Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

First results from a high-frame-rate, multi-GHz ionizing particle detection system geared toward accelerator diagnostic applications

An integrated detection system, consists of a thin diamond sensor incorporated into a compact signal loop, coupled in turn to an application-specific integrated circuit readout chip, has been tested for the first time, using ps-duration electron pulses from the Next Linear Collider Test Accelerator at the SLAC National Accelerator Laboratory. For readout frame rates as high as 120 kHz, the detection system is shown to achieve a linear dynamic range of 10 3 and a bandwidth of 4–5 GHz, with no ringing seen on the tail of the output pulse. These results represent the best-performing multi-GHz ionizing particle detection system achieved to date.

Ferezghi, Mohammadreza Mohseni [University of Cali↗

Performance Analysis of Memory Transfers and GEMM Subroutines on NVIDIA Tesla GPU Cluster

Commodity clusters augmented with application accelerators are evolving as competitive high performance computing systems. The Graphical Processing Unit (GPU) with a very high arithmetic density and performance per price ratio is a good platform for the scientific application acceleration. In addition to the interconnect bottlenecks among the cluster compute nodes, the cost of memory copies between the host and the GPU device have to be carefully amortized to improve the overall efficiency of the application. Scientific applications also rely on efficient implementation of the BAsic Linear Algebra Subroutines (BLAS), among which the General Matrix Multiply (GEMM) is considered as the workhorse subroutine. In this paper, they study the performance of the memory copies and GEMM subroutines that are critical to port the computational chemistry algorithms to the GPU clusters. To that end, a benchmark based on the NetPIPE framework is developed to evaluate the latency and bandwidth of the memory copies between the host and the GPU device. The performance of the single and double precision GEMM subroutines from the NVIDIA CUBLAS 2.0 library are studied. The results have been compared with that of the BLAS routines from the Intel Math Kernel Library (MKL) to understand the computational trade-offs. The test bed is a Intel Xeon cluster equipped with NVIDIA Tesla GPUs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ferroelectric Based Technologies for Accelerators

Ferroelectrics have unique intrinsic properties that make them extremely attractive for high-energy accelerator applications. Low loss ferroelectric materials can be used as key elements in RF tuning and phase shifting components to provide fast, electronic control. These devices are under development for different accelerator applications for the X, Ka and L-frequency bands. The exact design of these devices depends on the electrical parameters of the particular ferroelectric material to be used--its dielectric constant, loss tangent and tunability. BST based ferroelectric-oxide compounds have been found to be suitable materials for a fast electrically-controlled tuners. We present recent results on the development of BST based ferroelectric compositions synthesized for use in high power technology components. The BST(M) ferroelectrics have been tested using both transverse and parallel dc bias fields to control the permittivity. Fast switching of a newly developed material has been shown and the feasibility of using of ferroelectric-based accelerator components in vacuum and in air has been demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cathode R&D for future light sources

This paper reviews the requirements and current status of cathodes for accelerator applications, and proposes a research and development plan for advancing cathode technology. Accelerator cathodes need to have long operational lifetimes and produce electron beams with a very low emittance. The two principal emission processes to be considered are thermionic and photoemission with the photocathodes being further subdivided into metal and semi-conductors. Field emission cathodes are not included in this analysis. The thermal emittance is derived and the formulas used to compare the various cathode materials. To date, there is no cathode which provides all the requirements needed for the proposed future light sources. Therefore a three part research plan is described to develop cathodes for these future light source applications.

43 PARTICLE ACCELERATORS↗

Performance modeling of microsecond scale biological molecular dynamics simulations on heterogeneous architectures

Performance improvements in biomolecular simulations based on molecular dynamics (MD) codes are widely desired. Unfortunately, the factors, which allowed past performance improvements, particularly the microprocessor clock frequencies, are no longer increasing. Hence, novel software and hardware solutions are being explored for accelerating performance of widely used MD codes. In this paper, we describe our efforts on porting, optimizing and tuning of Large-scale Atomic/Molecular Massively Parallel Simulator, a popular MD framework, on heterogeneous architectures: multi-core processors with graphical processing unit (GPU) accelerators. Our implementation is based on accelerating the most computationally expensive non-bonded interaction terms on the GPUs and overlapping the computation on the CPU and GPUs. This functionality is built on top of message passing interface that allows multi-level parallelism to be extracted even at the workstation level with the multi-core CPUs and allows extension of the implementation on GPU-enabled clusters. We hypothesize that the optimal benefit of heterogeneous architectures for applications will come by utilizing all possible resources (for example, CPU-cores and GPU devices on GPU-enabled clusters). Benchmarks for a range of biomolecular system sizes are provided, and an analysis is performed on four generations of NVIDIA's GPU devices. On GPU-enabled Linux clusters, by overlapping and pipelining computation and communication, we observe up to 10-folds application acceleration in multi-core and multi-GPU environments illustrating significant performance improvements. Detailed analysis of the implementation is presented that allows identification of bottlenecks in algorithm, indicating that code optimization and improvements on GPUs could allow microsecond scale simulation throughput on workstations and inexpensive GPU clusters, putting widely desired biologically relevant simulation time-scales within reach of a large user community. In order to systematically optimize simulation throughput and to enable performance prediction, we have developed a parameterized performance model that will allow developers and users to explore the performance potential of future heterogeneous systems for biological simulations.

Agarwal, Pratul K.↗

Low energy beam transport system developments

For high brightness beam production it is important to preserve the brightness in the low energy beam transport system (LEBT) used to transport and match the ion beams to the next stage of acceleration, usually an RFQ. While electrostatic focusing can be problematic for high current beam transport, reliable electrostatic LEBT operation has been demonstrated with H{sup −} beams up to 60 mA. Now, however, it is commonly accepted that an optimal LEBT for high current accelerator applications consists of focusing solenoids with space charge compensation. Two-solenoid LEBTs are successfully used for high current (>100 mA) proton beam transport. Preservation of low emittances (~0.15 π mm-mrad) requires the addition of a heavy gas (Xe, Kr), which causes ~5% of proton loss in a 1 m long LEBT. Similar Xe densities would be required to preserve low emittances of H{sup −} beams, but such gas densities cause unacceptably high H{sup −} beam losses. A short LEBT with only one short solenoid, movable for RFQ matching, can be used for reduced negative ion stripping. A strong electrostatic-focusing LEBT has been successfully adopted for transport of high current H{sup −} beams in the SNS Front End. Some modifications of such electrostatic LEBTs are expected to improve the reliable transport of intense positive and negative ion beams without greatly degrading their low emittances. We concentrate on processes that determine the beam brightness degradation and on their prevention. Proposed improvements to the SNS electrostatic LEBT are discussed.

43 PARTICLE ACCELERATORS↗

FAIR principles for AI models with a practical application for accelerated high energy diffraction microscopy

Abstract A concise and measurable set of FAIR (Findable, Accessible, Interoperable and Reusable) principles for scientific data is transforming the state-of-practice for data management and stewardship, supporting and enabling discovery and innovation. Learning from this initiative, and acknowledging the impact of artificial intelligence (AI) in the practice of science and engineering, we introduce a set of practical, concise, and measurable FAIR principles for AI models. We showcase how to create and share FAIR data and AI models within a unified computational framework combining the following elements: the Advanced Photon Source at Argonne National Laboratory, the Materials Data Facility, the Data and Learning Hub for Science, and funcX, and the Argonne Leadership Computing Facility (ALCF), in particular the ThetaGPU supercomputer and the SambaNova DataScale ® system at the ALCF AI Testbed. We describe how this domain-agnostic computational framework may be harnessed to enable autonomous AI-driven discovery.

47 OTHER INSTRUMENTATION↗

Calorimetric low temperature detectors for low-energetic heavy ions and their application in accelerator mass spectrometry

The energy-sensitive detection of heavy ions with calorimetric low temperature detectors was investigated in the energy range of E=0.1-1 MeV/amu, commonly used for accelerator mass spectrometry (AMS). The detectors used consist of sapphire absorbers and superconducting aluminum transition edge thermometers operated at T{approx}1.5 K. They were irradiated with various ion beams ({sup 13}C,{sup 197}Au,{sup 238}U) provided by the VERA tandem accelerator in Vienna, Austria. The relative energy resolution obtained was {Delta}E/E=(5-9)x10{sup -3}, even for the heaviest ions such as {sup 238}U. In addition, no evidence for a pulse height defect was observed. This performance allowed for the first time to apply a calorimetric low temperature detector in an AMS experiment. The aim was to precisely determine the isotope ratio of {sup 236}U/{sup 238}U for several samples of natural uranium, {sup 236}U being known as a sensitive monitor for neutron fluxes. Replacing a conventionally used detection system at VERA by the calorimetric detector enabled to substantially reduce background from neighboring isotopes and to increase the detection efficiency. Due to the high sensitivity achieved, a value of {sup 236}U/{sup 238}U=6.1x10{sup -12} could be obtained, representing the smallest {sup 236}U/{sup 238}U ratio measured at the time. In addition, we contributed to establishing an improved material standard of {sup 236}U/{sup 238}U, which can be used as a reference for future AMS measurements.

43 PARTICLE ACCELERATORS↗

Status and future plans for C 3 R&D

C 3 is an opportunity to realize an e + e - collider for the study of the Higgs boson at √s = 250 GeV, with a well defined upgrade path to 550 GeV while staying on the same short facility footprint. C 3 is based on a fundamentally new approach to normal conducting linear accelerators that achieves both high gradient and high efficiency at relatively low cost. Given the advanced state of linear collider designs, the key system that requires technical maturation for C 3 is the main linac. This paper presents the staged approach towards a facility to demonstrate C 3 technology with both Direct (source and main linac) and Parallel (beam delivery, damping ring, ancillary component) R&D. The primary goal of the C 3 Demonstration R&D Plan is to reduce technical and cost risk by building and operating the key components of C 3 at an adequate scale. This R&D plan starts with the engineering design, and demonstration of one cryomodule and will culminate in the construction of a 3 cryomodule linac with pre-production prototypes. This R&D program would also demonstrate the linac rf fundamentals including achievable gradient and gradient stability over a full electron bunch train and breakdown rates. It will also investigate beam dynamics including energy spread, wakefields, and emittance growth. This work will be critical to confirm the suitability of the C 3 beam parameters for the physics reach and detector performance in preparation for a Conceptual Design Report (CDR), as well as for follow-on technology development and industrialization. The C 3 Demonstration R&D Plan will open up significant new scientific and technical opportunities based on development of high-gradient and high-efficiency accelerator technology. It will push this technology to operate both at the GeV scale and mature the technology to be reliable and provide high-brightness electron beams. The timeline for progressing with C 3 technology development will be governed by practical limitations on both the technical progress and resource availability. It consists of four stages: Stage 0) Ongoing fundamental R&D on structure prototypes, damping and vibrations. Stage 1) Advancing the engineering maturity of the design and developing start-to-end simulations including space-charge and wakefield effects. This stage will include testing of strucutres operating at cryogenic temperatures. Beam tests would be performed with high beam current to test full beam loading. Stage 2) Production and testing of the first cryomodule at cryogenic temperatures. This would provide sufficient experimental data to compile a CDR and it is anticipated for Stage 2 to last 3 years and to culminate with the transport of photo-electrons through the first cryomodule. Stage 3) Updates to the engineering design of the cryomodules, production of the second and third cryomodule and their installation. Lower charge and lower emittance beams will be used to investigate emittance growth. The successful full demonstration of the 3 cryomodules to deliver up to a 3 GeV beam and achieve the C 3 five gradient will allow a comprehensive and robust evaluation of the technical design of C 3 as well as mitigate technical, schedule, and cost risks required to proceed with a Technical Design Report (TDR).

radiation hardened magnets↗

Accelerating Parallel Applications in Cloud Platforms via Adaptive Time-Slice Control

Cloud platforms can provide flexible and cost-effective environments for parallel applications. However, the resource over-commitment issues, i.e., cloud providers often provide much more executable virtual CPUs than available physical CPUs, still impede the synchronization operations of parallel applications, causing severe performance degradation. Existing methods optimize parallel applications by promoting the priorities of involved VMs. They cannot fully explore the performance of parallel applications, because they ignore the time-slice requirements of different phases of parallel applications. Furthermore, non-parallel applications experience unsatisfied performance because of low scheduling priorities. Given empirical analysis on time-slices of virtual machines (VMs), we find that shortening time-slices can mitigate synchronization overhead which incurs during communication phases, while over-short time-slices cause frequent cache misses in computation phases. Accordingly, we propose an Adaptive Time-slice Control (ATC) mechanism. ATC first detects the phases of parallel applications based on lock latency or cache misses. Then, ATC shortens time-slices during communication phases and prolongs time-slices during computation phases for parallel applications, and sets a uniform time-slice for non-parallel applications. Finally, we evaluate ATC using seven well-known benchmarks with 25+ applications. Experiments show that ATC obtains 1.5-75x performance gain for running parallel applications than state-of-the-art solutions, with nearly unaffected impact on non-parallel applications.

97 MATHEMATICS AND COMPUTING↗

Object Proxy Patterns for Accelerating Distributed Applications

Workflow and serverless frameworks have empowered new approaches to distributed application design by abstracting compute resources. However, their typically limited or one-size-fits-all support for advanced data flow patterns leaves optimization to the application programmer—optimization that becomes more difficult as data become larger. The transparent object proxy, which provides wide-area references that can resolve to data regardless of location, has been demonstrated as an effective low-level building block in such situations. Here we propose three high-level proxy-based programming patterns—distributed futures, streaming, and ownership—that make the power of the proxy pattern usable for more complex and dynamic distributed program structures. We motivate these patterns via careful review of application requirements and describe implementations of each pattern. As a result, we evaluate our implementations through a suite of benchmarks and by applying them in three meaningful scientific applications, in which we demonstrate substantial improvements in runtime, throughput, and memory usage.

Distributed Computing↗

TH-C-12A-09: Planning and Delivery of the Fully Dynamic Trajectory Modulated Arc Therapy: Application to Accelerated Partial Breast Irradiation

Purpose: A novel trajectory modulated arc therapy (TMAT) system was developed that uses source motion trajectory involving synchronized gantry rotation with translational and rotational couch movement. MLC motion and dose rate were fully optimized for dynamic beam delivery. This work presents a platform for planning deliverable TMAT on a collision free coronal trajectory and evaluates its benefit for accelerated partial breast irradiation (APBI) in a prone position. Methods: The TMAT algorithm was built on VMAT with modifications (physical properties on couch movement were defined) and enhancements (pencil beam dose calculation engine to support extended SSDs) to make it feasible for TMAT delivery. A Matlab software environment for TMAT optimization and dose calculation was created to allow any user specified motion axis. TMAT delivery was implemented on Varian TrueBeamTM STx via XML scripts. 10 prone breast irradiation cases were evaluated in VMAT and compared with a 6- field non-coplanar IMRT plan. Patient selection/exclusion criteria and structure contouring followed the guidelines of NSABP B-39/RTOG 0413 protocol. Results: TMAT delivery time was ∼4.5 minutes. 251.5°±7.88° of non-isocentric couch arc was achieved by the optimized trajectory with 180– 210 control points at 1°–2° couch increments. The improved dose distribution by TMAT was most clearly observed by the marked reduction in the volume of irradiated normal breast tissue in the high dose region. The ratios of the normal breast tissue volume receiving more than 50%, 80% and 100% of the prescription dose for TMAT versus IMRT were: V50%(TMAT/IMRT) = 78.38%±13.03%, V80%(TMAT/IMRT) = 44.19%±9.04% and V100% (TMAT/IMRT) = 9.96%±7.55%, all p≤0.01. Conclusion: The study is the first demonstration of planning and delivery implementation of a fully dynamic APBI TMAT system with continuous couch motion. TMAT achieved significantly improved dosimetry over noncoplanar IMRT on dose volume parameters correlated with toxicity and cosmetic outcome of APBI. This project was supported by Varian Research Grant.

60 APPLIED LIFE SCIENCES↗

Probabilistic data fusion and physics-informed machine learning: A new paradigm for modeling under uncertainty, and its application to accelerating the discovery of new materials

In this report we summarize the work conducted by PI Perdikaris and his group under this Early Career project DE–SC0019116 during the period of 09/01/2018 – 08/31/2023. The central aim of the work was to introduce a new paradigm for scientific data analysis that can seamlessly synthesize rigorous mathematical modeling with data of variable fidelity (e.g., measurements at multiple scales/resolutions or predictions of variable fidelity models) and multiple modalities (e.g., images, time–series, or scattered measurements). The setting we are interested in involves complex systems that are partially observed and whose dynamical behavior could be hard to model or totally unknown. The inherent uncertainty associated with this setting necessitates a departure from the classical deterministic realm of modeling and scientific computation, and, consequently, our main building blocks can no longer be crisp deterministic numbers and governing laws, but instead we must operate with probabilistic models.

97 MATHEMATICS AND COMPUTING↗