Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tipping Point”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

121 records · Page 7

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence Q - Raw Data

Sequence Q: Dynamic Inflow (P) This sequence was designed to characterize the dynamic inflow variation using the five-hole probes that extend upwind of the leading edge of the blade. This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speeds ranged from 5 m/s to 15 m/s, and data were collected at a 0° yaw angle. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pretensioned to 40,000 N. The blade pitch angle was changed from the initial tip pitch angle to the final tip pitch angle at the maximum rate of 67°/s. This angle was maintained for the specified delay time duration. Then the blade was pitched back to the initial pitch angle and held for the specified hold time. This was repeated 20 times. The campaign at 15 m/s was aborted early due to excessive low-speed shaft torque loads. The file length varied depending on the time required to obtain 20 pitch cycles for the specified range of angles. The name convention was the standard format, except for the short campaigns collected to ascertain the functionality of the instrumentation. These points were collected at a 3° pitch angle and use the characters REF in the four digits that normally represent yaw angle.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 7 - Raw Data

Sequence 7: Shroud Operating (P) This test sequence used a downwind, rigid turbine with a 3.4° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Turntable angles from 0° to 30° were achieved, but the yaw error angle was maintained at 0° by adjusting the nacelle yaw. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. An airfoil-shaped aluminum shroud was placed on the tower below the 34% span five-hole probe. It extended below the 91% span five-hole probe. The turntable angle was adjusted to position the shroud at various angles relative to the flow, but the turbine yaw error angle was maintained at 0°. Two additional points were collected where the turntable angle was 0°, and the turbine yaw angle was 20° (71000200) or -20° (710M0200).

17 WIND ENERGY↗

Diagnosis of PV Cell Passivation Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on the cell ("AR c corrosion") was previously observed in studies using hot-humid test conditions with external high voltage (HV) bias. Because AR c corrosion is not well understood, mini-modules (MiMos) were examined in a comparative experiment using PERC and PERT as well as legacy Al-BSF cells. For separate MiMos with the cell circuit electrical at +1500 V, -1500 V, or unbiased "V oc", test conditions in the comparative study included 60degrees C/60% RH for 96 h, as in IEC TS 62804-1; 70degrees C/70%RH for 200 h; and 85degrees C/85% RH for 200 h. Characterizations at each read point included: camera and electroluminescence (EL) imaging, colorimetry, and I-V curve tracing. Characterizations at the final read point included: SunsVoc; spatially mapping external quantum efficiency (EQE); high resolution: photoluminescence (PL), EL, and dark lock-in thermographic (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos (stepped HV aging) and full-sized modules (outdoor aging) from previous studies. AR c corrosion was specifically observed for the glass/encapsulant/cell side of +1500 V (HV+) stressed MiMos, where appearance, color, and reflectance were the characteristics most distinguished relative to simultaneously occurring degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to silicon oxide or hydrous silica, preferentially occurring at the edges and tips of the pyramidal textured cell surface.

aging↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence P - Raw Data

Sequence P: Wake Flow Visualization, Upwind (P) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 15 m/s. Yaw angles of 0° to –60° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. The aluminum blade tip designed to contain a smoke generator was installed, and counterweights were installed in the non-instrumented blade tip to compensate. The turbine was positioned at the appropriate yaw angle, and the smoke generator was ignited remotely. The campaign duration was 3 minutes for all tests except P1000000, which was 2 minutes. The file name convention was the standard format except for P10000A0, which indicated a 3° pitch angle. File P1000000 used a 12° pitch angle. After these two campaigns were collected, it was determined that all subsequent data should be collected with a 3° pitch angle. Pressure data were not acquired during this sequence, so all associated data values were flagged as not applicable by setting the measured values in the data file to 0.000 Pa. Corresponding pressure data are available from Sequence H for the 3° pitch angle test points. Flow visualization data obtained from wall- and ceiling-mounted video cameras were recorded to videotape. The camera locations and calibration procedures are described in Appendix J.

17 WIND ENERGY↗

Array of Graphene Variable Capacitors on 100 mm Silicon Wafers for Vibration-Based Applications

Highly flexible, electrically conductive freestanding graphene membranes hold great promise for vibration-based applications. This study focuses on their integration into mainstream semiconductor manufacturing methods. We designed a two-mask lithography process that creates an array of freestanding graphene-based variable capacitors on 100 mm silicon wafers. The first mask forms long trenches terminated by square wells featuring cone-shaped tips at their centers. The second mask fabricates metal traces from each tip to its contact pad along the trench and a second contact pad opposite the square well. A graphene membrane is then suspended over the square well to form a variable capacitor. The same capacitor structures were also built on 5 mm by 5 mm bare dies containing an integrated circuit underneath. We used atomic force microscopy, optical microscopy, and capacitance measurements in time to characterize the samples.

36 MATERIALS SCIENCE↗

The DESI DR1 Peculiar Velocity Survey: Global Zero-point and H 0 Constraints

The Dark Energy Spectroscopic Instrument (DESI) in its first Data Release (DR1) already provides more than 100,000 galaxies with relative distance measurements. The primary purpose of this paper is to perform the calibration of the zero-point for the DESI Fundamental Plane and Tully–Fisher relations, which allows us to measure the Hubble constant, H 0 . This sample has a lower statistical uncertainty than any previously used to measure H 0 , and we investigate the systematic uncertainties in absolute calibration that could limit the accuracy of that measurement. We improve upon the DESI Early Data Release Fundamental Plane H 0 measurement by (a) using a group catalog to increase the number of calibrator galaxies and (b) investigating alternative calibrators in the nearby Universe. Our baseline measurement calibrates to the SH0ES/Pantheon+ type Ia supernovae, and finds H 0 = 73.7 ± 0.06 (stat.) ± 1.1 (syst.) km s −1 Mpc −1 . Calibrating to surface brightness fluctuation distances yields a similar H 0 . We explore measurements using other calibrators, but these are currently less precise since the overlap with DESI peculiar velocity tracers is much smaller. In future data releases with an even larger peculiar velocity sample, we plan to calibrate directly to Cepheids and the tip of the red giant branch, which will enable the uncertainty to decrease towards a percent-level measurement of H 0 . This will provide an alternative to supernovae as the Hubble flow sample for H 0 measurements.

Carr, Anthony [Korea Astronomy and Space Science I↗

Photometric calibration in u -band using blue halo stars

ABSTRACT We develop a method to calibrate u-band photometry based on the observed colour of blue Galactic halo stars. The Galactic halo stars belong to an old stellar population of the Milky Way and have relatively low metallicity. The ‘blue tip’ of the halo population – the main sequence turn-off (MSTO) stars – is known to have a relatively uniform intrinsic edge u-g colour with only slow spatial variation. In SDSS data, the observed variation is correlated with Galactic Latitude, which we attribute to contamination by higher metallicity disc stars and fit with an empirical curve. This curve can then be used to calibrate u-band imaging if g-band imaging of matching depth is available. Our approach can be applied to single-field observations at |b| > 30°, and removes the need for standard star observations or overlap with calibrated u-band imaging. We include in our method the calibration of g-band data with ATLAS-Refcat2. We test our approach on stars in KiDS DR 4, ATLAS DR 4, and DECam imaging from the NOIRLab Source Catalog (NSC DR2), and compare our calibration with SDSS. For this process, we use synthetic magnitudes to derive the colour equations between these data sets, in order to improve zero-point accuracy. We find an improvement for all data sets, reaching a zero-point precision of 0.016 mag for KiDS (compared to the original 0.033 mag), 0.020 mag for ATLAS (originally 0.027 mag), and 0.016 mag for DECam (originally 0.041 mag). Thus, this method alone reaches the goal of 0.02 mag photometric precision in u-band for the Rubin Observatory’s Legacy Survey of Space and Time (LSST).

79 ASTRONOMY AND ASTROPHYSICS↗

Fault Characterization and Diagnostics Supporting Condition-Based Operation and Maintenance of Gas Turbine Engines

Condition-Based Operation and Maintenance (CBOM) is the state-of-the-art in maintenance approaches for gas turbine engines. CBOM applies engine sensor information to the optimization of future operation and maintenance procedures; this technique reduces costs for engine operators by minimizing unplanned outages and catastrophic engine degradation. However, due to the complexities of gas turbine operation and the lack of available engine sensors, further development is required to fully realize the benefits of CBOM. In the turbine section, rotating components interact with high temperature flows, which creates intense thermal and mechanical stresses. As a result, there are numerous mechanisms of component degradation in the turbine section. Furthermore, turbine components – like stator vanes and rotor blades – are among the most expensive in the engine because they are complex to design and manufacture. For these reasons, this dissertation addresses two main questions: (i) which parameters or faults within the turbine section are most important to monitor, and (ii) how can these parameters or faults be monitored in an engine-relevant environment? Although many turbine parameters and faults have been investigated in the open literature, there are some faults that are still not well understood. Rotor-casing eccentricity, which causes a non-constant blade tip clearance around the annulus, has not been investigated in terms of its effects on turbine efficiency. Therefore, the first study in this dissertation quantifies overall and local turbine efficiency for varying levels of rotor-casing eccentricity. Results showed negligible variations to overall turbine efficiency, meaning rotor-casing eccentricity only becomes relevant to CBOM when its severity causes rotordynamic issues. Purge flow is critical to turbine hardware longevity because it prevents ingestion of hot main gas path (MGP) flow into the under-platform regions. Despite its importance, there are currently no methods for monitoring purge flow performance in an engine environment. Therefore, the second study in this dissertation develops a predictive model for sealing effectiveness using inputs from two fast-response pressure sensors. Results exhibited low prediction errors across a full range of purge flow rates, which supports the viability of the modelling approach for CBOM. The final two studies in this dissertation address blade coolant flow monitoring. This cooling flow is responsible for protecting the turbine blades from the MGP flow, which exits the combustor at temperatures greater than the blade melting point. These studies showed that temperature measurements on the blade surface can be used to accurately predict blade coolant flow rate, and that defining the candidate features relative to the coolant trajectory is important for maintaining accuracy as coolant flow rate degradation occurs. This work enables blade coolant flow monitoring, which is currently not possible through existing condition monitoring techniques.

condition-based, gas turbines, diagnostics,↗

Impact of Flow Configurations on Response Time and Data Quality in Real-Time, In-Line Fourier Transform Infrared (FTIR) Monitoring of Viscous Flows

The real-time, in-line monitoring of continuous flow concentrations is widely conducted via infrared (IR) spectrometry by using a flow cell connected to a reactive flow stream. For protective purposes, the IR sensor tip is typically offset from the flow. This offset can cause the formation of a stagnant boundary layer above the sensor, especially when dealing with high-viscosity fluids. As a result, the IR signal response time is often controlled by the slow diffusional exchange of fluid in the boundary layer, as confirmed via 2D computational fluid dynamics (CFD) simulations. We evaluated several flow configuration modifications in a typical IR flow cell in order to identify the changes to the flow dynamics that enable improved response times with minimal changes to the cell configuration: the use of (i) vertical flow, where the standard horizontal flow over the sensor is redirected to contact vertically with the sensor, (ii) a static mixer to create radial flow momentum above the IR sensor, and (iii) horizontal or vertical nozzles to direct the flow toward the IR sensor. The vertical flow configuration did not show any significant improvement over the standard horizontal flow configuration. However, the static mixer, horizontal nozzle, and vertical nozzle configurations all resulted in markedly improved response times and signal quality, albeit at the expense of a higher pressure drop across the flow cell. These results point toward straightforward, user-accessible modifications of in-line IR flow cells that result in significant improvements in signal stability and acquisition times.

42 ENGINEERING↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rapid Demonstration of Bremsstrahlung Diode Optimization

Optimization of the radiation pattern from a Bremsstrahlung target for a given application is possible by controlling the electron beam that impacts the high-atomic-number target. In this work, the electron beam is generated by a 13MV vacuum diode that terminates a coaxial magnetically insulted transmission line (MITL) on the HERMES-III machine at Sandia National Labs. Work by Sanford introduced a geometry for vacuum diodes that can control the flow within bounds. The "indented anode", as coined by Sanford, can straighten out the electron beam in a high-current diode that would otherwise be prone to beam pinching. A straighter beam will produce a more forwardly directed radiation pattern while a pinching electron beam will yield a focal point or hot spot on axis and a more diffuse radiation pattern. Either one of these may be desirable depending on the application. This work serves as a first attempt to optimize the radiation pattern in the former sense of collimating the radiation pattern given a limited parameter space. The optimization is attempted first using electromagnetic particle-in-cell simulations in the EMPIRE code suite. The setup of the models used in EMPIRE is discussed along with some basic theory behind some of the models used in the simulations such as anode heating and secondary ions. Theoretical work performed by Allen Garner and his students at Purdue is included here, which concerns the impact of collisions in these vacuum diodes. The EMPIRE simulations consider both an aggressive and a conservative design. The aggressive design is inherently riskier while the conservative design is chosen as something that, while still a risk, is more likely to perform as expected. The ultimate goal of this work was to validate the EMPIRE code results with experimental data. While the experiment that tested the diode designs proposed by the simulation results fell outside of the fiscal boundaries of this project (and for that reason the results of which are not included in this report), the hardware for the experiment was designed and drafted within those same fiscal boundaries, and is thus included in this report. However, there was yet another experiment performed in this project that tested a key feature of the diode: the hemispherical cathode. Those results are documented here as well, which show that the cathode tip is an important aspect to controlling the diode flow. A short series of simulations on this diode were also performed after the experiment in order to gain a better understanding of the effect of ions. on the flow pattern and faceplate dose profile.

43 PARTICLE ACCELERATORS↗

Complex Dependence of Calcite Crack Kinetics on Salinity: The Role of DLVO and Hydration Forces

Abstract Subcritical crack growth (SCG) plays an important role in many geological processes such as delayed earth rupture and rock weathering. The complex dependency of SCG on the in‐crack fluid chemistry, however, is still poorly understood. In this study, we utilize the newly developed surface force‐based fracture theory (SFFT) to elucidate the relative contributions of surface forces and solute transport to the crack growth kinetics of calcite in NaCl solutions. Expanding on Barenblatt's cohesive crack model, SFFT introduces an effective stress intensity at the crack tip that encompasses all the relevant intermolecular forces across the crack in addition to the external far‐field stresses. The nonlinear system of equations portraying the crack opening profile, the solute distribution in a propagating crack, and the crack growth velocity are numerically solved via an implicit scheme. After carefully calibrating the model for calcite‐water systems, the SFFT is used to predict the SCG response of calcite at different NaCl concentrations, based on various hypotheses. These predictions are then compared to existing SCG data from the literature. We demonstrate that the experimentally observed variation of SCG rate with NaCl concentration cannot be explained solely by DLVO forces (electrostatic and Van der Waals interactions). This can be remediated by introducing an exponentially decaying hydration force with a nonlinear, nonmonotonic dependence on NaCl concentration. Furthermore, we demonstrate that accounting for both diffusive and advective transport of ions is important in explaining the absence of a stage‐II SCG response for calcite in electrolyte solutions. Plain Language Summary Subcritical crack growth (SCG) refers to the slow propagation of cracks in materials under a stress below the threshold for catastrophic failure. SCG is a key process in many geological events, for example, delayed earth ruptures and rock weathering. New initiatives such as underground CO 2 and H 2 storage in carbonate reservoirs further call for better understanding of SCG in carbonate minerals subjected to varying fluid chemistry. This study examines the SCG of calcite, a key mineral found in carbonate rocks, intergranular cement in sandstones, and filling material in mineral veins and faults, determining their deformation and strength. A mathematical model is developed to describe how the crack opens and propagates, how solutes (like salts) distribute within the crack, and how the crack surfaces interact with each other. We used the model to predict calcite SCG in water at different salt concentrations and compared it with experimental data. Our results revealed that the hydration force is the dominating factor in determining the complex, non‐linear dependency of SCG on salinity. We also found that both the movement of ions by diffusion and by bulk water flow are crucial for explaining the SCG rates, especially when the cracks grow quickly. Key Points Surface Force‐Based Fracture Theory predicts the complex subcritical crack growth patterns of calcite crystals immersed in NaCl solutions Results highlight the dominant role of hydration forces in altering the fracture behavior of calcite compared to VdW and electric double‐layer forces Advective solute transport explains the absence of stages‐II and ‐III subcritical crack growth responses in solid‐liquid systems

DLVO↗

Mapping existing wellbore locations to compare technical risks between onshore and offshore CCS activities in Texas

Carbon dioxide capture and geologic storage (CCS; geologic sequestration) is a promising technology for reducing anthropogenic greenhouse gas emissions to the atmosphere from industrial point sources. Aspects of CCS have been investigated for over two decades, and many large- and small-scale geologic storage field demonstration projects are now underway globally. Interest in offshore CCS has been increasing in recent years (e.g., European Union, Australia, Japan, and the United States). Deep geologic storage in offshore settings is analogous to onshore CCS activities in many respects (i.e., geologic and geotechnical aspects), but is distinct from previously explored seabed sediment CO 2 storage) or deep marine dissolution). Given the large subsurface geologic storage volumes available in offshore settings, much discussion of offshore CCS is focused on the benefits and risks of such activity compared to onshore settings. Similar to onshore settings, existing (legacy) wells likely present the most direct migration pathway and largest risk of noncontainment in offshore settings. As part of current studies to evaluate geologic storage options in offshore settings along the Texas coast and greater Gulf of Mexico (GoM), mapping of the geographic distribution and ages of wells in a region containing coastal counties and extending 30 miles offshore Texas indicates that both well spatial density and well age decrease moving from onshore to offshore. Results suggest reduced risk of leakage owing to more rigorous and documented well completion and abandonment practices for these generally younger wells (although many are decades old). A result of decreased well density is that larger areas are available for leasing for CCS projects that avoid legacy wells altogether (> 1 mile from any existing well). The one-mile designation is used as an arbitrary convention, and while it is recognized that this is smaller than a typical area of review (AoR) for permitting, each site will have a different AoR radius for consideration. Finally, the combination of large subsurface storage volumes under control of a single landowner and reduced risks from legacy wells makes offshore CCS attractive in the GoM.

58 GEOSCIENCES↗