Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VANES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

In situ characterization of the biological performance of a Francis turbine retrofitted with a modular guide vane

There are two strategies to lower overall project costs to an extent that will make many potential sustainable hydropower sites economically viable: (1) design standardized/modular components; (2) use advanced tools to reduce environmental evaluation costs. In this study an autonomous sensor device (Sensor Fish) was used to study a Francis turbine retrofitted with a modular guide vane. The median nadir pressures measured were 74.7, 66.6, and 56.6 kPaA for 90-, 190-, and 380-kW operating conditions respectively. These nadir pressures were compared to other Francis turbines studied using Sensor Fish and were found to be within the same range. The proportion of Sensor Fish releases with severe acceleration events (acceleration = 95G) was also investigated. The proportion ranged from 73 to 80% (runner region), 50 to 64% (guide vane region), and 9 to 28% (draft tube region), which was within the range of the other turbines used for comparison. The Sensor Fish testing that was conducted at Hurley Dam demonstrates that the modular guide vane that was retrofitted to the existing Francis turbine is potentially a suitable replacement that can provide biological performance similar to the guide vane used with other existing Francis turbines, but with the benefit of reduced fabrication costs.

13 HYDRO ENERGY↗

Split stator vane row for fans and compressors

Operating noise of fans is reduced by adding part span vanes to vane row of stator, reducing the number of full span vanes and maintaining a vane-to-blade ratio of about 2 to 1.

Volk, L. J.↗

An adverse effect of film cooling on the suction surface of a turbine vane

A J-75 size turbine vane with film cooling holes on the suction surface near the leading edge was tested with and without film cooling flow in a four vane cascade. Results show that the cooling effectiveness on the aft portion of the vane suction surface can decrease with the addition of film cooling near the leading edge. Apparently the film cooling air flow caused a laminar or transitional boundary layer to become a transitional or turbulent boundary layer. The vane was tested at a gas temperature and pressure of 1260 K (1800 F) and 22.7 newtons per square centimeter (33 psia), a coolant temperature of 280 K (50 F), film cooling flow ratios from 0.0 to 0.026, and backside midchord cooling flow ratios of 0.007 and 0.035.

Gladden, H. J.↗

Comparison of temperature data from an engine investigation for film-cooled and non-film-cooled, panwise-finned vanes incorporating impingement cooling

The experimental temperature characteristics of two spanwise-finned, impingement-cooled vanes, one with film cooling and one without film cooling, were investigated in a modified J-75 research turbojet engine. Values of maximum temperature, average temperature, and maximum chordwise temperature difference were compared for the two vanes at the midspan. An analytical redesign of the two vane configurations indicated that the maximum and average temperatures and the maximum chordwise temperature difference could be significantly lowered. The experimental tests indicated that suction-surface film cooling may cause increased heat transfer near the trailing edge of the vane.

Gauntner, D. J.↗

Turbine vane coolant flow variations and calculated effects on metal temperatures

Seventy-two air-cooled turbine vanes were tested to determine coolant flow variations among the vanes. Calculations were made to estimate the effect of measured coolant flow variations on local vane metal temperatures. The calculations were based on the following assumed operating conditions: turbine inlet temperature, 1700 K (2600 F); turbine inlet pressure, 31 N/sq cm (45 psia); coolant inlet temperature, 811 K (1000 F); and total coolant to gas flow ratio, 0.065. Variations of total coolant flow were not large (about 10 percent from the arithmetic mean) for all 72 vanes, but variations in local coolant flows were large. The local coolant flow variations ranged from 8 to 75 percent, and calculated metal temperature variations ranged from 8 to 60 K (15 to 180 F).

Yeh, F. C.↗

Cold-air annular-cascade investigation of aerodynamic performance of core-engine-cooled turbine vanes. 2: Pressure surface trailing edge ejection and split trailing edge ejection

The aerodynamic performance of two trailing edge ejection cooling configurations of a core-engine stator vane were experimentally determined in an ambient inlet-air full-annular cascade where three-dimensional effects could be obtained. The tests were conducted at the design mean-radius ideal aftermixed critical velocity ratio of 0.778. Overall vane aftermixed thermodynamic and primary efficiencies were obtained over a range of coolant flows to about 10 percent of the primary flow at a primary to coolant total temperature ratio of 1.0. The radial variation in efficiency and the circumferential and radial variations in vane-exit total pressure were determined. Comparisons are made with the solid (uncooled) vane.

Mclallin, K. L.↗

Aerodynamic characteristics of a vane flow angularity sensor system capable of measuring flight path accelerations for the Mach number range from 0.40 to 2.54

The aerodynamic characteristics of the angle of attack vane and the angle of sideslip vane are summarized. The test conditions ranged in free stream Mach number from 0.40 to 2.54, in angle of attack from -2 deg to 22 deg, in angle of sideslip from -2 deg to 12 deg, and in Reynolds number from 590,000 per meter to 1.8 million per meter. The results of the wind tunnel investigation are compared with results obtained with similar vane configurations. Comparisons with a NACA vane configuration are also made. In addition, wind tunnel-derived upwash for the test installation is compared with analytical predictions.

Sakamoto, G. M.↗

Experimental studies on the aerodynamic performance and dynamic response of flow direction sensing vanes

Systematic investigations were performed on a variety of aerodynamic surfaces to obtain their potential for possible application to wind vanes. Among the surfaces tested were: (1) single vanes consisting of flat plates of various planforms having aspect ratios between 0.5 and 5; (2) bi-vanes with aspect ratio 2.5; (3) various cone and box vanes; and (4) various cruciform configurations. The models were subjected to windtunnel tests. In addition to lift and drag force measurements, damping and frequency test were performed under a variety of flow conditions.

Barna, P. S.↗

Effect of endwall cooling on secondary flows in turbine stator vanes

An experimental investigation was performed to determine the effect of endwall cooling on the secondary flow behavior and the aerodynamic performance of a core-turbine stator vane. The investigation was conducted in a cold-air, full-annular cascade, where three-dimensional effects could be obtained. In one configuration, the cooling holes were oriented so that the coolant was injected in line with the inviscid streamline direction. In another configuration, the coolant was injected at an angle of 15 deg to the inviscid streamline direction and oriented toward the vane pressure surface. Total-pressure surveys were taken downstream of the stator vanes over a range of cooling flows. Changes in the total-pressure contours downstream of the vanes were used to obtain the effect of endwall cooling on the secondary flows in the stator. Comparisons are made between the two cooled-endwall configurations and with the results obtained previously for solid (uncooled) endwalls.

Goldman, L. J.↗

Laminated turbine vane design and fabrication

A turbine vane and associated endwalls designed for advanced gas turbine engine conditions are described. The vane design combines the methods of convection cooling and selective areas of full coverage film cooling. The film cooling technique is utilized on the leading edge, pressure side, and endwall regions. The turbine vane involves the fabrication of airfoils from a stack of laminates with cooling passages photoetched on the surface. Cold flow calibration tests, a thermal analysis, and a stress analysis were performed on the turbine vanes.

Hess, W. G.↗

Effect of a part-span variable inlet guide vane on the performance of a high-bypass turbofan engine

The ability of a part-span variable inlet guide vane to modulate the thrust of a high bypass turbofan engine was evaluated at altitude/Mach number conditions of 4572 m/0.6 and 9144 m/0.93. Fan-tip, gas generator and supercharger performance were also determined, both on operating lines and during fan duct throttling. The evaluation was repeated with the bypass splitter extended forward to near the fan blade trailing edge. Gross thrust attenuation of over 50% was achieved with 50 deg variable inlet guide vane closure at 100% corrected fan speed. Gas generator supercharger performance fell off with variable inlet guide vane closure but this loss was reduced when a splitter extension was added. The effect of variable inlet guide vane closure on gas generator performance was minimal.

Bobula, G. A.↗

Effect of tip vanes on the performance and flow field of a rotor in hover

Tests run with a single bladed model rotor with a vane located at the tip of the blade indicated significantly increased performance under certain test conditions. Data reveal that a figure of merit increase of over one third occurred in hover. Flow visualization using smoke revealed that a pair of vortices sprung from the blade tip and the vane tip. The vane tip vortex tended to roll up and over the primary vortex. The vortices in the wake became much less well defined with the tip vane configurations.

Velkoff, H. R.↗

Energy efficient engine high-pressure turbine single crystal vane and blade fabrication technology report

The objective of the High-Pressure Turbine Fabrication Program was to demonstrate the application and feasibility of Pratt & Whitney Aircraft-developed two-piece, single crystal casting and bonding technology on the turbine blade and vane configurations required for the high-pressure turbine in the Energy Efficient Engine. During the first phase of the program, casting feasibility was demonstrated. Several blade and vane halves were made for the bonding trials, plus solid blades and vanes were successfully cast for materials evaluation tests. Specimens exhibited the required microstructure and chemical composition. Bonding feasibility was demonstrated in the second phase of the effort. Bonding yields of 75 percent for the vane and 30 percent for the blade were achieved, and methods for improving these yield percentages were identified. A bond process was established for PWA 1480 single crystal material which incorporated a transient liquid phase interlayer. Bond properties were substantiated and sensitivities determined. Tooling die materials were identified, and an advanced differential thermal expansion tooling concept was incorporated into the bond process.

Giamei, A. F.↗

Effect of jet exit vanes on flow pulsations in an open-jet wind tunnel

An investigation was conducted of various jet exit vane configurations in the open test section of the Langley 4- by 7-Meter Tunnel to determine their effectiveness in reducing flow pulsations. The data consist of the instantaneous velocity fluctuations measured with hot-wire anemometers located at the tunnel centerline, 39.5 ft (12.0) downstream of the jet exit. The data are presented in the form of measured root-mean-square turbulence levels in the test section and a time series analysis for the baseline jet exit configuration (without vanes) and forthe most effective vane configuration, which consisted of triangular vanes alternating into and out of the flow around the jet exit.

Sellers, W. L., III↗

Performance of an alpha-vane and pitot tube in simulated heavy rain environment

Experimental tests were conducted in the UDRI Environmental Wind/Rain Tunnel to establish the performance of an alpha-vane, that measures angle of attack, in a simulated heavy rain environment. The tests consisted of emersing the alpha-vane in an airstream with a concurrent water spray penetrating vertically through the airstream. The direction of the spray was varied to make an angle of 5.8 to 18 deg with the airstream direction in order to simulate the conditions that occur when an aircraft lands in a heavy rain environment. Rainrates simulated varied from 1000 to 1200 mm/hr which are the most severe ever expected to be encountered by an aircraft over even a 30 second period. Tunnel airspeeds ranged from 85 to 125 miles per hour. The results showed that even the most severe rainrates produced a misalignment in the alpha-vane of only 1 deg away from the airstream direction. Thus for normal rain conditions experienced by landing aircraft no significant deterioration in alpha-vane performance is expected.

Luers, J. K.↗

De-icing of the altitude wind tunnel turning vanes by electro-magnetic impulse

The Altitude Wind Tunnel at the NASA-Lewis facility is being proposed for a refurbishment and moderization. Two major changes are: (1) the increasing of the test section Mach number to 0.90, and (2) the addition of spray nozzles to provide simulation of flight in icing clouds. Features to be retained are the simulation of atmospheric temperature and pressure to 50,000 foot altitude and provision for full-scale aircraft engine operation by the exhausting of the aircraft combustion gases and ingestion of air to replace that used in combustion. The first change required a re-design of the turning vanes in the two corners downstream of the test section due to the higher Mach number at the corners. The second change threatens the operation of the turning vanes by the expected ice build-up, particulary on the first-corner vanes. De-icing by heat has two drawbacks: (1) an extremely large amount of heat is required, and (2) the melted ice would tend to collect as ice on some other surfaces in the tunnel, namely, the tunnel propellers and the cooling coils. An alternate de-icing method had been under development for three years under NASA-Lewis grants to the Wichita State University. This report describes the electro-impulse de-icing (EIDI) method and the testing work done to assess its applicability to wind tunnel turning vane de-icing. Tests were conducted in the structural dynamics laboratory and in the NASA Icing Research Tunnel. Good ice protection was achieved at lower power consumption and at a wide range of tunnel operations conditions. Recommendations for design and construction of the system for this application of the EIDI method are given.

Zumwalt, G. W.↗

Unsteady aerodynamic load estimates on turning vanes in the national full-scale aerodynamic complex

Unsteady aerodynamic design loads have been estimated for each of the vane sets in the National Full-Scale Aerodynamic Complex (NFAC). These loads include estimates of local loads over one vane section and global loads over an entire vane set. The analytical methods and computer programs used to estimate these loads are discussed. In addition, the important computer input parameters are defined and the rationale used to estimate them is discussed. Finally, numerical values are presented for both the computer input parameters and the calculated design loads for each vane set.

Norman, Thomas R.↗