Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “White Light Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

124 records · Page 7

Microstructural and Oxidation Effects of Nb Additions to U3Si2

U3Si2 is a long term, accident-tolerant nuclear fuel candidate for light-water reactors because of its superior thermal conductivity and increased uranium density when compared to traditional uranium dioxide (UO2). While reducing internal thermal stresses and increasing efficiency, U3Si2 exhibits energetic oxidation during certain off-normal and accident scenarios, which include coolant or steam exposure. To mitigate this, Nb is investigated as an alloy constituent to enhance corrosion resistance and increase mechanical strength. The work presented investigates the response of Nb-alloyed U3Si2 to steam atmospheres. A thermogravimetric analysis is conducted in flowing steam to T > 1000 °C to assess oxidation resistance. The phase characterization of as-melted, thermally annealed and post-oxidation compositions with up to 12 vol% Nb by powder X-ray diffraction, scanning electron microscopy, and energy dispersive spectroscopy is reported.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

6 nm super-resolution optical transmission and scattering spectroscopic imaging of carbon nanotubes using a nanometer-scale white light source

Abstract Optical transmission and scattering spectroscopic microscopy at the visible and adjacent wavelengths denote one of the most informative and inclusive characterization methods in material research. Unfortunately, restricted by the diffraction limit of light, it cannot resolve the nanoscale variation in light absorption and scattering, diagnostics of the local inhomogeneity in material structure and properties. Moreover, a large quantity of nanomaterials has anisotropic optical properties that are appealing yet hard to characterize through conventional optical methods. There is an increasing demand to extend the optical hyperspectral imaging into the nanometer length scale. In this work, we report a super-resolution hyperspectral imaging technique that uses a nanoscale white light source generated by superfocusing the light from a tungsten-halogen lamp to simultaneously obtain optical transmission and scattering spectroscopic images. A 6-nm spatial resolution in the visible to near-infrared wavelength regime (415–980 nm) is demonstrated on an individual single-walled carbon nanotube (SW-CNT). Both the longitudinal and transverse optical electronic transitions are measured, and the SW-CNT chiral indices can be identified. The band structure modulation in a SW-CNT through strain engineering is mapped.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of ZnO on the whiteness of white Portland cement clinker

The addition of ZnO to significantly improve the Hunter whiteness of white Portland cement (WPC) clinkers is introduced in this paper. The effects of ZnO on the whiteness of WPC were studied by chroma analysis, X-ray diffraction (XRD), the Rietveld method, hydration heat measurements and SEM-EDS. The results showed that adding ZnO increased the visible light reflectance, increased the brightness (L{sup ⁎}), and reduced the yellowness (b{sup ⁎}) of WPC clinker with high Fe{sub 2}O{sub 3}. Therefore, ZnO can increase the whiteness of WPC clinker. Zn was mainly distributed in the amorphous phase and unquantifiable crystalline phase (ACn), and then dissolved in the silicate phase. ZnO stabilized R-C{sub 3}S, reduced the crystallization of C{sub 3}A, and increased the ACn content. ZnO increased the amount of Fe in the ACn and minerals, thereby reducing the formation of C{sub 4}AF and improving whiteness. ZnO increased the accumulated heat of hydration but prolonged the induction period. This method provides a new approach for the WPC industry to broaden sources of raw materials and improve product quality.

36 MATERIALS SCIENCE↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗

Metallographic Preparation of Space Shuttle Reaction Control System Thruster Electron Beam Welds for Electron Backscatter Diffraction

A Space Shuttle Reaction Control System (RCS) thruster failed during a firing test at the NASA White Sands Test Facility (WSTF), Las Cruces, New Mexico. The firing test was being conducted to investigate a previous electrical malfunction. A number of cracks were found associated with the fuel closure plate/injector assembly (Fig 1). The firing test failure generated a flight constraint to the launch of STS-133. A team comprised of several NASA centers and other research institutes was assembled to investigate and determine the root cause of the failure. The JSC Materials Evaluation Laboratory was asked to compare and characterize the outboard circumferential electron beam (EB) weld between the fuel closure plate (Titanium 6Al-4V) and the injector (Niobium C-103 alloy) of four different RCS thrusters, including the failed RCS thruster. Several metallographic challenges in grinding/polishing, and particularly in etching were encountered because of the differences in hardness, ductility, and chemical resistance between the two alloys and the bimetallic weld. Segments from each thruster were sectioned from the outboard weld. The segments were hot-compression mounted using a conductive, carbon-filled epoxy. A grinding/polishing procedure for titanium alloys was used [1]. This procedure worked well on the titanium; but a thin, disturbed layer was visible on the niobium surface by means of polarized light. Once polished, each sample was micrographed using bright field, differential interference contrast optical microscopy, and scanning electron microscopy (SEM) using a backscatter electron (BSE) detector. No typical weld anomalies were observed in any of the cross sections. However, areas of large atomic contrast were clearly visible in the weld nugget, particularly along fusion line interfaces between the titanium and the niobium. This prompted the need to better understand the chemistry and microstructure of the weld (Fig 2). Energy Dispersive X-Ray Spectroscopy (EDS) was used to confirm the chemical composition of the variations in contrast in these areas. Niobium alloys generally require exposure to more aggressive chemical reagents than titanium alloys for etching because of niobium s chemical resistance; therefore, the titanium portion of the sample was etched first. A five second immersion in Kroll s reagent revealed a general microstructure on the titanium portion of the sample; however, the titanium heat affected zone closest to the weld, was over-etched due to higher concentrations of refined grains and an increase in eta-phase. The Kroll s etchant also revealed some microstructure in the weld nugget itself; the niobium portion of the sample remained unetched.

Martinez, James↗

Hydrothermal synthesis and luminescent properties of NaLa(MoO{sub 4}){sub 2}:Dy{sup 3+} phosphor

Pompon-like NaLa(MoO{sub 4}){sub 2}:Dy{sup 3+} phosphors have been successfully prepared via a hydrothermal method using ammonia as pH value regulator. The hydrothermal process was carried out under aqueous condition without the use of any organic solvent, surfactant, and catalyst. The experimental results demonstrate that the obtained NaLa(MoO{sub 4}){sub 2}:Dy{sup 3+} phosphor powders are single-phase scheelite structure with tetragonal symmetry. Moreover, the phosphor under the excitation of 390 and 456 nm exhibited blue emission (486 nm) and yellow emission (574 nm), corresponding to the {sup 4}F{sub 9/2}{yields}{sup 6}H{sub 15/2} transition and {sup 4}F{sub 9/2}{yields}{sup 6}H{sub 13/2} transition of Dy{sup 3+} ions, respectively. In addition, the yellow-to-blue emission intensity ratio (Y/B) can be changed with the doped concentration of Dy{sup 3+} ions. All chromaticity coordinates of the obtained NaLa(MoO{sub 4}){sub 2}:Dy{sup 3+} phosphors are located in the white-light region. The results indicate that this kind of phosphor may has potential applications in the fields of near UV-excited and blue-excited white LEDs. - Graphical abstract: It can be seen from the SEM images that a pompon-like shape was obtained with an average diameter of about 1 {mu}m, and it is composed of many nanoflakes. Highlights: Black-Right-Pointing-Pointer Pompon-like NaLa(MoO{sub 4}){sub 2}:Dy{sup 3+} phosphors have been successfully prepared via a hydrothermal method. Black-Right-Pointing-Pointer Blue emission at 486 nm and yellow emission at 574 nm were obtained from the samples. Black-Right-Pointing-Pointer The yellow-to-blue emission intensity ratio (Y/B) can be changed with the doped concentration of Dy{sup 3+} ions. Black-Right-Pointing-Pointer NaLa(MoO{sub 4}){sub 2}:Dy{sup 3+} can be efficiently excited by the blue light and the near ultraviolet light.

36 MATERIALS SCIENCE↗

Energy dispersive detector for white beam synchrotron x-ray fluorescence imaging

A novel, “single-shot” fluorescence imaging technique has been demonstrated on the B16 beamline at the Diamond Light Source synchrotron using the HEXITEC energy dispersive imaging detector. A custom made furnace with 200µm thick metal alloy samples was positioned in a white X-ray beam with a hole made in the furnace walls to allow the transmitted beam to be imaged with a conventional X-ray imaging camera consisting of a 500 µm thick single crystal LYSO scintillator, mirror and lens coupled to an AVT Manta G125B CCD sensor. The samples were positioned 45° to the incident beam to enable simultaneous transmission and fluorescence imaging. The HEXITEC detector was positioned at 90° to the sample with a 50 µm pinhole 13 cm from the sample and the detector positioned 2.3m from pinhole. The geometric magnification provided a field of view of 1.1×1.1mm{sup 2} with one of the 80×80 pixels imaging an area equivalent to 13µm{sup 2}. Al-Cu alloys doped with Zr, Ag and Mo were imaged in transmission and fluorescence mode. The fluorescence images showed that the dopant metals could be simultaneously imaged with sufficient counts on all 80x80 pixels within 60 s, with the X-ray flux limiting the fluorescence imaging rate. This technique demonstrated that it is possible to simultaneously image and identify multiple elements on a spatial resolution scale ~10µm or higher without the time consuming need to scan monochromatic energies or raster scan a focused beam of X-rays. Moving to high flux beamlines and using an array of detectors could improve the imaging speed of the technique with element specific imaging estimated to be on a 1 s timescale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructures of chemical vapor deposited high-purity tungsten achieved by two different precursors

Highlights: • CVD tungsten used as electron emitters of thermionic fuel elements was investigated. • Microstructures were characterized with metallography analysis. • The preferred orientation was determined with XRD and EBSD. • The surface morphology was observed with SEM and WLI. • Tungsten via thermolysis of WCl{sub 6} is better for thermionic fuel elements. - Abstract: Chemical vapor deposited (CVD) high-purity tungsten can be manufactured as electron emitters in thermionic fuel elements. Exposed surface planes of the emitter emit electrons and affect the efficiency and load capacity of the thermionic fuel element. In order to determine the electron emission planes of the emitter, the metallurgic structures, the preferred orientation and the as-deposited surface morphology of CVD tungsten have been investigated. In this work, high-purity (over 99.99%) tungsten was achieved by two different precursors: hydrogen reduction of tungsten hexafluoride (WF{sub 6}) and thermolysis of tungsten hexachloride (WCl{sub 6}). The microstructures of CVD tungsten were characterized by metallography analysis, X-ray diffraction (XRD), electron backscattered diffraction (EBSD), and white light interference (WLI). Tungsten fabricated by hydrogen reduction of WF{sub 6} and thermolysis of WCl{sub 6} has <100>-preferred columnar microstructures. However, the latter exhibits larger columnar grains and preferred <100> less. The preferred orientation is caused by the higher growth rate of the <100> orientation and competition between the <100> orientations of different grains. The as-deposited surface consists of tiny pyramids, with <100> axis and {111} side faces. In contrast to tungsten produced by hydrogen reduction of WF{sub 6}, the pyramid on tungsten synthesized via thermolysis of WCl{sub 6} contains small {110} facets on the four edges. Therefore, tungsten made via thermolysis of WCl{sub 6} is a better candidate for thermionic fuel elements, because the higher work function of {110} planes enables better output efficiency.

36 MATERIALS SCIENCE↗

Compatibility Of U 3 Si 2 Fuel With Zr, FeCrAl and SiC/SiC Based Cladding

U 3 Si 2 fuel with FeCrAl or SiC/SiC composite cladding is being considered as an advanced concept and accident tolerant fuel (ATF) system for light water reactors. Understanding their chemical compatibility under operational and accident conditions is fundamental to predicting behavior and fuel qualification. In the present work, experimental determination of interactions and thermodynamic and first principle calculation methods were employed to assess U 3 Si 2 compatibility with novel cladding of FeCrAl-alloys and SiC composites, and were contrasted with compatibility with Zircaloy-4. Diffusion-couple experiments were performed to simulate fuelcladding conditions and the samples were subjected to characterization by scanning electron microscopy and x-ray diffraction. Thermodynamic calculations, based in part on newly determined thermodynamic properties, were used to predict the equilibrium state of the studied systems and to interpret experimental results. First principles calculations using density functional theory were employed to obtain incorporation energies for carbon, iron and uranium in U 3 Si 2 , α- Fe, and SiC structures. Together, the experimental and modeling results have allowed evaluation of the nature of interactions in the fuel-cladding systems.

36 MATERIALS SCIENCE↗

Measurements of striae in CR+ doped YAG laser crystals

Striations in Czochralski (CZ) grown crystals have been observed in materials such as GaAs, silicon, photorefractive crystals used for data storage, potassium titanyl phosphate crystals and LiNbO3. Several techniques have been used for investigating these defects including electron microscopy, laser scanning tomography, selective photoetching, X-ray diffuse scattering, interference orthoscopy, laser interferometry and micro-Fourier transform infrared spectroscopy mapping. A 2mm thick sample of the material to be investigated is illuminated with light that is absorbed and non-absorbed by the ion concentration to be observed. The back surface of the sample is focused onto a solid-state image detector and images of the input beam and absorbed (and diffracted) beams are captured at two wavelengths. The variation of the coefficient of absorption asa function of distance on the sample can be derived from these measurements. A Big Sky Software Beamcode system is used to capture and display images. Software has been written to convert the Beamcode data files to a format that can be imported into a spreadsheet program such as Quatro Pro. The spreadsheet is then used to manipulate and display data. A model of the intensity map of the striae collected by the imaging system has been proposed and a data analysis procedure derived. From this, the variability of the attenuation coefficient alpha can be generated. Preliminary results show that alpha may vary by a factor of four or five over distances of 100 mu m. Potential errors and problems have been discovered and additional experiments and improvements to the experimental setup are in progress and we must now show that the measurement techniques and data analysis procedures provide 'real' information. Striae are clearly visible at all wavelengths including white light. Their basic spatial frequency does not change radically, at least when changing from blue to green to white light. Further experimental and theoretical work can be done to improve the data collection techniques and to verify the data analysis procedures.

Cady, Fredrick M.↗

Optical Properties of Ga{sub 2}O{sub 3} Nanostructures

Gallium oxide nanodots of 220-300 nm diameters have been grown by SiO{sub 2}-assisted thermal evaporation. The grayish-white crust deposited on the crucible walls was proved to be crystalline Ga{sub 2}O{sub 3} through X-ray diffraction and TEM electron diffraction. The morphology of the samples examined by SEM confirmed the nanodot structure formation of average diameter 220{+-}30 nm and average density 1.77x108 cm{sup -2}. The absorption spectra of the Ga{sub 2}O{sub 3} suspension in water revealed two absorption peaks at 329.99 nm (3.76 eV) and 338.60 nm (3.67 eV). Photoemission of blue light at room temperature was observed at 410.3 nm under excitation at 330.00{+-}4.06 nm. The growth mechanism of the nanodots is explained by a liquid-vapor-solid mechanism. The measured remaining ingot hardness was found to be 16.6 Vickers hardness number, exceeding that of SiO{sub 2}. This might well indicate the existence of a certain percentage of the hardening Ga{sub 2}O{sub 3} compound in the remaining catalytic ingot.

36 MATERIALS SCIENCE↗

The Multi Optical Transition Radiation System

The determination and monitoring of the transverse phase space in ATF2 is crucial in order to meet their performances specifications. Since the beam sizes at the Interaction Point (IP) depend strongly on the aberrations in the Final Focus System (FFS), accurate measurement upstream of the FFS is required to tune the beam sizes at the IP. The beam sizes as well as the emittance are measured in several locations in the beam diagnostic section of the Extraction Line (EXT line) of ATF2. The vertical beam sizes in the diagnostic section are of the order of 10 {mu}m this means that the devices have to image spot sizes as small as 5 {mu}m, with 10% accuracy a 2 {mu}m resolution device is necessary. The ATF2 EXT line is a beam line with low power and low repetition rate that make usable devices using solid targets. In contrast to a ring machine, where an individual bunch can be measured many times as it passes around the ring, the beam size and the emittance measurement in the LC or in the beam lines have to be performed in a single pass. This requires that the wire scan device types (laser or solid) sample across successive bunches within a train, often with an over-estimation of the beam size due to beam position and intensity jitter, and can take up to half a minute to complete the measurement. Although some of these effects could be corrected, as the jitter effect could be subtracted by using the nearby BPMs signals, this can be avoided by using Optical Transition Radiation (OTR) Monitors. These monitors are based on the transition radiation effect, a light cone emitted when the charged particle crosses a metallic interface. This light is emitted in a specular fashion so it can be focused on to a CCD and produces an image of the beam. OTRs are able to take many fast measurements and therefore to measure the emittance with high statistics, giving a low error and a good understanding of the emittance jitter. In this article, simulations of the expected beam sizes and emittance, along with a technical description of the system, its hardware and software implementation are described. Additionally first measurement of the beam size and emittance of the Multi Optical Transition Radiation System located in the Extraction Line of ATF2 are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TOPOS: A new topometric patient positioning and tracking system for radiation therapy based on structured white light

Purpose: A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. Methods: Two optical sensors are the main parts of the TOPOS Registered-Sign system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 Multiplication-Sign 488 pixels). The projector has a resolution of 1024 Multiplication-Sign 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. Results: Two prototypes have been developed, each allowing a continuous high density scan of a 500 Multiplication-Sign 500 Multiplication-Sign 400 mm{sup 3} (L Multiplication-Sign W Multiplication-Sign D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 {+-} 0.4, -0.2 {+-} 0.7, and -0.1 {+-} 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 {+-} 0.5, -0.6 {+-} 1.9, 0.0 {+-} 0.4 mm. Conclusions: The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

State of knowledge and challenges of U-Si compounds for use in light water reactor accident tolerant fuel designs

Characterization of the properties of U-Si compounds first required synthesis of high purity material for each of the compositions. The four compounds targeted for investigation in this work were U{sub 3}Si, U{sub 3}Si{sub 2}, USi, and U{sub 3}Si{sub 5}. Specimens of U{sub 3}Si{sub 2}, U{sub 3}Si{sub 5}, and USi with specific geometries for individual testing procedures were prepared using a powder metallurgical method. Thermophysical properties of the U-Si compounds were determined within 100 K of their respective melt point or decomposition temperature. Thermal expansion was determined with a dilatometer, specific heat capacity by the ratio method in a differential scanning calorimeter using a sapphire standard, while thermal diffusivity was determined with a laser flash analyzer. Oxidation performance of the U-Si compounds was determined in a thermogravimetric analyzer (TGA), which measures the weight change of a sample as a function of gas composition and temperature. The results show that each of the U-Si compounds is electronically conductive leading to higher thermal conductivity values than the reference fuel UO{sub 2}. Higher thermal conductivity values will lead to enhanced safety margins within a reactor core and provide better economics over the lifetime of a fuel cycle. However, no improvements have been realized over the reference UO{sub 2} case with regards to oxidation performance in air although more testing is required to substantiate the differences especially in steam and corrosive aqueous LWR environments. Finally, there exists a lack of knowledge in the literature with regards to low burnup irradiation testing on all of the U-Si binary compounds, which would be necessary to simulate their performance in a reactor setting.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Si on microstructure and phase transformation at elevated temperatures in ferritic white cast irons

The effects of Si on microstructure and phase transformation at elevated temperature of ferritic 31wt.%Cr-1.1wt.%C white cast irons with up to 3wt.%Si have been studied. Applications of these irons include parts requiring heat resistance at elevated temperature. The irons were produced by sand casting. The microstructure in as-cast condition and after being subjected to high temperature (700 to 1000 °C) was investigated by light microscopy, X-ray diffraction, and electron microscopy. The results revealed that the as-cast microstructure consisted mainly of primary ferrite dendrites and eutectic (ferrite + M{sub 7}C{sub 3}). Si promotes M{sub 7}C{sub 3}-to-M{sub 23}C{sub 6} transformation in the irons subjected to transformation at elevated temperature, but no sigma phase was found. The extent of M{sub 7}C{sub 3}-to-M{sub 23}C{sub 6} transformation increases proportional to the increasing transformation temperature, holding time and Si content in the irons. For the iron with 1.0wt.%Si content after holding at elevated temperatures, martensite was also found, which could be attributed to carbon accretion effects in eutectic ferrite. Si was incorporated in M{sub 23}C{sub 6} such that M{sub 23}C{sub 6} containing Si can show darker contrast under SEM-BEI as compared to M{sub 7}C{sub 3}; this is the opposite to what has been observed for the cases of typical M{sub 23}C{sub 6} and M{sub 23}C{sub 6} containing Mo or W. The results obtained are important to understand the change in properties of ferritic, high chromium irons containing Si subjected to elevated temperature.

36 MATERIALS SCIENCE↗