Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

2.2 micron image of 3C 368 at z = 1.13, a galaxy with aligned radio and stellar axes

A K-band IR image of the z = 1.13 radio galaxy 3C 368, one of the brightest examples of the recently discovered phenomenon of alignment between the optical and radio axes of powerful distant radio galaxies, is presented. The observations show that the IR morphology is also elongated and aligned along the optical and radio axes, but is not coincident with the radio emission. Various mechanisms for producing the IR and optical flux and the resultant constraints on the origin of the alignment effect in high-redshift radio galaxies are discussed. The most likely explanation is that the emission is produced mainly by young stars formed by interaction of the radio source with the ISM. The IR flux is then interpreted as dominated by a population of red supergiants. Independent of the origin of the emission, the observed alignment implies that powerful radio galaxies at high redshifts are distant from giant ellipticals, even in the IR. Hence, attempts to derive a cosmological 'standard candle' using studies which combine these two types of galaxies are likely to be invalid.

Chambers, K. C.↗

Field-aligned current signatures in the near-tail region. I - ISEE observations in the plasma sheet boundary layer

Field-aligned currents in the near-tail region are examined using ISEE magnetometer data. Two substorms (the 1054 UT and the 1436 UT substorms on March 22, 1979) were examined, demonstrating the consistency of the current polarity and intensity with observations at lower altitudes, which suggests that field-aligned currents in the plasma sheet boundary layer are parts of the large-scale current system, the region-1 system. An examination of the steplike changes of the magnetic field direction, which correspond to the spacecraft crossing of a net field-aligned current, showed that the field-aligned currents in the plasma sheet boundary layer have the same polarity as the region-1 system.

Ohtani, S.↗

Aligning Plasma-Arc Welding Oscillations

Tool aids in alignment of oscillator probe on variable-polarity plasma-arc welding torch. Probe magnetically pulls arc from side to side as it moves along joint. Tensile strength of joint depends on alignment of weld bead and on alignment of probe. Operator installs new tool on front of torch body, levels it with built-in bubble glass, inserts probe in slot on tool, and locks probe in place. Procedure faster and easier and resulting alignment more accurate and repeatable.

Norris, Jeff↗

Jig Aligns Shadow Mask On CCD

Alignment viewed through microscope. Alignment jig positions shadow mask on charge-coupled device (CCD) so metal film deposited on it precisely. Allows CCD package to be inserted and removed without disturbing alignment of mask. Holds CCD packages securely and isolates it electrostatically while providing electrical contact to each of its pins. When alignment jig assembled with CCD, used to move mask under micrometer control.

Matus, Carlos V.↗

Generation of macroscopic magnetic-field-aligned electric fields by the convection surge ion acceleration mechanism

The 'convection surge' model for ion acceleration, designed by Mauk (1986) to explain the observed ion distributions and the field-aligned character of middle magnetospheric ion distributions during the expansion phase of a substorm, was extended to include the self-consistent generation of magnetic-field-aligned electric fields. Results from the modified model show that the convection surge mechanism leads to the generation of dynamical macroscopic magnetic field-aligned electric fields that begin their strongest developments very near the magnetic equator and then propagate to higher latitudes. Potential drops as high as 1 to 10 kV might be expected, depending on the mass species of the ions and on the electron temperatures. It is speculated that the convection surge mechanism could be a key player in the transient field-aligned electromagnetic processes observed to operate within the middle magnetosphere.

Mauk, B. H.↗

Solar sensor subsystems alignment check using solar scans for the Halogen Occultation Experiment

The alignment of a dual-axes sun sensor subsystem to a telescope having a multiple sensor subsystem is described. The sun sensor consists of two analog and one digital silicon detectors. The analog detectors are shadow mask type operating in the visible spectrum. The detectors are mounted for azimuth and elevation positioning of biaxial gimbals. The digital detector is a linear diode array that operates at a spectral position of 0.7 micron and is used for elevation positioning. The position signals correspond to relative angles between the sun sensor and the solar disk. These three detectors are aligned on an Invar structure which is mounted to a Cassegrain telescope. This telescope relays solar radiance to an eight channel detector subsystem operating in the infrared range from 2 to 10 microns. The test technique and results to check the boresight alignment of these two subsystems by scanning the solar disk will be reported. The boresight alignment for both the azimuth and elevation axes of the two detector subsystems is verified using this technique.

Jurczyk, S. G.↗

Attitude sensor alignment calibration for the solar maximum mission

An earlier heuristic study of the fine attitude sensors for the Solar Maximum Mission (SMM) revealed a temperature dependence of the alignment about the yaw axis of the pair of fixed-head star trackers relative to the fine pointing Sun sensor. Here, new sensor alignment algorithms which better quantify the dependence of the alignments on the temperature are developed and applied to the SMM data. Comparison with the results from the previous study reveals the limitations of the heuristic approach. In addition, some of the basic assumptions made in the prelaunch analysis of the alignments of the SMM are examined. The results of this work have important consequences for future missions with stringent attitude requirements and where misalignment variations due to variations in the temperature will be significant.

Pitone, Daniel S.↗

Field-aligned current associated with a distorted two-cell convection pattern during northward interplanetary magnetic field

The influence of the ionospheric conductance on the field-aligned current associated with a distorted two-cell convection pattern during northward IMF was investigated using the Heppner-Maynard (1987) convection model and the Utah State University conductivity model described by Rasmussen and Schunk (1987). Results show that the variation of the ionospheric conductivity distribution can significantly affect the features of the field-aligned current for northward IMF, where matching or mismatching between the conductance gradient and the convection electric field plays a key role. It was found that the increase of the field-aligned current in the polar cap observed during summer is mainly due to the increasing contribution from the Pedersen current, and that the increase of the field-aligned current in both the oval region and the evening-midnight sector during the active aurora period is mainly due to the increasing contribution from the Hall current.

Zhu, L.↗

Self-Aligning Optical Measurement Systems

The paper discusses how to teach a system of neural networks to respond to the alignment clues used by a human operator in performing routine, initial alignments. A paradigm is proposed for automating the alignment of the components of optical measurement systems. The paradigm which was tested on a spatial filter has proved to be successful for optical alignment.

Decker, Arthur J.↗

Dynamic interferometer alignment and its utility in UV Fourier transform spectrometer systems

Dynamic alignment has been demonstrated as a practical approach to alignment maintenance for systems in the infrared region of the spectrum. On the basis of work done by OPTRA, this technique was introduced in commercial Fourier transform spectrometer systems in 1982 and in various forms is now available from a number of manufacturers. This paper reports on work by OPTRA to extend the basic technique to systems operating in the ultraviolet. In addition, this paper reports the preliminary results of the development of an alignment system using a laser diode in place of a gas laser normally found in dynamic alignment systems. A unique optical system and spatial heterodyne technique allows for achievement of a metrology system with characteristics that fully satisfy the requirements of an ultraviolet spectrometer system.

Dorval, Rick K.↗

Special test equipment and fixturing for MSAT reflector assembly alignment

The MSAT Reflector Assembly is a state of the art subsystem for Mobile Satellite (MSAT), a geosynchronous-based commercial mobile telecommunication satellite program serving North America. The Reflector Assembly consisted of a deployable, three-hinge, folding-segment Boom, deployable 5.7 x 5.3-meter 16-rib Wrap-Rib Reflector, and a Reflector Pointing Mechanism (RPM). The MSAT spacecraft was based on a Hughes HS601 spacecraft bus carrying two Reflector Assemblies independently dedicated for L-band transmit and receive operations. Lockheed Missiles and Space Company (LMSC) designed and built the Reflector Assembly for MSAT under contract to SPAR Aerospace Ltd. Two MSAT satellites were built jointly by SPAR Aerospace Ltd. and Hughes Space and Communications Co. for this program, the first scheduled for launch in 1994. When scaled for wavelength, the assembly and alignment requirements for the Reflector Assembly were in many instances equivalent to or exceeded that of a diffraction-limited visible light optical system. Combined with logistical constraints inherent to large, compliant, lightweight structures; 'bolt-on' alignment; and remote, indirect spacecraft access; the technical challenges were formidable. This document describes the alignment methods, the special test equipment, and fixturing for Reflector Assembly assembly and alignment.

Young, Jeffrey A.↗

Aligning parallel arrays to reduce communication

Axis and stride alignment is an important optimization in compiling data-parallel programs for distributed-memory machines. We previously developed an optimal algorithm for aligning array expressions. Here, we examine alignment for more general program graphs. We show that optimal alignment is NP-complete in this setting, so we study heuristic methods. This paper makes two contributions. First, we show how local graph transformations can reduce the size of the problem significantly without changing the best solution. This allows more complex and effective heuristics to be used. Second, we give a heuristic that can explore the space of possible solutions in a number of ways. We show that some of these strategies can give better solutions than a simple greedy approach proposed earlier. Our algorithms have been implemented; we present experimental results showing their effect on the performance of some example programs running on the CM-5.

Sheffler, Thomas J.↗

Alignment Measurements of the Microwave Anisotropy Probe (MAP) Instrument in a Thermal/Vacuum Chamber

The Microwave Anisotropy Probe (MAP) Observatory, scheduled for a fall 2000 launch, is designed to measure temperature fluctuations (anisotropy) and produce a high sensitivity and high spatial resolution (approximately 0.2 degree) map of the cosmic microwave background (CMB) radiation over the entire sky between 22 and 90 GHz. MAP utilizes back-to-back Gregorian telescopes to focus the microwave signals into 10 differential microwave receivers, via 20 feed horns. Proper alignment of the telescope reflectors and the feed horns at the operating temperature of 90 K is a critical element to ensure mission success. We describe the hardware and methods used to validate the displacement/deformation predictions of the reflectors and the microwave feed horns during thermal/vacuum testing of the reflectors and the microwave instrument. The smallest deformation predictions to be measured were on the order of +/- 0.030 inches (+/- 0.762 mm). Performance of these alignment measurements inside a thermal/vacuum chamber with conventional alignment equipment posed several limitations. The most troublesome limitation was the inability to send personnel into the chamber to perform the measurements during the test due to vacuum and the temperature extremes. The photogrammetry (PG) system was chosen to perform the measurements since it is a non- contact measurement system, the measurements can be made relatively quickly and accurately, and the photogrammetric camera can be operated remotely. The hardware and methods developed to perform the MAP alignment measurements using PG proved to be highly successful. The measurements met the desired requirements, for the metal structures enabling the desired distortions to be measured resolving deformations an order of magnitude smaller than the imposed requirements. Viable data were provided to the MAP Project for a full analysis of the on-orbit performance of the Instrument's microwave system.

Hill, Michael D.↗

Orbital Verification of the CXO High-Resolution Mirror Assembly Alignment and Vignetting

Prior to launch, the High Resolution Mirror Assembly (HRMA) of the Chandra X-ray Observatory underwent extensive ground testing at the X-ray Calibration Facility (XRCF) at the Marshall Space Flight Center in Huntsville. Observations made during the post-launch Orbital Activation and Calibration period, allow the on-orbit condition of the X-ray optics to be assessed. Based on these ground-based and on-orbit data, we examine the alignment of the x-ray optics based on the PSF, and the boresight and alignment of the optical axis alignment relative to the detectors. We examine the vignetting and the single reflection ghost suppression properties of the telescope. Slight imperfections in alignment lead to a small azimuthal dependence of the off-axis area; the morphology of off-axis images also shows an additional small azimuthal dependence varying as 1/2 the off-axis azimuth angle.

Gaetz, T. J.↗

Experiments in Aligning Threaded Parts Using a Robot Hand

Techniques for determining and correcting threaded part alignment using force and angular position data are developed to augment currently limited techniques for align- ing threaded parts. These new techniques are based on backspinning a nut with respect to a bolt and measuring the force change that occurs when the bolt "falls" into the nut. Kinematic models that describe the relationship between threaded parts during backspinning are introduced and are used to show how angular alignment may be determined. The models indicate how to distinguish between the aligned and misaligned cases of a bolt and a nut connection by using axial force data only. In addition, by tracking the in-plane relative attitude of the bolt during spinning, data can be obtained on the direction of the angular misalignment which, in turn, is used to correct the misalignment. Results from experiments using a bolt held in a specialized fixture and a three fingers Stanford/JPL hand are presented.

Diftler, M. A.↗

Alignment Measurements of the Microwave Anisotropy Probe (MAP) Instrument in a Thermal/Vacuum Chamber Using Photogrammetry

The Microwave Anisotropy Probe (MAP) Observatory, scheduled for a late 2000 launch, is designed to measure temperature fluctuations (anisotropy) and produce a high sensitivity and high spatial resolution (< 0.3 deg at 90 GHz.) map of the cosmic microwave background (CMB) radiation over the entire sky between 22 and 90 GHz. MAP utilizes back-to-back Gregorian telescopes to focus the microwave signals into 10 differential microwave receivers, via 20 feed horns. Proper alignment of the telescope reflectors and the feed horns at the operating temperature of 90 K is a critical element to ensure mission success. We describe the hardware and methods used to validate the displacement/deformation predictions of the reflectors and the microwave feed horns during thermal/vacuum testing of the reflectors and the microwave instrument. The smallest deformations to be resolved by the measurement system were on the order of +/- 0.030 inches (0.762 mm). Performance of these alignment measurements inside a thermal/vacuum chamber with conventional alignment equipment posed several limitations. A photogrammetry (PG) system was chosen to perform the measurements since it is a non-contact measurement system, the measurements can be made relatively quickly and accurately, and the photogrammetric camera can be operated remotely. The hardware and methods developed to perform the MAP alignment measurements using PG proved to be highly successful. The PG measurements met the desired requirements, enabling the desired deformations to be measured and even resolved to an order of magnitude smaller than the imposed requirements. Viable data were provided to the MAP Project for a full analysis of the on-orbit performance of the Instrument's microwave system.

Hill, Michael D.↗

Strong IMF By-Related Plasma Convection in the Ionosphere and Cusp Field-Aligned Currents Under Northward IMF Conditions

We present in this paper an investigation of IMF-By related plasma convection and cusp field-aligned currents using FAST data and AMIE model during a prolonged interval with large positive IMF By and northward Bz conditions (By/Bz much greater than 1). Using the FAST single trajectory observations to validate the global convection patterns at key times and key locations, we have demonstrated that the AMIE procedure provides a reasonably good description of plasma circulations in the ionosphere during this interval. Our results show that the plasma convection in the ionosphere is consistent with the anti-parallel merging model. When the IMF has a strongly positive By component under northward conditions, we find that the global plasma convection forms two cells oriented nearly along the Sun-earth line in the ionosphere. In the northern hemisphere, the dayside cell has clockwise convection mainly circulating within the polar cap on open field lines. A second cell with counterclockwise convection is located in the nightside circulating across the polar cap boundary, The observed two-cell convection pattern appears to be driven by the reconnection along the anti-parallel merging lines poleward of the cusp extending toward the dusk side when IMF By/Bz much greater than 1. The magnetic tension force on the newly reconnected field lines drives the plasma to move from dusk to dawn in the polar cusp region near the polar cap boundary. The field-aligned currents in the cusp region flow downward into the ionosphere. The return field-aligned currents extend into the polar cap in the center of the dayside convection cell. The field-aligned currents are closed through the Peterson currents in the ionosphere, which flow poleward from the polar cap boundary along the electric field direction.

Le, G.↗

A Nonlinear Observer for Gyro Alignment Estimation

A nonlinear observer for gyro alignment estimation is presented. The observer is composed of two error terms, an attitude error and an alignment error. The observer is globally stable with exponential convergence of the attitude errors. The gyro alignment estimate converges to the true alignment when the system is completely observable.

Thienel, J.↗