Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aggregate flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Benefits of Bayesian Hierarchical Methods for Analyzing Heterogeneous Environmental Datasets: A Case Study of Marine Organic Carbon Fluxes

Large compilations of heterogeneous environmental observations are increasingly available as public databases, allowing researchers to test hypotheses across datasets. Statistical complexities arise when analyzing compiled data due to unbalanced spatial sampling, variable environmental context, mixed measurement techniques, and other reasons. Hierarchical Bayesian modeling is increasingly used in environmental science to describe these complexities, however few studies explicitly compare the utility of hierarchical Bayesian models to simpler and more commonly applied methods. Here we demonstrate the utility of the hierarchical Bayesian approach with application to a large compiled environmental dataset consisting of 5,741 marine vertical organic carbon flux observations from 407 sampling locations spanning eight biomes across the global ocean. We fit a global scale Bayesian hierarchical model that describes the vertical profile of organic carbon flux with depth. Profile parameters within a particular biome are assumed to share a common deviation from the global mean profile. Individual station-level parameters are then modeled as deviations from the common biome-level profile. The hierarchical approach is shown to have several benefits over simpler and more common data aggregation methods. First, the hierarchical approach avoids statistical complexities introduced due to unbalanced sampling and allows for flexible incorporation of spatial heterogeneitites in model parameters. Second, the hierarchical approach uses the whole dataset simultaneously to fit the model parameters which shares information across datasets and reduces the uncertainty up to 95% in individual profiles. Third, the Bayesian approach incorporates prior scientific information about model parameters; for example, the non-negativity of chemical concentrations or mass-balance, which we apply here. We explicitly quantify each of these properties in turn. We emphasize the generality of the hierarchical Bayesian approach for diverse environmental applications and its increasing feasibility for large datasets due to recent developments in Markov Chain Monte Carlo algorithms and easy-to-use high-level software implementations.

54 ENVIRONMENTAL SCIENCES↗

Packetized Energy Management: Coordinating Transmission and Distribution (Final Report)

The project Packetized Energy Management (PEM): Coordinating Transmission and Distribution was part of the ARPA-E NODES program from 2015 to 2023. The high-level goal of the project was to develop and demonstrate novel, scalable, and impactful technologies related to the coordination of networked distributed energy resources (DERs). By demonstrating responsive means by which fleets of DERs could be coordinated to enhance grid operation and reliability, the U.S. could accelerate renewable integration and electrification efforts and meet decarbonization goals.

25 ENERGY STORAGE↗

How to Build a Connected Community: Policies to Promote Grid-interactive Efficient Buildings and Demand Flexibility

Efficient, connected, grid-interactive, smart, and flexible buildings are key to decarbonizing the U.S. energy economy, optimizing energy use, reducing electric consumers’ bills, integrating variable renewable energy resources, and improving the reliability and performance of the nation’s electricity grids. Such grid-interactive efficient buildings have high levels of energy efficiency layered with other distributed energy resources (DERs) and intelligent controls to provide demand flexibility. Policy support is unfolding at the federal, state, and local levels to transform homes and workplaces into state-of-the-art energy-efficient buildings and community-level grid services. This paper starts by describing the potential benefits. Next, it highlights existing policies — with a focus on state-level actions — that support grid-interactive efficient building deployment and demand flexibility. Finally, it identifies current trends and gaps, policies and programs that promote grid-interactive efficient buildings, and aggregations of grid-interactive efficient buildings referred to as Virtual Power Plants.

Schwartz, Lisa C↗

Hexagonal Distributed Embedded Energy Converters (HexDEECs)

The HexDEEC is a small, characteristic length approximating a centimeter, energy transducer that converts the dynamic deformations of its elastomer housing into electricity through a variable capacitance charging-discharging cycle. This device is a type of Distributed Embedded Energy Converter Technology (DEEC-Tec), a new domain for marine renewable energy research that utilizes a conglomeration of small distributed embedded energy converters (DEECs) that, in aggregate, form larger metamaterial frameworks. These resulting DEEC-Tec metamaterials can then, in turn, be used to construct flexible ocean wave energy converters called flexWECs, which can utilize a broad band of ocean wave frequencies and lack highly loaded rigid bodies. These systems also provide new avenues of wave energy harvesting such as actively transforming topologies (e.g., shape and form) and morphologies (e.g., stiffness and damping throughout its entire structure) in real time. Presented, is one specific type of DEEC: the HexDEEC, which is currently being developed by the United States National Renewable Energy Laboratory. This transducer shows promise in aiding the adoption and further development of the DEEC-Tec domain. The following presentation focuses on the promise of this technology and current work being done to analyze the performance of an individual HexDEEC design. The HexDEEC is composed of a hyperelastic hexagonal housing, nominally silicon rubber, with six electrodes on its inner faces. The upper three electrodes share the same charge while the lower three electrodes oppose the upper electrode charges. Externally, the HexDEEC has two arms extending away from the middle vertices of the hexagon. Via principles governing the relationship between electrical capacitance and electrical potential (voltage and charge), electricity is generated when the HexDEEC's arms are dynamically pulled or released under tensile loading, as doing so causes the distance between the upper and lower sets of electrodes to change - varying the energy converter's overall capacitance. Analytical and numerical modeling is being used to evaluate the mechanics and electrical energy generated by the HexDEEC. Equations to describe the capacitance and electrostatic forces acting on this unique system have been developed and implemented into the numerical modeling software STAR-CCM+, along with models to describe its hyperelastic material, such as the Mooney-Rivlin 3-parameter model. So far, an initial design has been analyzed and we plan to further optimize it to increase power production. Individual HexDEECs have been fabricated by drawing uncured liquid silicon rubber into molds via vacuum pressure. To simplify manufacturing, HexDEEC sub-components - e.g., electrodes, wires - can be placed within those molds such that they are directly embedded into the hexagonal housing during the curing process. Furthermore, DEEC-Tec metamaterials can be created by interweaving or sequentially layering multiple HexDEEC strands together. The HexDEEC based metamaterial could then generate electricity through its gross deformations. Ultimately, HexDEECs represent a specific type of energy transducer that can be leveraged, by the DEEC-Tec domain, to create metamaterials used to construct novel flexWECs.

DEEC-Tec↗

Hexagonal Distributed Embedded Energy Converters (HexDEECs)

Distributed Embedded Energy Converter Technologies (DEEC-Tec) is a new domain for marine renewable energy research that utilizes a conglomeration of small distributed embedded energy converters (DEECs) that, in aggregate, form larger metamaterial frameworks. These resulting DEEC-Tec metamaterials can then, in turn, be used to construct flexible ocean wave energy converters called flexWECs. DEEC-Tec enables flexWECs: (i) to be inherently broad-banded ocean wave frequency energy converters and (ii) to have an inherent lack of highly loaded rigid bodies. The DEEC-Tec domain also benefits the marine renewable energy domain by inherently availing ways that marine energy can be harvested and converted that heretofore has not yet been considered possible: real-time execution of transforming topologies (e.g., actively changing a flexWEC's shape and form) and morphologies (e.g., actively changing a flexWEC's stiffness and damping throughout its entire structure). Presented, is one specific type of DEEC, a HexDEEC, that shows promise in aiding the adoption and further development of the DEEC-Tec domain - it is a small energy transducer being developed by the United States National Renewable Energy Laboratory. The HexDEEC is a small (characteristic length approximating a centimeter) energy transducer that converts the dynamic deformations of an elastomer into electricity through a charging-discharging cycle of a capacitor whose capacitance is varied by those elastic deformations. The HexDEEC is composed of a hyperelastic hexagonal housing (nominally silicon rubber) with six electrodes on its inner faces. The upper three electrodes share the same charge while the lower three electrodes oppose the upper electrode charges. Externally, the HexDEEC has two arms extending away from the middle vertices of the hexagon. Via principles governing the relationship between electrical capacitance and electrical potential (voltage and charge), electricity is generated when the HexDEEC's arms are dynamically pulled or released under tensile loading as doing so causes the distance between the upper and lower sets of electrodes to change - varying the energy converter's overall capacitance. Analytical and numerical modeling have already been used to estimate the electrical energy produced by a HexDEEC. The cursory models approximate the HexDEEC as a parallel plate variable capacitor - simplifying from six to two opposing plates with a constant dielectric volume between those two plates. To account for the elastic HexDEEC material properties, software such as SolidWorks and STAR-CCM+ have been used to generate hyperelastic models; notably, Mooney-Rivlin based models. Individual HexDEECs have been fabricated by drawing uncured liquid silicon rubber into molds via vacuum pressure. To simplify manufacturing, HexDEEC sub-components - e.g., electrodes, wires - can be placed within those molds such that they are directly embedded into the hexagonal housing during the curing process. Furthermore, DEEC-Tec metamaterials can be created by interweaving or sequentially layering multiple HexDEEC strands together. The HexDEEC based metamaterial could then generate electricity through its gross deformations. Ultimately, HexDEECs represent a specific type of energy transducer that can be leveraged, by the DEEC-Tec domain, to create metamaterials used to construct novel flexWECs.

DEEC-Tec↗

High-Efficiency Modular SiC-based Power-Converter for Flexible-CHP Systems with Stability-Enhanced Grid-Support Functions

This project seeks to develop a modular, scalable MV power converter featuring stability-enhanced grid-support functions for future grid-interface applications in flexible combined heat and power (F-CHP) cogeneration plants, being fully compliant with the IEEE Standard 1547, category B—for operation in local areas with high aggregated distributed energy resource (DER) penetration, and also with the IEEE standard for the specification of microgrid controllers, namely IEEE Std 2030.7, with the goal to enable F-CHP systems for both microgrid and standalone applications. Further, the proposed converter will use a modular circuit topology, the MMC, which is scalable both in voltage and current by interconnecting power-cell building blocks, thus flexibly suiting the needs of F-CHP systems in the 1–20 MWe range. Furthermore, the use of 10 kV SiC MOSFET devices will minimize the number of power-cells needed to operate in 2–13.8 kV MV distribution systems, but more importantly, they will render feasible a power conversion efficiency > 98 %, and a power density > 10 kW/l. This is highly relevant given that these are two key performance metrics that will further increase the value of F-CHP systems by shortening the time required to recover their investment costs.

14 SOLAR ENERGY↗

Distribution System Congestion Management - A Survey of Reliable Integration for Aggregated Resources and Microgrids

Rising penetration of consumer-owned Distribution Grid Resources (DGRs), increasingly managed by third party aggregators and enrolled in grid services and wholesale market programs, can create localized congestion in distribution networks. Managing these constraints is challenging due to a persistent coordination and information gap: utilities are accountable for reliability and have network topology and state visibility, while aggregators control the DGR capability needed to relieve congestion. This survey synthesizes congestion management solutions for distribution systems with high DGR penetration, covering both market-based mechanisms (distribution level markets, locational pricing, flexibility auctions) and non-market-based solutions (network reconfiguration, direct DGR control, demand response, curtailment, etc.). The literature is organized across three decision horizons: long term planning, operational planning, and real-time operation. Special attention is devoted to emerging distribution system operator architectures and coordination frameworks spanning transmission system operators, aggregators, and microgrids. Drawing on recent case studies and implementations, we distill best practices, identify key technical and economic barriers, and outline research directions. The evidence points to a shift toward integrated congestion management that combines market signals with technical controls, enabled by improved monitoring, forecasting, and closed loop control capabilities.

Active Distribution Networks (ADN)↗

Distributionally Robust Bilevel Optimization Model for Distribution Network With Demand Response Under Uncertain Renewables Using Wasserstein Metrics

Here, we consider a distribution network integrating demand response (DR) participants in the presence of uncertain renewable suppliers and outdoor temperatures. A bilevel optimization model is proposed to capture the intricate dynamics between price-incentivized DR participants and distribution system operations, including energy procurement and active/reactive power flows. The model is formulated as a distributional robust bilevel optimization using Wasserstein metrics. We show favorable data-driven properties including out-of-sample guarantee and asymptotic consistency. Furthermore, we present a tractable mixed-integer linear programming reformulation and characterize the worst-case distribution. Computational experiments are conducted on a modified 33-bus system. Our findings underscore the efficacy of the pricing strategies derived from the proposed bilevel optimization model. These strategies not only effectively manage DR participants' behavior but also bring equity considerations among households with various characteristics to light. The results contribute to a deeper understanding of the interplay between distribution system operators and DR participants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services: Preprint

Flexible loads have great potential to improve the power grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. The paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environment impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

control↗

Levelized cost of charging of extreme fast charging with stationary LMO/LTO batteries

Extreme DC fast charging for electric vehicles (EVs) could be competitive with the internal combustion engine refueling experience and enable longer-distance travel, which could help with EV adoption and decarbonization, but these systems have high capital costs and extremely variable high-power demands. Behind-the-meter systems (BTMS) could support extreme-fast-charging (XFC) stations to increase nationwide adoption of EVs. Here, this study examines the optimal break-even levelized cost of charging (LCOC) across 96 BTMS scenarios to enable low-wait XFC stations providing 200 miles of charge in 10 min. This research simulates LCOC via synthetic XFC-capable EV loads, machine-learned battery life models from testing data, and nonlinear optimal controls, co-minimizing complex utility costs and battery replacements. An aggregate optimal BTMS design treating each EV load as equal likely gives an optimal LCOC per utility rate, the average of which is $\$$0.59/kWh. In addition, the sensitivity of optimal and off-optimal design factors, the long-life LMO/LTO chemistry, and optimized controls are analyzed. The battery control model, based on battery stressors to compare chemistries, optimizes LMO/LTO resting state of charge and cycle depth without compromising cost reduction, which enables greater flexibility in operation. The LCOC savings due to replacement reduction are small, up to $\$$0.035/kWh (6%), with an average of $\$$0.02/kWh (3.5%). Compared with gasoline stations, the aggregate XFC station design achieves comparable speed, experience of service, and cost at $\$$3.81/gal gasoline, showing that EVs can replace gasoline vehicles even for longer-distance travel.

25 ENERGY STORAGE↗

SCUC-DER Integration Report: Integrating Distributed Energy Resources (DER) Using Advanced Unit Commitment Models and DER Aggregation Methodologies

Distributed energy resources (DERs) are continuing to grow due to regulatory, policy, and market shifts, and it needs to be ensured that small DERs are given a level playing field with traditional resources. Legacy market processes such as unit-commitment problems were designed for a power grid consisting largely of centralized power plants. In contrast, DERs consist of many small devices with distinct operating characteristics that may or may not be connected at the transmission interconnection points, limiting their visibility to the independent system operators (ISOs) who operate wholesale electricity markets. This report details the development and initial results from a simulation platform that integrates state-of-the-art security-constrained unit commitment software, detailed feeder models, and a DER aggregator model to quantify potential DER integration issues. Quantitative results to date illustrate potential infeasible scheduling solutions from SCUC when the DERA includes aggregations of energy-limited energy storage resources. Likewise, if aggregations are not penalized for dispatch deviations, they may have incentives to deviate from the SCUC-determined resource schedules. Assumptions about the amount of aggregated demand response resources (DRRs) and the ability of DERAs to follow profit incentives have an important impact – DRRs have significant flexibility and can typically feasibly meet their SCUC schedule, but on the other hand, their profit incentives can cause unscheduled increases in load before and after DRR dispatch. Computation time results on the SCUC solver and simulation platform only show a modest increase in SCUC solution time as the number of DERAs is increased, but results to date only reflect the RTS-GMLC test system; results may show more significant solver slowdown in larger transmission systems. The largest contribution to simulation time is attributed to the DERA offer generation method, which is suggested for future improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Distributed Embedded Energy Converters for Ocean Wave Energy Harvesting: Enabling a Domain of Transformative Flexible Technologies

Distributed embedded energy conversion technology (DEEC-Tec) is a very promising - but underdeveloped - domain in marine renewable energy research. The technology utilizes small distributed embedded energy converters (DEECs) that, in aggregate, form a much larger energy harvesting-converting structure. Each DEEC is a small transducer - an individual mechanism that converts one form of energy into another. A transducer's specific mode of operation can be based upon any number of physical phenomena, including variable capacitance, variable magnetic fields, or piezoelectrics. It is the dynamic deformation of a structure made from such DEECs (a DEEC-Tec structure) that provides the needed physical phenomena (the external energy source) for the underlying transducers to intake and convert energy into another form, such as electricity. DEEC-Tec structures designed specifically to dynamically deform in the presence of ocean wave energy - for the purpose of harvesting and converting that energy - can be called flexWECs. A flexWEC's gross shape (topology) and its compliant characteristics (morphologies) are chiefly determined by how the DEECs making up its structure are arranged and implemented. In turn, those corresponding topologies and morphologies will largely determine how a flexWEC interacts with - and dynamically deforms within - the presence of ocean wave energy. FlexWECs appear to have many attractive features, including broad-banded ocean energy conversion, in situ energy conversion throughout an entire flexWEC structure, inherent redundancy, and appealing material and manufacturing costs. To this end, the design and development of any particular flexWEC or flexWEC feature is a revolutionary opportunity for how we conceptualize and envision the future of ocean wave energy conversion.

DEEC↗

Modelling multiple occurrences of activities during a day: An extension of the MDCEV model

The increased interest in time use among transport researchers has led to a search for flexible but tractable models of time use, such as Bhat's Multiple Discrete Continuous Extreme Value (MDCEV) model. MDCEV formulations typically model aggregate time allocation into different activity types during a given period, such as the amount of time spent working and shopping in a day. While these applications provide valuable insights into activity participation, they ignore disaggregate activity-episodes, that is the fact that people might split their total time spent working in multiple separate blocks, with breaks or other activities in between. Insights into this splitting into episodes are necessary for predicting trips and understanding time use satiation. We propose a modified MDCEV model where an activity-episode, rather than an activity type, is the basic choice alternative, using a modified utility function to capture the reduced likelihood of individuals performing a very large number of episodes of the same activity. Results from two large revealed preference datasets exhibit equivalent forecast accuracy between the traditional and proposed approach at an aggregate level, but the latter also provides insights on the number and duration of activity-episodes with significant accuracy.

97 MATHEMATICS AND COMPUTING↗

Organic Rankine Cycle Integration and Optimization for High Efficiency CHP Genset Systems (Final Technical Report)

This project successfully advanced the integration of Organic Rankine Cycle (ORC) technology with reciprocating engine–based combined heat and power (CHP) systems to improve electrical efficiency, total CHP efficiency, and grid-responsive operation. Over three budget periods, the work progressed from high-temperature ORC component development and thermodynamic model validation to next-generation system design, working fluid transition, and techno-economic analysis. Key technical accomplishments include development and validation of a thermodynamic model capable of accurately predicting ORC performance across an expanded temperature and pressure envelope; successful identification and validation of low-global-warming-potential (GWP) working fluids—most notably R1233zd(E)—as viable replacements for R245fa; and demonstration of scalable ORC architectures suitable for integration with 1–20 MW class reciprocating engines. These advances enable flexible CHP configurations that can increase electrical output while maintaining high overall utilization of available thermal energy. The project also produced a clean-sheet design for a next-generation ORC system targeting substantially higher power output per unit, supported by detailed component selection, heat exchanger evaluation, and system-level modeling. Techno-economic analyses indicate that ORC-enabled flexible CHP systems can meet or exceed Department of Energy (DOE) efficiency targets while providing value to both facility operators and the electric grid.. Late-stage testing of the largest next-generation ORC prototype identified limitations related to pump net positive suction head (NPSH) requirements and condenser flooding under certain operating conditions. Although these issues constrained full validation of that configuration within the project timeframe, they provided clear and actionable design guidance for future system refinements. Importantly, validated modeling, smaller-scale testing, and working fluid evaluations confirmed the technical viability of the overall approach. In aggregate, this project met its core objectives by establishing validated design tools, de-risking key ORC technologies for CHP applications, and defining a credible pathway toward commercialization of flexible, high-efficiency CHP systems. The results form a strong foundation for continued development and deployment beyond the conclusion of the DOE-funded effort.

20 FOSSIL-FUELED POWER PLANTS↗

Highly Emissive Semi-Ladder-Type Copolymers, Aggregation State, and Solution-Processed Organic Light-Emitting Transistor

An organic light-emitting transistor (OLET) integrates the logic function of a field-effect transistor (FET) with electroluminescence of a light-emitting diode (LED) into a single device. This has the potential to play an important role in smart displays, electrically pumped organic laser, and other flexible electronic devices. For achieving high-performance solution-processed OLET, three semiladder copolymers—TPTI-CC, TPTI-C, and TPTI-F—were developed in this study. It was found that variation in the chemical structure lead to significant differences in energy level, emission color, and intermolecular aggregation. High photoluminescence quantum yields (PLQY) was obtained in these three polymers. Solution-processed trilayered OLET devices were fabricated, which exhibited strong electroluminescence, balanced charge mobility, and external quantum efficiency (EQE) of 2.8%.

36 MATERIALS SCIENCE↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗