Lensing bias to CMB polarization measurements of compensated isocurvature perturbations
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided
Abstract not provided.
No abstract available
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Computer simulations are performed for an argon inductively coupled plasma (ICP) with a capacitive radio-frequency bias power, to investigate the bias effect on the discharge mode transition and on the plasma characteristics at various ICP currents, bias voltages, and bias frequencies. When the bias frequency is fixed at 13.56 MHz and the ICP current is low, e.g., 6 A, the spatiotemporal averaged plasma density increases monotonically with bias voltage, and the bias effect is already prominent at a bias voltage of 90 V. The maximum of the ionization rate moves toward the bottom electrode, which indicates clearly the discharge mode transition in inductive/capacitive discharges. At higher ICP currents, i.e., 11 and 13 A, the plasma density decreases first and then increases with bias voltage, due to the competing mechanisms between the ion acceleration power dissipation and the capacitive power deposition. At 11 A, the bias effect is still important, but it is noticeable only at higher bias voltages. At 13 A, the ionization rate is characterized by a maximum at the reactor center near the dielectric window at all selected bias voltages, which indicates that the ICP power, instead of the bias power, plays a dominant role under this condition, and no mode transition is observed. Indeed, the ratio of the bias power to the total power is lower than 0.4 over a wide range of bias voltages, i.e., 0–300 V. Besides the effect of ICP current, also the effect of various bias frequencies is investigated. It is found that the modulation of the bias power to the spatiotemporal distributions of the ionization rate at 2 MHz is strikingly different from the behavior observed at higher bias frequencies. Furthermore, the minimum of the plasma density appears at different bias voltages, i.e., 120 V at 2 MHz and 90 V at 27.12 MHz.
On large scales a nonlinear transformation of matter density field can be viewed as a biased tracer of the density field itself. A nonlinear transformation also modifies the redshift space distortions in the same limit, giving rise to a velocity bias. In models with primordial nongaussianity a nonlinear transformation generates a scale dependent bias on large scales. We derive analytic expressions for the large scale bias, the velocity bias and the redshift space distortion (RSD) parameter β, as well as the scale dependent bias from primordial nongaussianity for a general nonlinear transformation. These biases can be expressed entirely in terms of the one point distribution function (PDF) of the final field and the parameters of the transformation. The analysis shows that one can view the large scale bias different from unity and primordial nongaussianity bias as a consequence of converting higher order correlations in density into 2-point correlations of its nonlinear transform. Our analysis allows one to devise nonlinear transformations with nearly arbitrary bias properties, which can be used to increase the signal in the large scale clustering limit. We apply the results to the ionizing equilibrium model of Lyman-α forest, in which Lyman-α flux F is related to the density perturbation δ via a nonlinear transformation. Velocity bias can be expressed as an average over the Lyman-α flux PDF. At z = 2.4 we predict the velocity bias of -0.1, compared to the observed value of −0.13±0.03. Bias and primordial nongaussianity bias depend on the parameters of the transformation. Measurements of bias can thus be used to constrain these parameters, and for reasonable values of the ionizing background intensity we can match the predictions to observations. Matching to the observed values we predict the ratio of primordial nongaussianity bias to bias to have the opposite sign and lower magnitude than the corresponding values for the highly biased galaxies, but this depends on the model parameters and can also vanish or change the sign.
Linear plasma devices (LPDs) are important experimental platforms for investigating plasma–material interactions (PMI). In PMI experiments, it has been found that applying a target bias not only effectively modifies the incident ion energy, but also induces significant changes in the electron density and electron temperature, whereby the evolution of these plasma parameters is primarily governed by plasma transport processes. However, at present, the physical process and mechanism underlying such bias-induced variations remain unclear. In this work, biasing experiments under argon plasma discharge conditions were first carried out on the MPS-LD device. For the corresponding experiments, an electric potential model was newly developed based on the BOUT++ LPD module, enabling self-consistent simulations of plasma transport under biased conditions. Numerical simulations were then performed to reproduce the experimental results and to validate the accuracy of the proposed model. Finally, by combining experimental measurements with numerical simulations, a bias-voltage scan was performed to investigate how the electron density and electron temperature vary with the bias voltage (U bias ). The results show that applying negative bias decreases the target electron density (n e,T ) while increasing the target electron temperature (T e,T ). In contrast, positive bias increases both n e,T and T e,T ; however, at high positive bias, n e,T first reaches a maximum and subsequently decreases with further increases in U bias . The underlying physical mechanisms are analyzed using particle flux, momentum, and energy conservation. It indicates that the applied bias regulates the parallel electric field, thereby changing ion and electron velocities, and consequently affecting the electron density. At high positive bias, the ion velocity is further influenced by ion viscosity, leading to the reversal in n e,T . Meanwhile, the enhanced parallel electric field drives stronger currents, significantly increasing ion–electron frictional work and converting the input bias power into electron energy, which raises the electron temperature. In conclusion, these results contribute to a deeper understanding of the effects and mechanisms of biasing on plasma transport in the MPS-LD device.
New TSUNAMI tools of SCALE 6, TSURFER and TSAR, are demonstrated to examine the bias effects of small-worth test materials, relative to reference experiments. TSURFER is a data adjustment bias and bias uncertainty assessment tool, and TSAR computes the sensitivity of the change in reactivity between two systems to the cross-section data common to their calculation. With TSURFER, it is possible to examine biases and bias uncertainties in fine detail. For replacement experiments, the application of TSAR to TSUNAMI-3D sensitivity data for pairs of experiments allows the isolation of sources of bias that could otherwise be obscured by materials with more worth in an individual experiment. The application of TSUNAMI techniques in the design of nine reference experiments for the MIRTE program will allow application of these advanced techniques to data acquired in the experimental series. The validation of all materials in a complex criticality safety application likely requires consolidating information from many different critical experiments. For certain materials, such as structural materials or fission products, only a limited number of critical experiments are available, and the fuel and moderator compositions of the experiments may differ significantly from those of the application. In these cases, it is desirable to extract the computational bias of a specific material from an integral keff measurement and use that information to quantify the bias due to the use of the same material in the application system. Traditional parametric and nonparametric methods are likely to prove poorly suited for such a consolidation of specific data components from a diverse set of experiments. An alternative choice for consolidating specific data from numerous sources is a data adjustment tool, like the ORNL tool TSURFER (Tool for Sensitivity/Uncertainty analysis of Response Functionals using Experimental Results) from SCALE 6.1 However, even with TSURFER, it may be difficult to examine a single experiment and differentiate bias due to a test material from bias due to other materials such as fuel and moderator. An alternative method is to perform two experiments on the same critical assembly, one with and one without the test material, and examine differences in the biases due to the introduction of the test material. Techniques to extract a computational bias from pairs of replacement experiments and project that bias, with an associated bias uncertainty, to an application system are described herein.
A low bias in carbon monoxide compared to observations at high latitudes is a common feature of chemistry climate models. CO bias can both indicate and contribute to a bias in modeled OH and methane lifetime. This study examines possible causes of CO bias in the ACCMIP simulation of the GEOSCCM, and considers how attributing the CO bias to uncertainty in CO emissions versus biases in other constituents impacts the relationship between CO bias and methane lifetime. We use a simplified model of CO tagged by source with specified OH to quantify the sensitivity of the CO bias to changes in CO emissions or OH concentration, comparing the modeled CO to surface and MOPITT observations. The simplified model shows that decreasing OH in the northern hemisphere removes most of the global mean and inter-hemispheric bias in surface CO. We then use results from this analysis to explore how adjusting CO sources in the CCM impacts the concentrations of ozone, OH and methane. The CCM simulation also exhibits biases in ozone and water vapor compared to observations. We use a parameterized CO-OH-CH4 model that takes ozone and water vapor as inputs to the parameterization to examine whether correcting water and ozone biases can alter OH enough to remove the CO bias. Through this analysis, we aim to better quantify the relationship between CO bias and model biases in ozone concentrations and methane lifetime.
Shortwave irradiance biases due to two- and four-stream approximations have been studied for the last couple of decades, but biases in estimating Earth’s radiation budget have not been examined in earlier studies. In order to quantify biases in diurnally-averaged irradiances, we integrate the two- and four-stream biases using realistic diurnal variations of cloud properties from Clouds and the Earth’s Radiant Energy System (CERES) synoptic (SYN) hourly product. Three approximations are examined in this study, delta-two-stream-Eddington (D2strEdd), delta- two-stream-quadrature (D2strQuad), and delta-four-stream-quadrature (D4strQuad). Irradiances computed by the Discrete Ordinates Radiative Transfer (DISORT) and Monte Carlo (MC) methods are used as references. The MC noises are further examined by comparing with DISORT results. When the biases are integrated with a one-day of solar zenith angle variation, regional biases of D2strEdd and D2strQuad reach up to 8 W/sq.m, while biases of D4strQuad reach up to 2 W/sq.m. When the biases are further averaged monthly or annually, regional biases of D2strEdd and D2strQuad can reach –1.5 W/sq.m in SW top-of-atmosphere (TOA) upward irradiances and +3 W/sq.m in surface downward irradiances. In contrast, regional biases of D4strQuad are within +0.9 for TOA irradiances and –1.2 W/sq.m for surface irradiances. Except for polar regions, monthly and annual global mean biases are similar, suggesting that the biases are nearly independent to season. Biases in SW heating rate profiles are up to –0.008 K/d for D2strEdd and –0.016 K/d for D2strQuad, while the biases of the D4strQuad method are negligible.