Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ultrasound techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Ocular examination for trauma; clinical ultrasound aboard the International Space Station

BACKGROUND: Ultrasound imaging is a successful modality in a broad variety of diagnostic applications including trauma. Ultrasound has been shown to be accurate when performed by non-radiologist physicians; recent reports have suggested that non-physicians can perform limited ultrasound examinations. A multipurpose ultrasound system is installed on the International Space Station (ISS) as a component of the Human Research Facility (HRF). This report documents the first ocular ultrasound examination conducted in space, which demonstrated the capability to assess physiologic alterations or pathology including trauma during long-duration space flight. METHODS: An ISS crewmember with minimal sonography training was remotely guided by an imaging expert from Mission Control Center (MCC) through a comprehensive ultrasound examination of the eye. A multipurpose ultrasound imager was used in conjunction with a space-to-ground video downlink and two-way audio. Reference cards with topological reference points, hardware controls, and target images were used to facilitate the examination. Multiple views of the eye structures were obtained through a closed eyelid. Pupillary response to light was demonstrated by modifying the light exposure of the contralateral eye. RESULTS: A crewmember on the ISS was able to complete a comprehensive ocular examination using B- and M-mode ultrasonography with remote guidance from an expert in the MCC. Multiple anteroposterior, oblique, and coronal views of the eye clearly demonstrated the anatomic structures of both segments of the globe. The iris and pupil were readily visualized with probe manipulation. Pupillary diameter was assessed in real time in B- and M-mode displays. The anatomic detail and fidelity of ultrasound video were excellent and could be used to answer a variety of clinical and space physiologic questions. CONCLUSIONS: A comprehensive, high-quality ultrasound examination of the eye was performed with a multipurpose imager aboard the ISS by a non-expert operator using remote guidance. Ocular ultrasound images were of diagnostic quality despite the 2-second communication latency and the unconventional setting of a weightless spacecraft environment. The remote guidance techniques developed to facilitate this successful NASA research experiment will support wider applications of ultrasound for remote medicine on Earth including the assessment of pupillary reactions in patients with severe craniofacial trauma and swelling.

Clinical Trial↗

Highlights of NASA's Role In Developing State-Of-The-Art Nondestructive Evaluation For Composites

Since the 1970's, when the promise of composites was being pursued for aeronautics applications, NASA has had programs that addressed the development of NDE (NonDestructive Evaluation) methods for composites. These efforts included both microscopic and macroscopic NDE. At the microscopic level, NDE investigations interrogated composites at the submicron to micron level to understand a composite's microstructure. A novel microfocus CT system was developed as well as the science underlying applications of acoustic microscopy to a composite's component material properties. On the macroscopic scale NDE techniques were'developed that advanced the capabilities to be faster and more quantitative. Techniques such as stiffness imaging, ultrasonic arrays, laser based ultrasound, advanced acoustic emission, thermography, and novel health monitoring systems were researched. Underlying these methods has been a strong modeling capability that has aided in method development.

Madaras, Eric↗

Highlights of NASA's Role in Developing State-of-the-Art Nondestructive Evaluation for Composites

Since the 1970's, when the promise of composites was being pursued for aeronautics applications, NASA has had programs that addressed the development of NDE methods for composites. These efforts included both microscopic and macroscopic NDE. At the microscopic level, NDE investigations interrogated composites at the submicron to micron level to understand a composite's microstructure. A novel microfocus CT system was developed as well as the science underlying applications of acoustic microscopy to a composite's component material properties. On the macroscopic scale NDE techniques were developed that advanced the capabilities to be faster and more quantitative. Techniques such as stiffness imaging, ultrasonic arrays, laser based ultrasound, advanced acoustic emission, thermography, and novel health monitoring systems were researched. Underlying these methods has been a strong modeling capability that has aided in method development.

Source record↗

Environmental Remediation Technologies Derived from Space Industry Research

Beginning in the 1950s and 1960s, an abundance of effort and initiative was focused on propelling the space industry outward for planetary exploration and habitation. During these early years, the push to take space science to new levels indirectly contributed to the evolution of another science field that would not fully surface until the early 1980s, environmental remediation. This field is associated with the remediation or cleanup of environmental resources such as groundwater, soil, and sediment. Because the space-exploration initiative began prior to the establishment of the U.S. Environmental Protection Agency (EPA) in December of 1970, many NASA Centers as well as space-related support contractors allowed for the release of spent chemicals into the environment. Subsequently, these land owners have been directed by the EPA to responsibly initiate cleanup of their impacted sites. This paper will focus on the processes and lessons learned with the development, testing, and commercialization initiatives associated with four remediation technologies. The technologies include installation techniques for permeable reactive barriers (PRBs), the use of ultrasound to improve long-term performance of PRBs, emulsified zero-valent iron for product-level solvent degradation, and emulsion technologies for application to metal and polychlorinated biphenyl contaminated media. Details of the paper cover technology research, evaluation, and testing; contracts and grants; and technology transfer strategies including patenting, marketing, and licensing.

Quinn, Jacqueline↗

Thermal Inspection of Composite Honeycomb Structures

Composite honeycomb structures continue to be widely used in aerospace applications due to their low weight and high strength advantages. Developing nondestructive evaluation (NDE) inspection methods are essential for their safe performance. Pulsed thermography is a commonly used technique for composite honeycomb structure inspections due to its large area and rapid inspection capability. Pulsed thermography is shown to be sensitive for detection of face sheet impact damage and face sheet to core disbond. Data processing techniques, using principal component analysis to improve the defect contrast, are presented. In addition, limitations to the thermal detection of the core are investigated. Other NDE techniques, such as computed tomography X-ray and ultrasound, are used for comparison to the thermography results.

Zalameda, Joseph N.↗

A scoping review of non-destructive testing (NDT) techniques in building performance diagnostic inspections

Understanding building envelope thermodynamics is an essential foundation of building sciences, mainly due to the envelope’s role as a boundary layer for exterior environments, as well as a container and regulator of internal microclimates. This paper presents a scoping literature review of select Non-destructive Testing (NDT) techniques for building envelope scanning and surveying for thermodynamic diagnostics. The investigation focuses specifically on reviewing six NDT techniques: Ground Penetrating Radar (GPR), Light Detection and Ranging (LiDAR)/Laser Scanning, Thermography, Ultrasound, Close-Range Photogrammetry and Through Wall Imaging Radar (TWIR). The aim is to identify knowledge gaps in terms of their use in accurately characterizing envelope compositions for further integration in Building Energy Modeling (BEM). Each technique was evaluated according to set categories imbibed from the American Society of Heating, Refrigerating, and Air Conditioning Engineering (ASHRAE) Standard 211P that showcase the technique’s ability to extract various relevant information. A framework is then developed to inform users on how to use hybrid NDT-based workflows applied in building envelope energy audits. The study concludes by discussing possibilities of utilizing NDT in large-scale audit automation, BEM integration, and developing built environment policies focusing on increasing existing building performance through retrofitting design.

36 MATERIALS SCIENCE↗

Evaluation of Ultrasonic Battery Inspection Techniques

Lithium metal batteries are prone to subtle defects such as internal dendrites, which can cause internal short circuits and lead to catastrophic ignition. These defects are often undetectable by battery management systems, prompting the need to advance nondestructive evaluation (NDE) techniques for battery applications. In this work, two ultrasonic approaches were compared to establish their relative merits for this application: local ultrasonic resonance spectroscopy, and guided wave ultrasound. Benchtop experiments on batteries seeded with lithium chips emulating plating were used to demonstrate the two techniques. The results show the ability to identify and map local changes in cell structure.

Ultrasound↗

Evaluation of Ultrasonic Battery Inspection Techniques

Lithium metal batteries are prone to subtle defects such as internal dendrites, which can cause internal short circuits and lead to catastrophic ignition. These defects are often undetectable by battery management systems, prompting the need to advance nondestructive evaluation (NDE) techniques for battery applications. In this work, two ultrasonic approaches were compared to establish their relative merits for this application: local ultrasonic resonance spectroscopy, and guided wave ultrasound. Benchtop experiments on batteries seeded with lithium chips emulating plating were used to demonstrate the two techniques. The results show the ability to identify and map local changes in cell structure.

Ultrasound↗

Exploring 3D elastic-wave scattering at interfaces using high-resolution phased-array system

The elastic-wave scattering at interfaces, such as cracks, is essential for nondestructive inspections, and hence, understanding the phenomenon is crucial. However, the elastic-wave scattering at cracks is very complex in three dimensions since microscopic asperities of crack faces can be multiple scattering sources. We propose a method for exploring 3D elastic-wave scattering based on our previously developed high-resolution 3D phased-array system, the piezoelectric and laser ultrasonic system (PLUS). We describe the principle of PLUS, which combines a piezoelectric transmitter and a 2D mechanical scan of a laser Doppler vibrometer, enabling us to resolve a crack into a collection of scattring sources. Subsequently, we show how the 3D elastic-wave scattering in the vicinity of each response can be extracted. Here, we experimentally applied PLUS to a fatigue-crack specimen. We found that diverse 3D elastic-wave scattering occurred in a manner depending on the responses within the fatigue crack. This is significant because access to such information will be useful for optimizing inspection conditions, designing ultrasonic measurement systems, and characterizing cracks. More importantly, the described methodology is very general and can be applied to not only metals but also other materials such as composites, concrete, and rocks, leading to progress in many fields.

36 MATERIALS SCIENCE↗

Acousto-ultrasonic nondestructive evaluation of materials using laser beam generation and detection

Presented in viewgraph format, the possibility of using laser generation and detection of ultrasound to replace piezoelectric transducers for the acousto-ultrasonic technique is advanced. The advantages and disadvantages of laser acousto-ultrasonics are outlined. Laser acousto-ultrasonics complements standard piezoelectric acousto-ultrasonics and offers non-contact nondestructive evaluation.

Huber, Robert D.↗

Resonant ultrasound spectroscopy: The essential toolbox

Resonant Ultrasound Spectroscopy (RUS) is an ultrasound-based minimal-effort high-accuracy elastic modulus measurement technique. RUS as described here uses the mechanical resonances (normal modes of vibration or just modes) of rectangular parallelepiped or cylindrical specimens with a dimension of from a fraction of a millimeter to as large as will fit into the apparatus. Provided here is all that is needed so that the reader can construct and use a state-of-the-art RUS system. Included are links to open-source circuit diagrams, links to download Los Alamos National Laboratory open-source data acquisition software, links to request free analysis software, procedures for acquiring measurements, considerations on building transducers, 3-D printed stage designs, and a full mathematical explanation of how the analysis software extracts elastic moduli from resonances.

47 OTHER INSTRUMENTATION↗

Estimation of elastic properties of an additively manufactured lattice using resonant ultrasound spectroscopy

Development of improved approaches in the characterization of additively manufactured structures continues to be a topic of interest for the advanced manufacturing community. This article will investigate an approach using resonant ultrasound spectroscopy (RUS) to determine the effective elastic constants of an orthotropic lattice structure. The evaluation is performed on a cube shaped 316 L stainless steel test specimen, constructed using selective laser melting techniques. The approach uses RUS techniques in conjunction with the assumption that in the frequency regime of interest, the wavelength of the diagnostic ultrasound is greater than the discrete structural features of the unit cell of the lattice; thus, the AM structure can be treated as an anisotropic continuum with effective material properties and symmetry inherited from the unit cell. The RUS analysis estimates the nine elastic coefficients associated with orthotropic sample symmetry, which, in turn, are used to determine the elastic moduli and Poisson ratios. Current results show good agreement between experiments and modeled data. Comparisons to published results are also in good agreement, indicating the potential applicability of this characterization technique for estimating the linear elastic properties of innovative additive manufactured metal lattice structures.

36 MATERIALS SCIENCE↗

Optimization of Elastodynamic Finite Integration Technique on Intel Xeon Phi Knights Landing Processors

This work describes the development and optimization of an implementation of an isotropic elastodynamic finite integration technique (EFIT) code for parallelized computation on Intel Knights Landing (KNL) hardware. EFIT is a numerical approach resulting in standard staggered-grid finite difference equations for the elastodynamic equations of motion to simulate bulk waves is solids. The computationally efficient simulation of elastodynamic wave propagation and interactions in aerospace materials is of high-interest in the fields of nondestructive evaluation (NDE) and structural health monitoring (SHM). Ultrasonic inspection uses an ultrasonic signal, generated at the surface of the material/structure via use of a piezoelectric transducer, to propagate sound waves into the material where it interacts with any existing defects, as well as with structural boundaries and any material inhomogeneity. Reflections from defects and boundaries are then measured by a transducer. Realistic ultrasound simulation tools can significantly aid the development and optimization of inspection techniques and can assist in the interpretation of experimental data. The optimization of an elastodynamics simulation code for the KNL Many Integrated Core processor was performed. The optimization focused on data locality and vectorization. Results show that tiling of the data to exploit the cache behavior and allow for significant utilization of the KNL hardware. The MPI implementation allows for a scalable implementation enabling large problems to be simulated. The model results were validated against theoretical dispersion curves to within 2% of the group velocity, and within 0.5% of the phase velocity of the A0 mode. Aggressive use of tiling, threading, and vectorization techniques allowed for dramatically improved time to solution.

William C. Schneck↗

Measurement of shear-wave velocity by ultrasound critical-angle reflectometry (UCR)

There exists a growing body of research that relates the measurement of pressure-wave velocity in bone to different physiological conditions and treatment modalities. The shear-wave velocity has been less studied, although it is necessary for a more complete understanding of the mechanical properties of bone. Ultrasound critical-angle reflectometry (UCR) is a noninvasive and nondestructive technique previously used to measure pressure-wave velocities both in vitro and in vivo. This note describes its application to the measurement of shear-wave velocity in bone, whether directly accessible or covered by soft tissue.

NASA Discipline Cardiopulmonary↗

Clinical Outcome Metrics for Optimization of Robust Training

Introduction: The emphasis of this research is on the Human Research Program (HRP) Exploration Medical Capability's (ExMC) "Risk of Unacceptable Health and Mission Outcomes Due to Limitations of In-Flight Medical Capabilities." Specifically, this project aims to contribute to the closure of gap ExMC 2.02: We do not know how the inclusion of a physician crew medical officer quantitatively impacts clinical outcomes during exploration missions. The experiments are specifically designed to address clinical outcome differences between physician and non-physician cohorts in both near-term and longer-term (mission impacting) outcomes. Methods: Medical simulations will systematically compare success of individual diagnostic and therapeutic procedure simulations performed by physician and non-physician crew medical officer (CMO) analogs using clearly defined short-term (individual procedure) outcome metrics. In the subsequent step of the project, the procedure simulation outcomes will be used as input to a modified version of the NASA Integrated Medical Model (IMM) to analyze the effect of the outcome (degree of success) of individual procedures (including successful, imperfectly performed, and failed procedures) on overall long-term clinical outcomes and the consequent mission impacts. The procedures to be simulated are endotracheal intubation, fundoscopic examination, kidney/urinary ultrasound, ultrasound-guided intravenous catheter insertion, and a differential diagnosis exercise. Multiple assessment techniques will be used, centered on medical procedure simulation studies occurring at 3, 6, and 12 months after initial training (as depicted in the following flow diagram of the experiment design). Discussion: Analysis of procedure outcomes in the physician and non-physician groups and their subsets (tested at different elapsed times post training) will allow the team to 1) define differences between physician and non-physician CMOs in terms of both procedure performance (pre-IMM analysis) and overall mitigation of the mission medical impact (IMM analysis); 2) refine the procedure outcome and clinical outcome metrics themselves; 3) refine or develop innovative medical training products and solutions to maximize CMO performance; and 4) validate the methods and products of this experiment for operational use in the planning, execution, and quality assurance of the CMO training process The team has finalized training protocols and developed a software training/testing tool in collaboration with Butler Graphics (Detroit, MI). In addition to the "hands on" medical procedure modules, the software includes a differential diagnosis exercise (limited clinical decision support tool) to evaluate the diagnostic skills of participants. Human subject testing will occur over the next year.

Ebert, D.↗

Application of entropy and signal energy for ultrasound-based classification of three-dimensional printed polyetherketoneketone components

This paper describes a preliminary method for the classification of annealed and unannealed polyetherketoneketone (PEKK) components manufactured using a material extrusion three-dimensional (3D) printing process. PEKK is representative of a class of high-performance thermoplastics that are increasingly employed as feedstocks for use in 3D printing. PEKK components may be used continuously at elevated temperatures, are chemically resistant, and able to withstand large mechanical loads. These properties render PEKK suitable as a metal component replacement in aerospace applications, high-temperature industrial applications, and surgical implants. The structure of PEKK is semi-crystalline with the specific crystallinity correlating to the final properties during application, making determination of this property crucial. This study compares three different signal processing techniques intended to distinguish annealed (high crystallinity) from unannealed (low crystallinity) components using backscattered ultrasound. The first is energy-based and is unable to detect annealing. The second two are based on different entropies of the backscattered signal: a limiting form of Renyi's entropy and a limiting form of joint entropy. The joint entropy values for the annealed and unannealed specimens fall into two non-overlapping intervals and have a statistical separation of two standard deviations.

36 MATERIALS SCIENCE↗

The X-ray attenuation characteristics and density of human calcaneal marrow do not change significantly during adulthood

Changes in the material characteristics of bone marrow with aging can be a significant source of error in measurements of bone density when using X-ray and ultrasound imaging modalities. In the context of computed tomography, dual-energy computed techniques have been used to correct for changes in marrow composition. However, dual-energy quantitative computed tomography (DE-QCT) protocols, while increasing the accuracy of the measurement, reduce the precision and increase the radiation dose to the patient in comparison to single-energy quantitative computed tomography (SE-QCT) protocols. If the attenuation properties of the marrow for a particular bone can be shown to be relatively constant with age, it should be possible to use single-energy techniques without experiencing errors caused by unknown marrow composition. Marrow was extracted by centrifugation from 10 mm thick frontal sections of 34 adult cadaver calcanei (28 males, 6 females, ages 17-65 years). The density and energy-dependent linear X-ray attenuation coefficient of each marrow sample were determined. For purposes of comparing our results, we then computed an effective CT number at two GE CT/i scan voltages (80 and 120 kVp) for each specimen. The coefficients of variation for the density, CT number at 80 kVp and CT number at 120 kVp were each less than 1%, and the parameters did not change significantly with age (p > 0.2, r2 < 0.02, power > 0.8 where the minimum acceptable r2 = 0.216). We could demonstrate no significant gender-associated differences in these relationships. These data suggest that calcaneal bone marrow X-ray attenuation properties and marrow density are essentially constant from the third through sixth decades of life.

NASA Discipline Musculoskeletal↗

Noninvasive Indicators of Intracranial Pressure Before, During, and After Long-Duration Spaceflight

Weightlessness induces a cephalad shift of blood and cerebrospinal fluid that may increase intracranial pressure (ICP) during spaceflight, while lower body negative pressure (LBNP) may provide an opportunity to caudally redistribute fluids and lower ICP. To investigate the effects of spaceflight and LBNP on noninvasive indicators of ICP (nICP), we studied thirteen crewmembers before and after spaceflight in seated, supine, and 15° head-down tilt postures, and at ~45 and ~150 days of spaceflight with and without 25 mmHg LBNP. We used 4 techniques to quantify nICP: cerebral and cochlear fluid pressure (CCFP), otoacoustic emissions (OAE), ultrasound measures of optic nerve sheath diameter (ONSD), and ultrasound-based internal jugular vein pressure (IJVp). On flight day 45, two nICP measures were lower than preflight supine posture (CCFP: mean difference -98.5 -nl [CI: -190.8 to -6.1 -nl], p = 0.037]; OAE: -19.7 degrees [CI: -10.4 to -29.1 degrees], p < 0.001), but not significantly different from preflight seated measures. Conversely, ONSD was not different than any preflight posture, whereas IJVp was significantly greater than preflight seated measures (14.3 mmHg [CI: 10.1 to 18.5mmHg], p < 0.001), but not significantly different than preflight supine measures. During spaceflight, acute LBNP application did not cause a significant change in nICP indicators. These data suggest that during spaceflight nICP is not elevated above values observed in the seated posture on Earth. Invasive measures would be needed to provide absolute ICP values and more precise indications of ICP change during various phases of spaceflight.

Jessica V. Jasien↗