Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atomically precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Decontamination of Genesis Array Materials by UV Ozone Cleaning

Shortly after the NASA Genesis Mission sample return capsule returned to earth on September 8, 2004, the science team discovered that all nine ultra-pure semiconductor materials were contaminated with a thin molecular organic film approximately 0 to 100 angstroms thick. The organic contaminate layer, possibly a silicone, situated on the surface of the materials is speculated to have formed by condensation of organic matter from spacecraft off-gassing at the Lagrange 1 halo orbit during times of solar exposure. While the valuable solar wind atoms are safely secured directly below this organic contamination and/or native oxide layer in approximately the first 1000 angstroms of the ultra-pure material substrate, some analytical techniques that precisely measure solar wind elemental abundances require the removal of this organic contaminate. In 2005, Genesis science team laboratories began to develop various methods for removing the organic thin film without removing the precious material substrate that contained the solar wind atoms. Stephen Sestak and colleagues at Open University first experimented with ultraviolet radiation ozone (UV/O3) cleaning of several non-flight and flown Genesis silicon wafer fragments under a pure flowing oxygen environment. The UV/O3 technique was able to successfully remove organic contamination without etching into the bulk material substrate. At NASA Johnson Space Center Genesis Curation Laboratory, we have installed an UV/O3 cleaning devise in an ambient air environment to further experimentally test the removal of the organic contamination on Genesis wafer materials. Preliminary results from XPS analysis show that the UV/O3 cleaning instrument is a good non-destructive method for removing carbon contamination from flown Genesis array samples. However, spectroscopic ellipsometry results show little change in the thickness of the surface film. All experiments to date have shown UV/O3 cleaning method to be the best non-destructive method for removing organic contamination from the surface of the Genesis materials. The UV/O3 cleaning process can also clean carbon contamination to levels below non-flight standards. This can be seen by comparing sample 60260's carbon 10667 cps with non-flight Si carbon 21675 cps. Therefore, surface carbon contamination should not hinder the analysis of solar wind.

Calaway, Michael J.↗

Photoionization and Recombination

Theoretically self-consistent calculations for photoionization and (e + ion) recombination are described. The same eigenfunction expansion for the ion is employed in coupled channel calculations for both processes, thus ensuring consistency between cross sections and rates. The theoretical treatment of (e + ion) recombination subsumes both the non-resonant recombination ("radiative recombination"), and the resonant recombination ("di-electronic recombination") processes in a unified scheme. In addition to the total, unified recombination rates, level-specific recombination rates and photoionization cross sections are obtained for a large number of atomic levels. Both relativistic Breit-Pauli, and non-relativistic LS coupling, calculations are carried out in the close coupling approximation using the R-matrix method. Although the calculations are computationally intensive, they yield nearly all photoionization and recombination parameters needed for astrophysical photoionization models with higher precision than hitherto possible, estimated at about 10-20% from comparison with experimentally available data (including experimentally derived DR rates). Results are electronically available for over 40 atoms and ions. Photoionization and recombination of He-, and Li-like C and Fe are described for X-ray modeling. The unified method yields total and complete (e+ion) recombination rate coefficients, that can not otherwise be obtained theoretically or experimentally.

Nahar, Sultana N.↗

Spaceborne clock system: Some alternatives for a proposed NASA experiment

A spaceborne clock experiment is proposed with the objectives of improving international time and frequency comparisons, studying precise one-way Doppler tracking and one-way ranging techniques, performing relativistic studies, and developing new atomic frequency standards technology. Various alternatives are considered for accomplishing these goals, including the use of existing satellite and earth-based time dissemination systems as well as the development of a new frequency standard for this specific application. One conclusion is that several attractive alternatives already exist for meeting the goal of improved time and frequency dissemination. However, to achieve all the other 4 goals at the NASA-stated levels of accuracy, a spaceborne atomic frequency standard may be required. An analysis of achievements to date with quartz oscillators, rubidium standards, cesium beam standards, hydrogen masers, and several other possibilities leads to the conclusion that cesium and rubidium standards offer the best choices for the experiment as proposed by NASA. The greatest obstacle to a spaceborne atomic standard appears to be its electrical power requirements.

Beehler, R. E.↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗

Measurement of the frequency stability of responders in aircraft

Measurement on an aircraft orbit, such as a satellite launching orbit, is made by the responder in the aircraft along with several remote track stations on the ground. During the launching, the system is required to have precise time synchronization and frequency accuracy. At the same time, accurate measurement of aircraft velocity requires high frequency stability of the system. However, atomic frequency standards in the ground stations supply time and frequency reference standard with excellent long term and short term frequency stability for the above-mentioned goals. The stability of responder is also an important factor affecting the performance of the system and there are more requirements for the corresponding time/frequency measurements. In the system, the responders do not use continuous wave (CW) but narrow pulse modulated wave; consequently, the characterization theory of their stability is more complicated and the measurement technique is more difficult for pulsed wave than that for CW. A systematic characterization theory of the frequency stability for pulsed wave is demonstrated and the measuring methods are discussed. The measurement systems, which have been set up in Beijing Institute of Radio Metrology and Measurement (BIRMM) and can be used to test the frequency stability of pulse coherent responders in time domain and frequency domain with high sensitivity and accuracy, are described. Using these measurement systems, successful measurements for the responders were made with which the satellite launching orbits were precisely obtained and tracked.

Liu, Xiaofan↗

Genesis Solar Wind – Capture, Return, Curate and Analyze: Looking Backward Reviewing Sample Collection Hardware

Genesis, as the first U.S. spacecraft to return astromaterial samples since Apollo, not only integrated the mission planning and flight teams, but also the science and sample curation teams during the mission development period. Since Genesis is a sample return mission, the Science Team was essential in certifying the collectors (sample containers for solar atoms). Burnett and the science team defined the purity of collector materials and ability to analyze solar wind composition to the precision required for planetary science. The science team’s choices included a variety of very pure materials which are described, including rationale for selection. The JPL Project Scientist networked with specialty vendors refining specifications and fabricating several of the materials. JPL engineering team designed and fabricated the collector arrays. LANL designed and built an electrostatic concentrator. JSC procured these materials with exacting specifications.

SOLAR WIND↗

Laboratory Instruments Available to Support Space Station Researchers at Marshall Space Flight Center

A number of research instruments are available at NASA's Marshall Space Flight Center (MSFC) to support ISS researchers and their investigations. These modern analytical tools yield valuable and sometimes new informative resulting from sample characterization. Instruments include modern scanning electron microscopes equipped with field emission guns providing analytical capabilities that include angstron-level image resolution of dry, wet and biological samples. These microscopes are also equipped with silicon drift X-ray detectors (SDD) for fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations in crystalline alloys. Sample chambers admit large samples, provide variable pressures for wet samples, and quantitative analysis software to determine phase relations. Advances in solid-state electronics have also facilitated improvements for surface chemical analysis that are successfully employed to analyze metallic materials and alloys, ceramics, slags, and organic polymers. Another analytical capability at MSFC is a mganetic sector Secondary Ion Mass Spectroscopy (SIMS) that quantitatively determines and maps light elements such as hydrogen, lithium, and boron along with their isotopes, identifies and quantifies very low level impurities even at parts per billion (ppb) levels. Still other methods available at MSFC include X-ray photo-electron spectroscopy (XPS) that can determine oxidation states of elements as well as identify polymers and measure film thicknesses on coated materials, Scanning Auger electron spectroscopy (SAM) which combines surface sensitivity, spatial lateral resolution (approximately 20 nm), and depth profiling capabilities to describe elemental compositions in near surface regions and even the chemical state of analyzed atoms. Conventional Transmission Electron Microscope (TEM) for observing internal microstructures at very high magnifications and the Electron Probe Micro-analyzer (EPMA) for very precise microanalysis are available as needed by the researcher. Space Station researchers are invited to work with MSFC in analyzing their samples using these techniques.

Panda, Binayak↗

Some optical and kinetic properties of the nearby interstellar gas

A model for resonant scattering of sunlight by the nearby interstellar gas is developed which takes into account the modification of a Maxwell-Boltzmann velocity distribution by a central force. While the formalism applies to both hydrogen and helium, the latter is emphasized. Theoretical line profiles and integrated emission rates for helium are compared with those of approximate models and with existing observations. As a result of this analysis, an upward revision of the bulk flow velocity of interstellar helium relative to the solar system, previously deduced from He 584-A observations, is required. Velocities of 15-20 km/s, temperatures of the order of 5000-10,000 K, and densities of the order of 0.008-0.02 per cu cm are sufficient to explain the (helium) observations. However, higher-precision measurements are required in order to place more stringent limits on the gas parameters. Calculations of the flux of interstellar helium atoms impinging on earth's upper atmosphere show that the resulting impact ionization is small compared with terrestrial processes.

Meier, R. R.↗

Identification of Fe I lines in the ultraviolet solar spectrum

High-resolution ultraviolet echelle spectrograms of the sun obtained from a rocket-borne spectrograph have been used for the identification of Fe I absorption lines in the wavelength range 1770-2020 A. Wavelength measurements, with a precision of about 15 mA, are tabulated for 425 Fe I features, along with available laboratory wavelenghs or predicted wavelengths calculated from atomic energy level data. The classification system of Moore has been extended to include possible additional multiplets with 126 newly classified lines; 234 unclassified lines were observed and identified with laboratory Fe I spectra

Mccabe, M. K.↗

Millisecond pulsar observation system at CRL

Millisecond pulsars have attracted attention as future reference clocks in place of present atomic clocks. The Communications Research Laboratory (CRL) has been developing an observation system to measure the pulse timing of a millisecond pulsar precisely, and has recently completed the basic part of the task. We observed PSR1937+21 at 1.5GHz band and got a pulse timing with a precision of 16 micro sec/tau by five days of observation.

Hanado, Yuko↗

Precise timing of the last interglacial period from mass spectrometric determination of thorium-230 in corals

The development of mass spectrometric techniques for determination of Th-230 abundance has made it possible to reduce analytical errors in (U-238)-(U-234)-(Th-230) dating of corals even with very small samples. Samples of 6 x 10 to the 8th atoms of Th-230 can be measured to an accuracy of + or - 3 percent (2sigma), and 3 x 10 to the 10th atoms of Th-230 can be measured to an accuracy of + or - 0.2 percent. The time range over which useful age data on corals can be obtained now ranges from about 50 to about 500,000 years. For young corals, this approach may be preferable to C-14 dating. The precision with which the age of a coral can now be determined should make it possible to critically test the Milankovitch hypothesis concerning Pleistocene climate fluctuations. Analyses of a number of corals that grew during the last interglacial period yield ages of 122,000 to 130,000 years. The ages coincide with, or slightly post-date, the summer solar insolation high at 65 deg N latitude which occurred 128,000 years ago. This supports the idea that changes in Pleistocene climate can be the result of variations in the distribution of solar insolation caused by changes in the geometry of the earth's orbit and rotation axis.

Chen, J. H.↗

FUN with PANURGE - High mass resolution ion microprobe measurements of Mg in Allende inclusions

Isotopic ratios have been determined, at a precision level approaching that of counting statistics using beam switching, by employing PANURGE, a modified CAMECA IMS3F ion microprobe at a mass resolving power of 5000. This technique is used to determine the isotopic composition of Mg and Si and the atomic ratio of Al/Mg in minerals from the Allende inclusion WA and the Allende FUN inclusion C1. Results show enrichment in Mg-26 of up to 260 percent. Results of Mg and Al/Mg measurements on cogenetic spinel inclusion and host plagiclase crystals show Mg-Al isochrons in excellent agreement with precise mineral isochrons determined by thermal emission mass spectrometry. The measurements are found to confirm the presence of substantial excess Mg-26 in WA and its near absence in C1. Data is obtained which indicates a metamorphic reequilibrium of Mg in Allende plagioclase at least 0.6 my after WA formation. Ion probe measurements are obtained which confirm that the Mg composition in Allende C1 is highly fractionated and is uniform among pyroxene, melilite, plagioclase, spinel crystals, and spinel included in melilite and plagioclase crystals.

Huneke, J. C.↗

Two-way time transfer modem

The Naval Research Laboratory is developing a two-way time transfer modem that will work with very small aperture terminals (VSAT), commercial satellites, and an atomic clock. The two-way method was chosen because of its performance and insensitivity to the position of the receivers and satellites. Precision, stability, accuracy, and varsatility are the primary design considerations of this modem. The modem is designed to use many off the shelf components.

Galysh, Ivan J.↗

Annihilation during positron-hydrogen collisions

Using the precision s- and p-wave elastic-scattering wave functions obtained previously, we have calculated the annihilation rate for positrons colliding with hydrogen atoms below the positronium-formation threshold. The s-wave results agree well with those of Humberston, while the p-wave results, which are new, contribute about 20% of the total at the higher energies.

Bhatia, A. K.↗

Equilibrium properties of chemically reacting gases

The equilibrium energy, enthalpy, entropy, specific heat at constant volume and constant pressure, and the equation of state of the gas are all derived for chemically reacting gas mixtures in terms of the compressibility, the mol fractions, the thermodynamic properties of the pure gas components, and the change in zero point energy due to reaction. Results are illustrated for a simple diatomic dissociation reaction and nitrogen is used as an example. Next, a gas mixture resulting from combined diatomic dissociation and atomic ionization reactions is treated and, again, nitrogen is used as an example. A short discussion is given of the additional complexities involved when precise solutions for high-temperature air are desired, including effects caused by NO produced in shuffle reactions and by other trace species formed from CO2, H2O and Ar found in normal air.

Source record↗

Initial Test Results for NASA Goddard’s Low-Cost Optical Terminal Adaptive Optics System

This presentation presents the testing approach and initial laboratory test results of the Adaptive Optics (AO) Subassembly (AOS) for the Low-Cost Optical Terminal (LCOT), a low-cost and flexible optical communications ground terminal. Leveraging commercial components and subassemblies wherever possible, LCOT is being developed by the NASA Goddard Space Flight Center (GSFC) Advanced Communications Capabilities for Exploration and Science Systems (ACCESS) project. An economical ground terminal allows NASA to create a global optical terminal network and enables the expansion of direct-to-Earth (DTE) optical communications. Located at the Goddard Geophysical and Astronomical Observatory (GGAO), LCOT is in the development phase and will receive first light during initial testing beginning in 2023. This new optical terminal includes a 700 mm Ritchey-Chretien commercial telescope, able to track Low Earth Orbit (LEO) spacecraft, receive instruments specified from 1500 - 1600 nm, and an uplink transmit optical system. Demodulation of optical coherent modulation formats requires downlink signal coupling into single-mode fiber. Due to atmospheric turbulence, signals experience wavefront distortions creating speckle patterns larger than the fiber core and high jitter requiring precise beam steering. AO is necessary to correct atmospheric turbulence effects and allow efficient coupling of received signals. In 2020, GSFC contracted with General Atomics to provide the LCOT AO system. This system has been delivered to GSFC in September 2021 and has been tested in laboratory to evaluate performance. This paper describes the laboratory testing approach, turbulence phase plate design, test results, and the AO field testing plan when installed on the LCOT telescope.

Adaptive Optics↗