Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Laser velocimetry with diode junctions semiconductor lasers

Measurements of mean and fluctuating axial velocity have for the first time been made in a seeded pipe flow with a semiconductor laser velocimeter. Several compact velocimeters have been constructed using laser diodes. While the intended applications have restricted the final instrument to operate in a coaxial backscatter mode, operation has been demonstrated in forward and side scattering modes. In all cases the instrument could be classed as dual beam. An instrument has been constructed to be installed in a model airfoil and will be mechanically driven to measure the flow over a 75-mm chord distance. The instrument occupies a volume measuring 100 mm x 100 mm x 40 mm. The compactness has been aided by using an avalanche photodiode instead of a photomultiplier tube.

Franke, J. M.↗

Development of the NASA High-Altitude Imaging Wind and Rain Airborne Profiler

The scope of this paper is the development and recent field deployments of the High-Altitude Imaging Wind and Rain Airborne Profiler (HIWRAP), which was funded under the NASA Instrument Incubator Program (IIP) [1]. HIWRAP is a dual-frequency (Ka- and Ku-band), dual-beam (300 and 400 incidence angles), conical scanning, Doppler radar system designed for operation on the NASA high-altitude (65,000 ft) Global Hawk Unmanned Aerial System (UAS). It utilizes solid state transmitters along with a novel pulse compression scheme that results in a system with compact size, light weight, less power consumption, and low cost compared to radars currently in use for precipitation and Doppler wind measurements. By combining measurements at Ku- and Ka-band, HIWRAP is able to image winds through measuring volume backscattering from clouds and precipitation. In addition, HIWRAP is also capable of measuring surface winds in an approach similar to SeaWinds on QuikScat. To this end, HIWRAP hardware and software development has been completed. It was installed on the NASA WB57 for instrument test flights in March, 2010 and then deployed on the NASA Global Hawk for supporting the Genesis and Rapid Intensification Processes (GRIP) field campaign in August-September, 2010. This paper describes the scientific motivations of the development of HIWRAP as well as system hardware, aircraft integration and flight missions. Preliminary data from GRIP science flights is also presented.

Li, Lihua↗

Experimental investigation of the influence of drainage condition on change in saturation of sheared sand

Here, this paper investigates the validity of the interpretation of results from testing saturated axisymmetric triaxial compression (ATC) sand specimens utilising three-dimensional (3D) synchrotron micro-computed tomography (SMT) to probe localised events that are completely missed or misinterpreted when analysing ATC measurements based on global standard measurements. Drained and undrained experiments were conducted at low and high back-pressures (BPs) coupled with multiple in situ 3D SMT to acquire high-resolution scans of the specimens at different axial strains. Specimens tested under low BP exhibited a large pore air volume change, which was not detected by the pump system that represents standard volume measurement. The increase in air volume caused a significant reduction in the degree of saturation leading to a possible transition from saturated to partially saturated constitutive behaviour. Undrained experiments exhibited a significant volume change contrary to the assumption of negligible volumetric strain for saturated undrained experiments. Air bubbles within the shear band for drained and undrained low-BP specimens showed opposite capillary pressure responses, increased for drained and decreased for undrained cases, due to the variation in the mechanism by which each of the two experiments predominantly counters the volume expansion within the shear band.

capillary pressure↗

Accurate measurement of gas volumes by liquid displacement

Mariotte bottle as liquid displacement device was used to measure gas volumes at flow rates that are far below threshold of wet test gas meters. Study of factors affecting amount of liquid displaced by gas flow was completed, and equations were derived which relate different variables.

Christian, J. D.↗

Three Component Velocity and Acceleration Measurement Using FLEET

The femtosecond laser electronic excitation and tagging (FLEET) method has been used to measure three components of velocity and acceleration for the first time. A jet of pure N2 issuing into atmospheric pressure air was probed by the FLEET system. The femtosecond laser was focused down to a point to create a small measurement volume in the flow. The long-lived lifetime of this fluorescence was used to measure the location of the tagged particles at different times. Simultaneous images of the flow were taken from two orthogonal views using a mirror assembly and a single intensified CCD camera, allowing two components of velocity to be measured in each view. These different velocity components were combined to determine three orthogonal velocity components. The differences between subsequent velocity components could be used to measure the acceleration. Velocity accuracy and precision were roughly estimated to be +/-4 m/s and +/-10 m/s respectively. These errors were small compared to the approx. 100 m/s velocity of the subsonic jet studied.

Danehy, Paul M.↗

Investigating the clinico-anatomical dissociation in the behavioral variant of Alzheimer disease

We previously found temporoparietal-predominant atrophy patterns in the behavioral variant of Alzheimer’s disease (bvAD), with relative sparing of frontal regions. Here, we aimed to understand the clinico-anatomical dissociation in bvAD based on alternative neuroimaging markers. We retrospectively included 150 participants, including 29 bvAD, 28 “typical” amnestic-predominant AD (tAD), 28 behavioral variant of frontotemporal dementia (bvFTD), and 65 cognitively normal participants. Patients with bvAD were compared with other diagnostic groups on glucose metabolism and metabolic connectivity measured by [ 18 F]FDG-PET, and on subcortical gray matter and white matter hyperintensity (WMH) volumes measured by MRI. A receiver-operating-characteristic-analysis was performed to determine the neuroimaging measures with highest diagnostic accuracy. bvAD and tAD showed predominant temporoparietal hypometabolism compared to controls, and did not differ in direct contrasts. However, overlaying statistical maps from contrasts between patients and controls revealed broader frontoinsular hypometabolism in bvAD than tAD, partially overlapping with bvFTD. bvAD showed greater anterior default mode network (DMN) involvement than tAD, mimicking bvFTD, and reduced connectivity of the posterior cingulate cortex with prefrontal regions. Analyses of WMH and subcortical volume showed closer resemblance of bvAD to tAD than to bvFTD, and larger amygdalar volumes in bvAD than tAD respectively. The top-3 discriminators for bvAD vs. bvFTD were FDG posterior-DMN-ratios (bvAD bvFTD, area under the curve [AUC] range 0.85–0.91, all p < 0.001). The top-3 for bvAD vs. tAD were amygdalar volume (bvAD>tAD), MRI anterior-DMN-ratios (bvAD<tAD), FDG anterior-DMN-ratios (bvAD<tAD, AUC range 0.71–0.84, all p < 0.05). Subtle frontoinsular hypometabolism and anterior DMN involvement may underlie the prominent behavioral phenotype in bvAD.

59 BASIC BIOLOGICAL SCIENCES↗

Instrument for Measuring Engine Clearance Volumes

With the advent of the V type engine, a new method to measure the clearance volume in cylinders was needed. It was suggested that this measurement could be made by a process which consisted essentially of simultaneously changing both a known and unknown volume of gas by a known amount and then calculating the magnitude of the unknown from the resulting difference in pressure between the two. An instrument based on this design is described.

Sparrow, S W↗

L2F and LDV velocimetry measurement and analysis of the 3-D flow field in a centrifugal compressor

The flow field in the Purdue Research Centrifugal Compressor is studied using a laser two-focus (L2F) velocimeter. L2F data are obtained which quantify: (1) the compressor inlet flow field; (2) the steady-state velocity field in the impeller blade passages; and (3) the flow field in the radial diffuser. The L2F data are compared with both laser Doppler velocimetry (LDV) data and predictions from three-dimensional inviscid and viscous flow models. In addition, a model is developed to calculate the effect on the measurement volume geometry of refraction by curved windows. Finally, the advantages and disadvantages of using the L2F for turbomachinery measurements is discussed in terms of measurement accuracy, ease of use, including sample time per correlated event and the ability to make measurements in regions of high noise due to stray radiation from wall reflections.

Fagan, John R., Jr.↗

Fire Safety Implications of Preliminary Results from Saffire IV and V Experiments on Large Scale Spacecraft Fires

The spread and growth of flames over large solid fuel samples and their effect on the pressurized spacecraft were studied inside the Cygnus spacecraft while in orbit after departing the International Space Station. These experiments were developed by NASA’s Advanced Exploration Systems Division in the Human Exploration and Operations Mission Directorate. The ignited materials consisted of poly-methyl methacrylate (PMMA), cotton fabric and a cotton/fiberglass fabric blend. The samples were all 40 cm wide and with various lengths ranging from 18 cm for the PMMA samples to 50 cm for the fabrics. The overall results from these tests and their impact on the spacecraft are presented with emphasis on the fire safety implications of the results. The experiments included, a post-fire cleanup system, vehicle internal volume measurements, and transport of acid gases (HCl and HF). Measurements included video images, flame spread rate, flame temperatures and radiant heat output; energy release through oxygen calorimetry; distributed measurements of CO2 concentration and temperature at six locations in the spacecraft; CO2, CO, O2, HF and HCl concentrations; vehicle pressurized volume; and aerosol concentrations. Details of the flame growth and spread are discussed in other papers as are details of the post-fire cleanup system performance. The fire events had a measurable impact on the vehicle pressure, temperature, and carbon dioxide concentration. However, despite having heat release rates up to 10 kW, the average vehicle conditions did not rise to unacceptable levels. The combined results of the experiments provide significant new understanding of the impact of sample and flow duct height on flame spread and growth in addition to an improved perspective of the impact of a fire event on a spacecraft.

micorgravity↗

Fire Safety Implications of Preliminary Results from Saffire IV and V Experiments on Large Scale Spacecraft Fires

The spread and growth of flames over large solid fuel samples and their effect on the pressurized spacecraft were studied inside the Cygnus spacecraft while in orbit after departing the International Space Station. These experiments were developed by NASA’s Advanced Exploration Systems Division in the Human Exploration and Operations Mission Directorate. The ignited materials consisted of poly-methyl methacrylate (PMMA), cotton fabric and a cotton/fiberglass fabric blend. The samples were all 40 cm wide and with various lengths ranging from 18 cm for the PMMA samples to 50 cm for the fabrics. The overall results from these tests and their impact on the spacecraft are presented with emphasis on the fire safety implications of the results. The experiments included, a post-fire cleanup system, vehicle internal volume measurements, and transport of acid gases (HCl and HF). Measurements included video images, flame spread rate, flame temperatures and radiant heat output; energy release through oxygen calorimetry; distributed measurements of CO2 concentration and temperature at six locations in the spacecraft; CO2, CO, O2, HF and HCl concentrations; vehicle pressurized volume; and aerosol concentrations. Details of the flame growth and spread are discussed in other papers as are details of the post-fire cleanup system performance. The fire events had a measurable impact on the vehicle pressure, temperature, and carbon dioxide concentration. However, despite having heat release rates up to 10 kW, the average vehicle conditions did not rise to unacceptable levels. The combined results of the experiments provide significant new understanding of the impact of sample and flow duct height on flame spread and growth in addition to an improved perspective of the impact of a fire event on a spacecraft.

microgravity fire safety↗

Noninvasive Intracranial Volume and Pressure Measurements Using Ultrasound

Prevention of secondary brain injuries following head can be accomplished most easily when intracranial pressure (ICP) is monitored. However, current measurement techniques are invasive and thus not practical in the combat environment. The Pulsed Phase Lock Loop (PPLL) devise, which was developed and patented, uses a unique, noninvasive ultrasonic phase comparison method to measure slight changes in cranial volume which occur with changes in ICP. Year one studies involved instrument improvements and measurement of altered intracranial distance with altered ICP in fresh cadavera. Our software was improved to facilitate future studies of normal subjects and trauma patients. Our bench studies proved that PPLL output correlated highly with changes in path length across a model cranium. Cadaveric studies demonstrated excellent compact, noninvasive devise for monitoring changes in intracranial distance may aid in the early detection of elevated ICP, decreasing risk of secondary brain injury and infection, and returning head-injured patients to duty.

Hargens, A. R.↗

A fundamental problem in determining functional residual capacity or residual volume

To measure a lung volume that is not directly accessible, one often follows dilution of a single-gas tracer, present initially only in the lung or in a rebreathing bag. The final volume available to the tracer is assumed to be the sum of the two initial components. Since O2 is taken up and CO2 is eliminated during the few breaths required for mixing, the total volume changes. The error in lung volume due to this volume change can exceed 10 pct. Theoretical and experimental data is presented to demonstrate the effect of CO2 and O2 exchange. A general equation, based on N2 and Ar, which allows one to circumvent the problems created by these fluxes is introduced. The pitfall of the back-extrapolation approach for a single tracer is shown.

Boutellier, U.↗

Analysis of changes in leg volume parameters, and orthostatic tolerance in response to lower body negative pressure during 28-days exposure to zero gravity Skylab 2

The design of the leg volume measuring system employed for the M092 portion of the Skylab missions required the development of a system sensitive to large and small volume changes at the calf of the leg. These changes in volume were produced in response to the orthostatic stress of a Lower Body Negative Pressure Device (LBNPD) or by venous occlusion. The cardiovascular responses of the Apollo crewman associated with the postflight evaluations indicate varying decrements of orthostatic tolerance. The postflight changes indicate a slightly diminished ability of the cardiovascular system to function effectively against gravity following exposure to weightlessness. The objective of the Skylab LBNP experiments (M092) was to provide information about the magnitude and time course of the cardiovascular changes associated with prolonged periods of exposure to weightlessness. The equipment, signal processing, and analysis of the leg volume data obtained from the M092 experiment of the Skylab 2 Mission are described.

Barnett, R. D.↗

Compressibility measurement of fluid-system ullage

Portable self-contained instrument measures volume of free gas or air trapped in closed fluid systems, such as lubricating-oil lines or hydraulic brakes. In response to measurement readings, operator may use device to accurately add or withdraw fluid to or from system.

Dzienis, D. A.↗

Volume Ice Radiolysis in the Outer Solar System

The primary energy flux of charged particle components of the heliospheric and magnetospheric environments of the solar system is primarily carried by highly penetrating energetic particles. Although laboratory experiments on production of organics and oxidants typically only address effects on very thin surface layers, energy deposition occurs on surfaces of icy bodies of the outer solar system to meters in depth. Time scales for significant radiolytic deposition vary from thousands of years at millimeter depths on Europa to billions of years in the meters-deep regolith of Kuiper Belt Objects. Radioisotope decay (e.g., K-40) also contributes to volume radiolysis as the only energy source at much greater depths. Radiolytic oxygen is a potential resource for life within Europa and a partial source of oxygen for Saturn's magnetosphere and Titan's upper atmosphere. Interactions of very high energy cosmic rays with ices at Titan's surface may provide one of the few sources of oxidants in that highly reducing environment. The red colors of low-inclination classical Kuiper Belt Objects at 40-50 AU, and Centaur objects originating from this same population, may arise from volume radiolysis of deep ice layers below more refractory radiation crusts eroded away by surface sputtering and micrometeoroid impacts. A variety of techniques are potentially available to measure volume radiolysis products and have been proposed for study as part of the new Space Physics of Life initiative at NASA Goddard Space Flight Center. The technique of Electron Paramagnetic Resonance (EPR) has been used in medical studies to measure oxidant production in irradiated human tissue for cancer treatment. Other potential techniques include optical absorption spectroscopy and standard wet chemical analysis. These and other potential techniques are briefly reviewed for applicability to problems in solar system ice radiolysis and astrobiology.

Cooper, John F.↗

High-fidelity retrieval from instantaneous line-of-sight returns of nacelle-mounted lidar including supervised machine learning

Abstract. Wind turbine applications that leverage nacelle-mounted Doppler lidar are hampered by several sources of uncertainty in the lidar measurement, affecting both bias and random errors. Two problems encountered especially for nacelle-mounted lidar are solid interference due to intersection of the line of sight with solid objects behind, within, or in front of the measurement volume and spectral noise due primarily to limited photon capture. These two uncertainties, especially that due to solid interference, can be reduced with high-fidelity retrieval techniques (i.e., including both quality assurance/quality control and subsequent parameter estimation). Our work compares three such techniques, including conventional thresholding, advanced filtering, and a novel application of supervised machine learning with ensemble neural networks, based on their ability to reduce uncertainty introduced by the two observed nonideal spectral features while keeping data availability high. The approach leverages data from a field experiment involving a continuous-wave (CW) SpinnerLidar from the Technical University of Denmark (DTU) that provided scans of a wide range of flows both unwaked and waked by a field turbine. Independent measurements from an adjacent meteorological tower within the sampling volume permit experimental validation of the instantaneous velocity uncertainty remaining after retrieval that stems from solid interference and strong spectral noise, which is a validation that has not been performed previously. All three methods perform similarly for non-interfered returns, but the advanced filtering and machine learning techniques perform better when solid interference is present, which allows them to produce overall standard deviations of error between 0.2 and 0.3 m s−1, or a 1 %–22 % improvement versus the conventional thresholding technique, over the rotor height for the unwaked cases. Between the two improved techniques, the advanced filtering produces 3.5 % higher overall data availability, while the machine learning offers a faster runtime (i.e., ∼ 1 s to evaluate) that is therefore more commensurate with the requirements of real-time turbine control. The retrieval techniques are described in terms of application to CW lidar, though they are also relevant to pulsed lidar. Previous work by the authors (Brown and Herges, 2020) explored a novel attempt to quantify uncertainty in the output of a high-fidelity lidar retrieval technique using simulated lidar returns; this article provides true uncertainty quantification versus independent measurement and does so for three techniques rather than one.

47 OTHER INSTRUMENTATION↗

Peripheral venous scintillation angiocardiography in determination of left ventricular volume in man.

Left ventricular end-diastolic volume was determined by cardiac visualization after peripheral venous injection of a gamma-emitting isotope in 10 patients with organic heart disease. The left ventricular end-diastolic volume measured by the isotope method consistently averaged 9% less than that determined by the X-ray method. The mean difference in left ventricular end-diastolic volume was 21 ml. Excellent correlation between the two methods was observed. It is pointed out that peripheral venous scintillation angiocardiography compares well with left ventriculography in the determination of left ventricular end-diastolic volume in man.

Sullivan, R. W.↗