Characterizing Effects of Witness Marks in L-PBF
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Novel neutron detectors are needed for neutron science and nonproliferation. Neutrons imaging complements X-ray imaging by providing contrast to light events and transparency high-Z elements.
Plasma-based acceleration (PBA) has emerged as a promising candidate for the accelerator technology used to build a future linear collider and/or an advanced light source. In PBA, a trailing or witness particle beam is accelerated in the plasma wave wakefield (WF) created by a laser or particle beam driver. The WF is often nonlinear and involves the crossing of plasma particle trajectories in real space and thus particle-in-cell methods are used. The distance over which the drive beam evolves is several orders of magnitude larger than the wake wavelength. This large disparity in length scales is amenable to the quasi-static approach. Three-dimensional (3D), quasi-static (QS), particle-in-cell (PIC) codes, e.g., QuickPIC, have been shown to provide high fidelity simulation capability with 2-4 orders of magnitude speedup over 3D fully explicit PIC codes. In PBA, the witness beam needs to be matched to the focusing forces of the WF to reduce the emittance growth. In some linear collider designs, the matched spot size of the witness beam can be 2 to 3 orders of magnitude smaller than the spot size (and wavelength) of the wakefield. Such an additional disparity in length scales is ideal for mesh refinement where the WF within the witness beam is described on a finer mesh than the rest of the WF. A mesh refinement scheme is described that has been implemented into the 3D QS PIC code, QuickPIC. Very fine (high) resolution is used in a small spatial region that includes the witness beam and progressively coarser resolutions in the rest of the simulation domain. A fast multigrid Poisson solver has been implemented for the field solve on the refined meshes and a Fast Fourier Transform (FFT) based Poisson solver is used for the coarse mesh. The code has been parallelized with both MPI and OpenMP, and the parallel scalability has also been improved by using pipelining. A preliminary adaptive mesh refinement technique is described to optimize the computational time for simulations with an evolving witness beam size. Several test problems are used to verify that the mesh refinement algorithm provides accurate results. Additionally, the results are benchmarked against highly resolved simulations exhibiting near-azimuthal symmetry, performed using QPAD—a novel hybrid QS PIC code that uses a PIC description in the coordinates (r, ct – z) and a gridless description in the azimuthal angle, Φ.
Homeland Security programs are developing systems that use nuclear resonance fluorescence (NRF) to isotopically map a container. One such system being developed at LLNL is FINDER (Fluorescence Imaging in the Nuclear Domain with Extreme Radiation). The proposed FINDER system works by impinging a tunable monoenergetic gamma ray beam onto a container under investigation. The photons pass through the container and a fraction of them scatter off of the interior components through various electromagnetic processes. One of these processes is NRF. At specific resonance energies, incident photons interact directly with the nuclei of special nuclear material (SNM) or other materials in the container. The incident beam is absorbed and scattered into all directions, depleting the spectrum at the resonant energy. The transmitted gamma ray beam accrues a notch a few eV in width after passing through the material of interest. This notched spectrum will impinge on a witness foil placed on the opposite side of the container relative to the gamma ray source. The witness foil will be made of material identical to the one being sought after. If there is a notch in the spectrum then there will be no NRF photons scattered from the witness foil. The corollary is that if there is no notch in the transmitted spectrum then there will be NRF photons scattered from the witness foil. A simple arrangement of gamma-ray detectors focused on the witness foil, are used to measure the NRF photons. If the detectors see NRF scatter then there was no NRF scatter within the container; therefore, no material of the nature being sought after was in that container. Conversely, if there was no NRF scatter from the witness foil, then the NRF scatter took place from within the container; therefore, the material of interest is inside of the container. Recently, initial feasibility tests of FINDER was performed at the HIgS (High-Intensity Gamma Source) located at Duke University [1]. The preliminary results of these tests are discussed in this report. Our goals for these measurements were to demonstrate the concept of transmission detection and perform some initial validation of models of the FINDER concept. In particular, our models [2] indicated that backgrounds and nuisances are too small to obscure the high signal to noise of the FINDER technique. Therefore, FINDER offers extremely clear positive and negative signals for detecting SNM when measuring the high contrast attenuation of on-resonance gamma rays in transmission. Our initial demonstration of transmission detection provides a first check on our models--e.g. is there a physical process that we have forgotten to include? Also, previous work indicated that the notch could be obscured by small-angle scattering refilling the notch if the interrogating photon source is too broad in energy. While we did not expect notch refilling to be significant at HIgS which provides beam of gamma rays with {Delta}E/E {approx} 3%, we were able to set an experimental upper limit on the amount of notch refilling in our experimental set up. This report first describes the experimental setup for these measurements, gives a summary of the important results, and then concludes by discussing the extent to which we were able to validate our models [2] of the FINDER technique.
The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (JSC), in Houston, TX (henceforth Curation Office) manages the curation of all past, present, and future extraterrestrial samples returned by NASA missions and shared collections from international partners, preserving their integrity for future scientific study while providing the samples to the international community in a fair and unbiased way. The Curation Office also curates all reference and witness materials for each mission (e.g., flight and non-flight hardware coupons; lubricants; non-flight, flight-like, and flown witness plates). These reference and witness materials provide the scientific community with the fundamental ability to reconstruct the contamination/alteration history of the sample collection through the course of the mission, with the overall goal of strengthening the scientific conclusions drawn from the study of returned materials. The information gained from characterizing the physical, biological, inorganic, and organic chemical properties of reference and witness materials is defined as the Contamination Knowledge (CK) of the sample collection. Unlike the data collected for Contamination Control (CC) and Planetary Protection (PP), CK is exclusively concerned with preserving reference and witness materials for study by future scientists upon sample return. Although CC and PP data collected for sample integrity and forward contamination purposes can be complementary to CK, they are two separate data sets with distinct objectives. A robust collection of samples for CK is necessary to allow the extraterrestrial material in a returned sample to be distinguished from terrestrial contamination. Traditionally CK is utilized by sample scientists in order to accomplish the mission’s scientific objectives, however this information can also be utilized by the Office of Planetary Protection to help evaluate the presence of any back contamination. Mars 2020, the first phase of a potential multipart Mars Sample Return (MSR) campaign, is expected to contribute to NASA’s Mars Exploration Program Science Goals by filling in knowledge gaps concerning: 1) the existence of past or present life on Mars, 2) the past and present climate of Mars, 3) the geology of Mars, and 4) hazards associated with human exploration of Mars. Although there is debate concerning which samples will best answer these questions, the necessity for proper sample blanks is well-understood. The CC and PP requirements, driven by the restricted Class V mission designation, are the most stringent of any sample return mission in recent history. The extremely low levels of allowable terrestrial contamination on the spacecraft and rover can complicate these analyses given the detection limits of current analytical instrumentation, especially in the case of biological contamination. By collecting and curating unanalyzed samples specifically for CK, future sample scientists will not be relegated to: 1) relying on data collected using possibly obsolete tools and techniques for return sample blanks, or 2) using remnants of extracted and/or cultured samples from ATLO (Assembly, Test, and Launch Operations), which could be incompatible with the desired experimental endpoints or state-of-the-art techniques available at the time of sample return.The addition of biological experimental endpoints to a sample return campaign’s objectives broadens the requisite range in preservation environments (e.g. inert ultra-pure nitrogen gaseous environment at 18 degrees Centigrade versus less than or equal to minus 80 degrees Centigrade) and types of CK samples. As a result, the Curation Office will also curate the following CK samples at less than or equal to minus 80 degrees Centigrade for the Mars 2020 mission: 1) unanalyzed swabs and wipes in sterile containers, 2) all recirculation filters from the clean rooms used for sample and caching subsystem assembly and all filters from the laminar flow benches used to assemble sample intimate hardware, and 3) witness plates collecting airborne contamination within the assembly clean rooms. It has been Curation Office policy since the Apollo missions to preserve as many pristine samples as possible for future scientific research. Although CK is required to be collected for all stages of the MSR campaign, the CK for the Mars 2020 mission is the most critical for understanding contamination in the returned samples given the intimacy between the Martian samples and the Mars 2020 flight hardware. This presentation highlights the importance of CK for sample return missions as well as the traditional and novel types of CK samples required for a successful MSR campaign.
A standard tensile test device is improved to accurately measure the mechanical properties of stranded cables, ropes, and other composite structures wherein a witness is attached to the top and bottom mounting blocks holding the cable under test. The witness is comprised of two parts: a top and a bottom rod of similar diameter with the bottom rod having a smaller diameter stem on its upper end and the top rod having a hollow opening in its lower end into which the stem fits forming a witness joint. A small gap is present between the top rod and the larger diameter portion of the bottom rod. A standard extensometer is attached to the top and bottom rods of the witness spanning this small witness gap. When a force is applied to separate the mounting blocks, the gap in the witness expands the same length that the entire test specimen is stretched.
A stochastic Petri-net model of a replicated file system is presented for a distributed environment where replicated files reside on different hosts and a voting algorithm is used to maintain consistency. Witnesses, which simply record the status of the file but contain no data, can be used in addition to or in place of files to reduce overhead. A model sufficiently detailed to include file status (current or out-of-date), as well as failure and repair of hosts where copies or witnesses reside, is presented. The number of copies and witnesses is a parameter of the model. Two different majority protocols are examined, one where a majority of all copies and witnesses is necessary to form a quorum, and the other where only a majority of the copies and witnesses on operational hosts is needed. The latter, known as adaptive voting, is shown to increase file availability in most cases.
The OSIRIS-REx asteroid sample return mission launched to asteroid Bennu Sept. 8, 2016. The spacecraft will arrive at Bennu in late 2019, orbit and map the asteroid, and perform a touch and go (TAG) sampling maneuver in July 2020. After sample is stowed and confirmed the spacecraft will return to Earth, and the sample return capsule (SRC) will land in Utah in September 2023. Samples will be recovered from Utah [2] and then transported and stored in a new sample cleanroom at NASA Johnson Space Center in Houston [3]. The materials curated for the mission are described here. a) Materials Archive and Witness Plate Collection: The SRC and TAGSAM were built between March 2014 and Summer of 2015, and instruments (OTES,OVIRS, OLA, OCAMS, REXIS) were integrated from Summer 2015 until May 2016. A total of 395 items were received for the materials archive at NASA-JSC, with archiving finishing ~30 days after launch (with the final archived items being related to launch operations)[4]. The materials fall into several general categories including metals (stainless steel, aluminum, titanium alloys, brass and BeCu alloy), epoxies, paints, polymers, lubricants, non-volatile-residue samples (NVR), sapphire, and various miscellaneous materials. All through the ATLO process (from March 2015 until late August 2016) contamination knowledge witness plates (Si wafer and Al foil) were deployed in the various cleanrooms in Denver and KSC to provide an additional record of particle counts and volatiles that is archived for current and future scientific studies. These plates were deployed in roughly monthly increments with each unit containing 4 Si wafers and 4 Al foils. We archived 128 individual witness plates (64 Si wafers and 64 Al foils); one of each witness plate (Si and Al) was analyzed immediately by the science team after archiving, while the remaining 3 of each are archived indefinitely. Information about each material archived is stored in an extensive database at NASA-JSC, and key summary information for each will be presented in an online catalog. b) Bulk Asteroid sample: The Touch and Go Sampling Mechanism (TAGSAM) head will contain up to 1.5 kg of asteroid material. Upon return to Earth, the TAGSAM head with the sample canister will be subjected to a nitrogen purge and then opened in a nitrogen cabinet in Houston. Once the TAGSAM head is removed from the canister, it will be dis-assembled slowly and carefully under nitrogen until the sample can be removed for processing in a dedicated nitrogen glovebox. Bennu surface samples are expected to be sub-cm sized, based on thermal infrared and radar polarization ratio measurements [1]. The upper limit on material collected by the TAGSAM head is ~2 cm. Therefore, we will be prepared to handle, subdivide, and characterize materials of a wide grain size (from ~10 m to 2 cm), and for both organic (UV fluorescence) and inorganic (SEM, FTIR, optical) properties. Representative portions of the bulk sample will be prepared for JAXA (0.5 %; see also [5]) and Canadian Space Agency (4%), with the remaining divided between the science team (<25%) and archived for future studies (NASA) (>75%). c) Contact Pad samples: The base of the TAGSAM head contains 24 contact pads that are designed to trap the upper surface layer of material and thus offer an opportunity to study asteroid samples that have resided at the very top surface of the regolith. Asteroid material is trapped on the pads in spring steel Velcro hooks, and material will have to be removed from these pads by curation specialists in the lab. d) Hardware: Some canister and SRC hardware items will contain information that will be important to understanding the collected samples, including the canister gas filter, temperature strips, flight witness plates, and the TAGSAM and canister parts that might have adhering dust grains. Some challenges remaining for both bulk sample and contact pad samples include: i) working with intermediate size range (200 to 500 micron) samples - a size range NASA has not previously worked in such detail; ii) techniques for removal of contact pad material from the spring steel hooks, iii) static electrical effects of dust sized particles during sample handling and curation is likely to be significant, and iv) the TAGSAM head and associated canister hardware will undoubtedly be coated with fine adhering dust grains from Bennu. In the case of collection of a large bulk sample mass, the adhering dust grains may be of lower priority. If a small sample mass is returned, the adhering dust may attain a higher priority, so recovery of adhering dust grains is an additional challenge to consider. In the year leading up to sample return we plan a variety of sample handling rehearsals that will enables the curation team to be prepared for many new aspects posed by this sample suite.
Additive manufacture (AM) is utilized for rocket engine component production. Witness marks are visible lines across the surface of an AM part that result from variation in build process. Witness marks have been used as justification to scrap a part with little to no evidence. The probability of witness mark occurrence is relatively high and greatly increases AM part production costs and schedule risks. The objective of this study was to quantify the impact of witness marks generated by intentional build pauses and characterize functional characteristics of the AM components. CT, μ-CT, metallographic, and mechanical test results indicate that witness marks are a surface phenomenon that do not propagate into the bulk of a part and had no statistically significant change on microstructure or properties in AlSi10Mg.
Indirectly driven shock-tube experiments were performed on the Omega Laser Facility to evaluate the relative importance of hohlraum x ray and radiative shock preheat sources on a low-density foam. X rays emitted from the hohlraum and a subsequent shock wave are channeled into a low-density foam sample, which contains a plastic preheat-witness disk placed downstream of the foam. Simultaneous radiographic measurements of the shock speed in the foam and the expansion rate of the witness disk due to preheat allow for the observation of effects from the hohlraum's low-energy and high-energy x-ray spectrum. Here we showed, from simulations, that low-energy x rays from the hohlraum are preferentially absorbed near the ablator surface (where the hohlraum and the shock tube meet), while higher-energy x rays largely pass through the ablator and foam and are volumetrically absorbed by the witness disk. Reproducing the experimentally measured shock speed and expansion of the witness disk simultaneously, we extracted the temperature evolution of preheated foam from the simulation and evaluated the relative importance of preheat sources on a low-density foam from hohlraum x-ray radiation and radiative shock. We found that radiation from the shock front was more effective at preheating the low-density foam than the high-energy x rays from the hohlraum. This shock-tube preheat experiment is important for understanding the results of the MARBLE experiments at the National Ignition Facility because initial conditions of foam-filled MARBLE capsules are sensitive to preheat.
Plasma-based acceleration (PBA) is being considered for a next generation linear collider (LC). In some PBA-LC designs for the electron arm, the extreme beam parameters are expected to trigger background ion motion within the witness beam, which can lead to longitudinally varying nonlinear focusing forces and result in an unacceptable emittance growth of the beam. To mitigate this, we propose to use quasi-adiabatic plasma density ramps as matching sections at the entrance and exit of each stage. We match the witness electron beam to the low density plasma entrance, where the beam initially has a large matched spot size so the ion motion effects are relatively small. As the beam propagates in the plasma density upramp, it is quasi-adiabatically focused, and its distribution maintains a non-Gaussian equilibrium distribution in each longitudinal slice throughout the process, even when severe ion collapse has occurred. This only causes small amounts of slice emittance growth. The phase mixing between slices with different betatron frequencies leads to additional projected emittance growth within the acceleration stage. A density downramp at the exit of an acceleration section can eliminate much of the slice and projected emittance growth as the beam and ion motion adiabatically defocuses and decreases, respectively. Simulation results from QuickPIC with Azimuthal Decomposition show that within a single acceleration stage with a 25 GeV energy gain, this concept can limit the projected emittance growth to only ∼2% for a 25 GeV, 100 nm emittance witness beam and ∼20% for a 100 GeV, 100 nm normalized emittance witness beam. The trade-off between the adiabaticity of the plasma density ramp and the initial ion motion at the entrance for a given length of the plasma density ramp is also discussed.
Here, we present a protocol for detecting multipartite entanglement in itinerant many-body electronic systems using single-particle Green’s functions. To achieve this, we first establish a connection between the quantum Fisher information and single-particle Green’s functions by constructing a set of witness operators built out of single electron creation and destruction operators in a doubled system. This set of witness operators is indexed by a momentum k. We compute the quantum Fisher information for these witness operators and show that for thermal ensembles it can be expressed as an autoconvolution of the single-particle spectral function. We then apply our framework to a one-dimensional fermionic system to showcase its effectiveness in detecting entanglement in itinerant electron models. We observe that the detected entanglement level is sensitive to the wave vector associated with witness operator. Our protocol will permit detecting entanglement in many-body systems using scanning tunneling microscopy and angle-resolved photoemission spectroscopy, two spectroscopies that measure the single-particle Green’s function. It offers the prospect of the experimental detection of entanglement through spectroscopies beyond the established route of measuring the dynamical spin response.
The procedures, performance, and results obtained from the M-52 spray booth qualification test are documented. The test was conducted at Thiokol Corporation, Space Operations, M-52 Inert Parts Preparation facility. The purpose of this testing sequence was to ensure the spray booth would produce flight qualified hardware. The testing sequence was conducted in two series. The first series was conducted under CTP-0142, Revision 1. The second series was conducted in accordance with CTP-0142, Revision 2. The test sequence started with CTP-0142, Revision 1. The series consisted of the contamination removal test and the performance test. The contamination removal test was used to assess the Teflon level in the spray booth. The performance test consisted of painting and Chemloking a forward dome inside the spray booth per flight procedures. During the performance test, two sets of witness panels (case/insulation and steel/epoxy/steel) were prepared and pull tested. The CTP-0142, Revision 2, series of testing consisted of re-testing the steel/epoxy/steel witness panels. The pull tests analysis indicates the results of the tensile tests were comparable to the systems tunnel witness panel database. The exposed panel set and the control panel set average tensile values were above the 1-basis lower limits established on the systems tunnel witness panel database. It is recommended that the M-52 spray booth be qualified for producing flight hardware.
Presented herein are the known elements of the timeline for synchrotron reflectance calibrations of HRMA witness samples (Section 2). In Section 3, lists of measurements to be done on each witness flat are developed. The elements are then arranged into timelines for the three beamlines we expect to employ in covering the full 50-12,000 eV energy range (Section 4). Although the required AXAF operational range is only 0.1-10 keV, we must calibrate the extent to which radiation just outside this band may contaminate our in-band response. In Section 5, we describe the working relationships which exist with each of the beamlines, and estimate the time available for AXAF measurements on each. From the timelines and the available time, we calculate the number of flats which could be measured in full detail over the duration of the program for each beamline. A suggestion is made regarding a minimum required baselines of witness flats from each element coating run or qualification run to be used in the calibration. We intend that this suggestion open discussion of the issue of witness flat deployment.
In ongoing investigations to map and archive the microbial footprints in various components of the spacecraft and its accessories, we have examined the microbial populations of the Jet Propulsion Laboratory's Spacecraft Assembly Facility (JPL-SAF). Witness plates made up of spacecraft materials, some painted with spacecraft qualified paints, were exposed for approximately 7 to 9 months at JPL-SAF and examined the particulate materials collected for the incidence of total cultivable aerobic heterotrophs and heat-tolerant (80 degrees C for 15-min.) spore-formers. The results showed that the witness plates coated with spacecraft qualified paints attracted more dust particles than the non-coated stainless steel witness plates. Among the four paints tested, witness plates coated with NS43G accumulated the highest number of particles, and hence attracted more cultivable microbes. The conventional microbiological examination revealed that the JPL-SAF harbors mainly Gram-positive microbes and mostly spore-forming Bacillus species. Most of the isolated microbes were heat resistant to 80 degrees C and proliferate at 60 degrees C. The phylogenetic relationships among 23 cultivable heat-tolerant microbes were examined using a battery of morphological, physiological, molecular and chemotaxonomic characterizations. By 16S rDNA sequence analysis, the isolates fell into seven clades: Bacillus licheniformis, B. pumilus, B. cereus, B. circulans, Staphylococcus capitis, Planococcus sp. and Micrococcus lylae. In contrast to the cultivable approach, direct DNA isolation, cloning and 16S rDNA sequencing analysis revealed equal representation of both Gram-positive and Gram-negative microorganisms.