aging process using the volatility-basis set (Donahue et al., 2006, https://doi.org/10.1021/es052297c). To assess the performance of the new model, we compared its mass concentration, number concentration, and activated number concentration to the original scheme MATRIX, and evaluated its mass concentrations in four seasons against data from the NASA Atmospheric Tomography Mission (ATom) aircraft campaign. Results from MATRIX-VBS show that organics are transported further away from their source, and their mass concentration increases aloft and decreases at the surface compared to those in MATRIX. The mass concentration of organics at the surface agrees well with measurements, and there are discrepancies for vertical profiles aloft. In the new scheme, the global mass load of organic aerosols increased by 50%, there is also an increased number of particles at the surface and fewer activated ones in most regions. The new scheme presents advanced and more comprehensive capability in simulating aerosol processes.

aerosol modeling↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

Hot, cold, or just right? An infrared biometric sensor to improve occupant comfort and reduce overcooling in buildings via closed-loop control

To improve occupant comfort and save energy in buildings, we have developed a closed-loop air conditioning (AC) sensor-controller that predicts occupant thermal sensation from the thermographic measurement of skin temperature distribution, then uses this information to reduce overcooling (cooling-energy overuse that discomforts occupants) by regulating AC output. Taking measures to protect privacy, it combines thermal-infrared (TIR) and color (visible spectrum) cameras with machine vision to measure the skin-surface temperature profile. Since the human thermoregulation system uses skin blood flow to maintain thermoneutrality, the distribution of skin temperature can be used to predict warm, neutral, and cool thermal states. We conducted a series of human-subject thermal-sensation trials in cold-to-hot environments, measuring skin temperatures and recording thermal sensation votes. We then trained random-forest classification machine-learning models (classifiers) to estimate thermal sensation from skin temperatures or skin-temperature differences. The estimated thermal sensation was input to a proportional integral (PI) control algorithm for the AC, targeting a sensation level between neutral and warm. Our sensor-controller includes a sensor assembly, server software, and client software. The server software orients the cameras and transmits images to the client software, which in turn assesses occupant skin temperature distribution, estimates occupant thermal sensation, and controls AC operation. A demonstration conducted in a conference room in an office building near Houston, TX showed that our system reduced overcooling, decreasing AC load by 42% when the room was occupied while improving occupant comfort (fraction of “comfortable” votes) by 15 percentage points.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Performance of Commercial Building Load Flexibility Using Model Predictive Control

Model Predictive Control (MPC) applied to buildings is starting to see some commercial adoption by companies. However, it is hard to estimate if relative energy cost savings are enough to justify the cost of MPC implementation with few reported demonstrations. In small commercial and residential buildings, a one size-fits-all solution can help reduce implementation costs, while in very large buildings or districts the potential energy cost savings magnitude can cover more tailored solutions. This estimation becomes harder for medium to large commercial buildings, where a one-size-fits-all solution cannot be adopted and potential energy cost savings might not be sufficient to cover a tailored solution. Therefore, value propositions in addition to energy efficiency alone can make MPC technology more attractive through additional energy cost savings. One such value proposition is load shifting in response to dynamic electricity prices. On this aspect, MPC is a key technology to unlock building thermal mass for energy flexibility in response to electric grid conditions. This study shows the experimental results of MPC control of an office building in Berkeley, where different dynamic electricity price profiles were used in the MPC objective function to shift the building load and to calculate hypothetical electricity costs. Results show potential 50% cost savings with respect to the existing controller with the dynamic price scenario.

Zanetti, Ettore↗

Inverse Modeling of the Initial Stage of the 1991 Pinatubo Volcanic Cloud Accounting for Radiative Feedback of Volcanic Ash

The way volcanic clouds evolve is very sensitive to the initial spatial 3D distributions of volcanic materials, which are often unknown. In this study, we conducted inverse modeling of the Mt. Pinatubo cloud using TOMS 2D mapping of Aerosol Index and SO 2 loading during the first three post-eruption days to estimate the time-dependent emissions profiles and initial 3D spatial distributions of volcanic ash and SO 2 . We account for aerosol radiative feedback and dynamic lofting of volcanic ash in the inversion calculations for the first time. This resulted in a lower ash injection height (by 1.5 km for ash) than without ash radiative feedback. The Pinatubo eruption ejected ≈77% of fine ash at 12 to 23 km, ≈65% of SO 2 at 18–25 km. In contrast with previous studies, which suggested that all volcanic materials were emitted above the tropopause, a significant fraction of SO 2 (5.1 of 15.5 Mt) and fine ash (37.2 of 66.5 Mt) were ejected in the troposphere, where SO 2 quickly oxidized into sulfate aerosol that is short-lived in the troposphere. This explains the early presence of sulfate aerosols in the plume and why the models can reproduce the observed volcanic aerosols' optical depth (AOD), assuming lower-than-observed SO 2 emission in the stratosphere. Despite the quicker than in observations build-up of sulfate AOD, in a month after the eruption, the evolution of the Pinatubo AOD simulated using the obtained ash and SO 2 initial distributions converges with the available stratospheric aerosol and gas experiment (SAGE) observations.

Pinatubo volcanic ash and SO2 emissions↗

Modeling Savings for ENERGY STAR Smart Home Energy Management Systems

The objective of this study was to develop a repeatable and defensible methodology to analyze the energy savings for Home Energy Management Systems (HEMS) that meets the minimum requirements for certification under ENERGY STAR ® Smart Home Energy Management System (SHEMS) Version 1. Mandatory connected loads include a smart thermostat, two smart lights, and one smart power strip or smart outlet. Control strategies must include feedback to occupants through an in-home display, user programming, occupancy sensor-based controls, and responsiveness to utility signals such as demand response programs. Several occupant behavior patterns were selected to quantify the range of energy savings potential for a HEMS with this basic functionality. A literature review was conducted to establish realistic room-by-room occupancy levels and usage patterns for connected devices. A series of event-driven hourly profiles were created, followed by adjustments based on application of HEMS control strategies to thermostats, interior lighting, and plug load schedules. EnergyPlus modeling was performed using these hourly schedules in three locations (Boston, Houston, and Phoenix) to examine climate dependence of energy savings. Total site energy savings ranged from 4.3 to 27.1 MBtu/year (7%-35%), and utility bill savings ranged from $\$$123 to $\$$670/year (6%-29%). The highest predicted savings was realized by occupants that were not energy conscious prior to HEMS installation, but highly engaged with the HEMS controls once the system was installed. The smart thermostat accounted for most of the savings, followed by the smart power strip. Smart lighting did not save a significant amount of energy in our analysis, based on an assumption that efficient LEDs with no standby power would normally be installed anyway.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Algorithms and Libraries

This exploratory study initiated our inquiry into algorithms and applications that would benefit by latency tolerant approach to algorithm building, including the construction of new algorithms where appropriate. In a multithreaded execution, when a processor reaches a point where remote memory access is necessary, the request is sent out on the network and a context--switch occurs to a new thread of computation. This effectively masks a long and unpredictable latency due to remote loads, thereby providing tolerance to remote access latency. We began to develop standards to profile various algorithm and application parameters, such as the degree of parallelism, granularity, precision, instruction set mix, interprocessor communication, latency etc. These tools will continue to develop and evolve as the Information Power Grid environment matures. To provide a richer context for this research, the project also focused on issues of fault-tolerance and computation migration of numerical algorithms and software. During the initial phase we tried to increase our understanding of the bottlenecks in single processor performance. Our work began by developing an approach for the automatic generation and optimization of numerical software for processors with deep memory hierarchies and pipelined functional units. Based on the results we achieved in this study we are planning to study other architectures of interest, including development of cost models, and developing code generators appropriate to these architectures.

Dongarra, Jack↗

TPSAS-NF1676L-28151-DND

The proposed suborbital mission is to collect and analyze observations to help improve our ability to model and forecast these crucial monsoonal transports and their downstream effects. The objectives are 1) to observe and relate convective-scale to meso-scale changes in the three-dimensional circulation with the efficiency of the resulting convective transports (of air mass and heat) and the build-up of the large-scale anomalies, as they are modulated by the three-dimensional structure of the aerosol loading; and 2) to observe how fluctuations in the monsoon large-scale upper-level outflow affect downstream convection, especially within AEWs. The observations will be tailor-made to help understand the controls of the northward march of the monsoon isochrones, the initiation and magnitude of heat towers over the subcontinent during the monsoon, and how the mostly zonal land-sea differential heating interacts with the meridional progress of the Intertropical Convergence Zone (ITCZ) to constrain the intensities of the northern and western outflows. Unique contributions will be made by two airborne instruments, operated in concert: NASA-LARC's Doppler Aerosol Wind Lidar (DAWN) coherent-detection wind lidar which uses a pulsed laser with a wavelength of about two microns to measure vertical profiles of the three dimensional components of the wind field, and JPL's Airborne Second Generation Precipitation Radar (APR-2) precipitation radar which measures the three-dimensional structure of rain within a swath that is about10km wide (depending on the altitude of the plane) and extends from flight level down to the surface.

Upendra N Singh↗

Modeling and Analysis of Stirling Power Convertors

Modeling and Analysis of Stirling Power Convertors Luis A. Rodriguez1 Steven M. Geng, Terry V. Reid, Scott D. Wilson NASA Glenn Research Center, Cleveland, OH, 44135, USA NASA Glenn’s Thermal Energy Conversion Branch is supporting the development of the next generation free-piston Stirling power convertors. American Superconductor (AMSC) and Sunpower Inc. are the two firms under contract to develop the Flexure Isotope Stirling Convertor (FISC) and the Sunpower Robust Stirling Convertor (SRSC), respectively. To comprehend and forecast convertor performance, Sage, ANSYS® Maxwell, and ANSYS® Fluent were used to model the Stirling thermodynamic cycle, alternator electromagnetics, and piston and displacer dynamics. I. Introduction Stirling convertors are being developed by NASA as a potential steady source of electrical power for NASA’s future scientific space missions. Currently, NASA Glenn Research Center has two corporations under contract, American Superconductor (AMSC) and Sunpower Inc., for the development of the next generation of free-piston Stirling convertors for dynamic radioisotope power systems. AMSC is developing the Flexure Isotope Stirling Convertor (FISC), which uses flexures to prevent side motion and rubbing of the piston. Similarly, Sunpower Inc, is developing the Sunpower Robust Stirling Convertor (SRSC). The SRSC uses gas bearings to prevent radial contact of the moving piston. As convertor development continues, it is increasingly important to understand and predict the interactions of components in the system, how they respond to one another, and how they perform as a response to changes in operating conditions. A suitable and enlightening way to demonstrate and foresee these interactions is with the use of accurate modeling software. Sage, ANSYS® Maxwell, and ANSYS® Fluent are the current modeling tools used by NASA to analytically determine convertor performance. Sage is a one-dimensional object-oriented commercial software package used for modeling and optimizing Stirling convertors for Dynamic Radioisotope Power Systems (DRPS) and it is one of the most accurate Stirling convertor codes in use by NASA. This code is the successor to GLIMPS (Globally-Implicit Stirling Cycle Simulation) and GLOP (GLIMPS Optimization) software created by Gedeon Associates [1]. Model input parameters are typically material/gas type, component physical dimensions, temperatures, frequency, charge pressure, and number of time/space nodes. Sage is used to model both the FISC’s and SRSC’s Stirling cycle thermodynamics and piston/displacer dynamics. Performance maps were created and analyzed for both power systems to better understand the relationship between the following conditions: cold-end temperature, hot-end temperature, piston/displacer amplitudes, pressure drop, and thermal input power. The synergy between these conditions will help determine parameter sensitivity. ANSYS® Maxwell was used to create a three-dimensional (3-D) axisymmetric model for both FISC and SRSC alternators. The significant physical components included in each model are the magnets, magnet carrier, outer/inner laminations, and the coil. Inputs to the model are piston amplitude, piston frequency, alternator load, coil resistance, tuning capacitance, and specific material properties. The alternator models calculate terminal voltage, current, piston/current phase, voltage/current phase, coil inductance, terminal power and efficiency. The RI2 losses, core (hysteresis and eddy) losses, and magnet/can eddy losses are also a part of the final results. ANSYS® Fluent is used to build 3-D computational fluid dynamic (CFD) models to examine the Stirling cycle thermodynamics for both the FISC and SRSC systems. Three-dimensional Computer Aided Design (CAD) models were used to create the physical components of each convertor. Steady-state simulations were conducted for hardware testing, prediction of environmental losses during testing, and generation of radiation look-up tables. The model inputs to the aforementioned analysis are the material properties and boundary thermal conditions. The steady-state model calculates temperature and heat flow distributions. Transient 3-D calculations were also part of the CFD analysis. In this study a physically reduced version of the FISC is used to obtain a prediction of available engine power. For the gas bearing SRSC, the transient effort is used to obtain a prediction of bearing pad performance and its sensitivity to micro-channel geometric variation. The model inputs to the transient simulations are the piston amplitude, displacer amplitude, frequency, displacer/piston phase angle, dynamic deforming CFD grid, temperature boundary conditions, and user defined files describing motion profile of piston/displacer. The results of the model are temperature distributions, heat distributions, and PV power produced at pre-determined conditions.

Luis A Rodriguez↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗

Electric Vehicles at Scale (EVs@Scale) Laboratory Consortium Deep-Dive Technical Meetings: High Power Charging (HPC) Summary Report

Electric vehicle (EV) adoption will change the composition of EV charging load to higher-power charging as more medium- (MD) and heavy-duty (HD) applications are electrified, and as all vocations, including light-duty (LD) vehicles, are capable of faster charging. These shifts provide the opportunity for high-power charging (HPC) and facility equipment to evolve and improve efficiency, cost, and space. High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project designs and develops a high-power, interoperable charging experimental platform to research, develop, and demonstrate the integration approaches and technology solutions. The project addresses (1) interconnection and management of a grid-tied inverter; (2) development of a DC distribution system that is responsible for system energy management, interoperability, and DC protection; (3) modular DC/DC conversion for vehicle charging; (4) EV charging interface and DC/DC integration; and (5) smart charge control and vehicle-to-edge (vehicle-to-building [V2B], vehicle-to-everything [V2X]) capability. This summary presentation is the first technical progress output of the project. It provides insight for the first deep-dive technical meeting outputs in terms of research presentations and also includes summary of the discussions occurred in the follow-up breakout sessions. The summary presentation covers three technical areas: (1) HPC: State of the art power architectures and the design of the power electronics, (2) Modeling, energy management, and power control in the HPC station, and (3) Next Generation Profiles for high power charging characterization.

ADVANCED PROPULSION SYSTEMS↗