Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTIMATE STRENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

D-1A equipment module structure test

The Centaur Equipment Module (E/M) structural test program was performed in two parts due to an unscheduled hardware failure in the first test series. The objectives of the initial test program were to define the flexibility characteristics of the E/M, verify the design load capability, and determine its ultimate strength capability by loading to structural failure. However, during the first failure test attempt, the Intelsat IV MPA failed instead of the E/M. Therefore a new adapter was fabricated to simulate the HEAO mission adapter and the second series of tests were then performed. They concluded with the failure of the E/M forward interface ring resulting in about 3.5 degrees of permanent set on the high compression side. Nevertheless, the linear or useable strength capability of the E/M is greater or equal to that which is required for the HEAO missions. The E/M is deemed structurally qualified for the HEAO missions.

Niezgoda, T. F.↗

Stress-strain and failure properties of graphite/epoxy laminates

The results of a series of tensile tests on graphite/epoxy laminates at rates varying from 0.002 in/min to 2 in/min are reported. The loads are applied at various angles to the fiber directions in each case. The rate dependent behavior of the stress-strain response is assessed. Evidence is presented to indicate that failure first occurs on inner piles. Also, evidence is presented to indicate that, in some cases, moduli increase with increased stress or strain level. The lamination theory is used to predict moduli and comparisons with experiment are given. Also, the lamination theory is used in conjunction with three failure theories to predict ultimate strengths with varying degrees of success.

Yeow, Y. T.↗

Investigation of a bearingless helicopter rotor concept having a composite primary structure

Experimental and analytical investigations were conducted to evaluate a bearingless helicopter rotor concept (CBR) made possible through the use of the specialized nonisotropic properties of composite materials. The investigation was focused on four principal areas which were expected to answer important questions regarding the feasibility of this concept. First, an examination of material properties was made to establish moduli, ultimate strength, and fatigue characteristics of unidirectional graphite/epoxy, the composite material selected for this application. The results confirmed the high bending modulus and strengths and low shear modulus expected of this material, and demonstrated fatigue properties in torsion which make this material ideally suited for the CBR application. Second, a dynamically scaled model was fabricated and tested in the low speed wind tunnel to explore the aeroelastic characteristics of the CBR and to explore various concepts relative to the method of blade pitch control. Two basic control configurations were tested, one in which pitch flap coupling could occur and another which eliminated all coupling. It was found that both systems could be operated successfully at simulated speeds of 180 knots; however, the configuration with coupling present revealed a potential for undesirable aeroelastic response. The uncoupled configuration behaved generally as a conventional hingeless rotor and was stable for all conditions tested.

Bielawa, R. L.↗

Scanning-electron-microscopy observations and mechanical characteristics of ion-beam-sputtered surgical implant alloys

An electron bombardment ion thruster was used as an ion source to sputter the surfaces of orthopedic prosthetic metals. Scanning electron microscopy photomicrographs were made of each ion beam textured surface. The effect of ion texturing an implant surface on its bond to bone cement was investigated. A Co-Cr-W alloy and surgical stainless steel were used as representative hard tissue implant materials to determine effects of ion texturing on bulk mechanical properties. Work was done to determine the effect of substrate temperature on the development of an ion textured surface microstructure. Results indicate that the ultimate strength of the bulk materials is unchanged by ion texturing and that the microstructure will develop more rapidly if the substrate is heated prior to ion texturing.

Weigand, A. J.↗

Lifetimes of fiber composites under sustained tensile loading

Results are presented for a study intended to summarize lifetime data on several fiber/epoxy composite materials subjected to sustained uniaxial tensile loading, to report preliminary results of an accelerated test method for predicting the life of simple composites, and to describe related work in progress on pressure vessels and other filament-wound structures. The lifetime performance of the tested composites was compared by plotting the percent of ultimate strength (applied fiber stress normalized with respect to fiber failure stress in a composite) versus lifetime. In terms of performance in long-term tensile applications, the tested composites are ranked in the following order: graphite/epoxy, Be wire/epoxy, Aramid/epoxy, and S-glass/epoxy. The accelerated test using temperature and stress to simulate the passage of time proves to be encouraging, at least in the case of the Aramid/epoxy composite. The potential of a statistical analysis based on Weibull distribution analyses or a power law relationship is demonstrated.

Chiao, T. T.↗

Plane-stress fracture of compact and notch-bend specimens

Thin-gaged or high toughness materials containing cracks usually fail in a ductile manner with nominal failure stresses approaching the ultimate strength of the material. For such materials, a two-parameter fracture criterion was developed. An equation which related the linear elastic stress-intensity factor, elastic nominal stress, and two material parameters has previously been derived and has been used as a fracture criterion for surface- and through-cracked specimens under tensile loading. In the present paper the two-parameter fracture criterion was rederived in a more general form and was extended to compact and notch-bend fracture specimens. A close correlation was found between experimental and calculated failure stresses.

Newman, J. C., Jr.↗

Experimental evaluation of the tensor polynomial criterion for designing composite structures

A comprehensive experimental and analytical evaluation of the tensor polynomial failure criterion was undertaken to determine its capability for predicting the ultimate strength of a composite limina subject to a plane stress state. Results are presented demonstrating that a quadratic formulation is too conservative and a cubic representation is required. Strength comparisons with test data derived from glass/epoxy and graphite/epoxy tubular specimens are also provided to validate the cubic strength criterion. Environmental effects including ambient temperature, exposure to vacuum, length of post-cure time, and rate of cool down were also investigated. Behavior changes associated with polymer (epoxy) matrix composites were determined in terms of variations in stiffness and tensile strength.

Tennyson, R. C.↗

Mechanical properties of ion-beam-textured surgical implant alloys

An electron-bombardment Hg ion thruster was used as an ion source to texture surfaces of materials used to make orthopedic and/or dental prostheses or implants. The materials textured include 316 stainless steel, titanium-6% aluminum, 4% vanadium, and cobalt-20% chromium, 15% tungsten. To determine the effect of ion texturing on the ultimate strength and yield strength, stainless steel and Co-Cr-W alloy samples were tensile tested to failure. Three types of samples of both materials were tested. One type was ion-textured (the process also heats each sample to 300 C), another type was simply heated to 300 C in an oven, and the third type was untreated. Stress-strain diagrams, 0.2% offset yield strength data, total elongation data, and area reduction data are presented. Fatigue specimens of ion textured and untextured 316 stainless steel and Ti-6% Al-4% V were tested. Included as an ion textured sample is a Ti-6% Al-4% V sample which was ion machined by means of Ni screen mask so as to produce an array of 140 mu m x 140 mu m x 60 mu m deep pits. Scanning electron microscopy was used to characterize the ion textured surfaces.

Weigand, A. J.↗

The compressive failure of graphite/epoxy plates with circular holes

The behavior of fiber reinforced composite plates containing a circular cutout was characterized in terms of geometry (thickness, width, hole diameter), and material properties (bending/extensional stiffness). Results were incorporated in a data base for use by designers in determining the ultimate strength of such a structure. Two thicknesses, 24 plies and 48 plies were chosen to differentiate between buckling and strength failures due to the presence of a cutout. Consistent post-buckling strength was exhibited by both laminate configurations.

Knauss, J. F.↗

Evaluation of the tensor polynomial failure criterion for composite materials

A comprehensive experimental and analytical evaluation of the tensor polynomial failure criterion was undertaken to determine its capability for predicting the ultimate strength of laminated composite structures subject to a plane stress state. Results are presented demonstrating that a quadratic formulation is too conservative and a cubic representation is required. Strength comparisons with test data derived from glass/epoxy and graphite/epoxy tubular specimens are also provided to validate the cubic strength criterion.

Tennyson, R. C.↗

Hydrogen attack - Influence of hydrogen sulfide

An experimental study is conducted on 12.5-mm-thick SAE 1020 steel (plain carbon steel) plate to assess hydrogen attack at room temperature after specimen exposure at 525 C to hydrogen and a blend of hydrogen sulfide and hydrogen at a pressure of 3.5 MN/sq m for exposure times up to 240 hr. The results are discussed in terms of tensile properties, fissure formation, and surface scales. It is shown that hydrogen attack from a high-purity hydrogen environment is severe, with the formation of numerous methane fissures and bubbles along with a significant reduction in the room-temperature tensile yield and ultimate strengths. However, no hydrogen attack is observed in the hydrogen/hydrogen sulfide blend environment, i.e. no fissure or bubble formation occurred and the room-temperature tensile properties remained unchanged. It is suggested that the observed porous discontinuous scale of FeS acts as a barrier to hydrogen entry, thus reducing its effective equilibrium solubility in the iron lattice. Therefore, hydrogen attack should not occur in pressure-vessel steels used in many coal gasification processes.

Eliezer, D.↗

Development of low modulus material for use in ceramic gas path seal applications

Three candidate materials were examined: Brunsbond (R) Pad; plasma sprayed porous NiCrAlY; and plasma sprayed low modulus microcracked zirconia. Evaluation consisted of mechanical, thermophysical, and oxidation resistance testing along with optical microscopy and a feasibility demonstration of attaching the material to a suitable substrate. The goals of the program were the following: feasibility of fastening or depositing the low modulus system onto a broad range of substrate alloys; feasibility of depositing or forming the low modulus system to a thickness of 0.19 cm to 0.38 cm; potential to attain a modulus of elasticity in the range of 3.4 to 6.9 GPa (0.5 to 1.0 MSI), and an ultimate strength of 17.2 MPa (2.5 ksi); suitable thermal conductivity; and static oxidation life of at least 1000 hours at 1311 K. The results of the program indicate that all three systems offer attractive properties as a strain isolator material.

Eaton, H. E.↗

Three dimensional finite element analysis of damage accumulation in composite laminate

A three dimensional finite-element computer program has been developed to analyze layered fiber-reinforced composite laminate. This program is capable of: (1) calculating the detailed stress distribution, (2) identifying the damage zone and mode of failure, (3) analyzing the damage accumulation, and (4) determining the ultimate strength of the composite laminate.

Lee, J. D.↗

Scaled centrifugal compressor, collector and running gear program

The Scaled Centrifugal Compressor, Collector and Running gear Program was conducted in support of an overall NASA strategy to improve small-compressor performance, durability, and reliability while reducing initial and life-cycle costs. Accordingly, Garrett designed and provided a test rig, gearbox coupling, and facility collector for a new NASA facility, and provided a scaled model of an existing, high-performance impeller for evaluation scaling effects on aerodynamic performance and for obtaining other performance data. Test-rig shafting was designed to operate smoothly throughout a speed range up to 60,000 rpm. Pressurized components were designed to operate at pressures up to 300 psia and at temperatures to 1000 F. Nonrotating components were designed to provide a margin-of-safety of 0.05 or greater; rotating components, for a margin-of-safety based on allowable yield and ultimate strengths. Design activities were supported by complete design analysis, and the finished hardware was subjected to check-runs to confirm proper operation. The test rig will support a wide range of compressor tests and evaluations.

Kenehan, J. G.↗

Temperature dependence of mechanical and thermal expansion properties of T300/5208 graphite/epoxy

The 116-394 K temperature range elastic constants, ultimate strengths and thermal expansion behavior of T300/5208 graphite/epoxy laminates of various different lay-up types have been determined. It is noted that most properties exhibit nearly linear temperature dependencies, although the transverse modulus and axial thermal expansion vary nonlinearly with temperature, and change in value by an order of magnitude over the present temperature range.

Hyer, M. W.↗

Engineering and design properties of thallium-doped sodium iodide and selected properties of sodium-doped cesium iodide

Mechanical and thermal properties, not available in the literature but necessary to structural design, using thallium doped sodium iodide and sodium doped cesium iodide were determined to be coefficient of linear thermal expansion, thermal conductivity, thermal shock resistance, heat capacity, elastic constants, ultimate strengths, creep, hardness, susceptibility to subcritical crack growth, and ingot variation of strength. These properties were measured for single and polycrystalline materials at room temperature.

Forrest, K.↗

Formulation/cure technology for ultrahigh molecular weight silphenylene-siloxane polymers

Molecular weights above one million were achieved for methylvinylsilphenylene-siloxane terpolymers using a two-stage polymerization technique which was successfully scaled up to 200 grams. The resulting polymer was vulcanized by two different formulations and compared to an identically formulated commercial methylvinyl silicone on the basis of ultimate strength, Young's modulus, percent elongation at failure, and tear strength. Relative thermal/oxidative stabilities of the elastomers were assessed by gradient and isothermal thermogravimetric analyses performed in both air and nitrogen. The experimental elastomer exhibited enhanced thermal/oxidative stability and possed equivalent or superior mechanical properties. The effect of variations in prepolymer molecular weight on mechanical properties was also investigated.

Hundley, N. H.↗

Effects of High Mean Stress on High-cycle Fatigue Behavior of PWA 1480

PWA 1480 is a potential candidate material for use in the high-pressure fuel turbine blade of the space shuttle main engine. As an engine material it will be subjected to high-cycle fatigue loading superimposed on a high mean stress due to combined centrifugal and thermal loadings. The present paper describes the results obtained in an ongoing program at the Argonne National Laboratory, sponsored by NASA Lewis, to determine the effects of a high mean stress on the high-cycle fatigue behavior of this material. Straight-gauge high-cycle fatigue specimens, 0.2 inch in diameter and with the specimen axis in the 001 direction, were supplied by NASA Lewis. The nominal room temperature yield and ultimate strength of the material were 146 and 154 ksi, respectively. Each specimen was polished with 1-micron diamond paste prior to testing. However, the surface of each specimen contained many pores, some of which were as large as 50 micron. In the initial tests, specimens were subjected to axial-strain-controlled cycles. However, very little cyclic plasticity was observed.

Majumdar, S.↗