Fused silica mirror evaluation for the Shuttle Infrared Telescope Facility (SIRTF)

The SIRTF optics are intended for operation at 20 K (or less); it will be extremely inconvenient, expensive, and time consuming if it becomes necessary to accomplish all of the optical element testing, assembly, and alignment at comparable temperatures. The thermal strain behavior, including potential anisotropies and inhomogeneities, of a mirror substrate between room temperature and 20 K thus becomes a major factor in the selection of the substrate material, structural configuration, and joining methods for lightweight structures. With support from Space Projects, NASA Ames Research Center, an optical figure evaluation of a 0.65-meter, lightweight, fused silica mirror at a low-temperature goal of 20 K is being conducted. The design details of a thermal shroud, provisions for extracting heat from the low-conductivity mirror, and wavefront error sources other than the mirror surface are discussed and preliminary test results presented.

Barnes, W. P., Jr.↗

Adaptive optics

An estimation of the costs and potential resolution and sensitivity benefits of adaptive optics systems is presented. The effects of atmospheric disturbances on the peak-to-peak wavefront errors are assessed. Definitions are included of the maximum permissible controlled patch of entrance pupil of the system, the permissible response time, the permissible field radius, and the required magnitude and frequency of a reference star. It is pointed out that adaptive optics system for visible of near-visible wavelengths is likely to be very expensive, whereas operation at 2-3 microns under best seeing conditions is expected to be useful and have reasonable cost.

Woolf, N. J.↗

15 meter multiple mirror telescope design study

Taking as a starting point the existing Multiple Mirror Telescope (MMT), a concept for a larger and more advanced instrument has been developed. It makes use of four 7.5-m diameter paraboloidal glass primaries of the honeycomb sandwich type being developed by the University of Arizona. These are mounted quite close together in a square configuration, with their axes coaligned. Separate optical configurations are provided, for optical and infrared applications. To minimze telescope emissivity in the thermal infrared at the combined focus, all the beam combining and streering optics that follow the tertiary mirrors are enclosed in a large central dewar and cooled with liquid nitrogen. The diffraction-limited resolution at the combined focus of 0.11 arcsec at 10 micrometers wavelength is equivalent to that of a 20.5 meter filled aperture. Diffraction-limited resolution should be routinely achievable at 10 and 20 micrometers, if active correction of large-scale wavefront errors is implemented.

Angel, J. R. P.↗

Coherent phasing of segmented mirrors

The technical issues associated with a coherently phased segmented mirror can be divided into two types. The first involves the issues of manufacturing the surface quality of the mirror segments themselves (coherent phasing of individual segments). The second involves assembly issues of initializing in 1 G and retaining in 0 G an aggregate segmented mirror (coherent phasing between individual segments). Using a rectangular coordinate system at the vertex of a mirror segment, the rigid body motions are the six translational and rotational degrees of freedom. A first cut primary mirror wavefront error budget is presented. For a minimum operational wavelength of 30 micrometers, the derived values from the budget are: segment surface quality (0.45 micrometers RMS), radius mismatch (50 PPM), segment piston error (1.3 micrometers, segment tip/tilt error (0.6 microrad). Either active or passive segmented mirrors can be addressed, but if the surface quality of the off-axis segment and the radius matching requirements can be passively met, then only segment alignment need be sensed and controlled during operation in orbit. For the active mirror case, dimensional stability of the mirror material during operation is a key factor in establishing the degree of active figure control required.

Jones, Peter A.↗

Diffraction, chopping, and background subtraction for LDR

The Large Deployable Reflector (LDR) will be an extremely sensitive infrared telescope if the noise due to the photons in the large thermal background is the only limiting factor. For observations with a 3 arcsec aperture in a broadband at 100 micrometers, a 20-meter LDR will emit 10(exp 12) per second, while the photon noise limited sensitivity in a deep survey observation will be 3,000 photons per second. Thus the background subtraction has to work at the 1 part per billion level. Very small amounts of scattered or diffracted energy can be significant if they are modulated by the chopper. The results are presented for 1-D and 2-D diffraction calculations for the lightweight, low-cost LDR concept that uses an active chopping quaternary to correct the wavefront errors introduced by the primary. Fourier transforms were used to evaluate the diffraction of 1 mm waves through this system. Unbalanced signals due to dust and thermal gradients were also studied.

Wright, Edward L.↗

The Hubble Space Telescope optical systems failure report

The findings of the Hubble Space Telescope Optical Systems Board of Investigation are reported. The Board was formed to determine the cause of the flaw in the telescope, how it occurred, and why it was not detected before launch. The Board conducted its investigation to include interviews with personnel involved in the fabrication and test of the telescope, review of documentation, and analysis and test of the equipment used in the fabrication of the telescope's mirrors. The investigation proved that the primary mirror was made in the wrong shape (a 0.4-wave rms wavefront error at 632.8 nm). The primary mirror was manufactured by the Perkin-Elmer Corporation (Hughes Danbury Optical Systems, Inc.). The critical optics used as a template in shaping the mirror, the reflective null corrector (RNC), consisted of two small mirrors and a lens. This unit had been preserved by the manufacturer exactly as it was during the manufacture of the mirror. When the Board measured the RNC, the lens was incorrectly spaced from the mirrors. Calculations of the effect of such displacement on the primary mirror show that the measured amount, 1.3 mm, accounts in detail for the amount and character of the observed image blurring. No verification of the reflective null corrector's dimensions was carried out by Perkin-Elmer after the original assembly. There were, however, clear indications of the problem from auxiliary optical tests made at the time. A special optical unit called an inverse null corrector, designed to mimic the reflection from a perfect primary mirror, was built and used to align the apparatus; when so used, it clearly showed the error in the reflective null corrector. A second null corrector was used to measure the vertex radius of the finished primary mirror. It, too, clearly showed the error in the primary mirror. Both indicators of error were discounted at the time as being themselves flawed. The Perkin-Elmer plan for fabricating the primary mirror placed complete reliance on the reflective null corrector as the only test to be used in both manufacturing and verifying the mirror's surface with the required precision. This methodology should have alerted NASA management to the fragility of the process and the possibility of gross error. Such errors had been seen in other telescope programs, yet no independent tests were planned, although some simple tests to protect against major error were considered and rejected. During the critical time period, there was great concern about cost and schedule, which further inhibited consideration of independent tests.

Source record↗

The precision segmented reflectors: Moderate mission figure control subsystem

A system concept for a space based segmented reflector telescope figure control subsystem is described. The concept employs a two phase architecture in which figure initialization and figure maintenance are independent functions. Figure initialization is accomplished by image sharpening using natural reference targets. Figure maintenance is performed by monitoring the relative positions and alignments of the telescope components using an optical truss. Actuation is achieved using precision positioners. Computer simulation results of figure initialization by pairwise segment coalignment/cophasing and simulated annealing are presented along with figure maintenance results using a wavefront error regulation algorithm. Both functions are shown to perform at acceptable levels for the class of submillimeter telescopes that are serving as the focus of this technology development effort. Component breadboard work as well as plans for a system testbed are discussed.

Sevaston, G.↗

A comparison of performance of lightweight mirrors

Four lightweight solid contoured back mirror shapes (a double arch, a single arch, a modified single arch, and a double concave mirror) and a cellular sandwich lightweight meniscus mirror, have been considered for the primary mirror of the Space Infrared Telescope Facility (SIRTF). A parametric design study using these shapes for the SIRTF 40 inch primary mirror with a focal ratio f/2 is presented. Evaluations of the optical performance and fundamental frequency analyses are performed to compare relative merits of each mirror configuration. Included in these are structural, optical, and frequency analyses for (1) different back contour shapes, (2) different number and location of the support points, and (3) two gravity orientations (ZENITH and HORIZON positions). The finite element program NASTRAN is used to obtain the structural deflections of the optical surface. For wavefront error analysis, FRINGE and PCFRINGE programs are used to evaluate the optical performance. A scaling law relating the optical and structural performance for various mirror contoured back shapes is developed.

Cho, Myung K.↗

Modeling and measurement of a micro-optic beam deflector

The use is studied of a unity-magnification micro-optic beam deflector. The defelector consists of two arrays of positively powered lenslets. The lenslets on each array are arranged in a square grid. Design criteria are based on usefulness in optical data storage devices. The deflector is designed to operate over a + or - 1.6 range of deflection angles. Modeling results are compared with interferometric analysis of the wavefront from a single lenslet pair. The results indicate that the device is nearly diffraction limited, but there are substantial wavefront errors at the edges and corners of the lenslets.

Milster, Tom D.↗

LUTE primary mirror materials and design study report

The major objective of the Lunar Ultraviolet Telescope Experiment (LUTE) Primary Mirror Materials and Design Study is to investigate the feasibility of the LUTE telescope primary mirror. A systematic approach to accomplish this key goal was taken by first understanding the optical, thermal, and structural requirements and then deriving the critical primary mirror-level requirements for ground testing, launch, and lunar operations. After summarizing the results in those requirements which drove the selection of material and the design for the primary mirror are discussed. Most important of these are the optical design which was assumed to be the MSFC baseline (i.e. 3 mirror optical system), telescope wavefront error (WFE) allocations, the telescope weight budget, and the LUTE operational temperature ranges. Mechanical load levels, reflectance and microroughness issues, and options for the LUTE metering structure were discussed and an outline for the LUTE telescope sub-system design specification was initiated. The primary mirror analysis and results are presented. The six material substrate candidates are discussed and four distinct mirror geometries which are considered are shown. With these materials and configurations together with varying the location of the mirror support points, a total of 42 possible primary mirror designs resulted. The polishability of each substrate candidate was investigated and a usage history of 0.5 meter and larger precision cryogenic mirrors (the operational low end LUTE temperature of 60 K is the reason we feel a survey of cryogenic mirrors is appropriate) that were flown or tested are presented.

Ruthven, Greg↗

A wavefront compensation approach to segmented mirror figure control

We consider the 'figure-control' problem for a spaceborn sub-millimeter wave telescope, the Precision Segmented Reflector Project Focus Mission Telescope. We show that performance of any figure control system is subject to limits on the controllability and observability of the quality of the wavefront. We present a wavefront-compensation method for the Focus Mission Telescope which uses mirror-figure sensors and three-axis segment actuator to directly minimize wavefront errors due to segment position errors. This approach shows significantly better performance when compared with a panel-state-compensation approach.

Redding, David↗

Segmented mirror figure control for a space-based far-IR astronomical telescope

For segmented large mirrors to be used effectively for astronomy they must be actively aligned and controlled to extreme levels of precision. We consider the figure control problem for a spaceborne far-IR telescope, the Precision Segmented Reflector Project Focus Moderate Mission Telescope. We propose a two-stage approach. A figure initialization controller is used to achieve initial phasing and alignment of the telescope using an imaging science detector. A figure maintenance controller keeps the telescope aligned during normal operation using a laser metrology optical truss sensor system. We show that performance of any figure control system is subject to limits on the controllability of the wavefront. Maintenance controllers are additionally limited by considerations of the observability of the wavefront from the maintenance sensors. We show preliminary results for the figure initialization controller. We present a 'Wavefront Compensation' method for figure maintenance control that minimizes wavefront errors due to misalignment errors.

Redding, David↗

Accuracy requirements of optical linear algebra processors in adaptive optics imaging systems

A ground-based adaptive optics imaging telescope system attempts to improve image quality by detecting and correcting for atmospherically induced wavefront aberrations. The required control computations during each cycle will take a finite amount of time. Longer time delays result in larger values of residual wavefront error variance since the atmosphere continues to change during that time. Thus an optical processor may be well-suited for this task. This paper presents a study of the accuracy requirements in a general optical processor that will make it competitive with, or superior to, a conventional digital computer for the adaptive optics application. An optimization of the adaptive optics correction algorithm with respect to an optical processor's degree of accuracy is also briefly discussed.

Downie, John D.↗

Diffractive Optical Elements for Lidar Beam Scanning

Wind measurement from space can provide critical data for understanding weather patterns and large-scale storm phenomena. An instrument for providing such measurements is currently under development at NASA's Marshall Space Flight Center. The instrument utilizes a pulsed coherent lidar system operating at a wavelength of 2.06 micrometers in order to achieve decreased weight, size, and cost compared to systems operating at longer wavelengths, and it is being developed to be compatible with the capabilities of small satellites. A key aspect of such an orbital lidar system is that the beam must be conically scanned after it exits the final beam expansion telescope. Previous work indicates that the aperture of the beam expansion telescope should be 50 cm with a scanner half-angle of 300 and a rotation rate of 10 RPM. The critical requirements for the beam scanning element include a 50 cm aperture, an induced wavefront error of less than lambda/10, and high efficiency deflection (i.e., 95+ % of the incident light is deflected). This report is intended to provide a brief overview and discussion of potential technologies for space-borne laser radar (lidar) beam scanning.

Nordin, Gregory P.↗

The Case for Aggressive Segmentation of the Primary Mirror of the Next Generation Space Telescope and Future ORIGINS Missions

Optical performance variations are considered from several factors including the gap between regular hexagonal mirror segments, the relative ability of segments of different size to be manufactured with low wavefront error, and expected mirror deformations. Additionally a weight variation function will be driven by recently postulated relationships which can be expressed so as to determine thickness of the mirror segment to satisfy: (1) polishing pressures (2) 1-g sage deflection, and (3) thermal induced stress as well as ancillary masses including actuators, wiring, and electronics. The result will be to survey the trade space of segment number and size for a range of apertures from 4 to 20 meters.

Montgomery, Edward E., IV↗

Extra-Solar Planetary Imager (ESPI) for Space Based Jovian Planetary Detection

We report on out Extra-Solar Planetary Imager (ESPI) study for a recent Midex (NASA Medium Class Explorer Mission) proposal. Proposed for ESPI was a 1.5 x 1.5 square meter Jacquinot apodized square aperture telescope. The combination of apodization and a square aperture telescope significantly reduces the diffracted light from a bright central source over much of the telescope focal plane. As a result, observations of very faint astronomical objects next to bright sources with angular separations as small as 0.32 arcseconds become possible. This permits a sensitive search for exo-planets in reflected light. The system is capable of detecting a Jupiter-like planet in a relatively long-period orbit around as many as 160 to 175 stars with a signal-to-noise ratio greater than 5 in observations lasting maximally 100 hours per star. We discuss the effects of wavefront error, mirror speckle, pointing error and signal-to-noise issues, as well as the scalability of our ESPI study with respect to NASA's Terrestrial Planet Finder mission.

Lyon, Rick G.↗

Ambient and Cryogenic Alignment Verification and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a facility instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low- to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial Micro Electro-Mechanical Systems (MEMS) Digital Micro-mirror Device (DMD) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and the ambient and cryogenic imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve to venfy alignment, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides further verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides spectral lines at 546.1 nm and 1550 nm, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard test results validate this prediction. We conclude with an instrument performance prediction for first light.

Connelly, Joseph A.↗

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.↗