Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical detection method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Real-Time Health Monitoring for Gas Turbine Components Using Online Learning and High-Dimensional Data

Capital-intensive turbomachinery, such as gas turbines and combined cycle plants, are constantly being monitored for performance anomalies, faults, and physical degradation. Although these power-generating assets are equipped with hundreds of sensors, existing monitoring tools can only handle moderate-sized data. As a result, only a handful of aggregate metrics are used to monitor machine health. At the same time, developing advanced tools suitable for large datasets have been restricted by the lack of appropriate data. The objective of this proposal was to demonstrate a Big Data analytics framework for fault detection and diagnosis in gas turbine applications. We develop a predictive analytics framework methodology guided by these experimental data, industrial data from our collaborators, and physics-based models with engineering domain knowledge. Our analytics framework consists of four key components (1) a data curation process that addresses data storage, data quality assessments, and integrity checks, (2) a feature engineering component that utilizes statistical methods and transformation algorithms guided by physics-based models to extract high-fidelity fault features that can be leveraged for fault detection and classifying fault severities, (3) a Machine Learning-based fault detection and diagnostics algorithms for detecting operational and hardware faults in the combustion and the turbines section. We utilize two industry-class gas turbine component test rigs to generate first of its kind data for critical gas turbine faults with varying severity levels. Advanced gas turbine test facilities will be interrogated using state-of-the-art instrumentation techniques to build fault signatures and data trends for key combustor and turbine faults. Data generated from a combustor test rig (Georgia Tech) and a turbine test rig (Penn State) during both normal operation and with seeded faults serve as the basis for the Big Data sets. The test conditions in the two test facilities include common, critical events that occur in the operation. Utilizing the combustor test rig, we examine two common combustor faults: lean blowout and centerbody degradation. For the turbine section we develop analytic models for monitoring cooling faults in the gas turbine

03 NATURAL GAS↗

Real-Time Health Monitoring for Gas Turbine Components Using Online Learning and High-Dimensional Data (Final Report)

Capital-intensive turbomachinery, such as gas turbines and combined cycle plants, are constantly being monitored for performance anomalies, faults, and physical degradation. Although these power-generating assets are equipped with hundreds of sensors, existing monitoring tools can only handle moderate-sized data. As a result, only a handful of aggregate metrics are used to monitor machine health. At the same time, developing advanced tools suitable for large datasets have been restricted by the lack of appropriate data. The objective of this proposal was to demonstrate a Big Data analytics framework for fault detection and diagnosis in gas turbine applications. We develop a predictive analytics framework methodology guided by these experimental data, industrial data from our collaborators, and physics-based models with engineering domain knowledge. Our analytics framework consists of four key components: (1) a data curation process that addresses data storage, data quality assessments, and integrity checks, (2) a feature engineering component that utilizes statistical methods and transformation algorithms guided by physics-based models to extract high-fidelity fault features that can be leveraged for fault detection and classifying fault severities, (3) a Machine Learning-based fault detection and diagnostics algorithms for detecting operational and hardware faults in the combustion and the turbines section. We utilize two industry-class gas turbine component test rigs to generate first of its kind data for critical gas turbine faults with varying severity levels. Advanced gas turbine test facilities will be interrogated using state-of-the-art instrumentation techniques to build fault signatures and data trends for key combustor and turbine faults. Data generated from a combustor test rig (Georgia Tech) and a turbine test rig (Penn State) during both normal operation and with seeded faults serve as the basis for the Big Data sets. The test conditions in the two test facilities include common, critical events that occur in the operation. Utilizing the combustor test rig, we examine two common combustor faults: lean blowout and centerbody degradation. For the turbine section we develop analytic models for monitoring cooling faults in the gas turbine.

20 FOSSIL-FUELED POWER PLANTS↗

Model‐Based Approach to Selecting Pegfilgrastim Dose for Pharmacokinetic and Pharmacodynamic Similarity Studies in Biosimilar Development

This study applied modeling and simulation (M&S) approaches to evaluate the sensitivity of pegfilgrastim pharmacokinetics (PKs) and pharmacodynamics (PDs) to changes in dose amount, and linear or nonlinear clearance (CL) over pegfilgrastim subcutaneous dose of 2–6 mg. A previously published model was adapted to better describe pegfilgrastim PK and PD data in healthy subjects and used in simulation. Nonlinear CL accounts for 98% and 77%, respectively, of the total CL of pegfilgrastim at 2 and 6 mg. The sensitivity analyses showed: (i) PK of 2 and 6 mg doses are similarly sensitive to detect differences for a 5% change in dose; (ii) PK of 2 mg dose is more sensitive to changes in receptor binding affinity, a model parameter for nonlinear CL, and a product quality attribute characterized with orthogonal methods as part of demonstrating analytical similarity between products; (iii) PK of approved 6 mg dose is more sensitive to changes in linear CL, which has not been associated with any specific product quality attributes, and (iv) the PDs are not sensitive to changes in linear or nonlinear CL. Taken together, our analyses support that the approved pegfilgrastim dose of 6 mg is appropriate for detecting differences between a biosimilar and the reference products in pegfilgrastim PK and PD similarity studies. The described M&S approaches can be adopted to support dose selection for biosimilars with nonlinear PK and complex PK–PD interplay.

Pharmacology & Pharmacy↗

Use of Fluorescent Protein Reporters for Assessing and Detecting Genome Editing Reagents and Transgene Expression in Plants

Fluorescent protein reporters have been widely used for monitoring the expression of target genes in various engineered organisms. Although a wide range of analytical approaches (e.g., genotyping PCR, digital PCR, DNA sequencing) have been utilized to detect and identify genome editing reagents and transgene expression in genetically modified plants, these methods are usually limited to use in the late stages of plant transformation and can only be used invasively. Here we describe GFP- and eYGFPuv-based strategies and methods for assessing and detecting genome editing reagents and transgene expression in plants, including protoplast transformation, leaf infiltration, and stable transformation. These methods and strategies enable easy, noninvasive screening of genome editing and transgenic events in plants.

Yuan, Guoliang↗

Event-Based Analysis of Solar Power Distribution Feeder Using Micro-PMU Measurements

Solar distribution feeders are commonly used in solar farms that are integrated into distribution substations. In this paper, we focus on a real-world solar distribution feeder and conduct an event-based analysis by using micro-PMU measurements. The solar distribution feeder of interest is a behind-the-meter solar farm with a generation capacity of over 4 MW that has about 200 low-voltage distributed photovoltaic (PV) inverters. The event-based analysis in this study seeks to address the following practical matters. First, we conduct event detection by using an unsupervised machine learning approach. For each event, we determine the event’s source region by an impedancebased analysis, coupled with a descriptive analytic method. We segregate the events that are caused by the solar farm, i.e., locallyinduced events, versus the events that are initiated in the grid, i.e., grid-induced events, which caused a response by the solar farm. Second, for the locally-induced events, we examine the impact of solar production level and other significant parameters to make statistical conclusions. Third, for the grid-induced events, we characterize the response of the solar farm; and make comparisons with the response of an auxiliary neighboring feeder to the same events. Fourth, we scrutinize multiple specific events; such as by revealing the dynamics to the control system of the solar distribution feeder. The results and discoveries in this study are informative to utilities and solar power industry.

14 SOLAR ENERGY↗

Validation of Computational Fluid Dynamics Simulations for Biological Performance Assessment in Hydropower units (Final Report)

The biological performance assessment (BioPA) toolset developed by Pacific Northwest National Laboratory (PNNL) estimates the relative biological performance of fish passage at a hydroelectric power turbine unit. The tool is based on the use of computational fluid dynamics (CFD) and fish biological response relationships. The recent release, BioPA-v3, is based on directly computed trajectory and collision of material Lagrangian particles using CFD simulation codes rather than the prior version that relies on Tecplot to compute streamtrace trajectories. Before modifying the toolset, a series of validation tests were performed at the various steps of modification in the toolset. Validation is a critical step of any numerical investigation that reflects the accuracy and reliability of the predicted results. It raises the confidence level of the user to use the modified version of the BioPA toolset. Several test cases were simulated and compared, where available, to observed data. The trajectory and collision of the small spherical and cylindrical particles in a water flume were compared to in-house experiments. The CFD predicted collision rate and flow field compared well with experimental observation for vane array and large cylinder as target bodies. Next, the CFD-predicted flow field and hydraulic performance of a laboratory-scale model of a Francis turbine was also successfully validated. Note that the trajectory of the particles is significantly affected by the flow field in such extreme conditions. In addition to the particle trajectories and flow field, the collision detection method employed in the CFD simulations was also successfully validated. The CFD predicted impact velocity, collision time, velocity, and trajectory of a sphere excellently matched with analytical value for a bouncing ball in the elastic collision. A similar approach was also tested and successfully validated for a collision of sphere with a 45° inclined plane. After successfully validating different cases, the BioPA toolset was modified to use direct output of the CFD prediction and the new version can be used in evaluating biological performance at hydroelectric turbines.

13 HYDRO ENERGY↗

Detecting the undetected: Dealing with non-routine events using advanced M&V meter-based savings approaches

In a rapidly evolving energy industry, utilities are dealing with new challenges like integrating distributed energy resources and market saturation for advanced lighting retrofits. Demand-side management programs require new approaches to meet aggressive carbon reduction goals. Advanced measurement & verification (M&V) is an energy data analysis method using smart meter data in combination with analytics to quantify energy efficiency project savings. Advanced M&V shows great promise for supporting next generation commercial programs including retro commissioning, multi-measure retrofits, and behavior change programs. Advanced M&V captures real project impacts at the meter, but sometimes non-project events can also impact consumption (so-called “non-routine events” [NREs]). Accurately detecting and accounting for NREs is important for reducing uncertainty of savings estimates and helps manage investment risk for different stakeholders (e.g., utilities, building owners, ESCOs). Recent research has shown promise in establishing data-driven techniques to identify and adjust for NREs, but fundamental questions still remain, such as: how can you distinguish NREs from acceptable noise in energy consumption profiles? What is the frequency and magnitude of NREs? Can their detection and adjustment be automated and streamlined? This paper documents the state of the art in NRE quantification and analysis. The results of research to quantify the frequency, nature and direction of NREs, and methods and metrics for determining a trigger threshold for taking action on NREs are presented. The paper also documents the latest technical guidance on application of NRE detection and adjustment methods.

Fernandes, Samuel↗

Establishment of time‐resolved fluoroimmunoassay of IgG4 based on magnetic microspheres

Abstract Background The abnormal increase in serum IgG4 level is an important clinical symptom of IgG4‐related disease (IgG4‐RD), and the detection of serum IgG4 level is a powerful tool for the diagnosis of IgG4‐RD. This study was conducted to establish a simple and rapid immunoassay for the determination of human serum IgG4 levels. Methods Based on the competition method, a novel immunoassay was established for the determination of human serum IgG4 using a combination of time‐resolved fluoroimmunoassay (TRFIA) and magnetic microspheres. IgG4 was coupled with magnetic microspheres and competed with IgG4 in the samples to bind the Eu 3+ ‐labeled anti‐IgG4 antibody. The immunocomplex was separated and washed in a magnetic field, and the fluorescence counts were measured according to the number of dissociated europium ions. Results The analytical sensitivity of IgG4‐TRFIA based on magnetic microspheres was 0.006 g/L, and the detection range was 0.006–20 g/L under optimal conditions. The precision, recovery, and specificity of this immunoassay were demonstrated to be acceptable. The clinical application of IgG4‐TRFIA based on magnetic microspheres was evaluated and compared with that of immunonephelometry. The results showed that the two detection methods had a good correlation, with a correlation coefficient of .9871. Conclusion IgG4‐TRFIA based on magnetic microspheres has the advantages of high sensitivity, wide detection range, and short analysis time and has the potential to become a useful tool for the diagnosis of IgG4‐RD.

Wu, Qingqing↗

Quantitative Separation of Unknown Organic–Metal Complexes by Liquid Chromatography–Inductively Coupled Plasma-Mass Spectrometry

Dissolved organic matter (DOM) is widely recognized to control the solubility and reactivity of trace metals in the environment. However, the mechanisms that govern metal-DOM complexation remain elusive, primarily due to the analytical challenge of fractionating and quantifying metal–organic species within the complex mixture of organic compounds that comprise DOM. Here, we describe a quantitative method for fractionation and element-specific detection of organic–metal complexes using liquid chromatography with online inductively coupled plasma mass spectrometry (LC–ICP-MS). The method implements a post-column compensation gradient to stabilize ICP–MS elemental response across the LC solvent gradient, thereby overcoming a major barrier to achieving quantitative accuracy with LC–ICP-MS. With external calibration and internal standard correction, the method yields concentrations of organic–metal complexes that were consistently within 6% of their true values, regardless of the complex’s elution time. We used the method to evaluate the effects of four stationary phases (C18, phenyl, amide, and pentafluoroylphenyl propyl) on the recovery and separation of environmentally relevant trace metals (Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in Suwannee River Fulvic Acid and Suwannee River Natural Organic Matter. The C18, amide, and phenyl phases generally yielded optimal metal recoveries (>75% for all metals except Pb), with the phenyl phase separating polar species to a greater extent than C18 or amide. We also fractionated organic-bound Fe, Cu, and Ni in oxidized and reduced soils, revealing divergent metal-DOM speciation across soil redox environments. Finally, by enabling quantitative fractionation of DOM-bound metals, our method offers a means for advancing a mechanistic understanding of metal–organic complexation throughout the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intelligent Electrochemical Sensors for Precise Identification of Volatile Organic Compounds Enabled by Neural Network Analysis

The volatile organic compounds (VOCs) in a wide spectrum of categories were identified as biomarkers in aquatic environments, playing an important role in marine and freshwater ecology and global atmospheric chemistry. VOCs released from biofuel have also attracted increasing attention. Although the importance has been recognized, the portable detection and analysis methods of VOC in aquatic systems have not yet been well developed and understood. Here, in this work, we innovatively proposed an intelligent electrochemical sensing approach to classify and quantify VOCs in solution. Utilizing the cyclic voltammetry (CV) method with an ionic liquid (IL)-based electrolyte, we analyzed 50 μL samples of various VOC analytes, including acetic acid (AC), acetone, dimethylformamide (DMF), dimethyl sulfoxide (DMSO), ethanol, formaldehyde, formic acid, methanol, methyl formate (MF), toluene, and a formaldehyde-methanol mixture, along with deionized water (DI water). The generated voltammograms were subsequently analyzed using our uniquely designed and optimized 1-D convolutional neural network (1D-CNN). This deep-learning algorithm achieved a 99.09% accuracy in VOC classification validated through fivefold cross-validation and demonstrated an impressive 94.4% test accuracy for methanol detection within a 10 μL error range. For quantification, the system accurately categorized methanol volumes ranging from 0 to 50 μL in 10 μL increments, achieving a 98.18% accuracy. A notable linear correlation (R2 = 95.56%) was found between max current density at the oxidation peak and methanol volume, with the limit of detection (LOD) at 9.3 μL. Such a sensing method exhibits potential for portability, high accuracy, and generalization in the classification and quantification, ultimately reshaping the realm of VOC analysis in solution.

42 ENGINEERING↗

Dislocation dynamics in polycrystalline materials

An extension of the dislocation dynamics method to polycrystalline materials is presented with emphasis on handling interactions between dislocations and grain boundaries. The key new features of the method include: (1) a grain boundary detection algorithm, (2) new dislocation emission criteria based on power dissipation and area growth, (3) mobility of dislocations at grain boundaries, and (4) extension of topological operations e.g. mesh adaption, collision, and dissociation to handle dislocations interacting with grain boundaries. Furthermore, verification and validation examples are executed to compare our calculations with existing analytic methods, molecular dynamics simulations, and experimental observations.

36 MATERIALS SCIENCE↗

Fe Kα XANES, Fe Kβ HERFD XANES and EPMA flank method determinations of the oxidation state of Fe in garnet

The ferric to total iron ratios (Fe 3+ /ΣFe) of garnets can be paired with thermodynamic mineral activity models to quantify the oxygen fugacity of garnet-bearing rocks. However, techniques with a high analytical and spatial resolution are necessary to distinguish differences in garnet Fe 3+ /ΣFe ratios at the percent level and to accurately measure garnets that are zoned or contain inclusions. We acquired conventional Fe Kα and high-resolution energy fluorescence detection (HERFD) Fe Kβ X-ray absorption near edge structure (XANES) spectra and electron microprobe flank method analyses on a suite of 27 peridotitic and eclogitic garnets with Fe 3+ /ΣFe ratios previously determined by Mössbauer spectroscopy to evaluate the precision of each technique. We examined variations in the energy and intensity of three XANES spectral features as a function of Fe 3+ /ΣFe ratios: 1) the intensity ratio of two-post edge features (I-ratio; Fe Kα only); 2) the energy of the Fe edge at 90% normalized intensity (E 0.9 ; Fe Kα only) and 3) the pre-edge centroid energy (Fe Kα and HERFD Fe Kβ). In accordance with previous work, we find the energies of garnet pre-edge centroids are relatively insensitive to Fe 3+ /ΣFe ratios. The I-ratios of peridotitic and eclogitic garnets are offset from each other at low Fe 3+ /ΣFe ratios (≤0.13); I-ratio garnet XANES calibrations are composition-specific. The E 0.9 feature is independent of garnet major element composition in spectra that have been corrected for the effects of self-absorption. We produce two Fe Kα garnet XANES calibrations based on variations in the E0.9 feature; one calibration with all garnet reference materials included (Fe 3+ /ΣFe up to 1.0; “all garnet calibration”) and another calibration specific to garnets with low Fe 3+ /ΣFe ratios (“low ferric calibration”). Fe 3+ /ΣFe ratios calculated from the mean of up to 25 flank method measurements on eight garnet reference materials fall within 4% absolute of a one-to-one correlation with Fe 3+ /ΣFe ratios measured by Mössbauer. The standard error of the mean Fe 3+ /ΣFe ratio calculated from flank method approaches the Mössbauer-determined Fe 3+ /ΣFe ratio within estimated error (3%) after three analyses. Flank method precision is enhanced at higher beam current; however, the precision of the flank method does not approach the precision of XANES under any microprobe analytical condition tested here. Garnet reference materials detailed here are available by request to the Smithsonian Institution.

58 GEOSCIENCES↗

Resolving SPARC–HSA binding kinetics with an ultrasensitive photonic sensor based on bound states in the continuum

Secreted protein acidic and rich in cysteine (SPARC) is critical in cell-matrix interactions and tissue remodeling. It influences tumor progression through its affinity for human serum albumin (HSA) - the most abundant plasma protein, which also plays a crucial role in drug delivery. Strong molecular binding leads to a dissociation constant KD in the nanomolar range. Thus, determining KD requires detecting sub-nanomolar concentrations with ultrasensitive methods. This may be crucial for elucidating the nature of SPARC-HSA binding, as their interaction remains a subject of debate. Capturing these interactions accurately requires a platform capable of resolving rapid binding kinetics at extremely low analyte concentrations. In this work, we report on a microfluidics-integrated photonic nanostructure that supports bound states in the continuum (BICs) and is optimized for studying the fast kinetics of high-affinity protein-protein interactions. The unprecedented capability of detecting sub-nanomolar concentrations allows quantifying KD between SPARC and HSA beyond the state of the art. We leverage an all-dielectric photonic crystal slab (PhCS) sustaining two BIC branches arising from gapped Dirac cone dispersion. HSA is covalently immobilized on the PhCS bonded to a PDMS microfluidic chamber. SPARC dissociation is carried out using PBS buffer (pH 7.4), ensuring complete protein release through precise control of the flow rate and continuous spectral monitoring of the BICs. The measured KD=8.2±0.8 nM confirms the strong affinity of SPARC for HSA. This study highlights the potential of BIC-based sensing as a versatile tool for investigating protein interactions. These results also have implications for the optimization of drug delivery systems and cancer treatment strategies.

Albumin↗

A standardized quantitative analysis strategy for stable isotope probing metagenomics

ABSTRACT Stable isotope probing (SIP) facilitates culture-independent identification of active microbial populations within complex ecosystems through isotopic enrichment of nucleic acids. Many DNA-SIP studies rely on 16S rRNA gene sequences to identify active taxa, but connecting these sequences to specific bacterial genomes is often challenging. Here, we describe a standardized laboratory and analysis framework to quantify isotopic enrichment on a per-genome basis using shotgun metagenomics instead of 16S rRNA gene sequencing. To develop this framework, we explored various sample processing and analysis approaches using a designed microbiome where the identity of labeled genomes and their level of isotopic enrichment were experimentally controlled. With this ground truth dataset, we empirically assessed the accuracy of different analytical models for identifying active taxa and examined how sequencing depth impacts the detection of isotopically labeled genomes. We also demonstrate that using synthetic DNA internal standards to measure absolute genome abundances in SIP density fractions improves estimates of isotopic enrichment. In addition, our study illustrates the utility of internal standards to reveal anomalies in sample handling that could negatively impact SIP metagenomic analyses if left undetected. Finally, we present SIPmg , an R package to facilitate the estimation of absolute abundances and perform statistical analyses for identifying labeled genomes within SIP metagenomic data. This experimentally validated analysis framework strengthens the foundation of DNA-SIP metagenomics as a tool for accurately measuring the in situ activity of environmental microbial populations and assessing their genomic potential. IMPORTANCE Answering the questions, “who is eating what?” and “who is active?” within complex microbial communities is paramount for our ability to model, predict, and modulate microbiomes for improved human and planetary health. These questions can be pursued using stable isotope probing to track the incorporation of labeled compounds into cellular DNA during microbial growth. However, with traditional stable isotope methods, it is challenging to establish links between an active microorganism’s taxonomic identity and genome composition while providing quantitative estimates of the microorganism’s isotope incorporation rate. Here, we report an experimental and analytical workflow that lays the foundation for improved detection of metabolically active microorganisms and better quantitative estimates of genome-resolved isotope incorporation, which can be used to further refine ecosystem-scale models for carbon and nutrient fluxes within microbiomes.

54 ENVIRONMENTAL SCIENCES↗

Fast estimation of the look-elsewhere effect using Gaussian random fields

Abstract We discuss the use of Gaussian random fields to estimate the look-elsewhere effect correction. We show that Gaussian random fields can be used to model the null-hypothesis significance maps from a large set of statistical problems commonly encountered in physics, such as template matching and likelihood ratio tests. Some specific examples are searches for dark matter using pixel arrays, searches for astronomical transients, and searches for fast-radio bursts. Gaussian random fields can be sampled efficiently in the frequency domain, and the excursion probability can be fitted with these samples to extend any estimation of the look-elsewhere effect to lower p values. In addition, in cases where the Gaussian random field is stationary and the parameter space is Euclidean, the look-elsewhere effect correction can be computed analytically. We demonstrate these methods using two example template matching problems. Finally, we apply these methods to estimate the trial factor of a $$4^3$$ 4 3 accelerometer array for the detection of dark matter tracks in the Windchime project. When a global significance of $$3\sigma $$ 3 σ is required, the estimated trial factor for such an accelerometer array is $$10^{14}$$ 10 14 for a one-second search, and $$10^{22}$$ 10 22 for a 1-year search.

Qin, Juehang (ORCID:0000000182288949)↗

Explainable AI for Multivariate Time Series Pattern Exploration: Latent Space Visual Analytics With Temporal Fusion Transformer and Variational Autoencoders in Power Grid Event Diagnosis

Detecting and analyzing complex patterns in multivariate time-series data is crucial for decision-making in urban and environmental system operations. However, challenges arise from the high dimensionality, intricate complexity, and interconnected nature of complex patterns, which hinder the understanding of their underlying physical processes. Existing AI methods often face limitations in interpretability, computational efficiency, and scalability, reducing their applicability in real-world scenarios. This paper proposes a novel visual analytics framework that integrates two generative AI models, Temporal Fusion Transformer (TFT) and Variational Autoencoders (VAEs), to reduce complex patterns into lower-dimensional latent spaces and visualize them in 2D using dimensionality reduction techniques such as PCA, t-SNE, and UMAP with DBSCAN. These visualizations, presented through coordinated and interactive views and tailored glyphs, enable intuitive exploration of complex multivariate temporal patterns, identifying patterns’ similarities and uncover their potential correlations for a better interpretability of the AI outputs. The framework is demonstrated through a case study on power grid signal data, where it identifies multi-label grid event signatures, including faults and anomalies with diverse root causes. Additionally, novel metrics and visualizations are introduced to validate the models and assess the performance, efficiency, and consistency of latent maps generated by VAE, which have been utilized in prior studies for latent space cartography and used as a benchmark in this study, and the emerging TFT architecture under various configurations. These analyses provide actionable insights for model parameter tuning and reliability improvements. Comparative results highlight that TFT achieves shorter run times and superior scalability to diverse time-series data shapes compared to VAE. This work advances fault diagnosis in multivariate time series, fostering explainable AI to support critical system operations.

Explainable AI↗

Direct Measurements of Dimethyl Sulfide Oxidation Chemistry: Uncovering the Primary Pathways from Gas Phase to Sulfate Aerosols

We report experimental measurements of dimethyl sulfide oxidation, focusing on a major chemical intermediate, hydroperoxymethyl thioformate (HPMTF). The (photo)chemistry and transport properties of HPMTF, which are critical to accurate modeling of tropospheric sulfur, are not known, partly because current analytical methods are not optimized for elusive chemical intermediates. We investigated dimethyl sulfide oxidation using a custom time-resolved photoionization mass spectrometer, interfaced with pulsed laser photolysis, continuous photolysis, and liquid droplet reactors. We detected and characterized HPMTF (along with other reaction intermediates), quantified its yield, and measured its formation rate coefficient. We also developed a clean, intense, online HPMTF source, suitable for further experimental investigations. Lastly, we measured the mass accommodation coefficient of HPMTF on water droplets – a critical quantity for modeling its atmospheric partitioning between the gas and condensed phases. The experimental platform we developed here enables the exploration of other critical elusive reaction intermediates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hyperstealth dark matter and long-lived particles

A new dark matter candidate is proposed that arises as the lightest baryon from a confining 𝑆⁢𝑈⁡(𝑁) gauge theory which equilibrates with the Standard Model only through electroweak interactions. Surprisingly, this candidate can be as light as a few GeV. The lower bound arises from the intersection of two competing requirements: (i) the equilibration sector of the model must be sufficiently heavy, at least several TeV, to avoid bounds from colliders, and (ii) the lightest dark meson (that may be the dark 𝜂′, 𝜎, or the lightest glueball) has suppressed interactions with the SM and must decay before big bang nucleosynthesis. The low-energy dark sector consists of one flavor that is electrically neutral and an almost electroweak singlet. The dark matter candidate is the lightest baryon consisting of 𝑁 of these light flavors leading to a highly suppressed elastic scattering rate with the Standard Model (SM). The equilibration sector consists of vectorlike dark quarks that transform under the electroweak group, ensuring that the dark sector can reach thermal equilibrium with the SM in the early Universe. The lightest dark meson lifetimes vary between 10 −3 ≲ 𝑐⁢𝜏 ≲ 10 7 m, providing an outstanding target for LHC production and experimental detection. We delineate the interplay between the lifetime of the light mesons, the suppressed direct detection cross section of the lightest baryon, and the scale of equilibration sector that can be probed at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗