Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “alternating current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Analog/Digital System for Germanium Thermometer

Electronic system containing analog and digital circuits makes high-precision, four-wire measurements of resistance of each germanium resistance thermometer (GRT) in array of devices, using alternating current (ac) of 1 micro-A. At end measurement interval, contents of negative register subtracted from positive one, resulting in very-narrow-band synchronous demodulation of carrier wave and suppression of out-of-band noise. Microprocessor free to perform other duties after measurement complete. Useful in noisy terrestrial environments encountered in factories.

Woodhouse, Christopher↗

The application of high temperature superconductors to space electrical power distribution components

Some important space based electrical power distribution systems and components are examined to determine what might be achieved with the introduction of high temperature superconductors (HTS). Components that are compared in a before and after fashion include transformers, transmission lines, and capacitors. It is concluded that HTS has its greatest effect on the weight associated with transmission lines, where the weight penalty could be reduced by as much as 130 kg/kW/km of cable. Transformers, because 28 percent of their mass is in the conductor, are reduced in weight by the same factor. Capacitors are helped the least with only negligible savings possible. Finally, because HTS can relax the requirement to use alternating current in order to reduce conductor mass, it will be possible to generate significant savings by eliminating most transformers and capacitors.

Aron, Paul R.↗

Protection Against Brief Interruptions Of Power

Rotating standby power system compensates for brief interruptions in commercial power supply. System furnishes few cycles of alternating current from its stored rotational energy. Protects equipment vulnerable to brief losses of power; for example, prevents computers from erroneously suppressing or adding bits to data being handled at moment of power failure.

Casad, Theodore A.↗

Electrochemical Studies Of Aluminum Coated With Primer

Technical paper describes experiments using ac-impedance method of analyzing corrosion of metal surfaces and breakdown of protective coatings. Alternating-current-impedance scans provide more detailed information, indicating changes in corrosion rates, progressive deterioration of coatings, changes in metal surfaces, and reaction mechanisms. Changes in conditions of coatings detected by ac method before dc methods show increase in metal-corrosion current. Measurements of impedance as function of frequency provides sufficient data to enable resistances and capacitances to be determined by performing least-squares fit. Knowledge of dependence of these values on time leads to more detailed understanding of corrosion process.

Danford, Merlin D.↗

The application of high temperature superconductors to space electrical power distribution components

Some important space based electrical power distribution systems and components are examined to determine what might be achieved with the introduction of high temperature superconductors (HTS). Components that are compared in a before-and-after fashion include transformers, transmission lines, and capacitors. It is concluded that HTS has its greatest effect on the weight associated with transmission lines, where the weight penalty could be reduced by as much as 130 kg/kW/km of cable. Transformers, because 28 percent of their mass is in the conductor, are reduced in weight by the same factor. Capacitors are helped the least with only negligible savings possible. Finally, because HTS can relax the requirement to use alternating current in order to reduce conductor mass, it will be possible to generate significant savings by eliminating most transformers and capacitors.

Aron, Paul R.↗

Automated Power-Distribution System

Automated power-distribution system monitors and controls electrical power to modules in network. Handles both 208-V, 20-kHz single-phase alternating current and 120- to 150-V direct current. Power distributed to load modules from power-distribution control units (PDCU's) via subsystem distributors. Ring busses carry power to PDCU's from power source. Needs minimal attention. Detects faults and also protects against them. Potential applications include autonomous land vehicles and automated industrial process systems.

Thomason, Cindy↗

Three-Zone Programmable Temperature Controller

Microprocessor-based controller regulates electrical power supplied to heater in each zone of three-zone directional-solidification furnace. Intended primarily for use in microgravity experiments aboard KC-135 airplane, controller also used on ground. Offers advantage of low electrical noise and consequent minimal interference with low-level signals put out by thermocouples and other sensors used in experiments. Achieved by heating with direct (instead of alternating) current and not pulsing heating current.

Smith, Guy A.↗

Laboratory studies of the electrical conductivity of silicate perovskites at high pressures and temperatures

The electrical conductivities of two silicate perovskites and a perovskite-magnesiowuestite assemblage, all having an atomic ratio of Mg to Fe equal to 0.88/0.12, have been measured with alternating current and direct current (dc) techniques at simultaneously high pressures and temperatures. Measurements up to pressures of 80 GPa and temperatures of 3500 K, using a laser-heated diamond anvil cell, demonstrate that the electrical conductivity of these materials remains below 10-3 S/m at lower mantle conditions. The activation energies for electrical conduction are between 0.1 and 0.4 eV from the data, and the conduction in these perovskites is ascribed to an extrinsic electronic process. The new measurements are in agreement with a bound that was previously obtained from dc measurements for the high-PT conductivity of perovskite-dominated assemblages. The results show that the electrical conductivity of (Mg/0.88/Fe/0.12)SiO3 perovskite differs significantly from that of the earth's deep mantle, as inferred from geophysical observations.

Li, Xiaoyuan↗

Method of fabricating composite structures

A method of fabricating structures formed from composite materials by positioning the structure about a high coefficient of thermal expansion material, wrapping a graphite fiber overwrap about the structure, and thereafter heating the assembly to expand the high coefficient of thermal expansion material to forcibly compress the composite structure against the restraint provided by the graphite overwrap. The high coefficient of thermal expansion material is disposed about a mandrel with a release system therebetween, and with a release system between the material having the high coefficient of thermal expansion and the composite material, and between the graphite fibers and the composite structure. The heating may occur by inducing heat into the assembly by a magnetic field created by coils disposed about the assembly through which alternating current flows. The method permits structures to be formed without the use of an autoclave.

Sigur, W. A.↗

Spatial variations in ac susceptibility and microstructure for the YBa2Cu3O(7-x) superconductor and their correlation with room-temperature ultrasonic measurements

The spatial (within-sample) uniformity of superconducting behavior and microstructure in YBa2Cu3O(7-x) specimens over the pore fraction range of 0.10 to 0.25 was examined. The viability of using a room-temperature, nondestructive characterization method (ultrasonic velocity imaging) to predict spatial variability was determined. Spatial variations in superconductor properties were observed for specimens containing 0.10 pore fraction. An ultrasonic velocity image constructed from measurements at 1 mm increments across one such specimen revealed microstructural variation between edge and center locations that correlated with variations in alternating-current shielding and loss behavior. Optical quantitative image analysis on sample cross-sections revealed pore fraction to be the varying microstructural feature.

Roth, Don J.↗

A passive bearing system using superconducting magnets

A passive radial bearing concept is presented using superconducting magnets which can generate a bearing pressure as high as 360 N/sq cm, comparable to a conventional active bearing system. The system consists of a number of solenoidal superconducting coils of alternating current direction. These coils are stacked axially over the bearing length and connected in series. The currents in stator and rotor coils are in the opposite directions, generating repulsive forces. This system, in comparison with an active system, has the advantage of much smaller power dissipation in the coils since the coil currents are mostly dc currents. The cooling for the superconducting coils is therefore simpler, and the coils are more stable. An optimization study seeking the maximum bearing pressure was conducted. Details of the design, pressure calculations, and results are presented.

Huang, X.↗

Spatial variations in a.c. susceptibility and microstructure for the YBa2Cu3O(7-x) superconductor and their correlation with room-temperature ultrasonic measurements

The spatial (within-sample) uniformity of superconducting behavior and microstructure in YBa2Cu30(7-x) specimens over the pore fraction range of 0.10 to 0.25 was examined. The viability of using a room-temperature, nondestructive characterization method (ultrasonic velocity imaging) to predict spatial variability was determined. Spatial variations in superconductor properties were observed for specimens containing 0.10 pore fraction. An ultrasonic velocity image constructed from measurements at 1 mm increments across one such specimen revealed microstructural variation between edge and center locations that correlated with variations in alternating-current shielding and loss behavior. Optical quantitative image analysis on sample cross-sections revealed pore fraction to be the varying microstructural feature.

Roth, Don J.↗

Development of software to improve AC power quality on large spacecraft

To insure the reliability of a 20 kHz, alternating current (AC) power system on spacecraft, it is essential to analyze its behavior under many adverse operating conditions. Some of these conditions include overloads, short circuits, switching surges, and harmonic distortions. Harmonic distortions can become a serious problem. It can cause malfunctions in equipment that the power system is supplying, and, during distortions such as voltage resonance, it can cause equipment and insulation failures due to the extreme peak voltages. To address the harmonic distortion issue, work was begun under the 1990 NASA-ASEE Summer Faculty Fellowship Program. Software, originally developed by EPRI, called HARMFLO, a power flow program capable of analyzing harmonic conditions on three phase, balanced, 60 Hz AC power systems, was modified to analyze single phase, 20 kHz, AC power systems. Since almost all of the equipment used on spacecraft power systems is electrically different from equipment used on terrestrial power systems, it was also necessary to develop mathematical models for the equipment to be used on the spacecraft. The modelling was also started under the same fellowship work period. Details of the modifications and models completed during the 1990 NASA-ASEE Summer Faculty Fellowship Program can be found in a project report. As a continuation of the work to develop a complete package necessary for the full analysis of spacecraft AC power system behavior, deployment work has continued through NASA Grant NAG3-1254. This report details the work covered by the above mentioned grant.

Kraft, L. Alan↗

Structure/load dependent vectors for linear structural dynamic analysis

The dynamic solution vectors yielded by the present structure/load dependent-vectors method for large-scale linear structural dynamic analyses involving complex loadings can be used as starting vectors, so that both structure and load characteristics are encompassed by the basis vectors. The method is shown to entail fewer vectors than current alternatives for a given level of accuracy, especially in the cases of structures that have external concentrated masses. Numerical results are presented which illustrate the advantages of this dependent-vectors method relative to other reduction methods.

Qin, Jiangning↗

Astro-archaeology - The white dwarfs and hot subwarfs

By 'astroarcheology' is presently meant the effort to ascertain the Galaxy's past in light of what is found in its most ancient, white dwarf constituents. Attention is given to the controversial role of the hot subdwarfs and the theory of white dwarf spectral evolution, as well as to the concept of the 'Whole Earth Telescope', involving continuous photometric coverage of rapidly varying astronomical sources and thereby eliminating the otherwise troublesome diurnal gaps in data. Much higher resolution of the power spectra of these objects is attainable by these means than any current alternative.

Van Horn, Hugh M.↗

Pulsed-Current Welding Of Nickel-Based Alloy

Joints as strong (or stronger than) joints made with constant current. Report based on study of pulsed-current versus constant-current gas/tungsten arc welding of butt joints between panels of nickel-based alloy 718. In pulsed-current welding, arc current alternated between high and low value. Enables greater control of freezing and depth of penetration of weld puddle at given heat input. Thicker sections joined. Readily incorporated into automated welding system, with resultant greater uniformity and reproducibility of welds than attained in manual welding.

Gamwell, W. R.↗

Generating AC With Rotating Solar Cells

Rotating solar photovoltaic cells or batteries connected to suitable mechanical and/or electronic commutators produce nearly sinusoidal alternating current. Eliminates need for inverter circuitry and its attendant power-consumption and heat-dissipation problems, but imposes need for low-power-consumption rotary mechanism. Intended for use aboard spacecraft, also useful in special terrestrial situations where solar electric power must be transmitted over powerlines from one remote location to another.

Flanagan, David T.↗

An AC-electromagnetic bearing for flywheel energy storage in space

A repulsive type AC-electromagnetic bearing was developed and tested. It was conceived on the basis of the so-called Magnetic River suspension for high-speed trains. The appearance of the bearing is similar to the traditional DC-type electromagnetic bearing but the operating principle is different. The magnets are fed with alternating current instead of direct current and the rotor is fitted with a conducting sleeve (e.g. aluminum) instead of a ferromagnetic sleeve. The repulsion is due to induction of eddy-currents in the conducting sleeve. The bearing is inherently stable and requires no feedback control. It provides support in five degrees of freedom such that a short rotor may be fully supported by a single bearing. These capabilities were demonstrated experimentally. On the down side, the load carrying capacity and the damping obtained so far were quite low compared to the DC-type bearing. Also, significant heating of the conducting sleeve was experienced. The AC-bearing is essentially a modified induction motor and there are strong indications that it can be run both as a motor and as a generator with no commutator requirements. It is therefore considered to be a good candidate for support of energy storage flywheels in space.

Nikolajsen, Jorgen L.↗