Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X CODES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advanced x-ray imaging spectrometer

An x-ray spectrometer that also provides images of an x-ray source. Coded aperture imaging techniques are used to provide high resolution images. Imaging position-sensitive x-ray sensors with good energy resolution are utilized to provide excellent spectroscopic performance. The system produces high resolution spectral images of the x-ray source which can be viewed in any one of a number of specific energy bands.

Callas, John L.↗

Imaging Analysis of the Hard X-Ray Telescope ProtoEXIST2 and New Techniques for High-Resolution Coded-Aperture Telescopes

Wide-field (greater than or approximately equal to 100 degrees squared) hard X-ray coded-aperture telescopes with high angular resolution (greater than or approximately equal to 2 minutes) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

balloons - instrumentation: detectors - techniques↗

Research on effect of emission uniformity on X-band relativistic backward oscillator using conformal PIC code

Explosive emission cathodes (EECs) are adopted in relativistic backward wave oscillators (RBWOs) to generate intense relativistic electron beam. The emission uniformity of the EEC can render saturation of the power generation unstable and the output mode impure. However, the direct measurement of the plasma parameters on the cathode surface is quite difficult and there are very few related numerical study reports about this issue. In this paper, a self-developed three-dimensional conformal fully electromagnetic particle in cell code is used to study the effect of emission uniformity on the X-band RBWO; the electron explosive emission model and the field emission model are both implemented in the same cathode surface, and the local field enhancement factor is also considered in the field emission model. The RBWO with a random nonuniform EEC is thoroughly studied using this code; the simulation results reveal that when the area ratio of cathode surface for electron explosive emission is 80%, the output power is unstable and the output mode is impure. When the annular EEC does not emit electron in the angle range of 30°, the RBWO can also operate normally.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Poster - 28: Shielding of X-ray Rooms in Ontario in the Absence of Best Practice

This poster will be strictly based on the Healing Arts Radiation Protection (HARP) Act, Regulation 543 under this Act (X-ray Safety Code), and personal communication the presenting author has had. In Ontario, the process of approval of an X-ray machine installation by the Director of the X-ray Inspection Service (XRIS) follows a certain protocol. Initially, the applicant submits a series of forms, including recommended shielding amounts, in order to satisfy the law. This documentation is then transferred to a third-party vendor (i.e. a professional engineer – P.Eng.) outsourced by the Ministry of Health and Long-term Care (MOHLTC). The P.Eng. then evaluates the submitted documentation for appropriate fulfillment of the HARP Act and Reg. 543 requirements. If the P.Eng.’s evaluation of the documentation is to their satisfaction, the XRIS is then notified. Finally, the Director will then issue a letter of approval to install the equipment at the facility. The methodology required to be used by the P.Eng. in order to determine the required amounts of protective barriers, and recommended to be used by the applicant, is contained within Safety Code 20A. However, Safety Code 35 has replaced the obsolete Safety Code 20A document and employs best practices in shielding design. This talk will focus further on specific intentions and limitations of Safety Code 20A. Furthermore, this talk will discuss the definition of the “practice of professional engineering” in Ontario. COMP members who are involved in shielding design are strongly encouraged to attend.

60 APPLIED LIFE SCIENCES↗

Codes for sub-resolution modeling of the apparent mass loss in quantitative broadband X-ray radiography

SAND2022-3463 O This code is intended to accompany the journal manuscript, “Sub-resolution modeling of the apparent mass loss in quantitative broadband X-ray radiography." The manuscript covers in detail how to improve the quantitative mass distribution measurements made for optical diagnostics of multiphase flows. The code contains four separate script files in MATLAB format to support the objective of improving mass measurements. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rahman, Naveed↗

X-33 Aerodynamic and Aeroheating Computations for Wind Tunnel and Flight Conditions

This report provides an overview of hypersonic Computational Fluid Dynamics research conducted at the NASA Langley Research Center to support the Phase II development of the X-33 vehicle. The X-33, which is being developed by Lockheed-Martin in partnership with NASA, is an experimental Single-Stage-to-Orbit demonstrator that is intended to validate critical technologies for a full-scale Reusable Launch Vehicle. As part of the development of the X-33, CFD codes have been used to predict the aerodynamic and aeroheating characteristics of the vehicle. Laminar and turbulent predictions were generated for the X 33 vehicle using two finite- volume, Navier-Stokes solvers. Inviscid solutions were also generated with an Euler code. Computations were performed for Mach numbers of 4.0 to 10.0 at angles-of-attack from 10 deg to 48 deg with body flap deflections of 0, 10 and 20 deg. Comparisons between predictions and wind tunnel aerodynamic and aeroheating data are presented in this paper. Aeroheating and aerodynamic predictions for flight conditions are also presented.

Hollis, Brian R.↗

Highly Extensible X-ray Diffraction Toolkit

This code has been previous released as open source under LLNL-CODE-529294. The HEXRD program comprises a library of X-ray diffraction analysis tools and a stand-alone GUI application. While there are many software packages that provide similar capabilities, HEXRD was designed to provide an extremely flexible and extensible basis for describing a broad array of X-ray diffraction instruments; this includes both mono- and poly-chromatic modalities as well as poly- and single-crystal samples. The high-level objects include Material: an abstraction for defining crystalline materials, including unit cell parameters and anisotropic elastic moduli Imageseries: an interface for series of diffraction images containing one or more frames, including provisions for metadata. Instrument: an abstraction of an X-ray diffraction instrument including support for the definition of multiple detector elements as well as powder, Laue, and mono-chromatic single/multi-grain diffraction analysis modalities (including attendant calibration routines). The hexrdgui package is a standalone PySide2/Qt5 GUI built on top of hexrd. The 0.8.1 release includes various bug fixes as well as some new functionality in the GUI, including: o Enhancements to the import tools for LLNL diffraction instruemtns (PXRDIP and TARDIS) o The ability to save 1-d LeBail fits of integrated diffraction spectra.

Barton, NathanR.↗

More box codes

A new investigation shows that, starting from the BCH (21,15;3) code represented as a 7 x 3 matrix and adding a row and column to add even parity, one obtains an 8 x 4 matrix (32,15;8) code. An additional dimension is obtained by specifying odd parity on the rows and even parity on the columns, i.e., adjoining to the 8 x 4 matrix, the matrix, which is zero except for the fourth column (of all ones). Furthermore, any seven rows and three columns will form the BCH (21,15;3) code. This box code has the same weight structure as the quadratic residue and BCH codes of the same dimensions. Whether there exists an algebraic isomorphism to either code is as yet unknown.

Solomon, G.↗

Quantitative measurement of hard x-ray spectra for high intensity laser produced plasma

X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-uniform Neutron Source Approximation for Iterative Reconstruction of Coded Source Images

X-ray and neutron optics both lack ray focusing capabilities. An x-ray source can be made small and powerful enough to facilitate high-resolution imaging while providing adequate flux. This is not yet possible for neutrons. One remedy is to employ a computational imaging technique such as magnified coded source imaging. The greatest challenge associated with successful reconstruction of high-resolution images from such radiographs is to precisely model the flux distribution for complex non-uniform neutron sources. We have developed a framework based on Monte Carlo simulation and iterative reconstruction that facilitates high- resolution coded source neutron imaging. In this paper, we define a methodology to empirically measure and approximate the flux profile of a non-uniform neutron source, and we show how to incorporate the result within the forward model of an iterative reconstruction algorithm. We assess improvement in image quality by comparing reconstructions based respectively on the new empirical forward model and our previous analytic models.

Gregor, Jens↗

Lagrangian particle model for 3D simulation of pellets and SPI fragments in tokamaks

A 3D numerical model for the ablation of pellets and shattered pellet injection (SPI) fragments in tokamaks in the plasma disruption mitigation and fueling parameter space has been developed based on the Lagrangian particle code [R. Samulyak, X. Wang, H.-S. Chen, Lagrangian Particle Method for Compressible Fluid Dynamics, J. Comput. Phys., 362 (2018), 1-19]. The pellet code implements the low magnetic Reynolds number MHD equations, kinetic models for the electronic heating, a pellet surface ablation model, an equation of state that supports multiple ionization states, radiation, and a model for grad-B drift of the ablated material across the magnetic field. The Lagrangian particle algorithm is highly adaptive, capable of simulating a large number of fragments in 3D while eliminating numerical difficulties of dealing with the tokamak background plasma. The code has achieved good agreement with theory for spherically symmetric ablation flows. Axisymmetric simulations of neon and deuterium pellets in magnetic fields ranging from 1 to 6 Tesla have been compared with previous simulations using the FronTier code, and very good agreement has also been obtained. Furthermore, the main physics contribution of the paper is a detailed study of the influence of 3D effects, in particular grad-B drift, on pellet ablation rates and properties of ablation clouds. Smaller reductions of ablation rates in magnetic fields compared to axially symmetric simulations have been demonstrated because the ablated material is not confined to narrowing channels in the presence of grad-B drift. Contribution of various factors in the grad-B drift model has also been quantified.

97 MATHEMATICS AND COMPUTING↗

Block encoders for Reed-Muller codes

Encoding algorithms generate a 32 x 64-bit matrix Reed-Muller code from a 6-bit orthogonal code-word. This increases error-free reception by a high rate telemetry channel under adverse signal noise with minimal use of additional hardware.

Anderson, T. O.↗

Optical Design in Phase-Space for the I13L X-Ray Imaging and Coherence Beamline at Diamond using XPHASY

I13L is a 250 m long beamline for imaging and coherent diffraction currently under construction at the Diamond Light Source. For modeling the beamline optics the phase-space based ray-tracing code XPHASY was developed, as general ray-tracing codes for x-rays do not easily allow studying the propagation of coherence along the beamline. In contrast to computational intensive wave-front propagation codes, which fully describe the propagation of a photon-beam along a beamline but obscure the impact of individual optical components onto the beamline performance, this code allows to quickly calculate the photon-beam propagation along the beamline and estimate the impact of individual components.In this paper we will discuss the optical design of the I13L coherence branch from the perspective of phase-space by using XPHASY. We will demonstrate how the phase-space representation of a photon-beam allows estimating the coherence length at any given position along the beamline. The impact of optical components on the coherence length and the effect of vibrations on the beamline performance will be discussed. The paper will demonstrate how the phase-space representation of photon-beams allows a more detailed insight into the optical performance of a coherence beamline than ray-tracing in real space.

43 PARTICLE ACCELERATORS↗

High-resolution imaging gamma-ray spectroscopy with externally segmented germanium detectors

Externally segmented germanium detectors promise a breakthrough in gamma-ray imaging capabilities while retaining the superb energy resolution of germanium spectrometers. An angular resolution of 0.2 deg becomes practical by combining position-sensitive germanium detectors having a segment thickness of a few millimeters with a one-dimensional coded aperture located about a meter from the detectors. Correspondingly higher angular resolutions are possible with larger separations between the detectors and the coded aperture. Two-dimensional images can be obtained by rotating the instrument. Although the basic concept is similar to optical or X-ray coded-aperture imaging techniques, several complicating effects arise because of the penetrating nature of gamma rays. The complications include partial transmission through the coded aperture elements, Compton scattering in the germanium detectors, and high background count rates. Extensive electron-photon Monte Carlo modeling of a realistic detector/coded-aperture/collimator system has been performed. Results show that these complicating effects can be characterized and accounted for with no significant loss in instrument sensitivity.

Callas, J. L.↗

X-Ray, EUV, UV and Optical Emissivities of Astrophysical Plasmas

This grant primarily covered the development of the thermal X-ray emission model code called APEC, which is meant to replace the Raymond and Smith (1977) code. The new code contains far more spectral lines and a great deal of updated atomic data. The code is now available (http://hea-www.harvard.edu/APEC), though new atomic data is still being added, particularly at longer wavelengths. While initial development of the code was funded by this grant, current work is carried on by N. Brickhouse, R. Smith and D. Liedahl under separate funding. Over the last five years, the grant has provided salary support for N. Brickhouse, R. Smith, a summer student (L. McAllister), an SAO predoctoral fellow (A. Vasquez), and visits by T. Kallman, D. Liedahl, P. Ghavamian, J.M. Laming, J. Li, P. Okeke, and M. Martos. In addition to the code development, the grant supported investigations into X-ray and UV spectral diagnostics as applied to shock waves in the ISM, accreting black holes and white dwarfs, and stellar coronae. Many of these efforts are continuing. Closely related work on the shock waves and coronal mass ejections in the solar corona has grown out of the efforts supported by the grant.

Raymond, John C.↗

Verification of local electrostatic gyrokinetic simulation of driftwave instability in field-reversed configuration

Local linear simulations of ion temperature gradient (ITG) instabilities using a gyrokinetic particle code GKD1D have been verified by comparing with the analytic dispersion relation in the slab geometry and by benchmarking with a global gyrokinetic code GTC-X in a realistic field-reversed configuration (FRC). Results of ITG simulations using either adiabatic or kinetic electrons exhibit excellent agreements between the two codes for linear frequencies, growth rates, and mode structures. The ITG modes in the FRC scrape-off layer region are mostly dominated by the poloidal m = 1 harmonic. Kinetic electrons enhance the subdominant m = 2 harmonic and the even parity dominates the ITG mode structure. Kinetic electrons increase the growth rates for the low-n modes, but decrease the growth rates for the high-n modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CTT: Tools for Fine Alignment of Flash X-ray Systems

The CTT code is a compilation of the python code that was prototyped in the interest of making a method for fine alignment of Flash X-ray Systems at the lab. It contains python code for interacting with LTT and running optimization loops using LTT simulations or ray tracing with RaySpace. It Includes classes for creating phantom objects and modular geometry objects in the simulations. It allows one to generate a random phantom that has been optimized to stay with a certain cubic volume and maximize the minimum distance between any two ball phantom centers in all projections. It was primarily made to work on ball phantoms which were simulated as Teflon spheres. It allows the alignment from some nominal position to some displaced position to simulate recovery of a real geometry from the nominal geometry of the system. Fine alignment can be done with the projections in LTT while a rough alignment is faster using rayspace. If rayspace works well for the use case it should be preferred since it is considerably faster and less resource intensive in general. Some Notes about using this code is that one will have to edit the imports for the files to get to the correct LTT path, LTT GUI path and to the CTT path when importing. This was made by using anaconda with python 3 on windows 10. The LTT code was stored in a anaconda environment which seemed to help the python find the LTT although it shouldn’t be necessary if you append the path in your code using sys.path.append(r'add the path you want here’). The sys.path.append method is a quick way to give your python code access to a given folder when running it (such as LTT or CTT). Note that since the code was originally made with paths for a specific machine that a new user will have to edit those paths to make it work in all the files that use the old paths. This is somewhat tedious but will be required to run the code on a new machine. The methodology used to run and make these notebooks starts with opening a command prompt as administrator in windows 10. After this one would activate the anaconda environment in the appropriate directory using “conda activate myenv” in the command prompt. After this open a jupyter-notebook using the keyword “jupyter-notebook". After that a notebook should open in a browser. Note that some libraries used may not come with anaconda so those may have to be installed. There shouldn’t be much though since the main things used are scipy, numpy, matplotlib, and LTT. LTTQuicksetup also requires some paths that will be specific to the computer so that should be changed as well.

42 ENGINEERING↗

Flash-X Recipe Tools

SF-24-102 A code generation tool for Flash-X to support their performance portability using a domain-specific runtime library.

Lee, Youngjun↗