Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WOUNDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Digital-computer program for design analysis of salient, wound pole alternators

A digital computer program for analyzing the electromagnetic design of salient, wound pole alternators is presented. The program, which is written in FORTRAN 4, calculates the open-circuit saturation curve, the field-current requirements at rated voltage for various loads and losses, efficiency, reactances, time constants, and weights. The methods used to calculate some of these items are presented or appropriate references are cited. Instructions for using the program and typical program input and output for an alternator design are given, and an alphabetical list of most FORTRAN symbols and the complete program listing with flow charts are included.

Repas, D. S.↗

Acoustic emission produced during burst tests of filament-wound bottles.

Acoustic emission was recorded during burst tests of filament-wound, composite pressure vessels. Organic and graphite fibers were tested, and two different epoxy resin systems were used: one with a low and another with a relatively high cure temperature. Acoustic emission was studied for the effects of different winding patterns, artificial flaws, winding-induced fiber fraying, different resins, and different fibers. Small effects produced in the vessels by changes in these variables were greatly magnified when they appeared as changes in acoustic emission. They would, in fact, be difficult or impossible to detect by other test means.

Hamstad, M. A.↗

Filament-wound composite vessel materials technology

Review of recent developments in advanced filament-wound fiber/resin composite vessel technology for cryogen and high-pressure gas containment applications. Design and fabrication procedures have been developed for small-diameter closed-end vessels equipped with thin elastomeric or thin metallic liners. Specific results are discussed.

Lark, R. F.↗

Polymer-lined filament-wound pressure vessels for nitrogen containment

A program has been started to develop fatigue-resistant polymeric liners for a filament-wound pressure vessel to contain nitrogen gas at room temperature. First, nitrogen permeation of butyl rubber sheet coated with Saran and Parylene C was studied in flat specimens. Then four 10-cm-diam cylindrical pressure vessels were prepared with chlorobutyl rubber liners coated with the same materials. These vessels were valved off after nitrogen gas pressurization to approximately 65% (approximately 11.7 MPa or 1700 psig) of their expected failure pressure. One vessel leaked. The other three vessels showed an average pressure loss of less than 1% per month. These pressure vessels have an average performance factor of approximately 370 kPa-cu m/kg (1,500,000 in.) based on composite mass.

Hamstad, M. A.↗

Position sensing materials wound on a reel

Electro-optical counter measures number of layers of web wound on reel and indicates layer number and web position digitally, without physically contacting reel or requiring numerical interpolation from mechanical readout device.

Muller, R. M.↗

Polymer-lined filament-wound pressure vessels for nitrogen containment

A program has been started to develop fatigue-resistant polymeric liners for a filament-wound pressure vessel to contain nitrogen gas at room temperature. First, nitrogen permeation of butyl rubber sheet coated with Saran and Parylene C was studied in flat specimens. Then four 10-cm-diam cylindrical pressure vessels were prepared with chlorobutyl rubber liners coated with the same materials. These vessels were valved off after nitrogen gas pressurization to approximately 65% of their expected failure pressure. One vessel leaked. The other three vessels showed an average pressure loss of less than 1% per month. These pressure vessels have an average performance factor of about 370 kPa x cu m/kg based on composite mass.

Hamstad, M. A.↗

Filament wound rocket motor chambers

The design, analysis, fabrication and testing of a Kevlar-49/HBRF-55A filament wound chamber is reported. The chamber was fabricated and successfully tested to 80% of the design burst pressure. Results of the data reduction and analysis from the hydrotest indicate that the chamber design and fabrication techniques used for the chamber were adequate and the chamber should perform adequately in a static test.

Source record↗

Recent advances in lightweight, filament-wound composite pressure vessel technology

A review of recent advances is presented for lightweight, high performance composite pressure vessel technology that covers the areas of design concepts, fabrication procedures, applications, and performance of vessels subjected to single cycle burst and cyclic fatigue loading. Filament wound fiber/epoxy composite vessels were made from S glass, graphite, and Kevlar 49 fibers and were equipped with both structural and nonstructural liners. Pressure vessels structural efficiencies were attained which represented weight savings, using different liners, of 40 to 60 percent over all titanium pressure vessels. Significant findings in each area are summarized.

Lark, R. F.↗

Insulation end life determination for completed form-wound generators

Tests were conducted to predict remaining electrical insulation life of a polyimide-epoxy insulated 60 kW form-wound homopolar inductor generator following completion of 23,130 hours of turbo-generator endurance tests. The generator stator was sectioned to provide five sections, designated statorettes, and to permit 33 coil dielectric measurements on each section. Thermal aging tests were conducted on each section at select elevated temperatures to establish an Arrhenius life-temperature plot for end-life prediction and product or application use. The statorette fabrication technique is considered novel and provides means to establish insulation life-temperature profiles on completed electromagnetic components of rotating machines.

Penn, W. B.↗

Filament wound pressure vessels with load sharing liners for Space Shuttle Orbiter applications

It is recognized that the use of overwrapped pressure vessels with load sharing liners may provide significant weight savings for high pressure gas containment in Space Shuttle Orbiter systems. The technology readiness to produce Kevlar wound vessels with load sharing liners of titanium 6Al-4V, Inconel 718 or cryoformed 301 steel has been demonstrated. It has been estimated that about 400 lbs can be saved in the Orbiter by using overwrapped vessels with load sharing liners instead of monolithic metal designs. Total weight of the composite vessels would be about 1350 lbs as opposed to about 1750 lbs for all-metal vessels.

Ecord, G. M.↗

Impact behavior of filament wound graphite/epoxy fan blades

The fabrication and impact tests of graphite/epoxy filament wound fan blades are discussed. Blades which were spin tested at tip speeds up to 305 meters per second retained their structural integrity. Two blades were each impacted with a 454 gram slice of a 908 gram simulated bird at a tip speed of 263 meters per second and impact angles of 22 and 32 deg. The impact tests were recorded with high-speed movie film. The blade which was impacted at 22 deg sustained some root delamination but remained intact. The 32 deg impact separated the blade from the root. No local damage other than leading edge debonding was observed for either blade. Results of a failure mode analysis are also discussed.

Bowles, K. J.↗

Recent advances in lightweight, filament-wound composite pressure vessel technology

A review of recent advances is presented for lightweight, high-performance composite pressure vessel technology that covers the areas of design concepts, fabrication procedures, applications, and performance of vessels subjected to single-cycle burst and cyclic fatigue loading. Filament-wound fiber/epoxy composite vessels were made from S-glass, graphite, and Kevlar 49 fibers and were equipped with both structural and nonstructural liners. Pressure vessel structural efficiencies were attained which represented weight savings, using different liners, of 40 to 60 percent over all-titanium pressure vessels. Significant findings in each area are summarized including data from current NASA-Lewis Research Center contractual and in-house programs.

Lark, R. F.↗

Variabilities detected by acoustic emission from filament-wound Aramid fiber/epoxy composite pressure vessels

Two hundred and fifty Aramid fiber/epoxy pressure vessels were filament-wound over spherical aluminum mandrels under controlled conditions typical for advanced filament-winding. A random set of 30 vessels was proof-tested to 74% of the expected burst pressure; acoustic emission data were obtained during the proof test. A specially designed fixture was used to permit in situ calibration of the acoustic emission system for each vessel by the fracture of a 4-mm length of pencil lead (0.3 mm in diameter) which was in contact with the vessel. Acoustic emission signatures obtained during testing showed larger than expected variabilities in the mechanical damage done during the proof tests. To date, identification of the cause of these variabilities has not been determined.

Hamstad, M. A.↗

Impact behavior of filament-wound graphite/epoxy fan blades

The fabrication and impact tests of graphite/epoxy filament wound fan blades are discussed. Blades which were spin tested at tip speeds up to 305 m/sec retained their structural integrity. Two blades were each impacted with a 454-g slice of a 908-g simulated bird at a tip speed of 263 deg and impact angles of 22 deg and 32 deg. The impact tests were recorded with high-speed movie film. The blade which was impacted at 22 deg sustained some root delamination but remained intact. The 32 deg impact separated the blade from the root. No local damage other than leading-edge debonding was observed for either blade. The results of a failure mode analysis are also discussed.

Bowles, K. J.↗

Spiral-wound gasket forms low-temperature seal

Spiral-wound cryogenic gasket with one component requires no encapsulant and is easily produced with self-locking features. Seal either opens and closes or is fixed. It is made by skiving strip from circumference of disk of glass-filled material. Successive turns of strip are spirally wrapped in groove machined into one flange surface. Closing joint compresses gasket.

Irick, S. C.↗

Modified spiral wound retaining ring

A spiral wound retaining ring with angled ends is described. The ring is crimped at the same angle as the ring ends to maintain a constant thickness dimension. The angling of the ends of the ring and crimp allow the ends to be positioned closer together while maintaining enough clearance to enable insertion and removal of the ring. By reducing the separation distance between the ends a stronger ring results since the double layer area of the ring is maximized.

Lawson, A. G.↗

A mathematical model for the doubly fed wound rotor generator

A mathematical analysis of a doubly-fed wound rotor machine used as a constant frequency generator is presented. The purpose of this analysis is to derive a consistent set of circuit equations which produce constant stator frequency and constant stator voltage. Starting with instantaneous circuit equations, the necessary rotor voltages and currents are derived. The model, thus obtained, is assumed to be valid, since the resulting relationships between mechanical power and active volt-amperes agrees with the results of others. In addition, the model allows for a new interpretation of the power flow in the doubly-fed generator.

Brady, F. J.↗

A mathematical model for the doubly-fed wound rotor generator, part 2

A mathematical analysis of a doubly-fed wound rotor generator is presented. The constraints of constant stator voltage and frequency to the circuit equations were applied and expressions for the currents and voltages in the machine obtained. The derived variables are redefined as direct and quadrature components. In addition, the apparent (complex) power for both the rotor and the stator are derived in terms of these redefined components.

Brady, F. J.↗