Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advanced District Energy Controls for Improved Efficiency and Resilience

District energy (DE) systems have efficiently provided heat and cooling to buildings in the US for over a century by leveraging economies of scale through shared generation assets. However, optimizing DE boiler and chiller plants is complex due to the intricate mix of equipment and multiple operating flows. Sophisticated controls are necessary to achieve highest efficiencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Summary of NASA-Lewis Research Center solar heating and cooling and wind energy programs

NASA is planning to construct and operate a solar heating and cooling system in conjunction with a new office building being constructed at Langley Research Center. The technology support for this project will be provided by a solar energy program underway at NASA's Lewis Research Center. The solar program at Lewis includes: testing of solar collectors with a solar simulator, outdoor testing of collectors, property measurements of selective and nonselective coatings for solar collectors, and a solar model-systems test loop. NASA-Lewis has been assisting the National Science Foundation and now the Energy Research and Development Administration in planning and executing a national wind energy program. The areas of the wind energy program that are being conducted by Lewis include: design and operation of a 100 kW experimental wind generator, industry-designed and user-operated wind generators in the range of 50 to 3000 kW, and supporting research and technology for large wind energy systems. An overview of these activities is provided.

Vernon, R. W.↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

Solar heating and cooling system installed at Columbus, Ohio

The Solar Energy System was installed as a part of a new construction of a college building. The building will house classrooms and laboratories, administrative offices and three lecture halls. The Solar Energy System consists of 4,096 square feet (128 panels) Owens/Illinois Evacuated Glass Tube Collector Subsystem, and a 5,000 gallon steel tank below ground storage system. Hot water is circulated between the collectors and storage tank, passing through a water/lithium bromide absorption chiller to cool the building.

Source record↗

Measured performance of a 3-ton LiBr absorption water chiller and its effect on cooling system operation

A 3-ton lithium bromide absorption water chiller was tested for a number of conditions involving hot-water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It is concluded that a 3-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of thermal energy storage with electrified heating and cooling in a cold climate

Ground source heat pumps (GSHPs) have been shown to be an effective means of decarbonizing building heating and cooling, but the operation of these systems at scale presents challenges to sites and the grid due to increases in peak demand. Here, in this study, we investigate how the use of Thermal Energy Storage (TES), in the form of stratified water storage, could reduce the peak daily demand associated with GSHP systems and thus improve their cost effectiveness. This system was compared to a Combined Heat and Power (CHP) plant, to investigate the potential cost and emissions impacts of electrification on large energy users transitioning from high efficiency fossil fuel equipment. This study builds on previous research by using a significant campus area, and investigating the various impacts of an electrified system versus a state of the art fossil fuel system. An established method of TRNSYS modeling is used for the heat pumps and borehole heat exchangers (BHEs), along with the TES. The GSHP system with TES is modeled to follow industry standards and sized to provide an optimal balance of capital and operating costs. Costs were investigated for a unique large energy user rate structure, as well as for a more common generalized rate structure. The results show that the addition of TES to the GSHP system could reduce operating costs by 4.5%, but still incurs a 5.64% cost increase from the baseline CHP system. It is also shown, however, that a tactical integration of heat pumps into the CHP system is the most cost effective solution, only increasing the operating costs by 4.71%. Likewise, the impacts of different rate structures are highlighted, with the TES only resulting in 0.75% cost savings under the generalized utility rate. Furthermore, it is shown that thermal storage has great potential for demand reduction, with the addition of storage incurring a decrease of 7–22% in annual peak demand kW, dependent on the rate structure.

25 ENERGY STORAGE↗

Effective properties of semitransparent radiative cooling materials with spectrally variable properties

Radiative cooling is a promising solid-state, non-vapor-compression technology for passive refrigeration and air conditioning. Although this phenomenon occurs naturally, achieving a significant amount of cooling to make it a technically and economically viable technology requires highly engineered, spectrally selective radiative surfaces. These characteristics make radiative cooling difficult to estimate, particularly when it is integrated with other systems such as photovoltaic panels or building envelopes. The complexity further increases when the substrate also participates in the radiative cooling (along with the radiative coating). Energy estimation is becoming increasingly critical because of the recent focus on the semitransparent radiative coatings that transmit a variety of colors to enhance the aesthetic appeal of the system. In this work, we propose an iterative method to calculate the effective radiative properties, which provides the same net radiative cooling that would be observed using the spectral properties at both the coating and substrate surfaces. Compared to traditional methods that rely on either computationally expensive full spectral analysis or methods for averaging each radiative surface parameter locally, our proposed method focuses on calculating effective properties that provide the same the net cooling effect as a full spectral analysis by accounting the emissivity, absorptivity, and transmissivity collectively, thereby providing an overall estimation error of less than 0.2%. We believe that this study will be beneficial to the engineering communities that employ complex simulation codes and require lumped solar and thermal radiation related parameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured performance of a 3 ton LiBr absorption water chiller and its effect on cooling system operation

A three ton lithium bromide absorption water chiller was tested for a number of conditions involving hot water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It was concluded that a three-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Layered Thermal Insulation Systems for Industrial and Commercial Applications

From the high performance arena of cryogenic equipment, several different layered thermal insulation systems have been developed for industrial and commercial applications. In addition to the proven areas in cold-work applications for piping and tanks, the new Layered Composite Insulation for Extreme Environments (LCX) has potential for broader industrial use as well as for commercial applications. The LCX technology provides a unique combination of thermal, mechanical, and weathering performance capability that is both cost-effective and enabling. Industry applications may include, for example, liquid nitrogen (LN2) systems for food processing, liquefied natural gas (LNG) systems for transportation or power, and chilled water cooling facilities. Example commercial applications may include commercial residential building construction, hot water piping, HVAC systems, refrigerated trucks, cold chain shipping containers, and a various consumer products. The LCX system is highly tailorable to the end-use application and can be pre-fabricated or field assembled as needed. Product forms of LCX include rigid sheets, semi-flexible sheets, cylindrical clam-shells, removable covers, or flexible strips for wrapping. With increasing system control and reliability requirements as well as demands for higher energy efficiencies, thermal insulation in harsh environments is a growing challenge. The LCX technology grew out of solving problems in the insulation of mechanically complex cryogenic systems that must operate in outdoor, humid conditions. Insulation for cold work includes equipment for everything from liquid helium to chilled water. And in the middle are systems for LNG, LN2, liquid oxygen (LO2), liquid hydrogen (LH2) that must operate in the ambient environment. Different LCX systems have been demonstrated for sub-ambient conditions but are capable of moderately high temperature applications as well.

thermal conductivity↗

An HPC-Based Hydrothermal Finite Element Simulator for Modeling Underground Response to Community-Scale Geothermal Energy Production

Geothermal heat, as renewable energy, shows great advantage with respect to its environmental impact due to its significantly lower CO2 emissions than conventional fossil fuel. Open and closed-loop geothermal heat pumps, which utilize shallow geothermal systems, are an efficient technology for cooling and heating buildings, especially in urban areas. Integrated use of geothermal energy technologies for district heating, cooling, and thermal energy storage can be applied to optimize the subsurface for communities to provide them with multiple sustainable energy and community resilience benefits. The utilization of the subsurface resources may lead to a variation in the underground environment, which might further impact local environmental conditions. However, very few simulators can handle such a highly complex set of coupled computations on a regional or city scale. We have developed high-performance computing (HPC) based hydrothermal finite element (FE) simulator that can simulate the subsurface and its hydrothermal conditions at a scale of tens of km. The HPC simulator enables us to investigate the subsurface thermal and hydrologic response to the built underground environment (such as basements and subways) at the community scale. In this study, a coupled hydrothermal simulator is developed based on the open-source finite element library deal.II. The HPC simulator was validated by comparing the results of a benchmark case study against COMSOL Multiphysics, in which Aquifer Thermal Energy Storage (ATES) is modeled and a process of heat injection into ATES is simulated. The use of an energy pile system at the Treasure Island redevelopment site (San Francisco, CA, USA) was selected as a case study to demonstrate the HPC capability of the developed simulator. The simulator is capable of modeling multiple city-scale geothermal scenarios in a reasonable amount of time.

Sun, Xiang↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar heating, cooling and domestic hot water system installed at Columbia Gas System Service Corporation, Columbus, Ohio

The solar energy system installed in the building has 2,978 sq ft of single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/hour water tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts from the site files, specification references, drawings, installation, operation and maintenance instructions are included.

Source record↗

HVAC System Performance for Energy Codes (Technical Brief)

The prescriptive path is likely the most widely used approach for commercial code compliance in the United States. Though easy to implement, the prescriptive approach does not discriminate between high-performing and poorly performing heating, ventilation, air conditioning (HVAC) system configurations that are both minimally compliant. To meet aggressive energy and carbon reduction goals, energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. HVAC System Performance is a discipline performance path and provides a simpler solution to HVAC system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution that could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A web-based calculation tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach has also been evaluated by the ASHRAE Standard 90.1 Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Total System Performance Ratio—A Systems Based Approach for Evaluating HVAC System Efficiency

The prescriptive path is the most widely used approach for commercial code compliance in the United States. Though easy to implement, prescriptive approaches do not typically discriminate between minimally compliant, high-performing and poorly performing HVAC system configurations. Hence, to meet aggressive energy and carbon reduction goals, it is clear that energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. This paper discusses a new HVAC system-based performance approach (HVAC System Performance) which provides a simpler solution to HVAV system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution which could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A calculation software tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach is also being evaluated by ASHRAE Standard 90.l Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of solar energy; Proceedings of the Third Southeastern Conference, Huntsville, Ala., April 17-19, 1978

Demonstration projects, systems-subsystems simulation programs, applications (heating, cooling, agricultural, industrial), and climatic data testing (standards, economics, institutional) are the topics of the book. Economics of preheating water for commercial use and collecting, processing, and dissemination of data for the national demonstration program are discussed. Computer simulation of a solar energy system and graphical representation of solar collector performance are considered. Attention is given to solar driven heat pumps, solar cooling equipment, hybrid passive/active solar systems, and solar farm buildings. Evaluation of a thermographic scanning device for solar energy and conservation applications, use of meteorological data in system evaluation, and biomass conversion potential are presented.

Wu, S. T.↗