Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “YO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Genome Sequences of Bacteria Isolated from the International Space Station Water Systems

We report draft genomes of five bacteria recovered from the United States and Russian water systems onboard the International Space Station: bacteria of the genera Ralstonia, Burkholderia, Cupriavidus, Methylobacterium, and Pseudomonas. These sequences will help further the understanding of water reclamation and environmental control and life support systems in space.

Christian L. Castro↗

Development and Testing of a New Partial Gravity Urine Processor Design and Urine Pretreatment

The Planetary Urine Processor (PUP) is a urine distillation system for lunar or planetary applications, taking advantage of local gravity for phase separation as well as the movement and storage of waste feeds and distillate. The PUP utilizes a stationary evaporator with an integrated disposable bag to process urine and capture remaining precipitates. This system aims to increase water reclamation percentage to greater than 96%, reduce resource requirements, and enhance reliability and maintainability due to lower system complexity over the existing water recovery system on the International Space Station (ISS). This paper focuses on the hardware development, testing efforts, and the associated urine pretreatment development work.

Water Recovery↗

Analysis of CDC Bioreactor Internal Thermal Measurements and Sample Coupon Temperatures

The Center for Disease Control and Prevention (CDC) bioreactor is an integral laboratory tool for the Environmental Control and Life Support Systems (ECLSS) biofilm formation and growth research program. Critical to this research is the need to adjust and maintain various surface temperatures of the coupons housed within the CDC Bioreactor. The purpose of this study was to provide quantitative temperature gradient information when the CDC Bioreactor was operating according to several process scenarios. Two primary process parameters were evaluated. For the first set of test parameters, the liquid level was maintained at 350 mL, with an inlet flowrate of 0.1 mL/min, 1 mL/min, 10 mL/min. The liquid was allowed to gravity drain out of the outlet spout. For the second set of test parameters, the liquid level within the reactor was maintained at 550 mL, with an inlet flow of 0.1 mL/min, 1 mL/min, 10 mL/min and draining intermittently controlled to 0.8 mL/min to maintain the 550 mL level. Due to the placement of the thermocouple in the reactor, a difference in temperature occurred between the coupon surfaces and target Bioreactor temperature when operated according to the first set of test parameters. When the reactor was operated according to the second set of parameters, which resulted in the thermocouple being submerged, the temperature gradient was eliminated. The results demonstrated minimal temperature gradient between the top and bottom coupon surfaces for coupons placed in a single rod within the CDC Bioreactor for both sets of test parameters evaluated. The collection of this information helped to explain previous ECLSS biofilm formation test runs, along with providing guidance on best operating practices for future ECLSS experiments. The placement of the thermocouple also helps to explain the challenge of achieving and maintaining bulk liquid temperatures when biofilm is grown according to the standardized test methods.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

Potential Biofilm Control Strategies for Extended Spaceflight Missions

Biofilms, surface-adherent microbial communities, are associated with microbial fouling and corrosion in terrestrial water-distribution systems. Biofilms are also present in human spaceflight, particularly in the Water Recovery System (WRS) on the International Space Station (ISS). The WRS is comprised of the Urine Processor Assembly (UPA) and the Water Processor Assembly (WPA) which together recycles wastewater from human urine and recovered humidity from the ISS atmosphere. These wastewaters and various process streams are continually inoculated with microorganisms primarily arising from the space crew microbiome. Biofilm-related fouling has been encountered and addressed in spacecraft in low Earth orbit, including ISS and the Russian Mir Space Station. However, planned future missions beyond low Earth orbit to the Moon and Mars present additional challenges, as resupplying spare parts or support materials would be impractical and the mission timeline would be in the order of years in the case of a mission to Mars. In addition, future missions are expected to include a period of dormancy in which the WRS would be unused for an extended duration. The concepts developed in this review arose from a workshop including NASA personnel and representatives with biofilm expertise from a wide range of industrial and academic backgrounds. Here, we address current strategies that are employed on Earth for biofilm control, including antifouling coatings and biocides and mechanisms for mitigating biofilm growth and damage. These ideas are presented in the context of their applicability to spaceflight and identify proposed new topics of biofilm control that need to be addressed in order to facilitate future extended, crewed, spaceflight missions.

Luis Zea↗

Development and Testing of a New Partial Gravity Urine Processor Design and Urine Pretreatment

The Planetary Urine Processor (PUP) is a urine distillation system for lunar or planetary applications, taking advantage of local gravity for phase separation as well as the movement and storage of waste feeds and distillate. The PUP utilizes a stationary evaporator with an integrated disposable bag to process urine and capture remaining precipitates. This system aims to increase water reclamation percentage to greater than 96%, reduce resource requirements, and enhance reliability and maintainability due to lower system complexity over the existing water recovery system on the International Space Station (ISS). This paper focuses on the hardware development, testing efforts, and the associated urine pretreatment development work.

Water Recovery↗

Update to Developing a Multi-bioreactor Test Stand for the Evaluation of Biofilm Mitigation Technologies

Biofilm formation in spacecraft wastewater systems is a complex and impactful problem. Biomass flowing in these wastewater systems can cause clogging, higher differential pressures, and flow restrictions impacting equipment reliability and function. To explore this issue, the Marshall Space Flight Center’s biofilm test stand was created and has been utilized to examine multiple biofilm mitigation techniques over a long duration test time. This paper is an update to a previous paper, ICES-2021-122, and will serve to discuss the modifications and enhancements to the biofilm test stand. While the previous configuration tested heat treatments and coatings, this phase of testing will examine differing materials, competing bacteria provided by an external bioreactor, a prototype phytoremediation unit, and additional testing with a nutrient filter. Configuration changes include the addition of float switches, adjustment of the drain assembly architecture and additional support hardware for the competing bacteria bioreactor and phytoremediation units.

ECLSS↗

Biofilm Mitigation Testing Phase III

Biofilm is produced from bacterial or fungal organisms that can survive in extreme conditions. The microorganisms attach themselves to surfaces and produce an extracellular polymeric matrix that develops into a community structure and ecosystem. Biofilm has been known to cause blockage and clogging inside the Water Processor Assembly (WPA) and Water Recovery System (WRS) piping. The WPA and WRS on the International Space Station (ISS) is responsible for recycling humidity condensate and urine distillate to produce potable water for the astronauts to survive. The Environmental Control and Life Support System (ECLSS) department is developing a way to mitigate biofilm accumulation inside the wastewater tank.

Biofilm↗

More Than a Decade of International Space Station Microbial Sampling in the Environmental Control and Life Support Systems

Microbial monitoring has taken place in major units belonging to the Environmental Control and Life Support Systems (ECLSS) of the International Space Station (ISS). For at least a decade multiple modules including US and RU segments were sampled. In the US ECLSS, water reclamation and air systems combine their microbial contents downstream where biofilm incidents have been recorded. Understanding the microbial contents of segments provides a longitudinal perspective to microbiome changes in the system that contribute to this issue. The US ECLSS have been consistently sampled, especially in the Potable Water Bus (PWB) where bacteria from upstream sources have been observed.

Yo-Ann Velez Justiniano↗

Update to Developing a Multi-bioreactor Test Stand for the Evaluation of Biofilm Mitigation Technologies

Biofilm formation in spacecraft wastewater systems is a complex and impactful problem. Biomass flowing in these wastewater systems can cause clogging, higher differential pressures, and flow restrictions impacting equipment reliability and function. To explore this issue, the Marshall Space Flight Center’s biofilm test stand was created and has been utilized to examine multiple biofilm mitigation techniques over a long duration test time. This paper is an update to a previous paper, ICES-2021-122, and will serve to discuss the modifications and enhancements to the biofilm test stand. While the previous configuration tested heat treatments and coatings, this phase of testing will examine differing materials, competing bacteria provided by an external bioreactor, a prototype phytoremediation unit, and additional testing with a nutrient filter. Configuration changes include the addition of float switches, adjustment of the drain assembly architecture and additional support hardware for the competing bacteria bioreactor and phytoremediation units.

ECLSS↗

Ground Test Validations for Uncrewed Dormancy Preparation and Recovery

In future long duration space flight and habitation missions, periods of uncrewed dormancy where life support systems are shutdown or in low power-modes will occur. To examine the impacts of these dormant periods, along with potential pre- and post-dormancy procedures, Marshall Space Flight Center has been building an uncrewed dormancy test stand. The uncrewed dormancy test stand will include a urine separator from the Universal Waste Management System, a condensate separator, urine filter, brine filter and distillate filter. In conjunction to the test stand, the Center for Biofilm Engineering (CBE) has ongoing long-term dormancy experiments to assess microbial survival in a variety of simulated shutdown procedures including shut-in, flushing with and without biocide, and dry-out conditions. This publication will serve as a discussion of dormancy considerations, criteria for success, and experimental designs for testing dormancy conditions and shutdown procedures. It will include an update of ongoing test stand construction, including a description of the current lower-fidelity versions of the urine and condensate separators being produced. It will also examine dormancy work being conducted by the CBE and discuss how this may factor into procedures tested on the uncrewed dormancy test stand.

Eric Beitle↗

More Than a Decade of International Space Station Microbial Sampling in the Environmental Control and Life Support Systems

Microbial monitoring has taken place in major units belonging to the Environmental Control and Life Support Systems (ECLSS) of the International Space Station (ISS). For at least a decade multiple modules including US and RU segments were sampled. In the US ECLSS, water reclamation and air systems combine their microbial contents downstream where biofilm incidents have been recorded. Understanding the microbial contents of segments provides a longitudinal perspective to microbiome changes in the system that contribute to this issue. The US ECLSS have been consistently sampled, especially in the Potable Water Bus (PWB) where bacteria from upstream sources have been observed.

Yo-Ann Velez Justiniano↗

Update to Developing a Multi-bioreactor Test Stand for the Evaluation of Biofilm Mitigation Technologies

Biofilm formation in spacecraft wastewater systems is a complex and impactful problem. Biomass flowing in these wastewater systems can cause clogging, higher differential pressures, and flow restrictions impacting equipment reliability and function. To explore this issue, the Marshall Space Flight Center’s biofilm test stand was created and has been utilized to examine multiple biofilm mitigation techniques over a long duration test time. This paper is an update to a previous paper, ICES-2021-122, and will serve to discuss the modifications and enhancements to the biofilm test stand. While the previous configuration tested heat treatments and coatings, this phase of testing will examine differing materials, competing bacteria provided by an external bioreactor, a prototype phytoremediation unit, and additional testing with a nutrient filter. Configuration changes include the addition of float switches, adjustment of the drain assembly architecture and additional support hardware for the competing bacteria bioreactor and phytoremediation units.

ECLSS↗