Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VAR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

LIFE IN EXTRATERRESTRIAL ENVIRONMENTS

The objective of this program was to establish whether terrestrial life forms can survive and thrive in extraterrestrial environments. Other than Earth, the only solar body capable of supporting terrestrial life appears to be the planet Mars. The conditions selected to simulate a Martian environment were determined by a literature search and were: 1) Light of > 4800-A wavelength 2) Temperature changes from a diurnal high of 30 °C to a nocturnal low to -60 °C 3) Atmosphere composed of 95% nitrogen, 4% argon, 0.3% carbon dioxide, and less than 1% oxygen and moisture. The organisms tested in thesimjulated Martian environment were: 1) Algae: Trebouxia erici 2) Bacteria: Clostridium tetani, Bacillus subtilis, and Escherichia coli 3) Bryophytes: the liverwort Marchantia polymorpha; the mosses Eurhynchium strigosum, Atrichum undulatum, Mnium sp., Brium sp., Grimmia sp., Pogonatum sp., and Polytrichum sp. 4) Lichens: Cladonia conoeraea, C. rangifernia, C. cristatella, C. pyxidate, Parmelia conspersa var. isidata, P. conspersa var. leucophora, Lecidea cyanea, Umbilicaria dillenii, Physcia hypoleuca, and Ramalina sp. T. erici survived for about 2 weeks. C. tetani and E. coli cells decreased rapidly in number, but the tetanus toxin remained active for the 127=day period of the experiment. B. subtilis cells increased in number. Of the Bryophytes, only one moss survived. Complete results for the lichens are not yet available. It is suggested that the observed color changes on the Martian surface may be explained in part by color changes in the surface vegetation as a function of moisture content.

Mars (Planet)↗

Ecology and thermal inactivation of microbes in and on interplanetary space vehicle components

Data showing that 90 C was a more effective temperature than 125 C for the destruction of Bacillus subtilis var. niger when the head-space moisture was fixed at 474 micrograms H2O/ml have been confirmed and are summarized. The influence of head-space moisture at 90 C was investigated and it was observed that as the head-space moisture was increased 474 micrograms H2O/ml, there was a corresponding increase in lethality of the system. This moisture level corresponded to 100% relative humidity at 90 C, and additional water in the cans should have had no effect. A profound descrease was observed in the destruction of the organisms when additional water was added. The discontinuity observed in these data is troublesome and must be resolved as the first step in an orderly exploration of low temperature inactivation of B. subtilis var. niger.

Campbell, J. E.↗

Rolling-element fatigue life of AISI M-50 and 18-4-1 balls

Rolling element fatigue studies were conducted with AISI M-50, EFR 18-4-1, and VAR 18-4-1. Groups of 12.7 mm (1/2-in) diameter balls of each material were tested in the five ball fatigue tester. Test conditions included a load of 1540 N (347 lbf) giving a maximum Hertz stress of 5520 MPa (800 000 psi), a shaft speed of 10,700 rpm, and a contact angle of 30 deg. Tests were run at a race temperature of 339 K (150 F) with a type 2 ester lubricant. The rolling element fatigue life of AISI M-50 was not significantly different from that of EFR 18-4-1 or VAR 18-4-1 based on a statistical comparison of the test results.

Parker, R. J.↗

Rolling element fatigue testing of gear materials

Rolling element fatigue lives of eleven alloys were evaluated. The eleven alloys studied were three nitriding alloys (Super Nitralloy, Nitralloy 135, and Nitralloy N), four case carburizing alloys (AISI 9310, CBS 600, CBS 1000M and Vasco X-2), and four throughhardening alloys (Vasco Matrix II,AISI W-1, AISI S-2 and AISI O-2). Several different heat treatments and/or melting processes were studied on the three carburizing alloy steels. Metallurgical analyses were made before and after the RC rig tests. Test data were statistically analyzed using the Weibull distribution function. B-10 lives were compared versus VIM-VAR AISI M-50 and carburized VAR AISI 9310, as reference alloys.

Nahm, A. H.↗

Rolling element fatigue testing of gear materials

Rolling element fatigue lives of nine alloys were evaluated in Rolling Contact (RC) rigs. Test conditions included a Hertzian stress at 4,826 MPa (700 ksi), a rolling speed of 6.23 m/sec (245 in/sec.). Tests were run with a Type I oil (MIL-L-7808G) at room temperature. B-10 lives (10% failure rate) of alloys were compared versus reference alloys, VIM-VAR AISI M-50 and VAR AISI 9310. Six case carburizing alloys (AISI 9310, CBS600, CBS1000M, EX00014, Vasco X-2 and EX00053) and three through-hardening alloys (AISI M-50, VascoMax 350 and Vasco Matrix 2 evaluated, showed RCF performance inferior or equivalent to that of AISI 9310 and AISI M-50. It was also found that the effects of vacuum melting processes, different tempering temperatures, freezing cycle during heat treating, shot peening, gold plating and chrome plating employed in the present investigation did not significantly affect RCF life.

Nahm, A. H.↗

The measurement of the synoptic scale wind over the ocean

Mesoscale and microscale features of the turbulent winds over the ocean are related to the synoptic scale winds in terms of published spectral forms for the microscale, a mesoscale valley and published values of U*, VAR u', VAR v' and z/L, as defined in the text and as obtained for moderate to gale force winds. The frequencies involved correspond to periods longer than 1 hour and extend to the microscale, which starts at a period near 2 minutes, or so, and continues to the Kolmogorov inertial range. Nondimensional spectra that span both the mesoscale and the microscale are derived as a function of u, f(= n z/u) and z/L, where z is 10 meters, L is the Monin Obukov stability length and u is evaluated at 10 meters. For the same u, different values of z/L produce a range of values of u which in turn result in variations of the eddy structure of the mesoscale and microscale spectra. Both conventional anemometer averages and remotely sensed winds contain a random component of the mesoscale wind in their values. These components are differnces and not errors when winds are compared, and quantitative values for these differences are given. Ways to improve the measurement of the synoptic scale wind by transient ships, data buoys and scatterometers on future spacecraft are described. These ways are loner averaging times for ships and data buoys, depending on the synoptic conditions, and pooling spacecraft to form super observations. Design considerations for future remote sensing systems are given.

Pierson, W. J.↗

Evaluation of Bogus Vortex Techniques with Four-Dimensional Variational Data Assimilation

The effectiveness of techniques for creating "bogus" vortices in numerical simulations of hurricanes is examined by using the Penn State/NCAR nonhydrostatic mesoscale model (MM5) and its adjoint system. A series of four-dimensional variational data assimilation (4-D VAR) experiments is conducted to generate an initial vortex for Hurricane Georges (1998) in the Atlantic Ocean by assimilating bogus sea-level pressure and surface wind information into the mesoscale numerical model. Several different strategies are tested for improving the vortex representation. The initial vortices produced by the 4-D VAR technique are able to reproduce many of the structural features of mature hurricanes. The vortices also result in significant improvements to the hurricane forecasts in terms of both intensity and track. In particular, with assimilation of only bogus sea-level pressure information, the response in the wind field is contained largely within the divergent component, with strong convergence leading to strong upward motion near the center. Although the intensity of the initial vortex seems to be well represented, a dramatic spin down of the storm occurs within the first 6 h of the forecast. With assimilation of bogus surface wind data only, an expected dominance of the rotational component of the wind field is generated, but the minimum pressure is adjusted inadequately compared to the actual hurricane minimum pressure. Only when both the bogus surface pressure and wind information are assimilated together does the model produce a vortex that represents the actual intensity of the hurricane and results in significant improvements to forecasts of both hurricane intensity and track.

Pu, Zhao-Xia↗

Considerations for Using Hybrid Ensemble-Variational Data Assimilation in NASA-GMAO's Next Reanalysis System

The Modern-Era Retrospective Analysis for Research and Applications, version 2 (MERRA-2) is the latest reanalysis produced by GMAO, and provides global data spanning the period 1980-present. The atmospheric data assimilation component of MERRA-2 used a 3D-Var scheme, which was operational at the time of its design. Since then, a Hybrid 3D-Var, then a Hybrid 4D-EnVar were implemented, adding an ensemble component to the data assimilation scheme. In this work, we will be examining the benefits of using hybrid ensemble flow-dependent covariances to represent errors and uncertainties in historic periods. Specifically, periods of pre- and post-satellites, as well as periods of active tropical cyclone seasons. Finally, we will also be exploring the use of adaptive localization scales.

MERRA-↗

Use of three-cornered hat error estimates in MERRA-2 to guide an improved reanalysis-Part 1

The three-cornered hat (3CH) method estimates the uncertainties of three different co-located model or observational data sets (Anthes and Rieckh, 2018; Sjoberg et al., 2021). Rieckh et al. (2021) used the 3CH method to compare the random error statistics of different global forecast and reanalysis models, as well as radio occultation (RO) and radiosonde observations. That study showed that the MERRA-2 reanalysis, while having smaller errors in the stratosphere than its predecessor MERRA, had larger errors in the troposphere than many of the other data sets analyzed. The MERRA-2 errors were particularly large in the tropics. In a collaborative effort between UCAR’s COSMIC (Constellation Observing System for Meteorology, Ionosphere and Meteorology) program and NASA’s Global Modeling and Assimilation Office (GMAO), we carried out further 3CH error diagnostics to help isolate the causes of these larger errors and help guide the development of an improved reanalysis. This presentation summarizes random error statistics associated with MERRA-2, ECMWF’s ERA5 reanalysis, and COSMIC-2 (C2) RO observations. We compute 3CH error variance estimates of refractivity, as well as temperature and specific humidity using UCAR’s COSMIC Data Analysis and Archive Center (CDAAC) improved 1D-variational (1D-Var) retrieval (wetPf2) over 15 latitude bands from 45S to 45N. The 1D-Var retrievals of specific humidity and temperature for C2 use NCEP’s Global Forecast System (GFS) as the background. Anthes et al. (2021) showed that it gives accurate estimates of temperature and specific humidity in the tropics and subtropics, even in the challenging environment of intense Hurricane Dorian (2019). This presentation confirms the previous results that MERRA-2 has significantly larger errors in the tropics and subtropics than either C2 or ERA5. Its errors are larger between 30S and 30N compared to 30-45 N-S latitudes, and are also larger over land compared to oceans. Most of the MERRA-2 refractivity errors come from specific humidity, except over land below 3 km where temperature errors are large. These results suggest that moist convection and atmospheric boundary layer physics in MERRA-2 may be responsible for a significant part of the higher uncertainties. These results are being used to guide GMAO in developing an improved next-generation reanalysis, as shown in a companion presentation submitted to this conference (El Akkraoui et al., 2021), which extends this study and describes improvements to MERRA-2 leading to the next GMAO reanalysis.

Jeremiah Sjoberg↗

Grid Voltage Control Analysis for Heavy-Duty Electric Vehicle Charging Stations: Preprint

This paper presents an analysis of voltage control strategies for heavy duty electric vehicle (EV) charging stations. The performance of three voltage control approaches including power factor control, preset volt-var curve control, and customized volt-var curve control, have been investigated and evaluated for three different sizes of charging stations, including single-port small charging station, three-port middle size charging station, and 6-port travel center. The charging stations have been placed on various locations of four different types of distribution systems, to obtain a comprehensive performance analysis of the three voltage control approaches under different scenarios. To quantitively compare the performance of the three voltage control approaches, a series of metrics have been designed to quantify the performance and contribute to the comprehensive analysis summary.

47 OTHER INSTRUMENTATION↗

Coordinated voltage control and reactive power regulation between transmission and distribution systems

Systems and methods are described for coordinating volt-var control between sub-transmission and distribution systems. Distributed energy resources of a distribution system are aggregated into virtual power plants from which reactive power can optimally be dispatched to the sub-transmission system. A sub-transmission controller executes a volt-var AC optimal power flow optimisation function to minimize voltage fluctuations that might otherwise occur when coordinating with a distribution system having distributed energy resources. The distribution system can use a sensitivity matrix for regulating voltage at distribution feeders while fulfilling a transmission or sub-transmission system's demand requests.

Samaan, Nader A.↗

Multi-agent voltage control in distribution systems using GAN-DRL-based approach

Active distribution grids can experience voltage fluctuations and violations due to the high penetration of variable distributed energy resources (DERs). These problems might occur because of the uncertain and variable generation natures of these resources, especially solar photovoltaic resources, during panel shadowing scenarios. Volt-VAR control (VVC) is an efficient method that controls the reactive power set-points of the inverters to regulate the voltage of distribution grids. Although several VVC approaches have been proposed recently, the performance of these approaches degrades significantly if behind-the-meter solar generation data are unobservable/missing. Therefore, it is necessary to impute missing/unobservable PV data accurately to be utilized in VVC approaches. Further, this paper proposes a model-free, data-driven, centrally trained, and decentrally executed multi-agent deep reinforcement learning-based VVC architecture to regulate the voltage of distribution networks. A generative adversarial network (GAN) is incorporated to impute the unobservable PV data accurately, which improves the performance of the proposed control architecture. The proposed multi-agent-soft-actor–critic algorithm (MASAC)-based VVC technique utilizes the actual PV dataset as well as the imputed dataset from the GAN framework to learn the optimal coordinated control policy for controlling the optimal reactive power set-points of PV inverters. The effectiveness of the proposed approach is analyzed on a modified IEEE 34-bus test case with added PV inverters. The results are compared and analyzed with a base case model with no VVC and VVC with a local droop control approach, genetic algorithm optimization, and a centralized soft actor–critic-based approach. Moreover, the performance of the proposed approach is compared with that of a multi-agent VVC framework without using the PV generation data and load information as the system state. The results illustrate that the proposed method with more state input improves the voltage profile and reduces the power loss of the network across various loading and PV generation scenarios.

14 SOLAR ENERGY↗

Transporters and ascorbate–glutathione metabolism for differential cadmium accumulation and tolerance in two contrasting willow genotypes

Salix matsudana Koidz is a low cadmium (Cd)-accumulating willow, whereas its cultivated variety, Salix matsudana var. matsudana f. umbraculifera Rehd., is a high Cd-accumulating and tolerant willow (HCW). The physiological and molecular mechanisms underlying differential Cd accumulation and tolerance in the two Salix species are poorly understood. In this study, we confirmed that the differential Cd translocation capacity from roots to the shoots leads to the differential Cd accumulation in their aboveground parts between these two willow genotypes. Cadmium accumulation happens preferentially in the transport pathway, and Cd is mainly located in the vacuolar, cell wall and intercellular space in HCW bark by cadmium location analysis at tissue and subcellular levels. Comparative transcriptome analysis revealed that higher expressions of several metal transporter genes (ATP-binding cassette transporters, K + transporters/channels, yellow stripe-like proteins, zinc-regulated transporter/iron-regulated transporter-like proteins, etc.) are involved in root uptake and translocation capacity in HCW; meanwhile, ascorbate–glutathione metabolic pathways play essential roles in Cd detoxification and higher tolerance of the Cd-accumulator HCW. These results lay the foundation for further understanding the molecular mechanisms of Cd accumulation in woody plants and provide new insights into molecular-assisted-screening woody plant varieties for phytoremediation.

59 BASIC BIOLOGICAL SCIENCES↗

Topology-Aware Reinforcement Learning for Voltage Control: Centralized and Decentralized Strategies

Volt-VAR control (VVC) methods based on deep reinforcement learning (DRL) can effectively control distribution grid voltage and minimize power loss by implementing corrective and preventive control measures on the reactive power output of inverter-based distributed energy resources (DERs). However, model-free DRL-based VVC approaches usually cannot capture the important topological feature of the power system since they use a fully-connected network (FCN) to deliver the action. Therefore, this paper proposes a graph convolutional network (GCN)-based DRL approach that can employ the topological information of the network to take better control action for regulating the voltage. Our implementation allows for both centralized and decentralized configurations, utilizing a single agent and multiple agents respectively. Although the centralized GCN-based DRL approach has its advantages of minimizing voltage fluctuation and power loss, it is not suitable for large scale power systems due to its challenges in terms of scalability, computation speed and potential single points of failure. Therefore, these problems can be resolved using the decentralized GCN-based DRL approach. Moreover, to ensure the safe operation of the model, our proposed approach incorporates an exponential barrier function while formulating the reward function for each agent. To validate performance of the proposed approaches, the proposed model is tested on modified IEEE test systems and the performances are measured in terms on voltage fluctuation reduction, minimization of power loss and computational speed. Finally, the results show that the proposed topology-aware approach outperforms the FCN-based DRL approach in terms of reducing voltage fluctuation and minimizing power loss of the network. Moreover, it is shown that the decentralized GCN-based DRL has faster computational speed than other approaches.

42 ENGINEERING↗

A Scalable Solution for Grid Optimization and DER Integration (CRADA Final Report)

Utilidata Inc. is an energy software company that provides clean energy and digital solutions for utilities. This work was the result of Utilidata Inc. being awarded a New York State Energy Research and Development Agency award to integrate Utilidata volt-VAR optimization (VVO) software with smart inverters to explore enhanced voltage control. This project was conducted in partnership with Utilidata Inc., National Grid, the New York State Energy and Research Development Authority, and the National Renewable Energy Laboratory (NREL). As part of the project NREL conducted modeling and simulation analysis, developed cost-benefit analysis framework, and conducted laboratory testing to understand the potential for smart inverter integration to a centralized VVO control scheme. The remainder of the report provides an executive summary of the work, an introduction to the challenges, sections detailing specific aspects of the work, and the overall findings and conclusions.

14 SOLAR ENERGY↗

A Comparison of DER Voltage Regulation Technologies Using Real-Time Simulations

Grid operators are now considering using distributed energy resources (DERs) to provide distribution voltage regulation rather than installing costly voltage regulation hardware. DER devices include multiple adjustable reactive power control functions, so grid operators have the difficult decision of selecting the best operating mode and settings for the DER. In this work, we develop a novel state estimation-based particle swarm optimization (PSO) for distribution voltage regulation using DER-reactive power setpoints and establish a methodology to validate and compare it against alternative DER control technologies (volt–VAR (VV), extremum seeking control (ESC)) in increasingly higher fidelity environments. Distribution system real-time simulations with virtualized and power hardware-in-the-loop (PHIL)-interfaced DER equipment were run to evaluate the implementations and select the best voltage regulation technique. Each method improved the distribution system voltage profile; VV did not reach the global optimum but the PSO and ESC methods optimized the reactive power contributions of multiple DER devices to approach the optimal solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Aggregated PV on Subsynchronous Torsional Interaction

This paper investigates induced oscillation (specifically subsynchronous torsional interactions) in power systems arising from photovoltaic (PV) power modulation. Time domain simulations of a modified IEEE first-benchmark system are presented and analyzed. In the IEEE benchmark system, a PV generator was added at the same bus where the synchronous generator is connected. The impact of different parameters of the PV inverters’ volt-volt-ampere reactive (volt-var) curve on SSTI is examined. The most severe impact found arises from the time response of the inverter’s reactive power change. A second-order time response with natural frequency matching the rotor speed deviation oscillation frequency and low-damping ratio quickly drives the system to an unstable region. Although it is highly unlikely that conditions necessary for distributed energy resource-induced oscillations would occur in the field, with knowledge of this vulnerability in mind, inverters' control parameters can be designed to avoid it.

41 EE - Solar Energy Technologies Office (EE-4S)↗