Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “battery control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Thermodynamic, Kinetic, and Transport Contributions to Hydrogen Evolution Activity and Electrolyte-Stability Windows for Water-in-Salt Electrolytes

Concentrated water-in-salt electrolytes (WiSEs) are used in aqueous batteries and to control electrochemical reactions for fuel production. The hydrogen evolution reaction is a parasitic reaction at the negative electrode that limits cell voltage in WiSE batteries and leads to self-discharge, and affects selectivity for electrosynthesis. Mitigating and modulating these processes is hampered by a limited fundamental understanding of HER kinetics in WiSEs. Here, in this study, we quantitatively assess how thermodynamics, kinetics, and interface layers control the apparent HER activities in 20 m LiTFSI. When the LiTFSI concentration is increased from 1 to 20 m, an increase in proton activity causes a positive shift in the HER equilibrium potential of 71 mV. The exchange current density, i o , derived from the HER branch for 20 m LiTFSI in 98% purity (0.56 ± 0.05 μA/cm Pt 2 ), however, is 8 times lower than for 20 m LiTFSI in 99.95% (4.7 ± 0.2 μA/cm Pt 2 ) and 32 times lower than for 1 m LiTFSI in 98% purity (18 ± 1 μA/cm Pt 2 ), demonstrating that the WiSE's impurities and concentration are both central in significantly suppressing HER kinetics. The ability and applicability of the reported methods are extended by examining additional WiSEs formulations made of acetates and nitrates.

25 ENERGY STORAGE↗

Stochastic Adaptive Droop Control in Frequency Regulation of Power Systems With Intermittent Generators

Modern power systems (MPSs), including microgrids (MGs), are increasingly incorporating multiple renewable energy sources (RESs) such as wind and solar power, as well as battery storage and controllable loads. While environmentally beneficial, these sources pose challenges for control and management due to their intermittent and stochastic nature, especially in maintaining frequency stability with multiple interconnected generators of varying capacities. Traditional droop control methods are effective in systems with generators that are dispatchable and have fixed generation capacities, but they fall short when applied to systems with RESs, where generation capacities are dynamic and affected by unpredictable environmental conditions. To address these challenges, this paper introduces a novel stochastic adaptive droop control (SADC) method for load frequency control (LFC). The proposed method adapts droop coefficients in real time, based on the measured stochastic data of power generation capacities, enabling more effective frequency regulation in systems with variable and intermittent power generation. Unlike traditional adaptive control methods, which assume constant or slowly-varying system parameters, this approach accounts for stochastic processes by modeling them as Markov chains, enabling robust performance under highly dynamic and unpredictable conditions. The key contributions of this work include the development of real-time droop coefficient adaptation algorithms, derivation of their stability and convergence properties, and the demonstration of the advantages of the method through simulations. Case studies highlight the improved performance of frequency regulation, particularly in addressing the impact of stochastic weather conditions and the benefits of reducing dependence on battery reserves in dealing with intermittency of RESs. Finally, this paper provides a comprehensive analysis of the theoretical foundations of the method, as well as practical implementation insights for future power systems with high penetration of RESs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Agent-Based Coordination Scheme for PV Integration (ABC4PV)

Renewables and especially photovoltaics (PV) have benefitted significantly from a host of incentives and policies targeted toward enhanced integration and adoption of specific energy technologies. However, with the push to move forward into a subsidy-free market framework, behind-the-meter residential PV applications have generally struggled to retain their value (unlike utility scale and commercial projects) [1]. This project focused on developing control-theoretic solutions aimed at improving the integration and interaction of behind-the-meter residential PV with other distribution system assets (controllable and non-controllable) to enhance the integrated value of residential PV. To this end, a suite of decentralized control methodologies have been developed to enable effective coordination and control of behind-the-meter residential load customers’ PV, battery storage systems (BSS), controllable loads and other similar assets within a distribution feeder. This interaction aims at procuring energy savings and, thus, energy bill savings. The main source of savings is drawn from reducing the effect of demand charge pricing and is realized at the feeder level, assuming community level interaction and management among the aforementioned assets. Optimal control of the assets is implemented with a distributed optimization methodology, leveraging consensus-based algorithms. The results gathered from the optimal control simulations demonstrates that the savings can be duly achieved and the algorithm decision times (to dynamically control asset set points, for example) are fast. As for the overall efficiency of PV+BSS systems, to procure energy savings from curtailment of the demand charge pricing effects, the optimal control is set up so as to minimize the variance of the load for all customers, throughout a feeder and throughout time in a rolling horizon scheduling with model predictive control. The control takes into account inter-temporal electrochemical storage (battery) degradation costs: specifically, we have developed a long-term lifetime model for the BSS that weighs in the effect of the degradation factor in the dispatch formulations, thus, a considerable operating cost that affects energy decision making. The levelized cost of energy (LCOE – redefined for the purpose of quantifying asset integration effectiveness through the customers’ energy cost) is shown to be below the threshold set for the combined PV+BSS topology of $ 0.14/kWh for multiple cases of PV penetration all the way up to 50%, provided that a policy of shared ownership of and savings is in place. Further, the LCOE calculated for the case before the deployment PV+BSS systems is also achievable, i.e. the deployment of PV+BSS, if planned and scheduled optimally. will have no effect on customers’ energy costs. From the control methodology viewpoint, the developed consensus-based algorithms are shown to converge for a wide range of problem cases (spanning normal operating scenarios and contingencies), guaranteeing dispatch solutions under forecasting errors, communication break-downs and cyber-security attacks. The proposed control solutions are scalable and real-time implementable, with dispatch computations and device set-point updates converging in less than 2s in most practical instances of the above events.

14 SOLAR ENERGY↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemo-mechanics unlocks hidden dynamics of lithium plating under stacking pressure

Understanding and mitigating lithium plating remains one of the most pressing challenges in advancing the safety and longevity of lithium-ion batteries (LIBs). Here, we present a novel integrative framework that combines in-operando swelling force measurements with a physics-based electro-chemo-mechanical model to uncover previously inaccessible insights into lithium plating dynamics under mechanical constraints. Unlike existing approaches that focus primarily on electrochemical signatures, our approach captures the coupled mechanical responses of commercial pouch cells during cycling, revealing how mechanical constraints fundamentally alter degradation pathways. We demonstrate that the use of a moderate stacking pressure suppresses lithium plating and enhances lithium stripping. This mechanically driven structural effect, coupled with the electrochemical process, significantly extends the linear aging regime in LIBs. Intriguingly, intermittent capacity recovery events that were observed during the battery cycling suggest dynamic lithium reactivation, a phenomenon rarely captured in real-time. This study pioneers a stress-aware methodology for diagnosing and managing lithium plating, establishing a new paradigm for real-time battery health monitoring. The findings offer transformative implications for the design of durable, high-performance LIB systems, opening new avenues for intelligent control strategies in battery management systems.

Bhowmick, Amit↗

Hierarchical Control of Megawatt-Scale Charging Stations for Electric Trucks with Distributed Energy Resources

Electrifying medium- and heavy-duty trucks is critical to decarbonizing the transportation sector. Energy needs of electric trucks will likely require megawatt-scale charging stations, which could significantly stress the electric distribution grid. Distributed energy resources (DER) can alleviate this stress and reduce charging costs with proper management. To that end, this work develops a hierarchical predictive control algorithm for future multi-port megawatt-scale charging stations that can provide real-time energy management for stations, decide charging rates, dispatch energy storage system (ESS), and provide grid voltage support. We integrate three algorithmic components: (i) an energy management optimization (EMO) that provides supervisory control to DER assets and charging loads at minute scale, (ii) a real-time energy management system (RT-EMS) that heuristically compensates for fast disturbances at sub-second scale, and (iii) a model predictive control (MPC)-based battery management system (BMS) that communicates future charging demands to the EMO, to manage the overall megawatt-scale site. Additionally, validation in a controller hardware-in-the-loop (CHIL) environment shows that the hierarchical controller can reduce the total energy consumption from the grid by approximately 28% compared to an uncontrolled case for the station configuration in this paper, without impacting charging time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designing Electrolytes With Controlled Solvation Structure for Fast‐Charging Lithium‐Ion Batteries

Recharging battery-powered electric vehicles (EVs) in a similar timeframe as those used for refueling gas-powered internal combustion vehicles is highly desirable for rapid penetration of the EV market. It is well known that the electrolyte in a battery plays a critical role in fast-charging capability of the battery because it determines the rate of ion transport together with its derived electrode/electrolyte interphases on both cathode and anode of the battery. In this study, the effects of contents of salt, coordinating solvent, and noncoordinating diluent on salt dissociation degree and electrolyte ionic conductivity are investigated, and a controlled solvation structure electrolyte is developed to improve the lithium ion mobility and conductivity in the electrolyte and to enhance the kinetics and stability of the electrode/electrolyte interphases in the battery. This electrolyte enables fast-charging capability of high energy density lithium-ion batteries (LIBs) at up to 5 C rate (12-min charging), which significantly outperforms the state-of-the-art electrolyte. The controlled solvation structure sheds light on the future electrolyte design for fast-charging LIBs.

25 ENERGY STORAGE↗

Systems and methods for power management using adaptive power split ratio

Methods and systems of power management in a hybrid vehicle are disclosed. A control system of the hybrid vehicle obtains battery temperature and catalyst temperature. The control system determines (a) whether the battery temperature is within an optimal battery temperature range and (b) whether the catalyst temperature is within an optimal catalyst temperature range. The control system determines a power split ratio (PSR) based on the determination of (a) and (b). The control system controls the engine and the motor-generator based on the determined PSR.

Ramakrishnan, Kesavan↗

Software defined grid energy storage

Today, consumer battery installations are isolated, physical devices. Virtual power plants (VPPs) allow consumer devices to aggregate for grid services, but they are are vertically integrated, vendor controlled systems (e.g., Tesla’s VPP). Consumer batteries are therefore unable to participate in energy markets or other grid services outside what their vendor provides. We describe a software system that provides software control of multiple, networked battery energy storage systems in the electric grid. The system introduces two new ideas that enable flexible and dependable management of energy storage. The first is a virtual battery, which can either partition a battery or aggregate multiple batteries. The second is a reservation-based API which allows asynchronous control of batteries to meet contractual guarantees in a safe and dependable manner. Virtual batteries and a reservation-based API address the unique challenges of achieving high and efficient utilization of energy storage systems, including heterogeneity of battery systems such as varying C-rates, participation in energy markets, utility bill management systems, community resource sharing, and reliability. Using a testbed comprised of sonnen Inc. storage units installed in several homes and a lab, we demonstrate that virtualized batteries can seamlessly replace physical batteries, flexibly manage energy storage resources, isolate multiple clients using a shared battery, and create new energy storage applications.

25 ENERGY STORAGE↗

Controlling dendrite propagation in solid-state batteries with engineered stress

Metal-dendrite penetration is a mode of electrolyte failure that threatens the viability of metal-anode-based solid-state batteries. Whether dendrites are driven by mechanical failure or electrochemical degradation of solid electrolytes remains an open question. If internal mechanical forces drive failure, superimposing a compressive load that counters internal stress may mitigate dendrite penetration. Here, we investigate this hypothesis by dynamically applying mechanical loads to growing dendrites in Li 6.6 La 3 Zr 1.6 Ta 0.4 O 12 solid electrolytes. Operando microscopy reveals marked deflection in the dendrite growth trajectory at the onset of compressive loading. For sufficient loading, this deflection averts cell failure. Using fracture mechanics, we quantify the impact of stack pressure and in-plane stresses on dendrite trajectory, chart the residual stresses required to prevent short-circuit failure, and propose design approaches to achieve such stresses. For the materials studied here, we show that dendrite propagation is dictated by electrolyte fracture, with electronic leakage playing a negligible role.

25 ENERGY STORAGE↗

Chemical factors controlling the behaviour of oxide cathodes in batteries

Oxide cathodes enable high-energy lithium-ion and sodium-ion batteries, with their performances fundamentally governed by three interrelated chemical factors: electronic configuration, chemical bonding, and chemical reactivity. Here, we illustrate how these factors dictate the redox energy, structural stability, ionic and electronic transport, and interfacial behavior in both layered oxide and polyanion oxide cathodes. We discuss how crystal-field effects and octahedral-site stabilization energies influence cation migration, and how inductive effects tune bond covalency and operating voltages. We also explain how chemical bonding governs thermal stability, gas evolution, and first-cycle capacity loss, and how alignment of transition-metal redox band with the oxygen 2p band determines electrolyte reactivity. Comparison between lithium and sodium layered oxides further reveals how differences in Li-O and Na-O bond ionicity affect chemical reactivity. Finally, we outline strategies including compositional tuning, surface doping, and electrolyte optimization, and emphasize how high-throughput, data-driven approaches in guiding the design of next-generation oxide cathodes.

25 ENERGY STORAGE↗

Defect formation and microstructure tuning via proton irradiation to control electrochemical and phase reversibility in layered battery materials

The reversibility of phase transformation influences the functionality of electrode materials in batteries. In many battery materials, nanosized grains favor phase reversibility but at the cost of cyclability due to aggravated side reactions with the electrolyte. Here, in this study, we present a novel approach to enhance the phase transformation reversibility of layered oxide cathodes, exemplified by Na 2/3 Fe 1/2 Mn 1/2 O 2 through proton irradiation. In addition to forming defects, proton irradiation at sufficiently high doses can subdivide single grains into multiple nanodomains without physically rupturing them. Hence, the single grains of the material assume a pseudo-secondary particle nature without reducing the overall grain size. Preserving the grain size is advantageous, as it reduces side reactions, which is not possible with conventional grain size reduction methods. While chemical transformations and defect formation induced through proton irradiation can influence the stability of battery materials, it is expected that structural reorganization due to cycling-induced phase transformation will be contained within these nanodomains. Such confinement of phase transformation is potentially responsible for enhancing the reversibility of layered oxide materials in our study. Thus, our study suggests that grain subdivision could become an effective microstructure tuning strategy for managing electrochemical cycling-induced phase changes in battery electrodes.

25 ENERGY STORAGE↗

Sulfur Loaded MS 2 Barrier for Control of Polysulfide Shuttling in Lithium Sulfur Batteries (Final Report)

The lithium/sulfur battery system provides the opportunity for high capacity and low-cost batteries, and addresses the several challenges facing this technology including the need for improved rate capability and capacity retention. The presence of both 2D MS 2 nanosheets and sulfur will provide several advantages to address the limitations, including enhanced conductivity to the inherently insulating sulfur by the inclusion of MS 2 nanosheets, as well as utilizing the nanosheets to entrap negatively charged polysulfide species to prevent polysulfide shuttling and extend cycle life meeting Battery500 Program goals.

25 ENERGY STORAGE↗

Understanding and Strategies for Controlled Interfacial Phenomena in Lithium-Ion Batteries and Beyond

Electrolyte chemistry and properties and electrode structure and chemical properties particularly at the interfaces are crucial for the development of advanced battery components. This project focused on elucidating the roles of the electrolyte and electrode on the formation and evolution of the SEI layer and cell electrochemical performance on silicon and on Li metal anodes. For Si nano/microstructures we evaluated lithiation, volume changes, reactivity, and chemo-mechanical transformations as functions of nanoparticle size, shape, presence of coatings, electrolyte composition, electron leakage to the electrolyte, and cycling. For Li metal anodes we provided detailed analyses of the electrode and electrolyte effects on interfacial reactivity and as a function of microstructural evolution and underlying stochasticity as dendrites nucleate and grow. We thoroughly investigated and simulated how the chemistry of the various components of the electrolyte and the electrode architecture may affect the electrochemical reactions as well as cell degradation. A multiscale modeling approach was utilized, where atomistic simulations informed about the microscopic behavior of the system, and intermediate time and length scales were investigated with mesoscopic models. Results were also tested against selected experiments from our collaborators. The combined theoretical-experimental strategy saves costs by utilizing predictions from computational analyses to guide experimentation.

25 ENERGY STORAGE↗

Evaluation of bio-inspired flow fields in a mediated Li-S flow battery for grid energy storage

Lithium-sulfur is a redox flow battery with high energy density for applications in safe, reliable, and lasting scaling of energy. However, lithium-based batteries often encounter platting as a problem thanks to poor Li-ions deposition after cycling. Aiming to reduce this impact, a uniform and continuous flow of ions is needed. On this work, novel bio-inspired flow fields in the electrochemical cell were tested to improve ions flowability and lithium platting control, ultimately enhancing battery performance and life. To secure Li-S efficient, low-cost, and secure energy storage capabilities, we chose a configuration with decamethylferrocene and cobaltocene acting as redox mediators, Li metal as anode and sulfur kept in a separate catholyte reservoir. Flow test and battery results insinuated a beneficial influence of bio-inspired designs in flowing electrolyte uniformly with less pressure and pump power in comparison to other conventional designs used in the industry, with an encouraging ability to approach a cheap, safe, and reliable Li-S grid energy storage.

25 ENERGY STORAGE↗

Scheduling and Control of Flexible Building Loads for Grid Services Based on a Virtual Battery Model

This paper presents a framework for modeling, scheduling, and controlling residential thermostatically controlled loads (TCLs) to provide multiple grid services, such as energy shifting, peak load reduction, and ancillary services. A modeling method is proposed to characterize the aggregate flexibility from heterogeneous TCLs using a battery-equivalent model. Based on the flexibility model, a multi-period optimal scheduling formulation is developed to best utilize the flexibility from building loads and maximize total benefits from stacked value streams. An algorithm is proposed to control individual TCLs to follow the desired power consumption in real-time. The proposed methods are illustrated and validated through simulations.

Wu, Di↗