At least 127 records · Page 7

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of ${\sim }10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7–10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5–7.0 keV), we resolved the inner-shell lines of Fe XIX-XXVI as well as the outer-shell lines of Fe XXV-XXVI . These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1–10 keV (roughly 10–100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

Astronomy and AstroPhysics↗

The development of a high-resolution Eulerian radiation-hydrodynamics simulation capability for laser-driven Hohlraums

Hohlraums are hollow cylindrical cavities with high-Z material walls used to convert laser energy into uniform x-ray radiation drives for inertial confinement fusion capsule implosions and high energy density physics experiments. Credible computational modeling of hohlraums requires detailed modeling and coupling of laser physics, hydrodynamics, radiation transport, heat transport, and atomic physics. We report on improvements to Los Alamos National Laboratory's xRAGE radiation-hydrodynamics code in order to enable hohlraum modeling. xRAGE's Eulerian hydrodynamics and adaptive mesh refinement make it uniquely well suited to study the impacts of multiscale features in hohlraums. In order to provide confidence in this new modeling capability, we demonstrate xRAGE's ability to produce reasonable agreement with data from several benchmark hohlraum experiments. We also use xRAGE to perform integrated simulations of a recent layered high density carbon capsule implosion on the National Ignition Facility in order to evaluate the potential impacts of the capsule support tent, mixed cell conductivity methodologies, plasma transport, and cross-beam energy transfer (XBT). We find that XBT, seeded by plasma flows in the laser entrance hole (LEH), causes a slight decrease in energy coupling to the capsule and that all of these impact the symmetry of the x-ray drive such that they have an appreciable impact on the capsule implosion shape.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mast1 mediates radiation-induced gastric injury via the P38 MAPK pathway

Radiation-induced gastric injury is a serious adverse effect and reduces the efficacy of radiotherapy treatment. However, the mechanisms underlying radiation-induced stomach injury remain unclear. Here, mouse stomach and gastric epithelial cells were irradiated with different doses of X-ray radiation. The results showed that radiation induced gastric injury in vivo and in vitro. Differentially expressed functional mRNAs in irradiation-induced gastric tissues were screened from the Gene Expression Omnibus (GEO) database. We found that the expression of microtubule-associated serine/threonine kinase 1 (Mast1) was downregulated in mouse gastric tissues and gastric epithelial cells after irradiation. Furthermore, functional assays showed that knockdown of Mast1 inhibited growth and promoted apoptosis in gastric epithelial cells, while overexpression of Mast1 protected gastric epithelial cells from radiation damage. Mechanistically, Mast1 negatively regulated radiation-induced injury in gastric epithelial cells by inhibiting the activation of P38. The apoptosis caused by knockdown of Mast1 in gastric epithelial cells could be partially reversed by the P38 inhibitor SB203580. Moreover, data from several gastric cancer cell lines and online databases revealed that Mast1 was not involved in the development of gastric cancer. Collectively, our findings demonstrated that Mast1 is essential for radiation-induced gastric injury, providing a promising prognostic and therapeutic target.

60 APPLIED LIFE SCIENCES↗

High-yield implosion modeling using the Frustraum: Assessing and controlling the formation of polar jets and enhancing implosion performance with applied magnetization

Frustraums have a higher laser-to-capsule x-ray radiation coupling efficiency and can accommodate a large capsule, thus potentially generating a higher yield with less laser energy than cylindrical Hohlraums for a given Hohlraum volume [Amendt et al., Phys. Plasmas 26, 082707 (2019]. Frustraums are expected to have less m = 4 azimuthal asymmetries arising from the intrinsic inner-laser-beam geometry on the National Ignition Facility. An experimental campaign at Lawrence Livermore National Laboratory to demonstrate the high-coupling efficiency and radiation symmetry tuning of the Frustraum has been under way since 2021. Simulations benchmarked against experimental data show that implosions using Frustraums can achieve more yield with higher ignition margins than cylindrical Hohlraums using the same laser energy. Hydrodynamic jets in capsules along the Hohlraum axis, driven by radiation-flux asymmetries in a Hohlraum with a gold liner on a depleted uranium (DU) wall, are present around stagnation, and these “polar” jets can cause severe yield degradation. The early-time Legendre mode P4<0 radiation-flux asymmetry is a leading cause of these jets, which can be reduced by using an unlined DU Hohlraum because the shape of the shell is predicted to be more prolate. Magnetization can increase the implosion robustness and reduce the required hotspot ρR for ignition; therefore, magnetizing the Frustraum can maintain the same yield while reducing the required laser energy or increase the yield using the same laser energy—all under the constraint that the ignition margin is preserved. Reducing polar jets is particularly important for magnetized implosions because of the intrinsic toroidal hotspot ion temperature topology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficient Optimization of Plasma Radiation Detector Configurations using Imperfect Inference Models

The configurations of instruments fielded on an experiment affect the amount of information captured and the quality of subsequent inference. Here, we investigate the problem of optimizing plasma x-ray radiation detectors in a magneto-inertial fusion experiment at Sandia National Laboratories. It is impossible to directly measure properties such as the temperature of the thermonuclear fusion plasma produced in these experiments because of the extreme environment and destructive nature of the experiment. Among other diagnostics, several detectors are placed with significant standoff from the fusion target to capture the x-rays emitted by the fusion plasma, which can be used to infer some of its properties. To optimize the configuration of these detectors, a high-fidelity model (HFM) is used for simulating outputs and a low-fidelity model (LFM) is used for inference. We develop methods based on A- and L-optimality criteria that are efficient to compute while explicitly accounting for the discrepancy between the HFM and the LFM. The method allows us to find detector configurations that perform similarly to or better than the configuration obtained using an existing sampling-based optimization method while decreasing computational time by a factor of 50. Supplementary materials for this article are available online, including a standardized description of the materials available for reproducing the work.

Bayesian optimization↗

Characterization of the image plate multi-scan response to mono-energetic x-rays

Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.

Instruments & Instrumentation↗

Study of perovskite CsPbBr 3 detector polarization and its mitigation with ultrahigh x-ray flux

High-flux capable semiconductor x-ray detectors are essential in various applications, but the detrimental effects of detector polarization limit their use in many cases. Here, for this work, we studied the polarization of perovskite CsPbBr 3 semiconductor detectors using ultrahigh flux synchrotron x rays (10 6 –10 12 photons s –1 mm –2 at 58.61 keV). The CsPbBr 3 detectors did not show immediate polarization prominently until a flux higher than 10 10 photons s –1 mm –2 . Using the pump-and-probe technique, we visualized the spatial and temporal effects of polarization. The polarized region, represented by reduced photocurrent, extended beyond the area under direct irradiation, and the reduced photocurrent persisted after potential de-polarization treatments. We found that stronger applied electric fields and fewer carrier traps can mitigate polarization, represented by less photocurrent deficit. By examining the detectors’ current response under controlled ambient light, low, and high-flux x rays, we studied the trap filling and release behavior of CsPbBr 3 . We discovered that the polarization is caused by partial detector damage due to deep defects generated by ultrahigh flux x-ray irradiation. Our work provides insight into CsPbBr 3 polarization under extremely intense x-ray radiation and shows that reducing crystal defects and increasing detector bias voltage are effective solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evidence for X-Ray Emission in Excess to the Jet-afterglow Decay 3.5 yr after the Binary Neutron Star Merger GW 170817: A New Emission Component

For the first ~3 yrs after the binary neutron star merger event GW 170817, the radio and X-ray radiation has been dominated by emission from a structured relativistic off-axis jet propagating into a low-density medium with n < 0.01 cm -3 . We report on observational evidence for an excess of X-ray emission at δt > 900 days after the merger. With L x ≈ 5 × 10 38 erg s -1 at 1234 days, the recently detected X-ray emission represents a ≥ 3.2σ (Gaussian equivalent) deviation from the universal post-jet-break model that best fits the multiwavelength afterglow at earlier times. In the context of JetFit afterglow models, current data represent a departure with statistical significance ≥ 3.1σ, depending on the fireball collimation, with the most realistic models showing excesses at the level of ≥ 3.7σ. A lack of detectable 3 GHz radio emission suggests a harder broadband spectrum than the jet afterglow. These properties are consistent with the emergence of a new emission component such as synchrotron radiation from a mildly relativistic shock generated by the expanding merger ejecta, i.e., a kilonova afterglow. In this context, we present a set of ab initio numerical relativity binary neutron star (BNS) merger simulations that show that an X-ray excess supports the presence of a high-velocity tail in the merger ejecta, and argues against the prompt collapse of the merger remnant into a black hole. Radiation from accretion processes on the compact-object remnant represents a viable alternative. Neither a kilonova afterglow nor accretion-powered emission have been observed before, as detections of BNS mergers at this phase of evolution are unprecedented

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Optimization of selenium in CdZnTeSe quaternary compound for radiation detector applications

X- and gamma-ray detectors are increasingly becoming essential tool for science and technology in various fields include homeland security, nonproliferation, nuclear security, medical imaging, astrophysics, and high energy physics. Cd 1-x Zn x Te 1-y Se y (CZTS) is emerging as a next-generation compound semiconductor for such applications. CZTS was found to possesses a very low concentration of Te inclusions and free from sub-grain boundary networks. Being a quaternary compound with varying alloy composition, optimization of the composition was performed to determine the minimum amount of selenium required to produce CZTS with reduced defects. The optimized composition was found to be x=0.10 and y=0.02, i.e., Cd 0.9 Zn0.1Te 0.98 Se 0.02 , for excellent material properties as a radiation detector. The resulting material was free from sub-grain boundary networks and with a highly reduced concentration of Te inclusions. The bulk dark resistivity obtained was in the range of 1-3x1010 ohm-cm with the highest achieved mobility-lifetime product of ~6.6x10-3 cm2/V for the optimized CZTS composition. Impurity analyses were performed by the Glow Discharge Mass Spectroscopy (GDMS) technique, and the results showed relatively high impurity concentrations compared to commercial detector-grade CdZnTe. Thus, CZTS has room for further improvement with additional purification of the starting materials.

36 MATERIALS SCIENCE↗

Case Study of High-Throughput Drug Screening and Remote Data Collection for SARS-CoV-2 Main Protease by Using Serial Femtosecond X-ray Crystallography

Since early 2020, COVID-19 has grown to affect the lives of billions globally. A worldwide investigation has been ongoing for characterizing the virus and also for finding an effective drug and developing vaccines. As time has been of the essence, a crucial part of this research has been drug repurposing; therefore, confirmation of in silico drug screening studies have been carried out for this purpose. Here we demonstrated the possibility of screening a variety of drugs efficiently by leveraging a high data collection rate of 120 images/second with the new low-noise, high dynamic range ePix10k2M Pixel Array Detector installed at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Linac Coherent Light Source (LCLS). The X-ray Free-Electron Laser (XFEL) is used for remote high-throughput data collection for drug repurposing of the main protease (Mpro) of SARS-CoV-2 at ambient temperature with mitigated X-ray radiation damage. We obtained multiple structures soaked with nine drug candidate molecules in two crystal forms. Although our drug binding attempts failed, we successfully established a high-throughput Serial Femtosecond X-ray crystallographic (SFX) data collection protocol.

60 APPLIED LIFE SCIENCES↗

Beating absorption in solid-state high harmonics

Since the new millennium coherent extreme ultra-violet and soft x-ray radiation has revolutionized the understanding of dynamical physical, chemical and biological systems at the electron’s natural timescale. Unfortunately, coherent laser-based upconversion of infrared photons to vacuum-ultraviolet and soft x-ray high-order harmonics in gaseous, liquid and solid targets is notoriously inefficient. In dense nonlinear media, the limiting factor is strong re-absorption of the generated high-energy photons. Here we overcome this limitation by generating high-order harmonics from a periodic array of thin one-dimensional crystalline silicon ridge waveguides. Adding vacuum gaps between the ridges avoids the high absorption loss of the bulk and results in a ~ 100-fold increase of the extraction depth. As the grating period is varied, each high harmonic shows a different and marked modulation, indicating their waveguiding in the vacuum slots with reduced absorption. Looking ahead, our results enable bright on-chip coherent short-wavelength sources and may extend the usable spectral range of traditional nonlinear crystals to their absorption windows. Potential applications include on-chip chemically-sensitive spectro-nanoscopy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation furnace for synchrotron dark-field x-ray microscopy experiments

We present a multi-purpose radiation furnace designed for x-ray experiments at synchrotrons. The furnace is optimized specifically for dark-field x-ray microscopy (DFXM) of crystalline materials at beamline ID06 of the European Synchrotron Radiation Facility. The furnace can reach temperatures above 1200 °C with a thermal stability better than 10 °C, with heating and cooling rates up to 30 K/s. The non-contact heating design enables samples to be heated either in air or in a controlled atmosphere contained within a capillary tube. The temperature was calibrated via the thermal expansion of an α-iron grain. Temperature profiles in the y and z axes were measured by scanning a thermocouple through the focal spot of the radiation furnace. In the current configuration of the beamline, this furnace can be used for DFXM, near-field x-ray topography, bright-field x-ray nanotomography, high-resolution reciprocal space mapping, and limited powder diffraction experiments. As a first application, we present a DFXM case study on isothermal heating of a commercially pure single crystal of aluminum.

Yildirim, C. (ORCID:0000000249690685)↗

Plasma radiation behavior approaching high-radiation scenarios in W7-X

The W7-X stellarator has so far performed experiments under both limiter and divertor conditions. The plasma is mostly generated by ECR-heating with powers up to 6.5 MW, and the plasma density is usually limited by the radiation losses from low-Z impurities (such as carbon and oxygen) released mainly from the graphite targets. The present work first summarizes the radiation loss fractions f rad achieved in quasi-stationary hydrogen plasmas in both operational phases, and then shows how impurity radiation behaves differently with the two different boundary conditions as the plasma density increases. The divertor operation is emphasized and some beneficial effects (with respect to impurity radiation) are highlighted: (1) intensive radiation is located at the edge (r/a > 0.8) even at high radiation loss fractions, (2) the plasma remains stable up to f rad approaching unity, (3) the reduction in the stored energy is about 10% for high f rad scenarios. Moreover, effects of wall boronisation on impurity radiation profiles are also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Voltage Potassium Hexacyanoferrate Cathode via High-Entropy and Potassium Incorporation for Stable Sodium-Ion Batteries

Prussian blue analogues (PBAs) used as sodium ion battery (SIB) cathodes are usually the focus of attention due to their three-dimensional open frame and high theoretical capacity. Nonetheless, the disadvantages of a low working voltage and inferior structural stability of PBAs prevent their further applications. Herein, we propose constructing the K x (MnFeCoNiCu)[Fe(CN) 6 ] (HE-K-PBA) cathode by high-entropy and potassium incorporation strategy to simultaneously realize high working voltage and cycling stability. In this study, the reaction mechanism of metal cations in HE-K-PBA are revealed by synchrotron radiation X-ray absorption spectroscopy (XAS), ex situ X-ray photoelectron spectroscopy (XPS), and in situ Raman spectra. We also investigate the entropy stabilization mechanism via finite element simulation, demonstrating that HE-K-PBA with small von Mises stress and weak structure strain can significantly mitigate the structural distortion. Benefit from the stable structure and everlasting K + (de)intercalation, the HE-K-PBA delivers high output voltage (3.46 V), good reversible capacity (120.5 mAh g –1 at 0.01 A g –1 ), and capacity retention of 90.4% after 1700 cycles at 1.0 A g –1 . Moreover, the assembled full cell and all-solid-state batteries with a stable median voltage of 3.29 V over 3000 cycles further demonstrate the application prospects of the HE-K-PBA cathode.

25 ENERGY STORAGE↗

A hybrid-kinetic simulation tool for non-thermal warm x-ray z-pinch sources, with gas-puff and wire array exemplars

Increasing the fluence of z-pinch x-ray radiation sources above ∼ 10 keV has been a long-standing goal for scientists at Sandia National Laboratories’ Z Machine. Optimizing sources for non-thermal “cold Kα” emission in higher atomic-number materials appears to be a promising path to increase warm x-ray yield. However, this emission is generated by supra-thermal electrons, which are not treated in the magnetohydrodynamic (MHD) codes that are typically used in z-pinch source development. MHD codes do not allow for charge separation or space-charge-generated electric fields, and constrain particle kinematics to Maxwellian distributions. The kinetic codes which do accommodate discrete, non-thermal energy distributions are computationally prohibitive when modeling plasmas near solid density and when modeling/tracking higher ionization states. Thus, modeling non-thermal z-pinch sources requires a new simulation tool. In this report, we present a new hybrid modeling capability that uses the fast features of MHD-type particles to the greatest extent possible, then transitions to the slower but more complete kinetic particle treatment to correctly capture the particle energy spectra that generate non-thermal emission. This capability is founded on the fully-relativistic particle-in-cell code Chicago, which already includes fluid particle treatments. The governing equations and hybrid methodology presented here are applied in simulations of an argon gas-puff and a molybdenum wire-array to provide preliminary code validation. The argon simulation is compared to measured implosion times and yields from Jones et al., Phys. Plasmas 22, 020706 (2015). The simulated x-ray yield is within 25% of measurements and the implosion times agree within a few percent. The molybdenum wire array simulation captures the implosion timing reported in Hansen et al., Phys. Plasmas 21, 031202 (2014), but work is needed to verify the available EOS table. These exemplar simulations represents the type of non-thermal sources that will be developed using the hybrid code capability going forward.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Outflowing photoionized plasma in Circinus X-1 using the high-resolution X-ray spectrometer Resolve onboard XRISM and the radiative transfer code cloudy

High-resolution X-ray spectroscopy is a key to understanding the mass inflow and outflow of compact objects. Spectral lines carry information about the ionization, density, and velocity structures through their intensity ratios and profiles. They are formed in non-local thermodynamic equilibrium conditions under the intense radiation field from the compact objects; thus radiative transfer (RT) calculation is a requisite for proper interpretations. We present such a study for a low-mass X-ray binary, Circinus X-1, from which the P Cygni profile was discovered using the X-ray grating spectrometer onboard Chandra. We observed the source using the X-ray microcalorimeter onboard XRISM at an orbital phase of 0.93–0.97 and revealed many spectral features unidentified before: the higher series transitions ($n{\rightarrow }1$; $n>2$) of highly ionized (H- and He-like) S, Ca, Ar, and Fe in emission and absorption, the Fe K$\alpha$ and K$\beta$ inner-shell excitation absorption of mildly ionized (O- to Li-like) Fe, and resolved fine-structure level transitions in the Fe Ly$\alpha$ and He$\alpha$ complexes. They blend with each other at different velocity shifts on top of apparently variable continuum emission that changed its flux by an order of magnitude within a 70 ks telescope time. Despite such complexity in the observed spectra, most of them can be explained by a simple model consisting of the photoionized plasma outflowing at $\sim$300 km s$^{-1}$ and the variable blocking material in the line of sight of the incident continuum emission from the accretion disk. We demonstrate this with the aid of the RT code cloudy for the line ratio diagnostics and spectral fitting. We further constrain the physical parameters of the outflow and argue that the outflow is launched close to the outer edge of the accretion disk and can be driven radiatively by being assisted by the line force calculated using the RT simulation.

X-rays: binaries↗

Platform for probing radiation transport properties of hydrogen at conditions found in the deep interiors of red dwarfs

We describe an experimental concept at the National Ignition Facility for specifically tailored spherical implosions to compress hydrogen to extreme densities (up to ∼800× solid density, electron number density ne∼4×1025 cm−3) at moderate temperatures (T∼200 eV), i.e., to conditions, which are relevant to the interiors of red dwarf stars. The dense plasma will be probed by laser-generated x-ray radiation of different photon energy to determine the plasma opacity due to collisional (free–free) absorption and Thomson scattering. The obtained results will benchmark radiation transport models, which in the case for free–free absorption show strong deviations at conditions relevant to red dwarfs. This very first experimental test of free–free opacity models at these extreme states will help to constrain where inside those celestial objects energy transport is dominated by radiation or convection. Moreover, our study will inform models for other important processes in dense plasmas, which are based on electron–ion collisions, e.g., stopping of swift ions or electron–ion temperature relaxation.