Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WELLHEADS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

121 records · Page 7

Wilson Corners, Solid Waste Management Unit 001(SWMU 01) 2023 Annual Long-Term Monitoring Report

This report presents a summary of the long-term monitoring (LTM) activities that occurred in 2023 at Wilson Corners, Solid Waste Management Unit 001, at Kennedy Space Center (KSC), Florida. Annual LTM of groundwater is being conducted at the site. Based on results from groundwater sampling activities performed during the 2019 through 2020 LTM reporting period and the 2020 and 2021 DPT groundwater sampling, it was determined that the LTM sampling plan was no longer meeting the goal of LTM because delineation was not verified and the installation of an air sparge (AS) system to treat the area of the High Concentration Plume was recommended. The AS System was installed in late 2022 and early 2023. System start-up activities were initiated in April 2023. Following system startup, several site wells required retrofitting to equip wellheads for withstanding the air pressure released from air sparge wells during system operation. Some site wells also required repair or abandonment, and replacement. Survey of location and top-of-casing of newly installed monitoring wells was combined with scheduled AS system survey activities and was completed in January 2024. The activities presented in this report include the February and April 2023 LTM monitoring well installations; March and April 2023 LTM and performance monitoring well water level gauging and sampling; November 2023 LTM well retrofits and repairs; a summary of December 2023 LTM well abandonments and installations (complete site well abandonment activities will be presented under a separate cover); and January 2024 LTM well survey. During the March and April 2023 sampling events, the low-flow sampling method was used, and samples were analyzed for a select list of volatile organic compounds. In March 2023, groundwater flow for the site was generally to the west was generally consistent with historical observations at the site. The Low Concentration Plume (LCP) continues to extend both horizontally and vertically beyond the terminal depth of the current monitoring well network. Data, inclusive of the 2023 LTM and baseline performance monitoring sampling events, indicate that the LCP encompasses an estimated 19.5 acres, compared to the 2021 LCP footprint, inclusive of the 2020 and 2021 DPT sampling events of 20.7 acres. The vertical extent of VOCs was historically delineated by monitoring wells screened greater than 48 feet below land surface (bls). The results from the three vertical extent monitoring wells screened below 48 feet bls that were sampled during the 2023 LTM indicate that groundwater vinyl chloride concentrations in these three wells are greater than the GCTL. As presented in the 2021 Long-Term Monitoring Report (NASA 2022), the KSCRT agreed to delay deeper investigations in this area to prevent the creation of additional pathways for vertical migration. Based on groundwater sampling activities performed in 2023, recommendations are to perform the next annual LTM sampling event, scheduled for April 2024 and to conduct quarterly performance monitoring of the AS System. The current selection of monitoring wells in the recommended 2024 LTM plan will provide an adequate data set for monitoring groundwater plume behavior; however, the LTM monitoring well network will be evaluated and refined based on 2024 LTM and year one performance monitoring data.

King Linnea↗

New insights into microbial responses to oil spills from the Deepwater Horizon incident

On April 20, 2010, a catastrophic eruption of methane caused the Deepwater Horizon exploratory drill rig drilling the Macondo Well in Mississippi Canyon Block 252 (MC252) to explode. The Deepwater Horizon oil spill was unprecendeted for several reasons: the volume of oil released; the spill duration; the well depth; the distance from the shore-line (77 km or about 50 miles); the type of oil (light crude); and the injection of dispersant directly at the wellhead. This study clearly demonstrated that there was a profound and significant response by certain members of the in situ microbial community in the deep-sea in the Gulf of Mexico. In particular putative hydrocarbon degrading Bacteria appeared to bloom in response to the Deepwater Horizon oil spill, even though the temperature at these depths is never >5 C. As the plume aged the shifts in the microbial community on a temporal scale suggested that different, yet metabolically important members of the community were able to respond to a myriad of plume constituents, e.g. shifting from propane/ethane to alkanes and finally to methane. Thus, the biodegradation of hydrocarbons in the plume by Bacteria was a highly significant process in the natural attenuation of many compounds released during the Deepwater Horizon oil spill.

02 PETROLEUM↗

Fuel-Flexible, Low-Emissions Catalytic Combustor for Opportunity Fuels

Precision Combustion, Inc. will develop a unique, fuel-flexible Rich Catalytic Lean-Burn (RCL®) injector with catalytic combustor capable of enabling ultralow-emission, lean premixed combustion of a wide range of gaseous opportunity fuels. This will broaden the range of opportunity fuels that can be utilized to include low- and ultralow-Btu gases, such as digester and blast furnace gases, and fuels containing reactive species, such as refinery, wellhead, and industrial byproduct gases.

Catalytic Combustor↗

Bringing Fenton Hill into the Digital Age: Data Conversion in Support of the Geothermal Technologies Office Code Comparison Study Challenge Problems

The Geothermal Technologies Office Code Comparison Study (GTO-CCS) was established by the U.S. Department of Energy to facilitate collaboration among members of the geothermal modeling community and to evaluate and improve upon the ability of existing codes to simulate thermal, hydrological, mechanical, and chemical processes associated with complex enhanced geothermal systems (EGS). The first stage of the project, which has been completed, involved comparing simulations for seven benchmark problems that were primarily designed using well-prescribed, simplified data sets. In the second stage, the participating teams are tackling two challenge problems based on the EGS research conducted in hot dry rock (HDR) at Fenton Hill, near Los Alamos, New Mexico. The Fenton Hill project, conducted by Los Alamos National Laboratory (LANL) from 1970 to 1995, was the world’s first HDR demonstration project. One of the criteria for selecting this experiment as the basis for the challenge problems was the amount and availability of data for generating model inputs. The Fenton Hill HDR system consisted of two reservoirs – an earlier Phase I reservoir tested from 1974 to 1981 and a deeper Phase II reservoir tested from 1980 to 1995. Detailed accounts of both phases of the HDR project have been presented in a number of books and reports, including a recently published summary of the lessons learned and a final report with a chronological description of the Fenton Hill project, prepared by LANL. Project documents and records have been archived and made public through the National Geothermal Data System (NGDS). Some of the data acquired from Phase II are available in electronic format readable on modern computers. These include the microseismic data from some of the important experiments (e.g. the massive hydraulic fracturing test conducted in 1983) and the injection/production wellhead data from the circulation tests conducted between 1992-1995. However, much of the data collected during the project, while publicly available, currently only exist in the form of tables or graphs within scanned documents. Therefore, in support of the GTO-CCS, the data needed for developing simulation inputs are being compiled and converted to platform independent, open readable formats so that all participating teams will have access to the same electronic data set. In some cases this requires conversion using optical character recognition, digitizing existing images, and generating the appropriate metadata from project documents. The GTO-Velo knowledge management framework, developed by Pacific Northwest National Laboratory (PNNL), was used for the benchmark problem stage of the comparison study and will also be used as the data repository for the challenge problem data sets. It is staggering and impractical to convert all published data for the Fenton Hill site, so the focus is on data that supports simulations for the three topical areas defined by the study for the challenge problems: 1) reservoir creation/stimulation, 2) reactive and passive transport, and 3) thermal recovery. Conversion of these data provide value not only to GTO-CCS participants, but also to members of the geothermal community at large who may be interested in revisiting the Fenton Hill experiment in the future.

Code Comparison Study↗

Challenges in Implementing a Multi-Partnership Geothermal Power Plant

The UND-CLR binary geothermal power plant project is a piggyback operation on a secondary-recovery water-flood project in the Cedar Hills oil field in the Williston Basin. Two open-hole horizontal wells at 2,300 m and 2,400 m depths with lateral lengths of 1,290 m and 860 m produce water at a combined flow of 51 l s -1 from the Lodgepole formation (Miss.) for injection into the Red River formation (Ordovician). The hydrostatic head for the Lodgepole is at ground surface and the pumps, which are set at 650 m depth, have run continuously since 2009. Water temperature at the wellhead is 103 °C and CLR passes the water through two large air-cooled heat exchangers prior to injection. In all aspects, the CLR water flood project is ideal for demonstration of electrical power production from a low-temperature geothermal resource. However, implementation of the project from concept to power production was analogous to breaking trail in deep snow in an old growth forest. There were many hidden bumps, detours, and in some instances immoveable barriers. Problems with investors, cost share, contracts with CLR, resistance from local industry, cost of installation, delays by the ORC supplier, and the North Dakota climate all caused delays and setbacks. Determination and problem solving by the UND team eventually overcame most setbacks, and in April 2016, the site began generating power. Figure 1: Schematic of the water supply well at the UND CLR binary geothermal power plant REFERENCES Williams, Snyder, and Gosnold, 2016, Low Temperature Projects Evaluation and Lesson Learned, GRC Transactions, Vol. 40, 203-210 Gosnold, LeFever, Klenner, Mann, Salehfar, and Johnson, 2010, Geothermal Power from Coproduced Fluids in the Williston Basin, GRC Transactions, Vol. 34, 557-560

Coproduced, geothermal, binary power↗

Development of a CO 2 Chemical Sensor for Downhole CO 2 Monitoring in Carbon Sequestration

Geologic storage of carbon dioxide (CO 2 ) has been proposed as a viable means for reducing anthropogenic CO 2 emissions. The means for geological sequestration of CO 2 is injection of supercritical CO 2 underground, which requires the CO 2 to remain either supercritical, or in solution in the water/brine present in the underground formation. However, there are aspects of geologic sequestration that need further study, particularly in regards to safety. To date, none of the geologic sequestration locations have been tested for storage integrity under the changing stress conditions that apply to the sequestration of very large amounts of CO 2 . Establishing environmental safety and addressing public concerns require widespread monitoring of the process in the deep subsurface. In addition, studies of subsurface carbon sequestration such as flow simulations, models of underground reactions and transports require a comprehensive monitoring process to accurately characterize and understand the storage process. Real-time information about underground CO 2 movement and concentration change is highly helpful for: (1) better understanding the uncertainties present in CO 2 geologic storage; (2) improvement of simulation models; and (3) evaluation of the feasibility of geologic CO 2 storage. Current methods to monitor underground CO 2 storage include seismic, geoelectric, isotope and tracer methods, and fluid sampling analysis. However, these methods commonly resulted low resolution, high cost, and the inability to monitor continuously over the long time scales of the CO 2 storage process. A preferred way of monitoring in-situ underground CO 2 migration is to continuous measure CO 2 concentration change in brine during the carbon storage process. An approach to obtain the real time information on CO 2 concentration change in formation solution is highly demanded in carbon storage to understand the CO 2 migration subsurface and to answer the public safety problem. The objective of the study is to develop a downhole CO 2 sensor that can in-situ, continuously monitor CO 2 concentration change in deep saline. The sensor is a Severinghaus-type CO 2 sensor with small size, which renders it can be embedded in monitoring well casing or integrated with pressure/temperature transducers, enabling the development of “smart” wells. The studies included: (1) prepare and characterize metal-oxide electrodes. Test the electrodes response to pH change. Investigate different ions and brine concentration effects on the electrode’s performance. Study the stability of the electrode in brine solution; (2) fabricate a downhole CO 2 sensor with the metal-oxide electrodes prepared in the laboratory. Test the performance of the CO 2 sensor in brine solutions. Study high pressure effects on the performance of the sensor; (3) design and conduct CO 2 /brine coreflooding experiments with the CO2 sensor. Monitor CO 2 movement along the core and test the performance of the sensor in coreflooding tests. Develop a data acquisition system that can digitize the sensor’s output voltage. Our completed research has resulted in deep understanding of downhole CO 2 sensor development and CO 2 monitoring in CO 2 storage process. The developed downhole CO 2 sensor included a metal-oxide electrode, a gas-permeable membrane, a porous steel cup, and a bicarbonate-based internal electrolyte solution. Iridium oxide-based electrode was prepared and used for preparation the CO 2 sensor. The prepared iridium oxide-based electrode displayed a linearly response to pH change. Different factors such as different ions and ions concentration, temperature, and pressure effects on the electrode performance on pH response were investigated. The results indicated that the electrode exhibited a good performance even in high salt concentration of produced water. To improve the electrode performance under high pressure, IrO 2 nanoparticles with the particle size in the range of 1-2 nm were prepared and electrodeposited on stainless steel substrate by cyclic voltammetry. It was observed that the thin film of iridium oxide was formed on the substrate surface and such iridium oxide-based electrode displayed excellent performance under high pressure for longer term. A downhole CO 2 sensor with the iridium oxide-based electrode was prepared. The working principle of the CO 2 sensor is based on the measurement of the pH change of the internal electrolyte solution caused by the hydrolysis of CO 2 and then determination of the CO 2 concentration in water. The prepared downhole CO 2 sensor had the size of diameter of 0.7 in. and length of 1.5 in. The sensor was tested under the pressures of 500 psi, 2,000 psi, and 3,000 psi. A linear correlation was observed between the sensor potential change and dissolved CO 2 concentration in water. The response time of the CO 2 sensor was in the range of 60-100 minutes. Further tests indicated that the CO 2 sensor exhibited good reproducibility under high pressure. A CO 2 /brine coreflooding system was constructed to simulate the real-world CO 2 storage process. The prepared downhole CO 2 sensor was loaded in the system to monitor CO 2 movement during CO 2 /brine coreflooding test. The results indicated that the sensor could detect CO 2 movement in the tests. Further studies showed that the sensor could be recovered by brine flooding after CO 2 /brine flushed the core. The results of the coreflooding tests demonstrated that the sensor had potential application for CO 2 monitoring in carbon sequestration. A data acquisition system for the downhoe CO 2 sensor was developed and coded. The system converted the sensor output signal into digital data and transported the data from downhole to wellhead surface. The data acquisition system was tested and evaluated in the laboratory with the prepared sensor for data collection.

36 MATERIALS SCIENCE↗

Kick detection systems and methods

An apparatus for detecting potential kicks in a well is provided. In one embodiment, the apparatus includes a drill string positioned in a well, a mud circulation system coupled to supply drilling mud to the drill string, and a mud analyzer. The mud analyzer includes a sensor that is positioned along a drilling mud return path closer to a wellhead assembly installed at the well than to a mud tank of the mud circulation system, and the mud analyzer enables identification of a potential formation kick based on data acquired by the sensor. Additional systems, devices, and methods are also disclosed.

Gottlieb, Emanuel J.↗

Modeling Natural Gas Production Water Burdens - ISSST2018

This work was presented at the International Symposium on Sustainable Systems and Transportation (ISSST) 2018 Conference in Buffalo, NY on June 27, 2018. A deeper characterization of wellhead water consumption and discharge was conducted to allow for broader impact assessment. Water use for well stimulation accounts for both volume and source (surface, ground, brackish, recycled). Water quality includes inventory items such as total dissolved solids (TDS), chlorine, iron, and sulfur, many of which are elemental flows in TRACI impact categories. Disposal of produced water includes methods such as recycling for reuse, deep well injection, and centralized treatment plants. Data are organized by production basins and extraction technologies, for a total of 27 unique scenarios. These combinations of basins and technologies represent 95% of 2016 onshore U.S. natural gas production.

Skone, Timothy J.↗

Numerical Simulation of Critical Factors Controlling Heat Extraction from Geothermal Systems Using a Closed-Loop Heat Exchange Method

Closed-loop heat exchange for geothermal energy production involves injecting working fluid down a well that extends through the geothermal resource over a significant length to absorb heat by conduction through the well pipe. The well then needs to return to the surface for energy recovery and fluid re-injection to complete the cycle. We have carried out mixed convective-conductive fluid-flow modeling using a wellbore flow model for TOUGH2 called T2Well to investigate the critical factors that control closed-loop geothermal energy recovery. T2Well solves a mixed explicit-implicit set of momentum equations for flow in the pipe with full coupling to the implicit three-dimensional integral finite difference equations for Darcy flow in the porous medium. T2Well has the option of modeling conductive heat flow from the porous medium to the pipe by means of a semi-analytical solution which makes the computation very efficient because the porous medium does not have to be discretized. When the fully three-dimensional option is chosen, the porous medium is discretized and heat flow to the pipe is by conduction and convection, depending on reservoir permeability and other factors. Simulations of the closed-loop system for a variety of parameter values have been carried out to elucidate the heat recovery process. To the extent that convection may occur to aid in heat delivery to the pipe, the permeability of the geothermal reservoir, whether natural or stimulated, is an important property in heat extraction. The injection temperature and flow rate of the working fluid strongly control the ultimate energy recovery. Pipe diameter also plays a strong role in heat extraction, but is correlated with flow rate. Similarly, the choice of working fluid plays an important role, with water showing better heat extraction than CO2 for certain flow rates, while the CO2 has higher pressure at the production wellhead which can aid in surface energy recovery. In general, we find complex interactions between the critical factors that will require advanced computational approaches to fully optimize.

Oldenburg, Curtis↗

Hydraulic and Thermal Stimulation Program at Raft River Idaho, A DOE EGS

A Department of Energy Enhanced Geothermal System (EGS) stimulation program has injected over 254 million gallons of water into the well RRG-9 ST1 since the summer of 2013. Three major stimulations have been conducted during the program increasing injection flow rates from less than 20 gpm to 550 gpm. Geologic, water chemistry, microseismic activity, and borehole imaging data have been used to develop a conceptual model describing possible flow paths of this injected water. This model contains two major fracture zones one of which intersects the RRG-9 ST1 wellbore. Modified Hall and injectivity index plots constructed using injection flow rates, surface temperatures, and wellhead pressures show steady improvement in the injectivity of the well. Here, the injectivity index has risen from 0.15 gpm/psi to 2.0 gpm/ psi. A pressure falloff test conducted on April 28, 2015 indicates a reservoir permeability of 1,220 md and -5.38 skin factor. The well stimulation program was simulated numerically using an Idaho National Laboratory reservoir simulation code, FALCON. These simulations show a significant increase in the permeability of connecting fracture pathways after each stimulation event.

Enhanced geothermal system↗

Recent Developments at the Raft River Geothermal Field

The Raft River geothermal field, located in Cassia County in southwestern Idaho, is the site of a Department of Energy Enhanced Geothermal System project. U.S. Geothermal, Inc. currently produces about 11 MWe from Precambrian metamorphic rocks. These lie beneath ~5,000 ft of Quaternary and Tertiary volcaniclastic and volcanic deposits. Maximum temperatures range from 271°F to 300°F. Well RRG-9 ST1, the well targeted for stimulation is located approximately 1 mile south of the main bore field. The open hole section of the well, from 5,551 to 5,900 ft MD, consists of Precambrian Elba Quartzite, the stimulation target, granite and minor diabase. Prior to setting the casing acoustic, gamma ray, and density logs were run. After completing the well, a step rate/step down test was conducted. The maximum injection rate achieved was 18 bpm at a wellhead pressure of 1,150 psig. A borehole televiewer run in the open hole section showed evidence of more than eighty fractures. The majority of these fractures trend from N20⁰W to N20°E and dip from 40° to 60°W. Permeable fractures were encountered in the Elba Quartzite at 5,640-5,660 ft MD. Analysis of the injection test indicates that the minimum in-situ principal stress in this zone is 3,050-3,200 psi, corresponding to a fracture gradient of 0.59-0.62 psi/ft. A discrete fracture network model was developed using measured and inferred fracture orientations, distributions and dimensions. A three-phase stimulation program is proposed for RRG-9 ST-1. During the first two stages, water at 140°F, and later 40°F, will be injected to pre-condition and thermally fracture the reservoir. Here, the third stage will consist of a high rate, large volume conventional hydraulic stimulation.

Bradford, Jacob↗

Wellbore integrity assessment with casing-based advanced sensing

Wellbore integrity is of paramount importance to subsurface resource extraction, energy storage 1 and waste disposal. After installation, well casing and cement are subject to mechanical stress due to near-well pressure changes and fluid induced corrosion. This is exacerbated for geothermal wells where produced fluid is at high temperature and corrosive. The current state-of-the-art technologies for wellbore integrity assessments are an array of cased hole logging tools. Wireline deployed acoustic, electromagnetic and mechanical tools are all available to inspect steel casing corrosion and casing-cement bond and these tools can provide high-resolution assessment of borehole conditions. They are intrusive, however, in terms of borehole preparation and interruption to the normal operation of the wells, and not suitable for high temperature or highly deviated well deployments. In addition, these measurements are performed infrequently due to high cost, and are therefore incapable of providing frequent data to better predict borehole degradation trajectory, which can help provide early warning of potential borehole failures. For this project we are developing a suite of novel, non-invasive, casing based tools for wellbore integrity assessment, combining fast/low cost screening with higher-precision investigation. Our approach is based on monitoring the response of the casing when energized at the wellhead, thereby interrogating the casing without well intervention. Lab, field and numerical approaches are used in our study. During the early stage of the research, we focus on numerical simulations, which have shown the sensitivity of the low frequency electromagnetic (EM) signals to changes in borehole depths and have successfully tested the concept at a field site with different length well casings. Initial seismic modeling efforts have also demonstrated our capability to simulate seismic tube wave and seismic field alterations due to borehole breakage and associated fluid leakage. Further numerical, laboratory and field experiments are underway for additional technology sensitivity analysis, particularly the transient EM/Seismic reflectometry methods, data acquisition optimization, and numerical simulation improvements.

Wilt, Michael↗

SECARB Construction and Site Info

Site information, well schematics, component diagrams, and casing tally from the SECARB project at Cranfield oil site in Mississippi.

as built↗