Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Lake Superior water quality near Duluth from analysis of aerial photos and ERTS imagery

ERTS imagery of Lake Superior in the late summer of 1972 shows dirty water near the city of Duluth. Water samples and simultaneous photographs were taken on three separate days following a heavy storm which caused muddy runoff water. The water samples were analyzed for turbidity, color, and solids. Reflectance and transmittance characteristics of the water samples were determined with a spectrophotometer apparatus. This same apparatus attached to a microdensitometer was used to analyze the photographs for the approximate colors or wavelengths of reflected energy that caused the exposure. Although other parameters do correlate for any one particular day, it is only the water quality parameter of turbidity that correlates with the aerial imagery on all days, as the character of the dirty water changes due to settling and mixing.

Scherz, J. P.↗

Use of Thematic Mapper for water quality assessment

The evaluation of simulated TM data obtained on an ER-2 aircraft at twenty-five predesignated sample sites for mapping water quality factors such as conductivity, pH, suspended solids, turbidity, temperature, and depth, is discussed. Using a multiple regression for the seven TM bands, an equation is developed for the suspended solids. TM bands 1, 2, 3, 4, and 6 are used with logarithm conductivity in a multiple regression. The assessment of regression equations for a high coefficient of determination (R-squared) and statistical significance is considered. Confidence intervals about the mean regression point are calculated in order to assess the robustness of the regressions used for mapping conductivity, turbidity, and suspended solids, and by regressing random subsamples of sites and comparing the resultant range of R-squared, cross validation is conducted.

Horn, E. M.↗

Synthetic Hyperspectral Data for Global Water Quality Algorithm Development

Eutrophication and increasing prevalence of potentially toxic algal blooms (cyanoHABs) among global inland water bodies have become a major ecological concern and require direct attention. There is now a growing necessity to develop pragmatic approaches that allow timely and effective extrapolation of local aquatic processes, to spatially resolved global products. Planned aquatic biogeochemistry remote sensing data products from hyperspectral imagers such as NASA’s Surface Biology and Geology (SBG) mission and relevant aquatic sensor sensitivity precursor airborne imaging spectrometer data provide unprecedented radiometric resolution and sensor sensitivity for characterizing complex aquatic ecosystems. However, scarcity of high-quality freshwater in-situ optical data hinders our capability to develop and validate robust retrieval algorithms. A state-of-the-art synthetic dataset of paired top-of-atmosphere, bottom-of-atmosphere, and optical and biogeophysical data was developed through radiative transfer modeling to simulate natural freshwater ecosystems. A synthetic or precursor dataset for SBG is being used to train robust machine learning models to derive water quality products pertinent to SBG mission objectives. The dataset is also used to show the potential of performing vigorous aquatic sensitivity studies and explored pathways for how best to optimize hyperspectral data for machine learning development. A processing pipeline and resultant global synthetic/precursor dataset for inland waters is presented to establish the innovation for water quality studies of inland waters globally. Optical Society of America Imaging and Applied Optics Congress, Hyperspectral Imaging and Sounding of the Environment (OSA HISE) Meeting, 19-23 July 2021, Virtual Meeting, https://www.osa.org/enus/meetings/osa_meetings/optical_sensors_and_sensing_congress/program/hyperspectral_imaging_and_sounding_of_the_environm/

Synthetic↗

A chemical sensor and biosensor based totally automated water quality monitor for extended space flight: Step 1

The result of a literature search to consider what technologies should be represented in a totally automated water quality monitor for extended space flight is presented. It is the result of the first summer in a three year JOVE project. The next step will be to build a test platform at the Authors' school, St. John Fisher College. This will involve undergraduates in NASA related research. The test flow injection analysis system will be used to test the detection limit of sensors and the performance of sensors in groups. Sensor companies and research groups will be encouraged to produce sensors which are not currently available and are needed for this project.

Smith, Robert S.↗

Water quality indicators obtainable from aircraft and Landsat images and their use in classifying lakes

Equations describing the interaction of sunlight and skylight with the surface of a lake, particles in the water to the depth where light is extinguished, and lake bottom are presented, and the use of aircraft and Landsat images to derive water quality indicators on the basis of these interactions is discussed. A very clear, deep lake with a backscatter signal similar to that of distilled water is used as a reference standard. The degree of turbidity of other target lakes is determined by comparing their residual radiance with the clear lake standard and with the residual radiance of a lake whose turbidity has been determined from water samples. The relative and absolute strengths of residual radiance are used to determine the type and concentration of suspended material, respectively. Oil slicks are characterized by an increased specular reflectance component, decreased signal from the underlying water, and added backscatter signal from the oil volume.

Scherz, J. P.↗

Space Station Environmental Health System water quality monitoring

One of the unique aspects of the Space Station is that it will be a totally encapsulated environment and the air and water supplies will be reclaimed for reuse. The Environmental Health System, a subsystem of CHeCS (Crew Health Care System), must monitor the air and water on board the Space Station Freedom to verify that the quality is adequate for crew safety. Specifically, the Water Quality Subsystem will analyze the potable and hygiene water supplies regularly for organic, inorganic, particulate, and microbial contamination. The equipment selected to perform these analyses will be commercially available instruments which will be converted for use on board the Space Station Freedom. Therefore, the commercial hardware will be analyzed to identify the gravity dependent functions and modified to eliminate them. The selection, analysis, and conversion of the off-the-shelf equipment for monitoring the Space Station reclaimed water creates a challenging project for the Water Quality engineers and scientists.

Vincze, Johanna E.↗

Performance characterization of water recovery and water quality from chemical/organic waste products

The water reclamation subsystems currently being evaluated for the Space Shuttle Freedom are briefly reviewed with emphasis on a waste water management system capable of processing wastes containing high concentrations of organic/inorganic materials. The process combines low temperature/pressure to vaporize water with high temperature catalytic oxidation to decompose volatile organics. The reclaimed water is of potable quality and has high potential for maintenance under sterile conditions. Results from preliminary experiments and modifications in process and equipment required to control reliability and repeatability of system operation are presented.

Moses, W. M.↗

Water quality modeling using geographic information system (GIS) data

Protection of the environment and natural resources at the Kennedy Space Center (KSC) is of great concern. The potential for surface and ground water quality problems resulting from non-point sources of pollution was examined using models. Since spatial variation of parameters required was important, geographic information systems (GIS) and their data were used. The potential for groundwater contamination was examined using the SEEPAGE (System for Early Evaluation of the Pollution Potential of Agricultural Groundwater Environments) model. A watershed near the VAB was selected to examine potential for surface water pollution and erosion using the AGNPS (Agricultural Non-Point Source Pollution) model.

Engel, Bernard A↗

Quantitative water quality with ERTS-1

Analyses of ERTS-1 MSS computer compatible tapes of reservoir scenes in Kansas along with ground truth show that MSS bands and band ratios can be used for reliable prediction of suspended loads up to at least 900 ppm. The major reservoirs in Kansas, as well as in other Great Plains states, are playing increasingly important roles in flood control, recreation, agriculture, and urban water supply. Satellite imagery is proving useful for acquiring timely low cost water quality data required for optimum management of these fresh water resources.

Yarger, H. L.↗

Application of remote sensing in the determination of water quality in Nebraska reservoirs

In June, July, and August, 1975, ground truth was collected from Lake McConaughy, a 35,000 acre reservoir in western Nebraska, coincident with the overflights of LANDSAT. Water samples were collected on six different dates and analyzed for turbidity, suspended solids, and chlorophyll, parameters which had correlated well with CCT reflectances. The correlations and regressions reported were derived from data obtained on only three of the six sampling dates. The radiance values from each of the four spectral bands were printed out in the form of a map of Lake McConaughy. Reflectances in the various bands were then obtained from the map at the appropriate sampling sites. The dependent variables chlorophyll, suspended solids, and turbidity were compared to the independent variables - reflectances in the four bands - by regression analysis. Both multiple and univariate regressions were examined. It is concluded that CCT's from LANDSAT can be used to detect and quantify the water quality parameters suspended solids, turbidity, and chlorophyll.

Hergenrader, G. L.↗

A dual polarization laser backscatter system for water quality studies.

Demonstration of the feasibility of a described, small, low power lidar polarimeter system for straight line scans from low altitude flights in daylight. Such a system should be useful for water quality measurements in conjunction with passive photographic or multispectral scanner systems.

Mayo, W. T., Jr.↗

Rapid toxicity detection in water quality control utilizing automated multispecies biomonitoring for permanent space stations

The objective of this study was to evaluate proposed design characteristics and applications of automated biomonitoring devices for real-time toxicity detection in water quality control on-board permanent space stations. Simulated tests in downlinking transmissions of automated biomonitoring data to Earth-receiving stations were simulated using satellite data transmissions from remote Earth-based stations.

Morgan, E. L.↗

Canaveral National Seashore Water Quality and Aquatic Resource Inventory

Mosquito Lagoon is a shallow, bar-built estuary located on the east central Florida Coast, primarily within the KSC boundary. The lagoon and watershed cover approximately 327 sq km (79422 acres) .The Lagoon occupies 159 sq km (37853 acres). Water depths average approximately 1m. The lagoon volume is approximately 1.6 x 10(exp 8)cu m. Water quality in Mosquito Lagoon is good. Salinity data typically range between 20 ppt and 35 ppt. The lowest value recorded was 4.5 ppt and the highest value was 37 ppt. Water temperatures fluctuate 2 - 3 C over a 24 h period. Cold front passage can rapidly alter water temperatures by 5 - 10 C or more in a short period of time. The highest temperature was 33.4 C and the lowest temperature was 8.8 C after a winter storm. Dissolved oxygen concentrations ranged from a low of 0.4 mg/l to a high of 15.3 mg/l. Extended periods of measurements below the Florida Department of Environmental Protection criteria of 4.0 mg/l were observed in fall and spring months suggesting high system respiration and oxygen demand. Metals such as antimony, arsenic, molybdenum and mercury were report as below detection limits for all samples. Cadmium, copper, chromium, silver, and zinc were found to be periodically above the Florida Department of Environmental Protection criteria for Class II and Class III surface waters.

Hall, C. R.↗

Photographic quantification of water quality in mixing zones

A method was developed to quantitatively delineate waste concentrations throughout waste effluent mixing zones on the basis of densitometric measurements extracted from aerial photography. A mixing zone is the extent of a receiving water body ultilized to dilute a waste discharge to a concentration characteristic of a totally mixed condition. Simultaneously-acquired color infrared photography and suspended solids water samples were used to quantitatively delineate the mixing zone resulting from the discharge of a paper mill effluent. Digital scanning microdensitometer data was used to estimate and delineate suspended solids concentrations on the basis of a semi-empirical model. Photographic photometry, when predicated on a limited amount of ground sampling, can measure and delineate mixing zone waste distributions in more detail then conventional surface measuring techniques. The method has direct application to: (1) the establishment of definite and rational water quality guidelines; (2) the development of sampling and surveillance programs for use by governmental and private agencies; and (3) the development of design and location criteria for industrial and municipal waste effluent outfalls.

Lillesand, T. M.↗

Remote sensing of effects of land use practices on water quality

An intensive study was conducted to determine the utility of manual densitometry and color additive viewing of aircraft and LANDSAT transparencies for monitoring land use and land use change. The relationship between land use and selected water quality parameters was also evaluated. Six watersheds located in the Cumberland Plateau region of eastern Kentucky comprised the study area for the project. Land uses present within the study area were reclaimed surface mining and forestry. Fertilization of one of the forested watersheds also occurred during the study period.

Graves, D. H.↗

Systems Analyze Water Quality in Real Time

A water analyzer developed under Small Business Innovation Research (SBIR) contracts with Kennedy Space Center now monitors treatment processes at water and wastewater facilities around the world. Originally designed to provide real-time detection of nutrient levels in hydroponic solutions for growing plants in space, the ChemScan analyzer, produced by ASA Analytics Inc., of Waukesha, Wisconsin, utilizes spectrometry and chemometric algorithms to automatically analyze multiple parameters in the water treatment process with little need for maintenance, calibration, or operator intervention. The company has experienced a compound annual growth rate of 40 percent over its 15-year history as a direct result of the technology's success.

Source record↗

Efforts to Reduce International Space Station Crew Maintenance Time in the Management of the Extravehicular Mobility Unit Transport Loop Water Quality

The EMU (Extravehicular Mobility Unit) contains a semi-closed-loop re-circulating water circuit (Transport Loop) to absorb heat into a LCVG (Liquid Coolant and Ventilation Garment) worn by the astronaut. A second, single-pass water circuit (Feed-water Loop) provides water to a cooling device (Sublimator) containing porous plates, and that water sublimates through the porous plates to space vacuum. The cooling effect from the sublimation of this water translates to a cooling of the LCVG water that circulates through the Sublimator. The quality of the EMU Transport Loop water is maintained through the use of a water processing kit (ALCLR - Airlock Cooling Loop Remediation) that is used to periodically clean and disinfect the water circuit. Opportunities to reduce crew time associated with ALCLR operations include a detailed review of the historical water quality data for evidence to support an extension to the implementation cycle. Furthermore, an EMU returned after 2-years of use on the ISS (International Space Station) is being used as a test bed to evaluate the results of extended and repeated ALCLR implementation cycles. Finally, design, use and on-orbit location enhancements to the ALCLR kit components are being considered to allow the implementation cycle to occur in parallel with other EMU maintenance and check-out activities, and to extend the life of the ALCLR kit components. These efforts are undertaken to reduce the crew-time and logistics burdens for the EMU, while ensuring the long-term health of the EMU water circuits for a post- Shuttle 6-year service life.

Etter,David↗