Elemental profiling and genome-wide association studies reveal genomic variants modulating ionomic composition in Populus trichocarpa leaves

The ionome represents elemental composition in plant tissues and can be an indicator of nutrient status as well as overall plant performance. Thus, identifying genetic determinants governing elemental uptake and storage is an important goal for breeding and engineering biomass feedstocks with improved performance. In this study, we coupled high-throughput ionome characterization of leaf tissues with high-resolution genome-wide association studies (GWAS) to uncover genetic loci that modulate ionomic composition in leaves of poplar ( Populus trichocarpa ). Significant agreement was observed across the three ionomic profiling platforms tested: inductively coupled plasma-mass spectrometry (ICP-MS), neutron activation analysis (NAA) and laser-induced breakdown spectroscopy (LIBS). Relative quantification of 20 elements using ICP-MS across a population of 584 genotypes, revealed larger variation in micro-nutrients and trace elements content than for macro-nutrients across genotypes. The GWAS performed using a set of high-density (>8.2 million) single nucleotide polymorphisms, identified over 600 loci significantly associated with variations in these mineral elements, pointing to numerous uncharacterized candidate genes. A significant enrichment for genes related to ion homeostasis and transport was observed, including several members of the cation-proton antiporters (CPA) family and MATE efflux transporters, previously reported to be critical for plant growth and fitness in other species. Our results also included a polymorphic copy of the high-affinity molybdenum transporter MOT1 found directly associated to molybdenum content. For the first time in a perennial plant, our results provide evidence of genetic control of mineral content in a model tree species.

59 BASIC BIOLOGICAL SCIENCES↗

Spectral emission characteristics near 646 nm and plasma properties of laser-induced plasma of gaseous uranium hexafluoride

We present a detailed investigation of the temporal evolution of line and continuum emissions in laser-induced breakdown spectroscopy (LIBS) of gaseous uranium hexafluoride (UF 6 ), focusing on the spectral region near 646 nm. Spectral emission features, signal-to-background ratios (SBRs) of selected uranium lines, and spectral linewidths were examined under varying UF 6 pressures (15–60 Torr) and laser pulse energies (10–60 mJ). Higher pressures and pulse energies enhanced continuum emission and reduced SBRs but did not cause significant spectral congestion. Additional studies with the use of different laser systems, including nanosecond-pulsed Nd:YAG lasers (at fundamental and various harmonics) and a femtosecond-pulsed Ti:sapphire laser, revealed long-lived plasma continua in all cases. This persistent continuum is attributed to a pseudo-continuum from overlapping molecular emissions, as its intensity scales linearly with electron number density, deviating from the expected quadratic dependence of classical ion–electron interactions for free-free and free-bound continuum emission. Based on plasma persistence time, SBR, U II/U I intensity ratios, and electronic excitation temperature, no fundamental advantage was found for femtosecond-pulsed lasers over conventional nanosecond-pulsed ones for UF 6 enrichment assay with direct LIBS measurement.

Laser-induced breakdown spectroscopy↗

Rare Earth Element Detection and Quantification in Coal and Rock Mineral Matrices

As global demand for rare earth elements (REEs) increases, maintaining the production and supply chain is critical. Technologies capable of being used in the field and in situ in the subsurface for rapid REE detection and quantification facilitates the efficient mining of known resources and exploration of new and unconventional resources. Laser-induced breakdown spectroscopy (LIBS) is a promising technique for rapid elemental analysis both in the laboratory and in the field. Multiple articles have been published evaluating LIBS for detection and quantification of REEs; however, REEs in their natural deposits have not been adequately studied. In this work, detection and quantification of two REEs, La and Nd, have been studied in both synthetic and natural mineral matrices at concentrations relevant to REE extraction. Measurements were performed on REE-containing rock and coal samples (natural and synthetic) utilizing different LIBS instruments and techniques, specifically a commercial benchtop instrument, a custom benchtop instrument (single- and double-pulse modes), and a custom LIBS probe currently being developed for in situ, subsurface, borehole wall detection and quantification of REEs. Plasma expansion, emission intensity, detection limits, and double-pulse signal enhancement were studied. The limits of detection (LOD) were found to be 10/14 ppm for La and 15/25 ppm for Nd in simulated coal/rock matrices in single-pulse mode. Signal enhancement of 3.5 to 6-fold was obtained with double-pulse mode as compared to single-pulse operation.

La detection↗

An initial exploration of Bayesian model calibration for estimating the composition of rocks and soils on Mars

The Mars Curiosity rover carries an instrument, ChemCam, designed to measure the composition of surface rocks and soil using laser-induced breakdown spectroscopy (LIBS). The measured spectra from this instrument must be analyzed to identify the component elements in the target sample, as well as their relative proportions. This process, which we call disaggregation, is complicated by so-called matrix effects, which describe nonlinear changes in the relative heights of emission lines as an unknown function of composition due to atomic interactions within the LIBS plasma. In this work, we explore the use of the plasma physics code ATOMIC, developed at Los Alamos National Laboratory, for the disaggregation task. ATOMIC has recently been used to model LIBS spectra and can robustly reproduce matrix effects from first principles. The ability of ATOMIC to predict LIBS spectra presents an exciting opportunity to perform disaggregation in a manner not yet tried in the LIBS community, namely via Bayesian model calibration. However, using it directly to solve our inverse problem is computationally intractable due to the large parameter space and the computation time required to produce a single output. Therefore, we also explore the use of emulators as a fast solution for this analysis. We discuss a proof of concept Gaussian process emulator for disaggregating two-element compounds of sodium and copper. The training and test datasets were simulated with ATOMIC using a Latin hypercube design. After testing the performance of the emulator, we successfully recover the composition of 25 test spectra with Bayesian model calibration.

97 MATHEMATICS AND COMPUTING↗

Exploration of LIBS as a novel and rapid elemental mapping technique of nuclear fuels in the form of surrogate TRISO particles

Laser-induced breakdown spectroscopy (LIBS) was employed to characterize coatings on surrogate fuel particles. Tri-structural isotropic (TRISO) particles are a proposed nuclear fuel alternative for high temperature reactors. These particles are constructed of a ZrO 2 kernel (as a surrogate to uranium), surrounded by an inner pyrolytic carbon layer and are surrounded by an outer carbide layer (ZrC, presented here) to act as a barrier to fission products generated during nuclear reactions. These particles are embedded within a graphite compact and housed within the reactor core. Simply put, due to their robust nature, performing elemental analysis of these particles poses a challenge. Presented here, LIBS is explored as a method for characterizing elemental constituents of these particles, with the focus being on rapid elemental mapping and depth profiling. Different from traditional elemental analysis techniques (e.g., inductively coupled plasma – based methods), LIBS is advantageous because it can directly analyze the sample surface and can detect light elements such as C and O, making it a viable technique for the analysis of small, multilayered particles as spatial elemental information is warranted in the production of these particles. In the work presented here, LIBS was successfully used for discerning small layers (30–50 μm), detecting the location of carbon and oxygen layers, providing fast 2-D mapping (<5 min per particle) and rapid depth profiling (10 s per particle).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantification of manganese for ChemCam Mars and laboratory spectra using a multivariate model

In this work, we report a new calibration model for manganese using the laser-induced breakdown spectroscopy instrument that is part of the ChemCam instrument suite onboard the NASA Curiosity rover. The model has been trained using an expanded set of 523 manganese-bearing rock, mineral, metal ore, and synthetic standards. The optimal calibration model uses the Partial Least Squares (PLS) and Least Absolute Shrinkage and Selection Operator (LASSO) multivariate techniques, with a novel “double blending” technique. We determined the detection limit for manganese is 82 ppm using a method blank procedure and is possibly as low as 27 ppm based on visual inspection of the spectra. Based on a representative test set consisting of measurements on 93 standards, the double blended multivariate model shows a Root Mean Squared Error of Prediction (RMSEP) accuracy of 1.39 wt% MnO for the full blended model. Employing a local RMSEP estimate where the model performance is evaluated based on nearby test samples, the accuracy is 0.03 wt% at the quantification limit (0.05 wt% MnO), 0.4 wt% accuracy at 1.0 wt% MnO, and 4.4 wt% accuracy at 100 wt% MnO. Precision is estimated using the standard deviation of the test set measurements, and is ±0.01 wt% MnO at the quantification limit, ±0.09 wt% MnO at 1.0 wt% MnO, and ± 2.1 wt% MnO at 100 wt% MnO (all 1 standard deviation). This new calibration is important for understanding the variation of manganese in the bedrock with the Curiosity rover on Mars, which provides insight into past redox conditions on Mars.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemistry imaging and distribution analysis of rare earth elements in coal using LIBS and LA-ICP-MS instruments

Currently, demand for rare earth elements (REEs) increased significantly. Coal is actively evaluated as potential economic sources for extraction of REEs. Here, in this work, laser-induced breakdown spectroscopy (LIBS) was evaluated for rapid estimation of REEs content and their distribution in the natural coal samples. The results were compared with similar laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) measurements. Thirteen coal samples (nine standard samples and five natural samples) were used in this study. Powder samples were pressed into pellets while coal chunks were directly ablated for data recording. Pellets of the powder standard samples were used to optimize the data acquisition system and then data recorded with this optimized system was used to identify the proper data acquisition and analysis models. After establishing the proper data acquisition system and analysis model using the standard samples, natural coal samples in powder form and their chunks were utilized to record LIBS and LA-ICP-MS spectra. Multivariate calibration models were developed using four of the natural samples, which were evaluated by predicting the REE content in the fifth sample. Principal component analysis was performed on the LIBS data obtained from the natural samples and it classified all the samples with high accuracy. Two-dimensional (2D) elemental mapping on coal chunk samples was also performed using both LIBS and LA-ICP-MS to study the distribution of REEs in the samples. The resulting elemental images and their correlations can be used to infer mineral distributions.

01 COAL, LIGNITE, AND PEAT↗

Exploration of a Combined LIBS and LA-ICP-MS Approach for Apatite Characterisation

A combined laser‐induced breakdown spectroscopy (LIBS) and laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) method is demonstrated for comprehensive apatite analysis. These measurements provide elemental imaging that can be used as a screening technique for chemical selection of grains for subsequent analysis (e.g., U‐Pb geochronology) or can be used to understand elemental distributions within a single grain that would have direct textural‐chemical implications (e.g., zoning patterns). Adding LIBS as a simultaneous measurement, to LA‐ICP‐MS U‐Pb geochronology, allowed for the direct determination of F (H and O show promise for future applications) in addition to major and trace elements of interest. Here, the quantitative measurements were validated against a series of apatites with known values and used to characterise a wide range of samples. Fluorine detection limits were determined to be as low as 70 μg g ‐1 F (broadband CMOS detector) and 4.2 μg g ‐1 F (ICCD detector). U‐Pb age dating was simultaneously collected by LA‐ICP‐MS with the quantitative elemental data from LIBS, providing a comprehensive method for geochronology.

Apatite↗

Optimizing aluminum oxide passivation layers—Laser-induced plasmas for layer formation, real-time diagnostics, and layer evaluation

Molten salts have beneficial thermophysical and electrolytic properties, but the aggressive nature of molten salts requires corrosion mitigation strategies, such as structural material surface treatment. In this study, a laser-induced breakdown spectroscopy (LIBS) system was used to simultaneously ablate and monitor de-excitation spectra to form and identify dense alumina passivation layers. Additionally, high-frequency (kHz) LIBS imaging allowed rapid elemental mapping and depth profiling for surface O/Al ratios via minimally destructive analysis. The paired t-test rejected the null hypothesis that air and Ar cover gases were equivalent (p = 0.00012), and the analysis of variance (ANOVA) showed that overlap between shots (p = 0.03112) and cover gas flow rate (p = 0.02729) were statistically significant. At 75% overlap, the O/Al ratio increased to 10% ± 2%, and 90% overlap rose further to 31% ± 2%. Regardless of overlap, tuning the gas flow from 0.5 to 2.5 L min −1 enhanced the O/Al ratio by 24% ± 4%. LIBS depth profiling showed a 3× increase in layer thickness from 75% to 90% overlap. Molecular band peaks of AlO, a precursor to Al 2 O 3 found during treatment, suggest that band intensity could be used for real-time Al 2 O 3 optimization. Ultimately, by adjusting laser spot overlap and cover gas flow rate, a 266 nm laser was shown to form Al 2 O 3 layers on an Al6061 sample, with cover gas flow rate primarily affecting the O/Al ratio and layer thickness correlating with laser spot overlap. This combination of molecular spectra collection, imaging, and depth profiling demonstrated the robust layer analysis capabilities of LIBS.

Corrosion↗

Implementation of stacked ensemble machine learning for the detection of surrogate plutonium contamination in soil via LIBS

Supervised machine learning methods have demonstrated increased utility for the quantification of lanthanide and actinide elements in atomic spectroscopy applications. This study implements laser-induced breakdown spectroscopy (LIBS) for the identification of plutonium surrogate material (CeO 2 ) in soil matrices by training supervised machine learning methods on the recorded spectral data. A bagged ensemble using Random Forest yields the highest sensitivity predictions with a detection limit of 0.015 wt.% CeO 2 . However, high precision in Ce content prediction required the use of a stacked ensemble regression, which provided the superlative Ce quantification model with an error of 0.107% and a detection limit of 0.022 wt.%. Furthermore, the high performance of the stacked ensemble demonstrates its potential to enhance the accuracy and sensitivity of nuclear contaminant detection using field-deployable spectroscopic analyzers in real-world scenarios.

47 OTHER INSTRUMENTATION↗

Towards the development of resonantly enhanced laser-based diagnostics for molten salt reactor safeguards

The adoption of Generation IV molten salt reactors (MSRs) depends on the ability to implement compatible monitoring instrumentation to ensure adherence to nuclear safeguards. This task is nontrivial due to the high temperature, reactive, and chemically complex fuel and coolant components contained within these systems. Optical spectroscopy techniques such as laser-induced fluorescence (LIF) and laser-induced breakdown spectroscopy (LIBS) are candidates for monitoring instrumentation. They offer many advantages for continuous monitoring, including the ability to operate at a standoff and compatibility with liquid-phase analytes. We discuss the use of LIF for the detection of Nd, a common fission fragment, within a liquid matrix. Results show that for NdCl3 dissolved in water, the Nd I 492.45 nm resonant transition is detectable without the need to induce a plasma and that the fluorescence emission can be separated in the time domain from the laser scatter signal. Additionally, we present a setup and preliminary results for measurements of solid Nd and U using resonant LIBS. The results demonstrate element-selective measurement capabilities and provide the foundational data necessary to continue the development of laser-based MSR diagnostics. This work also helps address gaps in the literature regarding energy level assignments of Nd.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

SULI Report - Development of a Molten Salt Circulation Loop for in-situ Spectroscopy

This project supports the development of real time optical monitoring capabilities for molten salt reactor (MSR) environments by designing, testing, and refining a molten salt circulation loop suitable for combined laser induced breakdown spectroscopy (LIBS) and ultraviolet visible (UV Vis) absorption measurements. Online spectroscopic monitoring is increasingly important for nuclear safeguards, corrosion tracking, and material accountancy, yet MSR process fluids present substantial challenges due to their chemical complexity and hazards such as high temperatures and radiation. To address these needs, this work focuses on Phase I, the development of a room temperature aqueous circulation loop that serves as a surrogate platform for evaluating flow behavior, optical access, and component performance prior to high temperature salt operation. Initial testing identified several practical issues—including leaks, obstructions, and two-phase flow through the absorption cell—that were systematically resolved through hardware replacement, flow path redesign, and venturi pressure optimization. Relocating the flow cell upstream of the primary venturi enabled periods of stable single-phase flow, demonstrating the feasibility of integrating optical diagnostics into a circulation system. The results of Phase I provide essential design insight for Phase II, which will incorporate furnace compatible materials and LiCl KCl eutectic salt. Completion of the molten salt system will deliver a reusable testbed for evaluating multimodal spectroscopic techniques, advancing nondestructive, real time monitoring tools for future MSR and nuclear fuel cycle applications.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Machine learning in analytical spectroscopy for nuclear diagnostics [Invited]

Analytical spectroscopy methods have shown many possible uses for nuclear material diagnostics and measurements in recent studies. In particular, the application potential for various atomic spectroscopy techniques is uniquely diverse and generates interest across a wide range of nuclear science areas. Over the last decade, techniques such as laser-induced breakdown spectroscopy, Raman spectroscopy, and x-ray fluorescence spectroscopy have yielded considerable improvements in the diagnostic analysis of nuclear materials, especially with machine learning implementations. These techniques have been applied for analytical solutions to problems concerning nuclear forensics, nuclear fuel manufacturing, nuclear fuel quality control, and general diagnostic analysis of nuclear materials. The data yielded from atomic spectroscopy methods provide innovative solutions to problems surrounding the characterization of nuclear materials, particularly for compounds with complex chemistry. Implementing these optical spectroscopy techniques can provide comprehensive new insights into the chemical analysis of nuclear materials. In particular, recent advances coupling machine learning methods to the processing of atomic emission spectra have yielded novel, robust solutions for nuclear material characterization. This review paper will provide a summation of several of these recent advances and will discuss key experimental studies that have advanced the use of analytical atomic spectroscopy techniques as active tools for nuclear diagnostic measurements.

Rao, Ashwin P. (ORCID:0000000319312568)↗

Toward improved PVDF-BaTiO 3 composite dielectrics: mechanical activation of the filler versus filler content

Abstract Barium titanate (BT) perovskite particles were surface modified by means of mechanical treatment and used as inorganic component in polyvinylidene fluoride (PVDF) based composites. The changes in electrical properties of the composite films with increasing in filler content were followed by dielectric spectroscopy, breakdown strength andD-Emeasurements. A comparison of the properties of the composites prepared with untreated and mechanically activated particles revealed that there is a significant difference in their performances at low filler concentrations (<20 wt%). Introduction of the surface modified ceramic particles into PVDF matrix led to an increase of the dielectric constant without affecting significantly the electrical breakdown strength. In contrast, when as received BT particles were used a filler, both dielectric constants and breakdown strengths of the composite films were lower than the corresponding values observed for the pure PVDF. At higher concentrations, however, the influence of pre-treatment of the filler on the effective electrical properties becomes less significant. The obtained results were discussed in terms of the pronounced crystallization of polarβandγcrystal phases of PVDF in the presence of surface modified BT fillers, which is confirmed by Raman spectroscopy.

Physics↗

A Molten Salt Aerosol Spectroscopy Approach to Online Process Monitoring in Molten Salt Reactors

Recent research and development in molten salt reactors (MSRs) has led to many advanced reactor designs, many of which have demonstrations planned in the next decade. However, a significant challenge that must be overcome before liquid fueled MSRs become viable globally is nuclear material accountancy (NMA) and safeguards. Liquid-fueled MSRs are problematic to safeguards because the nuclear material is in the bulk phase, inventories are constantly changing, and there are potentially many outlet pathways that must be monitored, especially in designs with online chemical processing. At the Idaho National Laboratory, we have developed a process monitoring tool to circulate molten salt through a nebulizer and optical cell, where laser-induced breakdown spectroscopy (LIBS) and ultraviolet-visible (UV-VIS) are applied to track the elemental and oxidation states of the constituents in the salt aerosol. This approach has the potential to provide information on the actinides, fission products, and corrosion in the reactor or process. Preliminary testing in aqueous praseodymium chloride (PrCl3) and neodymium chloride (NdCl3) showed good sensitivity detection limits n developed calibration curves. Additional tests and analysis or ongoing in aqueous solutions while equipment is being scaled up for high temperature molten salt testing. Results for continued testing as well as a status of the molten salt design and anticipated commissioning will be presented.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A case study on the use of carbon sticky tabs for microbeam uranium isotope measurement with an emphasis on understanding the influence of subtle variations in substrate composition

In this paper we integrate laser induced breakdown spectroscopy (LIBS), large geometry secondary ion mass spectrometry (LG-SIMS), laser ablation—multi collector—inductively coupled plasma—mass spectrometry (LA-MC-ICP-MS), and trace elemental compositions obtained by bulk digestion from a suite of commercially available carbon sticky tabs to determine if subtle variations in the tab’s composition can be tied to shifts in the observed uranium isotopic composition of the IRMM-2020 standard relative to its ‘true’ value. The results suggest that, although clear differences exist in the relative abundances of carbon and hydrogen across the various carbon sticky tabs examined, as well as differences in their trace elemental and total uranium concentrations, these differences do not appear to influence the LG-SIMS or LA-MC-ICP-MS uranium isotope ratio measurements, or the appearance of the uranium mass spectrum scans. Instead, the quality (i.e., precision and accuracy) of the LG-SIMS and LA-MC-ICP-MS results are directly proportional to the observed signal intensity at the time of analysis. For the LG-SIMS measurements, there does appear to be a direct correlation between 235U1H hydride formation rates and vacuum conditions within the instrument’s analytical chamber. Furthermore, none of the carbon sticky tabs examined by LG-SIMS displayed evidence of elevated background uranium content. While a preliminary correlation was observed between the uranium isotope background signal during LA-MC-ICP-MS and the total uranium concentrations determined by isotope dilution, none of the tabs displayed a high enough analytical background to affect the isotope ratio measurements.

Zirakparvar, Alex [ORNL] (ORCID:0000000337797730)↗

Laser-Induced Plasma as a Method for the Metallic Materials Hardness Estimation: An Alternative Approach

The application of an alternative laser-induced breakdown spectroscopy (LIBS) method based on transversely excited atmospheric (TEA) CO2 laser was investigated for the first time for estimating the hardness of metallic materials. The human eye-safe (TEA) CO2 laser, operating at 10.6 µm, was used for plasma generation. The LIBS spectra were recorded by employing a cost-effective CCD camera for the time-integrated and spatial resolved measurements. The cast iron and aluminum alloys samples with different hardness have been tested. The ratio between the magnesium ionic and neutral lines in LIBS spectra was applied for estimating the material hardness. In addition, the hardness of all samples included in this study was determined using the conventional method for material hardness determination, i.e. Vickers hardness test. The linear dependence of magnesium lines intensity ratio on the sample’s hardness was obtained for both kinds of materials. Profilometric measurements were used to verify that the newly-introduced method is almost nondestructive for the investigated metals. The results obtained in the present work confirmed the potential of using this original LIBS system not only for the fast elemental analysis but also for the direct estimation of the hardness of metals and alloys. © 2020, Springer Science+Business Media, LLC, part of Springer Nature.

36 MATERIALS SCIENCE↗

SuperCam Calibration Targets: Design and Development

Abstract SuperCam is a highly integrated remote-sensing instrumental suite for NASA’s Mars 2020 mission. It consists of a co-aligned combination of Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), Visible and Infrared Spectroscopy (VISIR), together with sound recording (MIC) and high-magnification imaging techniques (RMI). They provide information on the mineralogy, geochemistry and mineral context around the Perseverance Rover. The calibration of this complex suite is a major challenge. Not only does each technique require its own standards or references, their combination also introduces new requirements to obtain optimal scientific output. Elemental composition, molecular vibrational features, fluorescence, morphology and texture provide a full picture of the sample with spectral information that needs to be co-aligned, correlated, and individually calibrated. The resulting hardware includes different kinds of targets, each one covering different needs of the instrument. Standards for imaging calibration, geological samples for mineral identification and chemometric calculations or spectral references to calibrate and evaluate the health of the instrument, are all included in the SuperCam Calibration Target (SCCT). The system also includes a specifically designed assembly in which the samples are mounted. This hardware allows the targets to survive the harsh environmental conditions of the launch, cruise, landing and operation on Mars during the whole mission. Here we summarize the design, development, integration, verification and functional testing of the SCCT. This work includes some key results obtained to verify the scientific outcome of the SuperCam system.