Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “adaptable tools”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

(abstract) SEQ_POINTER: Next Generation, Planetary Spacecraft Remote Sensing Science Observation Design Tool

Implementation of a multimission tool, SEQ_POINTER, under the auspices of the JPL Multimission Operations Systems Office (MOSO) is in progress. This version has been designed to address the limitations experienced on previous versions when being adopted to a new mission and spacecraft. The tool has been modularly designed with subroutine interface structures to support interchangeable celestial body and spacecraft definition models. The computational and graphics modules have also been designed to interface with data collected from previous spacecraft, or on-going observations, which describe the surface of each target body. These enhancements make SEQ_POINTER a candidate for low-cost mission usage, when a remote sensing science observation design capability is required.

remote↗

A nonvoxel-based dose convolution/superposition algorithm optimized for scalable GPU architectures

Purpose: Real-time adaptive planning and treatment has been infeasible due in part to its high computational complexity. There have been many recent efforts to utilize graphics processing units (GPUs) to accelerate the computational performance and dose accuracy in radiation therapy. Data structure and memory access patterns are the key GPU factors that determine the computational performance and accuracy. In this paper, the authors present a nonvoxel-based (NVB) approach to maximize computational and memory access efficiency and throughput on the GPU. Methods: The proposed algorithm employs a ray-tracing mechanism to restructure the 3D data sets computed from the CT anatomy into a nonvoxel-based framework. In a process that takes only a few milliseconds of computing time, the algorithm restructured the data sets by ray-tracing through precalculated CT volumes to realign the coordinate system along the convolution direction, as defined by zenithal and azimuthal angles. During the ray-tracing step, the data were resampled according to radial sampling and parallel ray-spacing parameters making the algorithm independent of the original CT resolution. The nonvoxel-based algorithm presented in this paper also demonstrated a trade-off in computational performance and dose accuracy for different coordinate system configurations. In order to find the best balance between the computed speedup and the accuracy, the authors employed an exhaustive parameter search on all sampling parameters that defined the coordinate system configuration: zenithal, azimuthal, and radial sampling of the convolution algorithm, as well as the parallel ray spacing during ray tracing. The angular sampling parameters were varied between 4 and 48 discrete angles, while both radial sampling and parallel ray spacing were varied from 0.5 to 10 mm. The gamma distribution analysis method (γ) was used to compare the dose distributions using 2% and 2 mm dose difference and distance-to-agreement criteria, respectively. Accuracy was investigated using three distinct phantoms with varied geometries and heterogeneities and on a series of 14 segmented lung CT data sets. Performance gains were calculated using three 256 mm cube homogenous water phantoms, with isotropic voxel dimensions of 1, 2, and 4 mm. Results: The nonvoxel-based GPU algorithm was independent of the data size and provided significant computational gains over the CPU algorithm for large CT data sizes. The parameter search analysis also showed that the ray combination of 8 zenithal and 8 azimuthal angles along with 1 mm radial sampling and 2 mm parallel ray spacing maintained dose accuracy with greater than 99% of voxels passing the γ test. Combining the acceleration obtained from GPU parallelization with the sampling optimization, the authors achieved a total performance improvement factor of >175 000 when compared to our voxel-based ground truth CPU benchmark and a factor of 20 compared with a voxel-based GPU dose convolution method. Conclusions: The nonvoxel-based convolution method yielded substantial performance improvements over a generic GPU implementation, while maintaining accuracy as compared to a CPU computed ground truth dose distribution. Such an algorithm can be a key contribution toward developing tools for adaptive radiation therapy systems.

60 APPLIED LIFE SCIENCES↗

SU-F-BRB-07: A Plan Comparison Tool to Ensure Robustness and Deliverability in Online-Adaptive Radiotherapy

Purpose: To develop a plan comparison tool that will ensure robustness and deliverability through analysis of baseline and online-adaptive radiotherapy plans using similarity metrics. Methods: The ViewRay MRIdian treatment planning system allows export of a plan file that contains plan and delivery information. A software tool was developed to read and compare two plans, providing information and metrics to assess their similarity. In addition to performing direct comparisons (e.g. demographics, ROI volumes, number of segments, total beam-on time), the tool computes and presents histograms of derived metrics (e.g. step-and-shoot segment field sizes, segment average leaf gaps). Such metrics were investigated for their ability to predict that an online-adapted plan reasonably similar to a baseline plan where deliverability has already been established. Results: In the realm of online-adaptive planning, comparing ROI volumes offers a sanity check to verify observations found during contouring. Beyond ROI analysis, it has been found that simply editing contours and re-optimizing to adapt treatment can produce a delivery that is substantially different than the baseline plan (e.g. number of segments increased by 31%), with no changes in optimization parameters and only minor changes in anatomy. Currently the tool can quickly identify large omissions or deviations from baseline expectations. As our online-adaptive patient population increases, we will continue to develop and refine quantitative acceptance criteria for adapted plans and relate them historical delivery QA measurements. Conclusion: The plan comparison tool is in clinical use and reports a wide range of comparison metrics, illustrating key differences between two plans. This independent check is accomplished in seconds and can be performed in parallel to other tasks in the online-adaptive workflow. Current use prevents large planning or delivery errors from occurring, and ongoing refinements will lead to increased assurance of plan quality.

60 APPLIED LIFE SCIENCES↗

Influence of Pulmonary Nodules on Chest Computed Tomography and Risk of Recurrence in Stage IV Wilms Tumor

Purpose: Chest computed tomography (CT) is currently accepted as the main modality for initial disease staging and response assessment in Wilms tumor (WT). However, there is great variability in the number and size of lung metastases at the time of diagnosis and after induction chemotherapy. There is a lack of clinical evidence as to how this variability in tumor burden affects choice of therapy and disease outcome. This study sought to evaluate a previously proposed lung metastases risk stratification system based on CT findings and clinical outcomes in stage IV WT patients. Methods and Materials: Thirty-five pediatric patients with a diagnosis of stage IV WT with evaluable pre- and postdiagnosis CT scans between 1997 and 2012 were included in the analysis. Patients were divided into low-, intermediate-, and high-risk categories based on the size and number of pulmonary metastases before and after 6 weeks of chemotherapy. Association of the lung risk groups with lung recurrence-free survival and overall survival at each time point was analyzed with relevant covariates. Results: Risk group distribution both at diagnosis and after induction chemotherapy was not influenced by tumor histology. Initial risk grouping suggested an association with disease-free survival at 5 years (P=.074); however, the most significant correlation was with postinduction chemotherapy disease status (P=.027). In patients with an intermediate or high burden of disease after 6 weeks of chemotherapy, despite receiving whole-lung and boost irradiation, survival outcomes were poorer. Conclusions: Pulmonary tumor burden in stage IV WT on chest CT can predict disease outcome. Patients with intermediate- or low-risk disease, especially after induction therapy, have a higher risk for recurrence. After prospective validation, this method may become a valuable tool in adaptation of therapy to improve outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Engineering and exploitation of a fluorescent HIV-1 gp120 for live cell CD4 binding assays

The HIV-1 envelope glycoprotein, gp120, binds the host cell receptor, CD4, in the initial step of HIV viral entry and infection. This process is an appealing target for the development of inhibitory drugs and neutralizing antibodies. To study gp120 binding and intracellular trafficking, we engineered a fluorescent fusion of the humanized gp120 JRFL HIV-1 variant and GFP. Gp120-sfGFP is glycosylated with human sugars, robustly expressed, and secreted from cultured human cells. Protein dynamics, quality control, and trafficking can be visualized in live cells. The fusion protein can be readily modified with different gp120 variants or fluorescent proteins. Finally, secreted gp120-sfGFP enables a sensitive and easy binding assay that can quantitatively screen potential inhibitors of gp120-CD4 binding on live cells via fluorescence imaging or laser scanning cytometry. This adaptable research tool should aid in studies of gp120 cell biology and the development of novel anti-HIV drugs. - Highlights: • Development of fluorescent protein labeled HIV-1 envelope gp120. • Imaging of gp120 dynamics and trafficking in live cells. • Quantitative visual assay of antibody-mediated inhibition of gp120 binding to CD4 on live cells.

60 APPLIED LIFE SCIENCES↗

Sampling lattices in semi-grand canonical ensemble with autoregressive machine learning

Calculating thermodynamic potentials and observables efficiently and accurately is key for the application of statistical mechanics simulations to materials science. However, naive Monte Carlo approaches, on which such calculations are often dependent, struggle to scale to complex materials in many state-of-the-art disciplines such as the design of high entropy alloys or multi-component catalysts. To address this issue, we adapt sampling tools built upon machine learning-based generative modeling to the materials space by transforming them into the semi-grand canonical ensemble. Furthermore, we show that the resulting models are transferable across wide ranges of thermodynamic conditions and can be implemented with any internal energy model U, allowing integration into many existing materials workflows. We demonstrate the applicability of this approach to the simulation of benchmark systems (AgPd, CuAu) that exhibit diverse thermodynamic behavior in their phase diagrams. Finally, we discuss remaining challenges in model development and promising research directions for future improvements.

36 MATERIALS SCIENCE↗

Adaptive strategies for materials design using uncertainties

Here, we compare several adaptive design strategies using a data set of 223 M2AX family of compounds for which the elastic properties [bulk (B), shear (G), and Young’s (E) modulus] have been computed using density functional theory. The design strategies are decomposed into an iterative loop with two main steps: machine learning is used to train a regressor that predicts elastic properties in terms of elementary orbital radii of the individual components of the materials; and a selector uses these predictions and their uncertainties to choose the next material to investigate. The ultimate goal is to obtain a material with desired elastic properties in as few iterations as possible. We examine how the choice of data set size, regressor and selector impact the design. We find that selectors that use information about the prediction uncertainty outperform those that don’t. Our work is a step in illustrating how adaptive design tools can guide the search for new materials with desired properties.

36 MATERIALS SCIENCE↗

Advances in electron kinetics and theory of gas discharges

“Electrons, like people, are fertile and infertile: high-energy electrons are fertile and able to reproduce.”—Lev TsendinModern physics of gas discharges increasingly uses physical kinetics for analysis of non-equilibrium plasmas. The description of underlying physics at the kinetic level appears to be important for plasma applications in modern technologies. In this paper, we attempt to grasp the legacy of Professor Lev Tsendin, who advocated the use of the kinetic approach for understanding fundamental problems of gas discharges. We outline the fundamentals of electron kinetics in low-temperature plasmas, describe elements of the modern kinetic theory of gas discharges, and show examples of the theoretical approach to gas discharge problems used by Lev Tsendin. Important connections between electron kinetics in gas discharges and semiconductors are also discussed. Using several examples, we illustrate how Tsendin's ideas and methods are currently being developed for the implementation of next generation computational tools for adaptive kinetic-fluid simulations of gas discharges used in modern technologies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of 12 DIR algorithms in low-contrast regions for mass and density conserving deformation

Purpose: Deformable image registration (DIR) has become a key tool for adaptive radiotherapy to account for inter- and intrafraction organ deformation. Of contemporary interest, the application to deformable dose accumulation requires accurate deformation even in low contrast regions where dose gradients may exist within near-uniform tissues. One expects high-contrast features to generally be deformed more accurately by DIR algorithms. The authors systematically assess the accuracy of 12 DIR algorithms and quantitatively examine, in particular, low-contrast regions, where accuracy has not previously been established.Methods: This work investigates DIR algorithms in three dimensions using deformable gel (DEFGEL) [U. J. Yeo, M. L. Taylor, L. Dunn, R. L. Smith, T. Kron, and R. D. Franich, “A novel methodology for 3D deformable dosimetry,” Med. Phys. 39, 2203–2213 (2012)], for application to mass- and density-conserving deformations. CT images of DEFGEL phantoms with 16 fiducial markers (FMs) implanted were acquired in deformed and undeformed states for three different representative deformation geometries. Nonrigid image registration was performed using 12 common algorithms in the public domain. The optimum parameter setup was identified for each algorithm and each was tested for deformation accuracy in three scenarios: (I) original images of the DEFGEL with 16 FMs; (II) images with eight of the FMs mathematically erased; and (III) images with all FMs mathematically erased. The deformation vector fields obtained for scenarios II and III were then applied to the original images containing all 16 FMs. The locations of the FMs estimated by the algorithms were compared to actual locations determined by CT imaging. The accuracy of the algorithms was assessed by evaluation of three-dimensional vectors between true marker locations and predicted marker locations.Results: The mean magnitude of 16 error vectors per sample ranged from 0.3 to 3.7, 1.0 to 6.3, and 1.3 to 7.5 mm across algorithms for scenarios I to III, respectively. The greatest accuracy was exhibited by the original Horn and Schunck optical flow algorithm. In this case, for scenario III (erased FMs not contributing to driving the DIR calculation), the mean error was half that of the modified demons algorithm (which exhibited the greatest error), across all deformations. Some algorithms failed to reproduce the geometry at all, while others accurately deformed high contrast features but not low-contrast regions—indicating poor interpolation between landmarks.Conclusions: The accuracy of DIR algorithms was quantitatively evaluated using a tissue equivalent, mass, and density conserving DEFGEL phantom. For the model studied, optical flow algorithms performed better than demons algorithms, with the original Horn and Schunck performing best. The degree of error is influenced more by the magnitude of displacement than the geometric complexity of the deformation. As might be expected, deformation is estimated less accurately for low-contrast regions than for high-contrast features, and the method presented here allows quantitative analysis of the differences. The evaluation of registration accuracy through observation of the same high contrast features that drive the DIR calculation is shown to be circular and hence misleading.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-05: A Correction Algorithm for Kilovoltage Cone-Beam Computed Tomography Dose Calculations in Cervical Cancer Patients

Purpose: To investigate the accuracy and feasibility of dose calculations using kilovoltage cone beam computed tomography in cervical cancer radiotherapy using a correction algorithm. Methods: The Hounsfield units (HU) and electron density (HU-density) curve was obtained for both planning CT (pCT) and kilovoltage cone beam CT (CBCT) using a CIRS-062 calibration phantom. The pCT and kV-CBCT images have different HU values, and if the HU-density curve of CBCT was directly used to calculate dose in CBCT images may have a deviation on dose distribution. It is necessary to normalize the different HU values between pCT and CBCT. A HU correction algorithm was used for CBCT images (cCBCT). Fifteen intensity-modulated radiation therapy (IMRT) plans of cervical cancer were chosen, and the plans were transferred to the pCT and cCBCT data sets without any changes for dose calculations. Phantom and patient studies were carried out. The dose differences and dose distributions were compared between cCBCT plan and pCT plan. Results: The HU number of CBCT was measured by several times, and the maximum change was less than 2%. To compare with pCT, the CBCT and cCBCT has a discrepancy, the dose differences in CBCT and cCBCT images were 2.48%±0.65% (range: 1.3%∼3.8%) and 0.48%±0.21% (range: 0.1%∼0.82%) for phantom study, respectively. For dose calculation in patient images, the dose differences were 2.25%±0.43% (range: 1.4%∼3.4%) and 0.63%±0.35% (range: 0.13%∼0.97%), respectively. And for the dose distributions, the passing rate of cCBCT was higher than the CBCTs. Conclusion: The CBCT image for dose calculation is feasible in cervical cancer radiotherapy, and the correction algorithm offers acceptable accuracy. It will become a useful tool for adaptive radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-F-303-17: Real Time Dose Calculation of MRI Guided Co-60 Radiotherapy Treatments On Free Breathing Patients, Using a Motion Model and Fast Monte Carlo Dose Calculation

Purpose: To demonstrate real-time dose calculation of free-breathing MRI guided Co−60 treatments, using a motion model and Monte-Carlo dose calculation to accurately account for the interplay between irregular breathing motion and an IMRT delivery. Methods: ViewRay Co-60 dose distributions were optimized on ITVs contoured from free-breathing CT images of lung cancer patients. Each treatment plan was separated into 0.25s segments, accounting for the MLC positions and beam angles at each time point. A voxel-specific motion model derived from multiple fast-helical free-breathing CTs and deformable registration was calculated for each patient. 3D images for every 0.25s of a simulated treatment were generated in real time, here using a bellows signal as a surrogate to accurately account for breathing irregularities. Monte-Carlo dose calculation was performed every 0.25s of the treatment, with the number of histories in each calculation scaled to give an overall 1% statistical uncertainty. Each dose calculation was deformed back to the reference image using the motion model and accumulated. The static and real-time dose calculations were compared. Results: Image generation was performed in real time at 4 frames per second (GPU). Monte-Carlo dose calculation was performed at approximately 1frame per second (CPU), giving a total calculation time of approximately 30 minutes per treatment. Results show both cold- and hot-spots in and around the ITV, and increased dose to contralateral lung as the tumor moves in and out of the beam during treatment. Conclusion: An accurate motion model combined with a fast Monte-Carlo dose calculation allows almost real-time dose calculation of a free-breathing treatment. When combined with sagittal 2D-cine-mode MRI during treatment to update the motion model in real time, this will allow the true delivered dose of a treatment to be calculated, providing a useful tool for adaptive planning and assessing the effectiveness of gated treatments.

60 APPLIED LIFE SCIENCES↗

A Molecular Biology Tool Kit for the Phototrophic Firmicute Heliobacterium modesticaldum

The heliobacteria are members of the bacterial order Clostridiales and form the only group of phototrophs in the phylum Firmicutes . Several physiological and metabolic characteristics make them an interesting subject of investigation, including their minimalist photosynthetic system, nitrogen fixation abilities, and ability to reduce toxic metals. Although the species Heliobacterium modesticaldum is an excellent candidate as a model system for the family Heliobacteriaceae , since an annotated genome and transcriptomes are available, studies in this organism have been hampered by the lack of genetic tools. We adapted techniques for genetic manipulation of related clostridial species for use with H. modesticaldum . Five heliobacterial DNA methyltransferase genes were expressed in an Escherichia coli strain engineered as a conjugative plasmid donor for broad-host-range plasmids. Premethylation of the shuttle vectors before conjugation into H. modesticaldum is absolutely required for production of transconjugant colonies. The introduced shuttle vectors are maintained stably and can be recovered using a modified minipreparation procedure developed to inhibit endogenous DNase activity. Moreover, we describe the formulation of various growth media, including a defined medium for metabolic studies and isolation of auxotrophic mutants. Heliobacteria are anoxygenic phototrophic bacteria with the simplest known photosynthetic apparatus. They are unique in using bacteriochlorophyll g as their main pigment and lacking a peripheral antenna system. Until now, research on this organism has been hampered by the lack of a genetic transformation system. Without such a system, gene knockouts, site-directed mutations, and gene expression studies cannot be performed to help us further understand or manipulate the organism. Here we report the genetic transformation of a heliobacterium, which should enable future genetic studies in this unique phototrophic organism.

59 BASIC BIOLOGICAL SCIENCES↗

TangibleData: Interactive Data Visualization with Mid-Air Haptics

In this paper, we investigate the effects of mid-air haptics in interactive 3D data visualization. We build an interactive 3D data visualization tool that adapts hand gestures and mid-air haptics to provide tangible interaction in VR using ultrasound haptic feedback on 3D data visualization. We consider two types of 3D visualization datasets and provide different data encoding methods for haptic representations. Two user experiments are conducted to evaluate the effectiveness of our approach. The first experimental results show that adding a mid-air haptic modality can be beneficial regardless of noise conditions and useful for handling occlusion or discerning density and volume information. The second experiment results further show the strengths and weaknesses of direct touch and indirect touch modes. Our findings can shed light on designing and implementing a tangible interaction on 3D data visualization with mid-air haptic feedback.

Bhardwaj, Ayush↗

Genome-based analysis for the bioactive potential of Streptomyces yeochonensis CN732, an acidophilic filamentous soil actinobacterium

Background: Acidophilic members of the genus Streptomyces can be a good source for novel secondary metabolites and degradative enzymes of biopolymers. In this study, a genome-based approach on Streptomyces yeochonensis CN732, a representative neutrotolerant acidophilic streptomycete, was employed to examine the biosynthetic as well as enzymatic potential, and also presence of any genetic tools for adaptation in acidic environment. Results: A high quality draft genome (7.8Mb) of S. yeochonensis CN732 was obtained with a G+C content of 73.53% and 6549 protein coding genes. The in silico analysis predicted presence of multiple biosynthetic gene clusters (BGCs), which showed similarity with those for antimicrobial, anticancer or antiparasitic compounds. However, the low levels of similarity with known BGCs for most cases suggested novelty of the metabolites from those predicted gene clusters. The production of various novel metabolites was also confirmed from the combined high performance liquid chromatography-mass spectrometry analysis. Through comparative genome analysis with related Streptomyces species, genes specific to strain CN732 and also those specific to neutrotolerant acidophilic species could be identified, which showed that genes for metabolism in diverse environment were enriched among acidophilic species. In addition, the presence of strain specific genes for carbohydrate active enzymes (CAZyme) along with many other singletons indicated uniqueness of the genetic makeup of strain CN732. The presence of cysteine transpeptidases (sortases) among the BGCs was also observed from this study, which implies their putative roles in the biosynthesis of secondary metabolites. Conclusions: This study highlights the bioactive potential of strain CN732, an acidophilic streptomycete with regard to secondary metabolite production and biodegradation potential using genomics based approach. The comparative genome analysis revealed genes specific to CN732 and also those among acidophilic species, which could give some insights into the adaptation of microbial life in acidic environment.

59 BASIC BIOLOGICAL SCIENCES↗

Combined Environments: Driving multiple loads on Z

Pulsed power drivers such as the Z generator of Sandia National Laboratories typically deliver high current (>20MA) to single experiments. This project is intended to develop and assess ways to simultaneously drive multiple targets on a single pulsed power driver (specifically a neutron and an x-ray producing target driven in a single experiment). The combined x-ray/neutron environment produced will then be used to investigate potential synergistic effects in integrated circuits. A pre-requisite for being able to design and study multiple targets on Z is first adapting simulation tools to be able to model them effectively. This will enable us to assess the tradeoffs between the different ways multiple targets can be combined, and to better understand how existing and future pulsed power machines can be used to generate combined testing environments. This report is limited to documenting the initial development of a parallel load modeling capability that is presently being applied to design experiments to produce combined neutron/x-ray environments on Z.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Portable power tool machines weld joints in field

Portable routing machine for cutting precise weld joints required by nonstandard pipe sections used in the field for transfer of cryogenic fluids. This tool is adaptable for various sizes of pipes and has a selection of router bits for different joint configurations.

Spier, R. A.↗

Expander for Thin-Wall Tubing

Tool locally expands small-diameter tubes. Tube expander locally expands and deforms tube: Compressive lateral stress induced in elastomeric sleeve by squeezing axially between two metal tool parts. Adaptable to situations in which tube must have small bulge for mechanical support or flow control.

Pessin, R.↗

Improving A Remote Manipulator

Set of three reports describes work on Protoflight Manipulator Assembly (PFMA). "Performance Characteristics of Protoflight Manipulator Assembly" presents parameters of PFMA after refurbishment of operating components. "End Effector and Task Board Development for the Protoflight Manipulator Assembly" describes special tools and adaptations allowing PFMA to be used for servicing equipment. "Modular Software Development for the Protoflight Manipulator Assembly" documents interface and control software for PFMA.

Haslam, John W., Jr.↗