Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “authorization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Hydrogen applications in airport operations: a review using the Port Authority of New York and New Jersey as an illustrative airport system

Airports combine aircraft propulsion, ground operations, stationary power systems, and fuel logistics in ways that make emissions reduction technically and operationally complex. Existing studies often assess hydrogen applications in these areas separately, limiting understanding of the shared infrastructure, safety, and operational constraints that shape airport deployment. This review evaluates hydrogen across three airport-relevant operational domains: aviation propulsion, ground support equipment and vehicles, and stationary power systems. Within aviation propulsion, the review examines sustainable aviation fuel production and hydrogen-powered aircraft as two distinct hydrogen-relevant pathways. The Port Authority of New York and New Jersey is used as an illustrative airport system to relate the literature to a real operating context. Drawing on peer-reviewed studies, technical reports, demonstration projects, and public operational information, the review also includes screening-level calculations of hydrogen demand and potential CO 2 e reductions for selected applications. The findings show that hydrogen's role is highly application-specific. Near-term opportunities are strongest where hydrogen serves as a low-carbon process input, supports selected high-utilization ground equipment, or contributes to resilient stationary power-system configurations. Hydrogen-powered aircraft remain a longer-term option because storage, fueling infrastructure, certification, cost, and NO x management continue to constrain deployment. Across all domains, infrastructure readiness, fuel logistics, safety requirements, and leakage management emerge as recurring determinants of viability. Future research should focus on cross-domain infrastructure planning, comparative assessment of hydrogen against alternative pathways, improved treatment of leakage and non-CO 2 effects, and clearer safety and regulatory frameworks for airport deployment.

08 HYDROGEN↗

A model of interaction between anticorruption authority and corruption groups

The paper provides a model of interaction between anticorruption unit and corruption groups. The main policy functions of the anticorruption unit involve reducing corrupt practices in some entities through an optimal approach to resource allocation and effective anticorruption policy. We develop a model based on Markov decision-making process and use Howard’s policy-improvement algorithm for solving an optimal decision strategy. We examine the assumption that corruption groups retaliate against the anticorruption authority to protect themselves. This model was implemented through stochastic game.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Peoria Housing Authority(PHA) Weatherization Training Project

The DOE Weatherization Training Project's goal is to obtain a solid foundation of administrative and technical knowledge so the Peoria Housing Authority (PHA) can establish and implement a successful Weatherization Program by 2011. The DOE weatherization Training Project's two objectives are to (1) build PHA's capabilities by (2) developing its staff members capacities via the acquisition of weatherization skills and competencies. The impacts from this project include: (a) the improvement and expansion of PHA staff skills, (b) the overall enhancement of the quality of the PHA workforce, which will (c) foster employment, (d) the ability to properly weatherize PHA housing stock, tribal buildings, and tribal members houses, which will (e) result in reduced energy use, and (f) improved tribal and household economies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Seismic Imaging and Inversion: Application of Linear Theory (2012), Cambridge University Press, co-authored with Bob Stolt

Extracting information from seismic data requires knowledge of seismic wave propagation and reflection. The commonly used method involves solving linearly for a reflectivity at every point within the Earth, but this book follows an alternative approach which invokes inverse scattering theory. By developing the theory of seismic imaging from basic principles, the authors relate the different models of seismic propagation, reflection and imaging - thus providing links to reflectivity-based imaging on the one hand and to nonlinear seismic inversion on the other. The comprehensive and physically complete linear imaging foundation developed presents new results at the leading edge of seismic processing for target location and identification. This book serves as a fundamental guide to seismic imaging principles and algorithms and their foundation in inverse scattering theory and is a valuable resource for working geoscientists, scientific programmers and theoretical physicists.

58 GEOSCIENCES↗

Dose Modeling Evaluations and Technical Support Document for the Authorized Limits Request for the C-746-U Landfill at the Paducah Gaseous Diffusion Plant, Paducah, Kentucky

This report contains the technical basis in support of the DOE's derivation of Authorized Limits (ALs) for the DOE Paducah C-746-U Landfill. A complete description of the methodology, including an assessment of the input parameters, model inputs, and results is provided in this report. This report also provides initial recommendations on applying the derived soil guidelines. The ORISE-derived soil guidelines are specifically applicable to the Landfill at the end of its operational life. A suggested 'upper bound' multiple of the derived soil guidelines for individual shipments is provided.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dose Modeling Evaluations and Technical Support Document For the Authorized Limits Request for the DOE-Owned Property Outside the Limited Area, Paducah Gaseous Diffusion Plant Paducah, Kentucky

Environmental assessments and remediation activities are being conducted by the U.S. Department of Energy (DOE) at the Paducah Gaseous Diffusion Plant (PGDP), Paducah, Kentucky. The Oak Ridge Institute for Science and Education (ORISE), a DOE prime contractor, was contracted by the DOE Portsmouth/Paducah Project Office (DOE-PPPO) to conduct radiation dose modeling analyses and derive single radionuclide soil guidelines (soil guidelines) in support of the derivation of Authorized Limits (ALs) for "DOE-Owned Property Outside the Limited Area"; ("Property") at the PGDP. The ORISE evaluation specifically included the area identified by DOE restricted area postings (public use access restrictions) and areas licensed by DOE to the West Kentucky Wildlife Management Area (WKWMA). The licensed areas are available without restriction to the general public for a variety of (primarily) recreational uses. Relevant receptors impacting current and reasonably anticipated future use activities were evaluated. In support of soil guideline derivation, a Conceptual Site Model (CSM) was developed. The CSM listed radiation and contamination sources, release mechanisms, transport media, representative exposure pathways from residual radioactivity, and a total of three receptors (under present and future use scenarios). Plausible receptors included a Resident Farmer, Recreational User, and Wildlife Worker. single radionuclide soil guidelines (outputs specified by the software modeling code) were generated for three receptors and thirteen targeted radionuclides. These soil guidelines were based on satisfying the project dose constraints. For comparison, soil guidelines applicable to the basic radiation public dose limit of 100 mrem/yr were generated. Single radionuclide soil guidelines from the most limiting (restrictive) receptor based on a target dose constraint of 25 mrem/yr were then rounded and identified as the derived soil guidelines. An additional evaluation using the derived soil guidelines as inputs into the code was also performed to determine the maximum (peak) dose for all receptors. This report contains the technical basis in support of the DOE's derivation of ALs for the "Property"; A complete description of the methodology, including an assessment of the input parameters, model inputs, and results is provided in this report. This report also provides initial recommendations on applying the derived soil guidelines.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EEB Hub Regional Sankey Diagram: Philadelphia Authority for Industrial Development Historical and Forecast Energy by Planned Use at the Philadelphia Navy Yard

The Energy Efficient Buildings Hub (EEB Hub) is a DOE-funded center, focused on improving the energy use in commercial and large-scale residential buildings. One of the Hub’s goals has been to develop the means and methods to reduce energy use in commercial buildings by 20 percent by 2020. Understanding energy use in buildings is a key component to managing energy use at multiple scales, from the building to the city, to the region. Sankey diagrams are an accessible tool to visualize energy flows, and help identify opportunities to deploy energy saving technologies. A campus-level Sankey diagram was previously generated from 2010-2011 data for ~100 metered Navy Yard buildings to quantify natural gas and electricity usage by principal building activity. As these properties are renovated, the energy consumption and building principal activities are being updated and modified. To depict the multi-year time lapse of regional electricity distribution in the Navy Yard, LLNL generated Sankey diagrams using data from 36 properties (buildings, developments, equipment) used to develop Philadelphia Authority for Industrial Development’s (PIDC) Navy Yard Master Energy Plan (NYEMP). The diagrams presented in this report depict ~10 building use types and the yearly changes in forecasted usage in GWh from 2011 to 2022. The forecast captures increases in regional energy use from planned building additions and renovations and yearly increases for existing buildings. From 2009 to 2022, there is approximately 5.6 million square feet of planned additions and renovations. The largest addition of properties are for office (~ 2.3 million square feet for dedicated office, and larger for shared office space) and residential space (~1 million square feet). Until 2014, the largest user of energy is for flex space, reaching a forecasted 11.4 GWh. In 2015-2016, the largest forecasted user is for a data center reaching ~25.7 GWh. After 2016, the largest consumers are either for office space (reaching 63.2 GWh forecast in 2022), or heavy industry (68 GWh forecast in 2022).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sandia and NJ TRANSIT Authority Developing Resilient Power Grid

Through the memorandum of understanding between the Depratment of Energy (DOE), the New Jersey Transit Authority (NJ Transit), and the New Jersey Board of Public Utilities, Sandia National Labs is assisting NJ Transit in developing NJ TransitGrid: an electric microgrid that will include a large-scale gas-fired generation facility and distributed energy resources (photovoltaics [PV], energy storage, electric vehicles, combined heat and power [CHP]) to supply reliable power during storms or other times of significant power failure. The NJ TransitGrid was awarded $410M from the Department of Transportation to develop a first-of-its-kind electric microgrid capable of supplying highly-reliable power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Review of the Campbell Creek Demonstrations Showcased by Tennessee Valley Authority

The Tennessee Valley Authority (TVA) Technology Innovation, Energy Efficiency, Power Delivery and Utilization Office funded and managed a showcase demonstration located in the suburbs of west Knox county, Tennessee. Work started March 2008 with the goal of documenting best practices for retrofitting existing homes and for building new high-efficiency homes. The Oak Ridge National Laboratory and the Electric Power Research Institute (EPRI) provided technical support. An analytical base was developed for helping homeowners, homebuyers, builders, practitioners and the TVA make informed economic decisions for the materials and incentives necessary to build a new high-efficiency home or retrofit an existing home. New approaches to more efficiently control active energy subsystems and information for selecting or upgrading to Energy Star appliances, changing all lights to 100% CFL s and upgrading windows to low-E gas filled glazing yields a 40% energy savings with neutral cash flow for the homeowner. Passive designs were reviewed and recommendations made for envelope construction that is durable and energy efficient. The Campbell Creek project complements the DOE Building Technologies Program strategic goal. Results of the project created technologies and design approaches that will yield affordable energy efficient homes. The 2010 DOE retrofit goals are to find retrofit packages that attain 30% whole house energy savings as documented by pre and post Home Energy rating scores (HERS). Campbell Creek met these goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline. Five Steps to Implement the Public Housing Authority Energy-Efficient Unit Turnover Checklist

Five Steps to Implementing the PHA Energy Efficient Unit Turnover Package (ARIES, 2014) is a guide to prepare for the installation of energy efficient measures during a typical public housing authority unit turnover. While a PHA is cleaning, painting and readying a unit for a new resident, there is an opportunity to incorporate energy efficiency measures to further improve the unit's performance. The measures on the list are simple enough to be implemented by in-house maintenance personnel, inexpensive enough to be folded into operating expenses without needing capital budget, and fast enough to implement without substantially changing the number of days between occupancies, a critical factor for organizations where the demand for dwelling units far outweighs the supply. The following guide lays out a five step plan to implement the EE Unit Turnover Package in your PHA, from an initial Self-Assessment through to Package Implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Costs and Benefits of Resilience Investments: Tennessee Valley Authority Case Study

This report describes a general approach for assessing climate change vulnerabilities of an electricity system and evaluating the costs and benefits of certain investments that would increase system resilience. It uses Tennessee Valley Authority (TVA) as a case study, concentrating on the Cumberland River basin area on the northern side of the TVA region. The study focuses in particular on evaluating risks associated with extreme heat wave and drought conditions that could be expected to affect the region by mid-century. Extreme climate event scenarios were developed using a combination of dynamically downscaled output from the Community Earth System Model and historical heat wave and drought conditions in 1993 and 2007, respectively.

54 ENVIRONMENTAL SCIENCES↗

A Preliminary Review of U.S. Forest Service Business Practices To Authorize Special Uses, Including Energy Infrastructure Projects, on National Forest System Lands

The U.S. Forest Service (USFS) Special Uses-Lands Program is in jeopardy. Although this program, authorized in Title 36, Part 251, of the U.S. Code of Federal Regulations (36 CFR Part 251), ranks among the top four revenue-generating programs for use of National Forest System (NFS) lands, along with the Timber, Minerals, and Special Uses-Recreation Programs, the Special Uses-Lands Program is in a state of neglect. Repeated cuts in funding (a decrease of 26% from fiscal years 2010 to 2014) are adversely affecting staffing and training, which in turn is affecting timely permit processing and ultimately the public’s ability to use and benefit from NFS lands. In addition, highly experienced staff with valuable institutional knowledge of the program have begun to retire. The ability of the program to function under these dire circumstances can be attributed to the dedication of Special Uses staff to the program and their commitment to the public. The initial focus of this report was to identify opportunities for improving performance of permitting and review for large energy infrastructure-related projects. However, it became clear during this analysis that these projects are generally adequately staffed and managed. This is due in large part to the availability of cost-recovery dollars and the high-profile nature of these projects. However, it also became apparent that larger issues affecting the bulk of the work of the Special Uses-Lands Program need to be addressed immediately. This report is a preliminary examination of the state of the Special Uses-Lands Program and focuses on a few key items requiring immediate attention. Further investigation through case studies is recommended to dig deeper into the Special Uses-Lands Program business process to determine the most costeffective strategies for streamlining the overall process and the metrics by which performance can be evaluated, including for the permitting and tracking of energy infrastructure projects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Model Authorized Product Realization MAP-R

The agenda for this presentation covers the Model Authorized Product — Realization (MAPR); Project Background; Data Collected; Observations & Findings; Next Steps; MBE Level 3+; Research on 3D interactive viewable(s) (3DIV).

36 MATERIALS SCIENCE↗

Zero-Emission Bus Evaluation Results: Orange County Transportation Authority Fuel Cell Electric Bus

This report summarizes the experience and results from a demonstration of a fuel cell electric bus operated by the Orange County Transportation Authority (OCTA). This report presents evaluation results for the FCEB in comparison to baseline buses in similar service. The focus of the analysis is on the most recent year of service, from June 2017 through May 2018.

33 ADVANCED PROPULSION SYSTEMS↗

Fleet-wide Electrification Impacts Assessment for the Valley Transportation Authority

This report explores the long-term electrification opportunities for the Valley Transit Authority’s (VTA) transit bus fleet. The potential for transit bus electrification at VTA as well as the economic impacts of partial and complete electrification are explored. We use the Revenue Operation and Device Optimization model to determine the optimal charging, operation and lowest capital and operating cost solution to achieve different levels of electrification to meet their existing routes. This study finds that, relying on only depot charging, around 70% of the daily trips by VTA’s transit bus fleet can be replaced with battery electric buses (BEBs) today. The benefits and drawbacks of five methods for improving the electrification potential beyond that achievable with only depot charging are discussed including (1) increase charger power, (2) purchase of larger vehicle batteries, (3) en-route charging, (4) purchasing additional buses and swapping them to enable the existing routes/blocks1 to be met, and (5) route/block redesign. A strategy is developed to enable full fleet electrification by increasing charger power or allowing intraday charging as a proxy for the options mentioned above. This method allows us to develop an understanding of the impacts and trade-offs of full fleet electrification. Two charging strategies are examined. Immediate charging, when the bus is charged as soon as it arrives at a depot or en-route charging station, and smart charging, which uses a controller to determine the best times to charge to achieve the lowest charging cost, while maintaining the same trip schedules. Smart charging is effective at reducing the peak power consumption, which can be reduced by between 31% and 65% compared to immediate charging. This translates directly to lower electricity demand charges and lower costs for possible distribution system upgrades. The total lifetime net present value (NPV) costs for different scenarios are presented in Figure ES-1. Scenarios are separated into three sections. The first stacked bar on the left is the base case (business-as-usual) where all buses are diesel hybrids, the next four bars include partial and full fleet electrification utilizing only immediate charging, and the last four bars include partial and full fleet electrification utilizing smart charging. The results show that smart charging scenarios are within ±4% of the lifetime NPV cost of the diesel-hybrid only (business-as-usual) scenario. The scenarios with full fleet electrification (i.e., including intraday charging) are 4% lower cost and those with partial fleet electrification (i.e., without intraday charging) are 2%–3% higher. However, it is important to note that the intraday charging scenarios do not include any additional costs for the equipment necessary to achieve intraday charging (e.g., additional chargers, larger batteries, new route design). Additionally, it is worth noting that the Low Carbon Fuel Standard (LCFS) credit received for implementing electric buses is essential to achieving these results.

33 ADVANCED PROPULSION SYSTEMS↗