Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of a broadband hard x-ray radiography platform for pulsed-power experiments

In this article, we develop and demonstrate a broadband hard x-ray radiography platform at the Zebra Pulsed Power Laboratory that integrates point-projection radiography, bremsstrahlung measurements, and hard x-ray pinhole imaging, designed to diagnose current-driven, cylindrically compressed matter. Initial laser-pulsed-power coupled experiments revealed that intense background radiation generated during 1 MA Zebra current shots overwhelmed laser-produced hard x-rays, obscuring radiographic images. Using combined spectral and spatial diagnostics, we identify energetic electrons accelerated by return currents as the dominant source of background hard x-rays, with electron energies inferred to be 3–4 MeV based on Monte Carlo simulations, and demonstrate mitigation through modifications to the radiation shielding and return-current configuration. The diagnostic platform was validated using a wire-pinch hard x-ray source, allowing radiographs of static 1-mm-diameter aluminum wires to be obtained while simultaneously measuring x-ray source spectra and spatial emission distributions within a single shot. Measured wire transmission profiles were quantitatively reconstructed using radiation transport simulations that incorporate an experimentally inferred two-temperature exponential x-ray spectrum from bremsstrahlung signal analysis and spatially distributed emission sources identified by pinhole imaging. Agreement between measured and simulated transmission profiles demonstrates the validity of the radiographic and x-ray source characterization approach, establishing this diagnostic platform as a promising tool for diagnosing magnetically driven, high-density plasmas relevant to warm dense matter and inertial fusion energy research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correcting Magnetic-Field Diffusion Effects in Beam Position Monitors

Beam position monitors (BPMs) provide timeresolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). The data from some types of BPMs can be influenced by magnetic field diffusion into the surrounding metal. We derive an estimate of the correction factor from first principles, and show how it is applied in practice to nearly eliminate the effect from the data.

43 PARTICLE ACCELERATORS↗

AI-driven Neutrino Beam Diagnostics for Next-Generation Neutrino Experiments

The accelerator-driven beam uncertainty limits oscillation measurements in long-baseline neutrino experiments. Spill-resolved beam diagnostics and real-time inference are necessary to address these neutrino flux systematics. As such, we present a machine-learning-based beam monitoring framework developed and validated using data from the T2K experiment. Our approach uses downstream, spill-by-spill muon monitor observables to predict upstream parameters such as proton beam position and width. We achieve high predictive accuracy on nominal runs, demonstrating robust baseline performance whether the model is trained on stable runs or systematically varied conditions. The framework is designed to be robust against domain shifts, allowing the neural network architectures and inference strategies developed with T2K data to be retrained and validated using LBNF simulations, with the goal of eventual deployment under real LBNF/DUNE operating conditions. This scalable approach to real-time beam inference offers a pathway toward reducing flux systematics for next-generation neutrino experiments such as DUNE.

Aney, Noah [Fermilab; U. Chicago (main)]↗

Acceleration of Solvation Free Energy Calculation via Thermodynamic Integration Coupled with Gaussian Process Regression and Improved Gelman–Rubin Convergence Diagnostics

The determination of the solvation free energy of ions and molecules holds profound importance across a spectrum of applications spanning chemistry, biology, energy storage, and the environment. Molecular dynamics simulations are powerful tools for computing this critical parameter. Nevertheless, the accurate and efficient calculation of the solvation free energy becomes a formidable endeavor when dealing with complex systems characterized by potent Coulombic interactions and sluggish ion dynamics and, consequently, slow transition across various metastable states. Here, in the present study, we expose limitations stemming from the conventional calculation of the statistical inefficiency g in the thermodynamic integration method, a factor that can hinder the determination of convergence of the solvation free energy and its associated uncertainty. Instead, we propose a robust scheme based on Gelman–Rubin convergence diagnostics. We leverage this improved estimation of uncertainties to introduce an innovative accelerated thermodynamic integration method based on the Gaussian Process regression. This methodology is applied to the calculation of the solvation free energy of trivalent rare-earth elements immersed in ionic liquids, a scenario in which the aforementioned challenges render standard approaches ineffective. The proposed method proves to be effective in computing solvation free energy in situations where traditional thermodynamic integration methods fall short.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a novel bunch oscillation recorder with RFSoC technology

The SuperKEKB accelerator is designed to achieve unprecedented luminosity levels, but this goal is currently hindered by Sudden Beam Loss (SBL) events. These events not only obstruct luminosity improvement but also pose a significant risk to accelerator components, the Belle II detectors, and the superconducting focusing system, potentially leading to severe damage and quenching of the superconducting system. Here, to address this critical challenge, we have developed a novel Bunch Oscillation Recorder (BOR) based on RFSoC technology. The BOR has demonstrated high precision with a position resolution of 0.03 mm, making it a powerful tool for real-time beam monitoring. In its initial deployment, the BOR successfully recorded multiple SBL events, providing valuable data for further analysis. By strategically positioning BORs at the suspected points of SBL origin, we aim to directly identify sources of beam instability. We anticipate that this portable, high-speed BOR monitor will play a crucial role in resolving the SBL issue, ultimately helping achieve SuperKEKB's luminosity targets.

Beam diagnostics↗

Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors III: Application to DARHT-II Beam Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present experimental validation of current and position results from a prototype detector employing finite conductivity sensing areas, based on experiments on the DARHT-II LIA.

43 PARTICLE ACCELERATORS↗

Ion Channel Laser Based on Direct Laser Acceleration of a Shaped Beam Driver (Final Technical Report)

The main focus of our research was to understand the synergies between an electron bunch and a laser pulse when the two co-propagate through the plasma. We have clearly demonstrated using theoretical and computational modeling that the propagation distance of both the bunch and the laser pulse could be extended. The ability of the combined bunch/pulse system to extend the propagation distance and the size of the plasma bubble enables highly-efficient sources of relativistic electrons. As pointed out by the Plasma Decadal Study, such electron sources can be used for generating extremely bright x-rays for a variety of applications can serve as probes and diagnostics for other plasma experiments: high energy density (HED) sciences, inertial confinement fusion (ICF), and potentially Fusion Materials and Technology (FM&T). Development of advanced diagnostics of plasma-based accelerators is yet another key area identified by recent reports. Even broader security and medical applications of compact accelerator-based radiation sources, such as very high energy electron (VHEE) sources for FLASH radiobiology, have been identified by a recent multi-agency panel. A number of key technical issues were considered and successfully resolved during the course of the grant. Those include: beam loading effect of both the driver and witness bunches on the wake, laser channeling by the bunch, and the direct laser acceleration (DLA) of the driver bunch by the laser pulse. To demonstrate clear synergy, we were able to ascertain that the total energy gain of a witness bunch in the wake of the combined bunch/laser complex is large than the sum of the energy gains in the wake of the laser pulse alone, and the driver bunch alone. We have also demonstrated that not only the energy gain is improved, but the energy spread is not sacrificed. To carry out these simulations, we have to develop a range of in-house computational tools, including a fully-3D code WAND-PIC.

43 PARTICLE ACCELERATORS↗

Coronal Diagnostic Experiment (CODEX)

Understanding solar wind sources and acceleration mechanisms is an overarching solar physics goal. Current models are highly under-constrained due to the limitations of the existing data, particularly in the ~3-10 Rs range. COronal Diagnostic Experiment (CODEX) is designed to deliver the first global, comprehensive data sets that will impose crucial constraints and answer targeted essential questions, including: Are there signatures of hot plasma released into the solar wind from previously closed fields? What are the velocities and temperatures of the density structures that are observed so ubiquitously within streamers and coronal holes? To provide these crucial measurements, NASA’s Goddard Space Flight Center, in collaboration with the Korea Astronomy and Space Science Institute, and Italian National Institute for Astrophysics (INAF) will develop a next-generation coronagraph for the International Space Station. This imaging coronagraph uses multiple filters to obtain simultaneous measurements of electron density, temperature, and velocity within a single instrument. This will be the first time all three have been measured simultaneously for this critical field-of-view, and CODEX achieves these measurements multiple times a day.

Jeff Newmark↗

Magnetic-Field Diffusion Effects in Beam Position Monitors II: Application to Calibration Single-Pulse Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. From first principles, we have derived the perturbation to BPM measurements due to this effect. The theoretical framework was used to design an algorithm for signal correction that does not require knowledge of the time history of the magnetic flux being measured. Corrected signals based on that process compared favorably with the know reference signals in a laboratory calibration test sequence.

43 PARTICLE ACCELERATORS↗

DEVELOPMENT OF A QUANTUM ELECTRON BEAM DIAGNOSTIC APPARATUS

Spatial properties of electron beams are the essential parameters needed in particle physics and accelerator research. Beam characterization using optical detection methods through the interaction between photons and electrons such as Compton scattering, or electro-optic sampling of the electric field of electrons have been extensively explored and successfully implemented as non-invasive diagnostics at various accelerator facilities. However, such methods often suffer from inherently low sensitivity. Here we present the study of a new type of electron beam diagnostic device for direct optical imaging of electron beams at various energy levels. The concept is based on the extremely high sensitivity of atoms, prepared in a specific "dark superposition" quantum state, to the external electric or magnetic perturbations induced by the passing charged particle, which allows atoms to change polarization of the probe light or absorb probe light and to fluoresce, enabling direct 3D imaging of the charged particles with high resolution. We report our recent experiment results and the design effort on a compact apparatus intended to be tested with the relativistic electron beams at Jefferson Laboratory.

Zhang, S.↗

Real-Time Data Acquisition and Processing System for MHz Repetition Rate Image Sensors

An electro-optic detector is one of the diagnostic setups used in particle accelerators. It employs an electro-optic crystal to encode the longitudinal beam charge profile in the spectrum of a light pulse. The charge distribution is then reconstructed using data captured by a fast spectrometer. The measurement repetition rate should match or exceed the machine bunching frequency, which is often in the range of several MHz. A high-speed optical line detector (HOLD) is a linear camera designed for easy integration with scientific experiments. The use of modern FPGA circuits helps in the efficient collection and processing of data. The solution is based on Xilinx 7-Series FPGA circuits and implements a custom latency-optimized architecture utilizing the AXI4 family of interfaces. HOLD is one of the fastest line cameras in the world. Thanks to its hardware architecture and a powerful KALYPSO sensor from KIT, it outperforms the fastest comparable commercial devices.

MicroTCA↗

Polar 5 - An electron accelerator experiment within an aurora. I - Instrumentation and geophysical conditions

A mother-daughter rocket was launched over two auroral structures, which included a 10 keV electron accelerator and a series of diagnostic instruments for monitoring optical and wave effects generated through beam-atmospheric interactions and production of secondary electrons. The instrumentation, the ground and rocket background measurements obtained, and some of the beam effects on various geophysical parameters are presented. Attention is given to the rocket geometry, capacitance probe, particle counters, photometers, and the bremsstrahlung X-ray detector. Observations on the plasma environment, auroral particle precipitation, d.c. electric field, optical emissions, and auroral background HF and VLF emissions are also discussed.

Maehlum, B. N.↗

Effect of Background Pressure on the Performance and Plume of the HiVHAc Hall Thruster

During the Single String Integration Test of the NASA HiVHAc Hall thruster, a number of plasma diagnostics were implemented to study the effect of varying facility background pressure on thruster operation. These diagnostics include thrust stand, Faraday probe, ExB probe, and retarding potential analyzer. The test results indicated a rise in thrust and discharge current with background pressure. There was also a decrease in ion energy per charge, an increase in multiply-charged species production, a decrease in plume divergence, and a decrease in ion beam current with increasing background pressure. A simplified ingestion model was applied to determine the maximum acceptable background pressure for thrust measurement. The maximum acceptable ingestion percentage was found to be around 1%. Examination of the diagnostics results suggest the ionization and acceleration zones of the thruster were shifting upstream with increasing background pressure.

Electric propulsion↗

An Improved Beam Position Monitor for Scorpius and the DARHT Multi-Pulse Test Line

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). A frequently used BPM detector is the B-dot loop, which generates a signal from the EMF generated by the time varying magnetic flux through the loop. We have developed a second generation BPM that avoids previously observed diffusion effects in earlier stainless steel through the use of exceptionally high conductivity copper alloy for its construction.

43 PARTICLE ACCELERATORS↗

Status of the laser manipulations of H- beam at J-PARC

The laser manipulations of H- ion beam by single or double neutralization is a very promising technique and highly essential to utilized in accelerator processes such as stripping, pulse chopping, collimation, extraction, and beam diagnostics for the present and future high-intensity proton accelerators. At J-PARC, we are preparing for a POP (Proof-of-Principle) demonstration 400 MeV H- stripping by using only lasers. A prototype YAG laser system and a laser cavity system to reduce the laser power are being developed through 3 MeV H- neutralization studies. Fermilab utilizes H- neutralization at 0.75 MeV by establishing a laser Notcher system for a gap in the H- pulse needed for a clean beam extraction from the ring. To minimize the laser power and maximize the interaction efficiency are common issue at both laboratories. Under the US-Japan collaboration for high-intensity neutrino beam, we are closely working to establish recycling/reusing of seed laser pulses to reduce a size of the laser system. In parallel, we have also developed non-destructive beam diagnostic systems at lower H- energy of 3 MeV, which will be implemented to the 400 MeV as well as easily applicable to the Fermilab linac including PIP-II linac. Installation of the laser system at J-PARC linac for 400 MeV H- stripping is ongoing to start the POP experimental study in 2023.

43 PARTICLE ACCELERATORS↗

Self-driven ion deflectometry measurements using MeV fusion-driven protons and accelerated deuterons in the deuterated hybrid x-pinch on the MAIZE LTD generator

Abstract We report on the results of point-projection ion deflectometry measurements from a mid-size university z-pinch experiment. A 1 MA 8 kJ LTD generator at the University of Michigan (called MAIZE) drove a hybrid x-pinch (HXP) with a deuterated polyethylene fiber load to produce a point-like source of MeV ions for backlighting. In these experiments, 2.7 MeV protons were generated by DD beam-target fusion reactions. Due to the kinematics of beam-target fusion, the proton energies were down-shifted from the more standard 3.02 MeV proton energy that is released from the center-of-mass rest frame of a DD reaction. In addition to the 2.7 MeV protons, strongly anisotropic beams of 3 MeV accelerated deuterons were detected by ion diagnostics placed at a radial distance of 90 mm from the x-pinch. Numerical reconstruction of experimental data generated by deflected hydrogen ion trajectories evaluated the total current in the vacuum load region. Numerical ion-tracking simulations show that accelerated deuteron beams exited the ion source region at large angles with respect to the pinch current direction.

Physics↗

Efficient fault diagnosis of helicopter gearboxes

Application of a diagnostic system to a helicopter gearbox is presented. The diagnostic system is a nonparametric pattern classifier that uses a multi-valued influence matrix (MVIM) as its diagnostic model and benefits from a fast learning algorithm that enables it to estimate its diagnostic model from a small number of measurement-fault data. To test this diagnostic system, vibration measurements were collected from a helicopter gearbox test stand during accelerated fatigue tests and at various fault instances. The diagnostic results indicate that the MVIM system can accurately detect and diagnose various gearbox faults so long as they are included in training.

Chin, H.↗