Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arc density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

On the emission mechanism in high current hollow cathode arcs

Large hollow cathodes have been operated in a magnetoplasmadynamic arc over wide ranges of current and mass flow, with orifice current densities and mass fluxes encompassing those encountered in low current steady state hollow cathode arcs. Detailed cathode interior measurements of current and potential distributions show that maximum current penetration into the cathode is about one diameter axially upstream from the tip, with peak inner surface current attachment up to one cathode diameter upstream of the tip. The spontaneous attachment of peak current upstream of the cathode tip is suggested as a criterion for characteristic hollow cathode operation. This empirical criterion was verified by experiment.

Krishnan, M.↗

Arc restrike in the rail accelerator

One of the causes of the degradation in rail accelerator performance is the formation of a secondary arc. Experimental evidence of arc restrike and the subsequent growth of this secondary arc is presented. A simple analytical treatment of arc restrike is developed in terms of breakdown of residual vapor atoms. It is found that after the passage of the primary arc, the bore volume contains a large number of residual neutral vapor atoms. If the density of these atoms is in excess of the critical density, then for a certain length of time the condition exists in the bore for the formation of a secondary arc. Evaporation of atoms from the bore surfaces cannot provide a sufficient number of atoms for an arc restrike. A likely source of the high residual atom density is the leakage of a portion of the ablated material that is added to the trailing edge of the primary arc.

Ray, Pradosh K.↗

High resolution >40 keV x-ray radiography using an edge-on micro-flag backlighter at NIF-ARC

Radiography of low-contrast features in high-density materials evolving on a nanosecond timescale requires a bright photon source in the tens of keV range with high temporal and spatial resolution. One application for sources in this category is the study of dynamic material strength in samples compressed to Mbar pressures at the National Ignition Facility, high-resolution measurements of plastic deformation under conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Here, we present radiographic data and the modulation transfer function (MTF) analysis of a multi-component test object probed at ~100 keV effective backlighter energy using a 5 μm-thin dysprosium foil driven by the NIF Advanced Radiographic Capability (ARC) short-pulse laser (~2 kJ, 10 ps). The thin edge of the foil acts as a bright line-projection source of hard x rays, which images the test object at 13.2× magnification into a filtered and shielded image plate detector stack. The system demonstrates a superior contrast of shallow (5 μm amplitude) sinusoidal ripples on gold samples up to 90 μm thick as well as enhanced spatial and temporal resolution using only a small fraction of the laser energy compared to an existing long-pulse-driven backlighter used routinely at the NIF for dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

Coordinated observations of the magnetosphere - The development of a substorm.

Coordinated observations of a substorm are reported by using data from all-sky camera (ASCA) stations near the northern conjugate of the ATS 5 geostationary satellite, plasma and magnetic-field experiments on the ATS 5 satellite, Vela 5B at 18 earth radii in the magnetotail, the Heos 1 interplanetary probe, and ground-based magnetograms. The substorm event occurred after a very quiet day and was preceded by a development period during which the interplanetary field turned southward and the plasma energy density increased near the earth on the nightside. This period was also evidenced by a depression of the midlatitude H component of the geomagnetic field at the earth's surface. The auroral breakup was preceded by the appearance of quiet arcs, the leveling off of the plasma energy density increase at ATS, and the disappearance of the tail plasma at 18 earth radii.

Mende, S. B.↗

Measurements of field-aligned currents in a multiple auroral arc system

A rocket-borne experiment to study the currents associated with a system of multiple auroral arcs was conducted at Poker Flat, Alaska, at 1122 UT on Feb. 2, 1972. The magnetic field in the vicinity of the auroral system was measured with a cesium vector magnetometer. Possible configurations were inferred by constructing model current systems that reproduced the magnetic field variations measured along the flight path. The data are interpreted in terms of a model current system consisting of two eastward electrojets and one westward electrojet and three pairs of oppositely directed Birkeland sheet currents, all lying in a plane approximately parallel to the auroral arcs. Sheet thicknesses ranged from 20 to 60 km and current densities from 10 to 45 microampere/sq m; the electrojet currents ranged from 1000 to 2000 A. A possible alternate model consisted of four pairs of sheets whose thicknesses range from 10 to 40 km with current densities from 10 to 90 microampere/sq m. There was quite good agreement between the locations of the visual arcs and the upward current sheets. The overall current configuration is discussed in view of the theoretical models constructed by Atkinson and Sato and Holzer and of other observations.

Sesiano, J.↗

Quasi-steady plasma acceleration.

A coaxial plasma accelerator driven by protracted pulses of current in the range of 10,000 to 100,000 A and synchronized mass flows from 1.0 to 36 g/sec argon attains, after some tens of microseconds, a stable magnetoplasmadynamic acceleration mode. This 'quasi-steady' discharge form is characterized by constant terminal voltage and current, a diffuse, fixed current distribution within the discharge, and a steady plasma efflux at velocities of approximately 20 km/sec. Measured potential distributions reveal that the bulk of the arc voltage gradient, exclusive of the electrode falls, occurs within two diameters of the cathode, and is normal to it. The anode fall voltage varies inversely with local current density, implying substantially lower anode losses at higher power arc operation. Spectroscopic, potential, and velocity measurements indicate the existence of a characteristic mass flow rate for a given current, below which arc operation becomes erratic.

Jahn, R. G.↗

The X-ray attenuation characteristics and density of human calcaneal marrow do not change significantly during adulthood

Changes in the material characteristics of bone marrow with aging can be a significant source of error in measurements of bone density when using X-ray and ultrasound imaging modalities. In the context of computed tomography, dual-energy computed techniques have been used to correct for changes in marrow composition. However, dual-energy quantitative computed tomography (DE-QCT) protocols, while increasing the accuracy of the measurement, reduce the precision and increase the radiation dose to the patient in comparison to single-energy quantitative computed tomography (SE-QCT) protocols. If the attenuation properties of the marrow for a particular bone can be shown to be relatively constant with age, it should be possible to use single-energy techniques without experiencing errors caused by unknown marrow composition. Marrow was extracted by centrifugation from 10 mm thick frontal sections of 34 adult cadaver calcanei (28 males, 6 females, ages 17-65 years). The density and energy-dependent linear X-ray attenuation coefficient of each marrow sample were determined. For purposes of comparing our results, we then computed an effective CT number at two GE CT/i scan voltages (80 and 120 kVp) for each specimen. The coefficients of variation for the density, CT number at 80 kVp and CT number at 120 kVp were each less than 1%, and the parameters did not change significantly with age (p > 0.2, r2 < 0.02, power > 0.8 where the minimum acceptable r2 = 0.216). We could demonstrate no significant gender-associated differences in these relationships. These data suggest that calcaneal bone marrow X-ray attenuation properties and marrow density are essentially constant from the third through sixth decades of life.

NASA Discipline Musculoskeletal↗

Exploratory development of a flexible ablative covering for space shuttle application

An applied research program is considered for a preliminary design and development of a flexible ablative covering for the space shuttle vehicle that could be easily replaced and/or refurbished. The program was structured to concentrate resources on the major technical problem areas associated with the flexible ablator concept. These areas included: (1) fabrication of a suitable woven carpet reinforcement, (2) modification of a flexible ablator formulation for filling the woven carpet construction, and (3) testing of the flexible ablator concept. Several approaches were evaluated to obtain a flexible ablator. The final recommended solution was one in which the ablative filler was based on a low-density formulation of the elastomeric shield material series (ESM). The preferred approach is one in which a light-weight fabric backing is bonded to preformed and fully cured ESM, and the composite tufted with Astroquartz fiber to the desired tuft or pile density. Ablation tests performed in a hyperthermal arc facility demonstrated the ablation performance of the concept and overshoot capability of the system.

Hiltz, A. A.↗

Exhaust flow and propulsion characteristics of a pulsed MPD arc thruster.

Experimental investigation of the near-field, megawatt, single-shot exhaust for the self-field and auxiliary field cases (0 to 2 tesla) for a pulsed MPD arc thrustor. Plasma impact pressure and number density are correlated to provide velocity profiles (30,000 to 70,000 m/sec), thrust (10 to 120 N), impulse (3 to 16 N-sec) and mass accounting. The data agree with Hugel's self-field theory for the case where thrust is produced entirely by electromagnetic force. The data show that the thrust monotonically increases with auxiliary field.

Michels, C. J.↗

Ablative thermal protection for space tug multipass, aerobraking entry

Analytical studies had found the employment of an aerobraking trajectory for return of a reusable Space Tug from geosynchronous missions to be feasible and practical. To establish the minimum-weight ablative dome heat shield, trajectories involving 2 and 30 perigee passes were investigated both analytically and by plasma arc testing. Silicone-base ablators with densities of 15, 30, and 50 lb/cu ft were selected for evaluation. All models withstood the multipass exposures without deleterius surface recession or char erosion. Dome heat shield weights based on optimum ablative compositions indicated that ablators are a highly efficient thermal protection system for these missions.

Strauss, E. L.↗

Detection of a compact radio source near the center of a gravitational lens - Quasar image or galactic core

By use of a new, very sensitive interferometric system, a faint, compact radio source has been detected near the center of the galaxy that acts as the main part of a gravitational lens. This lens forms two previously discovered images of the quasar Q0957+561, which lies in the direction of the constellation Ursa Major. The newly detected source has a core smaller than 0.002 arc second in diameter with a flux density of 0.6 + or - 0.1 millijansky at the 13-centimeter wavelength of the radio observations. This source could be the predicted third image of the transparent gravitational lens, the central core of the galaxy, or some combination of the two. It is not yet possible to choose reliably between these alternatives.

Gorenstein, M. V.↗

Transition from ring to beam arc distributions of water ions near the Space Shuttle orbiter

The distribution function of water ions produced near the Space Shuttle by charge exchange between ionospheric oxygen ions and outgassed water molecules is studied. The transition from a ring to a beam arc distribution function is described. The number density of water ions is found to increase monotonically with decreasing distance from the Shuttle.

Cairns, Iver H.↗

An unusual SAR arc observed during ring current development, 4 August 1972

An unusual SAR arc observed during the growth phase of the ring current is described. Proton precipitation was observed, with electron temperature enhancements throughout the region, and an F-region trough present at the equatorward boundary; a high flux of low energy at the SAR arc location and a 'slot' in the ambient electron density are characteristic of this event. Comparisons are made with S3-A spacecraft observations made in the equatorial region at the same time and with Isis-II observations of a more normal SAR arc; the kinetic Alfven process described by Hasegawa and Mima (1978) appears to account for the acceleration of these low energy electrons, although an auroral-type acceleration process cannot be excluded.

Shepherd, G. G.↗

NASA GRC and MSFC Space-Plasma Arc Testing Procedures

Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. Discussed herein are neutral gas conditions, plasma densities and uniformity, vacuum chamber sizes, sample sizes and Debye lengths, biasing samples versus self-generated voltages, floating samples versus grounded samples, test electrical conditions, arc detection, preventing sustained discharges during testing, real samples versus idealized samples, validity of LEO tests for GEO samples, extracting arc threshold information from arc rate versus voltage tests, snapover, current collection, and glows at positive sample bias, Kapton pyrolysis, thresholds for trigger arcs, sustained arcs, dielectric breakdown and Paschen discharge, tether arcing and testing in very dense plasmas (i.e. thruster plumes), arc mitigation strategies, charging mitigation strategies, models, and analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

Ferguson, Dale C.↗

Electrical Breakdown of Anodized Structures in a Low Earth Orbital Environmental

A comprehensive set of investigations involving arcing on a negatively biased anodized aluminum plate immersed in a low density argon plasma at low pressures (P(sub O), 7.5 x 10(exp -5) Torr) have been performed. These arcing experiments were designed to simulate electrical breakdown of anodized coatings in a Low Earth Orbital (LEO) environment. When electrical breakdown of an anodized layer occurs, an arc strikes, and there is a sudden flux of electrons accelerated into the ambient plasma. This event is directly followed by ejection of a quasi-neutral plasma cloud consisting of ejected material blown out of the anodized layer. Statistical analysis of plasma cloud expansion velocities have yielded a mean propagation velocity, v = (19.4 +/- 3.5) km/s. As the plasma cloud expands into the ambient plasma, energy in the form of electrical noise is generated. The radiated electromagnetic noise is detected by means of an insulated antenna immersed in the ambient plasma. The purpose of the investigations is (1) to observe and record the electromagnetic radiation spectrum resulting from the arcing process. (2) Make estimates of the travel time of the quasi-neutral plasma cloud based on fluctuations to several Langmuir probes mounted in the ambient plasma. (3) To study induced arcing between two anodized aluminum structures in close proximity.

Galofaro, J. T.↗

Brightness, density, and color profiles of three globular clusters - NGC 6440, 6541, and 7099

Using short-exposure SEC television camera observations, the radial distribution profiles of surface brightness, B-V colors and star densities are determined in three globular clusters, NGC 6440, 6541 and 7099, from about 2-200 arc sec from the cluster centers. Good agreement is found between the surface-brightness profiles and the star-density distributions; both can be fitted well with a King-type curve, and no significant evidence for a presence of cusp at r greater then 3 arc sec is observed. Also determined for the three clusters were central surface brightnesses, core radii, central mass densities, total cluster masses, relaxation times and central escape velocities. In addition, an upper limit of 5000 solar masses is placed on the mass of a possible central black hole in these clusters.

Williams, T. B.↗