Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atomic clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Quantum-amplified global-phase spectroscopy on an optical clock transition

Optical lattice clocks are at the forefront of precision metrology, operating near a standard quantum limit set by quantum noise. Harnessing quantum entanglement offers a promising route to surpass this limit; however, there are practical difficulties in terms of scalability and measurement resolution requirements. Here we adapt the holonomic quantum gate concept to develop a new Rabi-type ‘global-phase spectroscopy’ that uses the detuning-sensitive global Aharonov–Anandan phase19. With this approach, we can demonstrate quantum-amplified time-reversal spectroscopy on an optical clock transition that achieves directly measured 2.4(7) dB metrological gain and 4.0(8) dB improvement in laser noise sensitivity beyond the standard quantum limit. To this end, we introduce rotary echo to protect the dynamics from inhomogeneities in light–atom coupling and implement a laser-noise-cancelling differential measurement through symmetric phase encoding in two nuclear spin states. Our technique is not limited by measurement resolution, scales easily because of the global nature of entangling interaction and exhibits high resilience to typical experimental imperfections. As a result, we expect it to be broadly applicable to next-generation atomic clocks and other quantum sensors approaching the fundamental quantum precision limits.

Zaporski, Leon [Massachusetts Institute of Technol↗

Extended Coherence Time on the Clock Transition of Optically Trapped Rubidium

Optically trapped ensembles are of crucial importance for frequency measurements and quantum memories but generally suffer from strong dephasing due to inhomogeneous density and light shifts. We demonstrate a drastic increase of the coherence time to 21 s on the magnetic field insensitive clock transition of {sup 87}Rb by applying the recently discovered spin self-rephasing [C. Deutsch et al., Phys. Rev. Lett. 105, 020401 (2010)]. This result confirms the general nature of this new mechanism and thus shows its applicability in atom clocks and quantum memories. A systematic investigation of all relevant frequency shifts and noise contributions yields a stability of 2.4x10{sup -11{tau}-1/2}, where {tau} is the integration time in seconds. Based on a set of technical improvements, the presented frequency standard is predicted to rival the stability of microwave fountain clocks in a potentially much more compact setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity of hyperfine structure to nuclear radius and quark mass variation

To search for the temporal variation in the fundamental constants, one needs to know dependence of atomic transition frequencies on these constants. We study the dependence of the hyperfine structure of atomic s levels on nuclear radius and, via radius, on quark masses. An analytical formula has been derived and tested by the numerical relativistic Hartree-Fock calculations for Rb, Cd{sup +}, Cs, Yb{sup +}, and Hg{sup +}. The results of this work allow the use of the results of past and future atomic clock experiments and quasar spectra measurements to put constraints on time variation in the quark masses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Frequency reproducibility of solid-state thorium-229 nuclear clocks

Solid-state thorium-229 ( 229 Th) nuclear clocks are set to provide new opportunities for precision metrology and fundamental physics. Taking advantage of inherent low sensitivity of a nuclear transition to its environment, orders of magnitude more emitters can be hosted in a solid-state crystal compared with current optical lattice atomic clocks. Furthermore, solid-state systems needing only simple thermal control are key to the development of field-deployable compact clocks. Here we explore and characterize the frequency reproducibility of the 229 Th:CaF 2 nuclear clock transition, a key performance metric for all clocks. We measure the transition linewidth and centre frequency as a function of the doping concentration, temperature and time. We report the concentration-dependent inhomogeneous linewidth of the nuclear transition, limited by the intrinsic host crystal properties. We determine an optimal working temperature for the 229 Th:CaF 2 nuclear clock at 196(5) K, at which the first-order thermal sensitivity vanishes. This would enable in situ temperature co-sensing using different quadrupole-split lines, reducing the temperature-induced systematic shift below the 10 −18 fractional frequency uncertainty level. At 195 K, the reproducibility of the nuclear transition frequency is 220 Hz (fractionally 1.1 × 10 −13 ) for two differently doped 229 Th:CaF 2 crystals over 7 months. Furthermore, these results form the foundation for understanding, controlling and harnessing the coherent nuclear excitation of 229 Th in solid-state hosts and for their applications in constraining temporal variations of fundamental constants.

Atomic and molecular physics↗

Characterization of Cs vapor cell coated with octadecyltrichlorosilane using coherent population trapping spectroscopy

We report the realization and characterization using coherent population trapping (CPT) spectroscopy of an octadecyltrichlorosilane (OTS)-coated centimeter-scale Cs vapor cell. The dual-structure of the resonance lineshape, with presence of a narrow structure line at the top of a Doppler-broadened structure, is clearly observed. The linewidth of the narrow resonance is compared to the linewidth of an evacuated Cs cell and of a buffer gas Cs cell of similar size. The Cs-OTS adsorption energy is measured to be (0.42 ± 0.03) eV, leading to a clock frequency shift rate of 2.7 × 10{sup −9}/K in fractional unit. A hyperfine population lifetime, T{sub 1}, and a microwave coherence lifetime, T{sub 2}, of 1.6 and 0.5 ms are reported, corresponding to about 37 and 12 useful bounces, respectively. Atomic-motion induced Ramsey narrowing of dark resonances is observed in Cs-OTS cells by reducing the optical beam diameter. Ramsey CPT fringes are detected using a pulsed CPT interrogation scheme. Potential applications of the Cs-OTS cell to the development of a vapor cell atomic clock are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-site integrated optical addressing of trapped ions

Abstract One of the most effective ways to advance the performance of quantum computers and quantum sensors is to increase the number of qubits or quantum resources in the system. A major technical challenge that must be solved to realize this goal for trapped-ion systems is scaling the delivery of optical signals to many individual ions. In this paper we demonstrate an approach employing waveguides and multi-mode interferometer splitters to optically address multiple 171 Yb + ions in a surface trap by delivering all wavelengths required for full qubit control. Measurements of hyperfine spectra and Rabi flopping were performed on the E2 clock transition, using integrated waveguides for delivering the light needed for Doppler cooling, state preparation, coherent operations, and detection. We describe the use of splitters to address multiple ions using a single optical input per wavelength and use them to demonstrate simultaneous Rabi flopping on two different transitions occurring at distinct trap sites. This work represents an important step towards the realization of scalable integrated photonics for atomic clocks and trapped-ion quantum information systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Micro-fabricated mirrors with finesse exceeding one million

The Fabry–Perot resonator is one of the most widely used optical devices, enabling scientific and technological breakthroughs in diverse fields including cavity quantum electrodynamics, optical clocks, precision length metrology, and spectroscopy. Though resonator designs vary widely, all high-end applications benefit from mirrors with the lowest loss and highest finesse possible. Fabrication of the highest-finesse mirrors relies on centuries-old mechanical polishing techniques, which offer losses at the parts-per-million (ppm) level. However, no existing fabrication techniques are able to produce high-finesse resonators with the large range of mirror geometries needed for scalable quantum devices and next-generation compact atomic clocks. In this paper, we introduce a scalable approach to fabricate mirrors with ultrahigh finesse ( ≥ <#comment/> 10 6 ) and user-defined radius of curvature spanning of four orders of magnitude ( 10 − <#comment/> 4 − <#comment/> 10 0 m ). We employ photoresist reflow and reactive ion etching to shape and transfer mirror templates onto a substrate while maintaining sub-Angstrom roughness. This substrate is coated with a dielectric stack and used to create arrays of compact Fabry–Perot resonators with finesse values as high as 1.3 million and measured excess loss < <#comment/> 1 p p m . Optical ringdown measurements of 43 devices across five substrates reveal that the fabricated cavity mirrors—with both small and large radii of curvature—produce an average coating-limited finesse of 1.05 million. This versatile approach opens the door to scalable fabrication of high-finesse miniaturized Fabry–Perot cavities needed for emerging quantum optics and frequency metrology technologies.

42 ENGINEERING↗

A passion for precision

For more than three decades, the quest for ever higher precision in laser spectroscopy of the simple hydrogen atom has inspired many advances in laser, optical, and spectroscopic techniques, culminating in femtosecond laser optical frequency combs as perhaps the most precise measuring tools known to man. Applications range from optical atomic clocks and tests of QED and relativity to searches for time variations of fundamental constants. Recent experiments are extending frequency comb techniques into the extreme ultraviolet. Laser frequency combs can also control the electric field of ultrashort light pulses, creating powerful new tools for the emerging field of attosecond science.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

YbH + formation in an ytterbium ion trap

The trapped 171 Yb + ion is a promising candidate for portable atomic clock applications. However, with buffer-gas cooled ytterbium ions, the ions can be pumped into a low-lying 2 F 7 / 2 state or form YbH + molecules. These dark states reduce the fluorescence signal from the ions and can degrade the clock stability. In this work, we study the dynamics of the populations of the 2 F 7 / 2 state and YbH + molecules under different operating conditions of our 171 Yb + ion system. Our study indicates that 2 F 7 / 2 -state ions can form YbH + molecules through interactions with hydrogen gas. As observed previously, dissociation of YbH + is observed at wavelengths around 369 nm. We also demonstrate YbH+ dissociation using 405 nm light. Moreover, we show that the population in the dark states can be limited by using a single repump laser at 935 nm. Our study provides insights into the molecular formation in a trapped ion system.

74 ATOMIC AND MOLECULAR PHYSICS↗

Commercialization of microcavity plasma devices and arrays: Systems for VUV photolithography and nanopatterning, disinfection of drinking water and air, and biofilm deactivation for medical therapeutics

Abstract A little more than two decades after the introduction of the first microcavity plasma devices, a growing body of commercial products based on the remarkable properties of these low‐temperature, atmospheric plasmas is now available. Following a brief review of early microplasma lamp development, this article describes microplasma‐based devices and systems currently being manufactured for applications in photolithography, photopatterning, and other nanofabrication processes, such as atomic layer deposition, spectroscopic identification and analysis of materials (including wide bandgap crystals), the disinfection of drinking water in off‐grid communities, deactivating COVID‐19 and other pathogens in air and on surfaces in public spaces, and vacuum ultraviolet lamps for driving atomic clocks. The microplasma‐based treatment of otitis media in the human ear will also be discussed.

42 ENGINEERING↗

422 Million intrinsic quality factor planar integrated all-waveguide resonator with sub-MHz linewidth

High quality-factor (Q) optical resonators are a key component for ultra-narrow linewidth lasers, frequency stabilization, precision spectroscopy and quantum applications. Integration in a photonic waveguide platform is key to reducing cost, size, power and sensitivity to environmental disturbances. However, to date, the Q of all-waveguide resonators has been relegated to below 260 Million. Here, we report a Si 3 N 4 resonator with 422 Million intrinsic and 3.4 Billion absorption-limited Qs. The resonator has 453 kHz intrinsic, 906 kHz loaded, and 57 kHz absorption-limited linewidths and the corresponding 0.060 dB m -1 loss is the lowest reported to date for waveguides with deposited oxide upper cladding. These results are achieved through a careful reduction of scattering and absorption losses that we simulate, quantify and correlate to measurements. This advancement in waveguide resonator technology paves the way to all-waveguide Billion Q cavities for applications including nonlinear optics, atomic clocks, quantum photonics and high-capacity fiber communications.

36 MATERIALS SCIENCE↗

Cross-platform comparison of arbitrary quantum states

As we approach the era of quantum advantage, when quantum computers (QCs) can outperform any classical computer on particular tasks, there remains the difficult challenge of how to validate their performance. While algorithmic success can be easily verified in some instances such as number factoring or oracular algorithms, these approaches only provide pass/fail information of executing specific tasks for a single QC. On the other hand, a comparison between different QCs preparing nominally the same arbitrary circuit provides an insight for generic validation: a quantum computation is only as valid as the agreement between the results produced on different QCs. Such an approach is also at the heart of evaluating metrological standards such as disparate atomic clocks. In this paper, we report a cross-platform QC comparison using randomized and correlated measurements that results in a wealth of information on the QC systems. We execute several quantum circuits on widely different physical QC platforms and analyze the cross-platform state fidelities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum sensing for emerging energy technologies

The ability to exploit quantum phenomena has enabled sensing technologies with detection limits below the classical limit. Sensors with applications in energy discovery, production, transportation, and consumption can be enhanced through quantum or hybrid quantum-classical sensors. Here, in this Review, we provide an overview of commercial and emerging quantum sensor platforms and their opportunity areas specific to advanced energy technologies. Key examples include: power grid-enhancing-technologies, where quantum magnetometers can detect powerline and transformer faults; electric vehicle-to-grid applications, where chip-scale atomic clocks can enable grid synchronization; and carbon capture and storage, where quantum gravimeters and single-photo LiDAR can detect microscopic leaks. Quantum sensor deployment requires further research into miniaturization and ruggedization for field deployment, cost-reduction, and workforce development. The maturation of clean energy technologies and quantum sensors provide opportunities for synergy, with the integration of quantum sensors into advanced energy technologies maximizing their security, reliability, and efficiency.

critical metals↗

Fibre optics wavemeters calibration using a self-referenced optical frequency comb

Self-referenced optical frequency combs enable the measurement of optical frequencies with a very high accuracy, achieving uncertainties close to the atomic clock used as reference (<10{sup −13} s). In this paper, we present the technique for the measurement of laser frequencies for optical communications followed at IO-CSIC and its application to the calibration of two wavemeters in the 1.5 μm optical communication window. Calibration uncertainties down to 12 MHz and 59 MHz were obtained, respectively, for each of the devices. Furthermore, the long-term behaviour of the higher resolution wavemeter was studied during a 750 h period of sustained operation, exhibiting a dispersion in the measurements of 7.72 MHz. Temperature dependence of the device was analysed, enabling to further reduce dispersion down to a 2.15 MHz range, with no significant temporal deviations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photonic integration for UV to IR applications

Photonic integration opens the potential to reduce size, power, and cost of applications normally relegated to table- and rack-sized systems. Today, a wide range of precision, high-end, ultra-sensitive, communication and computation, and measurement and scientific applications, including atomic clocks, quantum communications, processing, and high resolution spectroscopy, are ready to make the leap from the lab to the chip. However, many of these applications operate at wavelengths not accessible to the silicon on insulator-based silicon photonics integration platform due to absorption, power handling, unwanted nonlinearities, and other factors. Next generation photonic integration will require ultra-wideband photonic circuit platforms that scale from the ultraviolet to the infrared and that offer a rich set of linear and nonlinear circuit functions as well as low loss and high power handling capabilities. This article provides an assessment of the field in ultra-wideband photonic waveguides to bring power efficient, ultra-high performance systems to the chip-scale and enable compact transformative precision measurement, signal processing, computation, and communication techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-loss low thermo-optic coefficient Ta 2 O 5 on crystal quartz planar optical waveguides

Optical resonator-based frequency stabilization plays a critical role in ultra-low linewidth laser emission and precision sensing, atom clocks, and quantum applications. However, there has been limited success in translating traditional bench-top stabilization cavities to compact on-chip integrated waveguide structures that are compatible with photonic integration. The challenge lies in realizing waveguides that not only deliver low optical loss but also exhibit a low thermo-optic coefficient and frequency noise stability. Given the problematic sources of frequency noise within dielectrics, such as thermorefractive noise, resonators with small thermo-optic response are desirable for on-chip reference cavities. We report the first demonstration of a Ta 2 O 5 (tantala) waveguide core fabricated on a crystal quartz substrate lower cladding with TEOS-PECVD SiO 2 upper cladding. This waveguide offers significant advantages over other waveguides in terms of its low thermo-optic coefficient and reduced thermorefractive-related frequency noise. We describe the waveguide structure and key design parameters as well as fabrication considerations for processing tantala on quartz waveguides. We report a waveguide thermo-optic coefficient of -1.14 × 10 -6 RIU/K, a value that is over 6 times smaller in magnitude than that of SiO 2 -substrate tantala waveguides, with a propagation loss of 1.19 dB/cm at 1550 nm and <1.33 dB/cm across the 1525 nm–1610 nm wavelength range. Within a 1.6 mm radius ring resonator, we demonstrate a 2.54 × 10 5 intrinsic Q factor. With the potential for very low loss and the ability to control the thermal response, this waveguide platform takes a key step toward creating thermally stable integrated resonators for on-chip laser frequency stabilization and other applications.

42 ENGINEERING↗

Efficient and tunable blue light generation using lithium niobate nonlinear photonics

Thin-film lithium niobate (LN) has recently emerged as a playground for chip-scale nonlinear optics and leads to efficient frequency conversions from near-infrared to near-visible bands. For many nonlinear and quantum photonics applications, it is desirable to operate deep into the visible band within LN's transparency window. However, the strong material dispersion at short wavelengths makes phase-matching difficult, necessitating sub-micrometer scale control of domain structures for efficient phase-matching. Here, we report the operation of thin film LN in the blue wavelength and high fidelity poling of the thin-film LN waveguide to this regime. As a result, quasi-phase matching is realized between IR (871 nm) and blue (435.5 nm) wavelengths in a straight waveguide and prompts strong blue light generation with a conversion efficiency (1040% ± 140%/W). This blue second harmonic generator exhibits stable temperature tunability, which is important for applications that require precise frequency alignment, such as atomic clocks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Isotope study of the nonlinear pressure shifts of 85 Rb and 87 Rb hyperfine resonances in Ar, Kr, and Xe buffer gases

Measurements of the 0–0 hyperfine resonant frequencies of ground-state 85 Rb atoms show a nonlinear dependence on the pressure of the buffer gases Ar, Kr, and Xe. The nonlinearities are similar to those previously observed with 87 Rb and 133 Cs and presumed to come from alkali-metal–noble-gas van der Waals molecules. However, the shape of the nonlinearity observed for Xe conflicts with previous theory, and the nonlinearities for Ar and Kr disagree with the expected isotopic scaling of previous 87 Rb results. Improving the modeling alleviates most of these discrepancies by treating rotation quantum mechanically and considering additional spin interactions in the molecules. Including the dipolar-hyperfine interaction allows simultaneous fitting of the linear and nonlinear shifts of both 85 Rb and 87 Rb in either Ar, Kr, or Xe buffer gases with a minimal set of shared, isotope-independent parameters. To the limit of experimental accuracy, the shifts in He and N 2 were linear with pressure. Further, the results are of practical interest to vapor-cell atomic clocks and related devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗