Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Atomic-scale quantum sensing based on the ultrafast coherence of an H 2 molecule in an STM cavity

A scanning tunneling microscope (STM) combined with a pump-probe femtosecond terahertz (THz) laser can enable coherence measurements of single molecules. We report THz pump-probe measurements that demonstrate quantum sensing based on a hydrogen (H 2 ) molecule in the cavity created with an STM tip near a surface. Atomic-scale spatial and femtosecond temporal resolutions were obtained from this quantum coherence. The H 2 acts as a two-level system, with its coherent superposition exhibiting extreme sensitivity to the applied electric field and the underlying atomic composition of the copper nitride (Cu 2 N) monolayer islands grown on a Cu(100) surface. We acquired time-resolved images of THz rectification of H 2 over Cu 2 N islands for variable pump-probe delay times to visualize the heterogeneity of the chemical environment at sub-angstrom scale.

Science & Technology - Other Topics↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Recovering magnetization distributions from their noisy diffraction data

We study, using simulated experiments inspired by thin-film magnetic domain patterns, the feasibility of phase retrieval in x-ray diffractive imaging in the presence of intrinsic charge scattering given only photon-shot-noise limited diffraction data. We detail a reconstruction algorithm to recover the sample's magnetization distribution under such conditions and compare its performance with that of Fourier transform holography. Concerning the design of future experiments, we also chart out the reconstruction limits of diffractive imaging when photon-shot-noise and the intensity of charge scattering noise are independently varied. This work is directly relevant to the time-resolved imaging of magnetic dynamics using coherent and ultrafast radiation from x-ray free-electron lasers and also to broader classes of diffractive imaging experiments which suffer noisy data, missing data, or both.

36 MATERIALS SCIENCE↗

Implementation of focal zooming on the Nike KrF laser

In direct drive inertial confinement laser fusion, a pellet containing D-T fuel is imploded by ablation arising from absorption of laser energy at its outer surface. For optimal coupling, the focal spot of the laser would continuously decrease to match the reduction in the pellet's diameter, thereby minimizing wasted energy. A krypton-fluoride laser ({lambda}= 248 nm) that incorporates beam smoothing by induced spatial incoherence has the ability to produce a high quality focal profile whose diameter varies with time, a property known as focal zooming. A two-stage focal zoom has been demonstrated on the Nike laser at the Naval Research Laboratory. In the experiment, a 4.4 ns laser pulse was created in which the on-target focal spot diameter was 1.3 mm (full width at half maximum) for the first 2.4 ns and 0.28 mm for the final 2 ns. These two diameters appear in time-integrated focal plane equivalent images taken at several locations in the amplification chain. Eight of the zoomed output beams were overlapped on a 60 {mu}m thick planar polystyrene target. Time resolved images of self-emission from the rear of the target show the separate shocks launched by the two corresponding laser focal diameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Penetration of Ar and He RF-driven plasma jets into micrometer-sized capillary tubes

The penetration and propagation of cold atmospheric pressure plasmas into volumes having sub-millimeter to micrometer sizes with large aspect ratios is required for enabling an effective disinfection of the inside of catheter tubes, tooth cavities, skin pores and enhance plasma catalysis in porous catalysts. Here, we report on a study using a low voltage RF driven argon and helium plasma jets with the plasma generation outside a capillary tube with a large aspect ratio followed by its penetration and propagation inside the capillary. We present the experimental determination of the limitations on the penetration diameter, and the underpinning mechanisms of the plasma propagation and penetration process. Experimental results include time resolved imaging of plasma propagation and penetration in capillaries with different internal diameter and surface electric field measurements. We found that the time between the plasma jet in first contact with the capillary tube surface and the subsequent penetration into the capillary tube spans several RF cycles due to electric fields at the plasma-tube interface below 4 kV cm –1 . These low electric fields require Penning ionization and/or stepwise ionization and hence a buildup of the metastable and electron density is required to achieve a sufficiently large ionization rate near the capillary tube inlet to enable penetration and propagation. Furthermore, it is found that the propagation of the argon jet into the capillary occurs during the positive half cycle of the RF waveform and is very similar to the propagation of the jet in surrounding air.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LLNL compiled first pages ordered by ascending B&R code

We aim to develop a fundamental understanding of materials dynamics (from {micro}s to ns) in systems where the required combination of spatial and temporal resolution can only be reached by the dynamic transmission electron microscope (DTEM). In this regime, the DTEM is capable of studying complex transient phenomena with several orders of magnitude time resolution advantage over any existing in-situ TEM. Using the unique in situ capabilities and the nanosecond time resolution of the DTEM, we seek to study complex transient phenomena associated with rapid processes in materials, such as active sites on nanoscale catalysts and the atomic level mechanisms and microstructural features for nucleation and growth associated with phase transformations in materials, specifically in martensite formation and crystallization reactions from the amorphous phase. We also will study the transient phase evolution in rapid solid-state reactions, such as those occurring in reactive multilayer foils (RMLF). Program Impact: The LLNL DTEM possesses unique capabilities for capturing time resolved images and diffraction patterns of rapidly evolving materials microstructure under strongly driven conditions. No other instrument in the world can capture images with <10 nm spatial resolution of interesting irreversible materials processes such as phase transformations, plasticity, or morphology changes with 15 ns time resolution. The development of this innovative capability requires the continuing collaboration of laser scientists, electron microscopists, and materials scientists experienced in time resolved observations of materials that exist with particularly relevant backgrounds at LLNL. The research team has made observations of materials processes that are possible by no other method, such as the rapid crystallization of thin film NiTi that identified a change in mechanism at high heating rates as compared to isothermal anneals through changes in nucleation and growth rates of the crystalline phase. The project is designed to reveal these fundamental processes and mechanisms in rapid microstructure evolution that form the foundation of understanding that is an integral part of the DOE-BES mission.

36 MATERIALS SCIENCE↗

The dilation aided single–line–of–sight x–ray camera for the National Ignition Facility: Characterization and fielding

Crystal x–ray imaging is commonly used in inertial confinement fusion and laser-plasma interaction applications as it has advantages compared to pinhole imaging, such as higher signal throughput, better achievable spatial resolution, and chromatic selection. Yet, currently used x–ray detectors are only able to obtain a single time resolved image per crystal. The dilation aided single–line–of–sight x–ray camera described here was designed for the National Ignition Facility (NIF) and combines two recent diagnostic developments, the pulse dilation principle used in the dilation x-ray imager and a ns–scale multi-frame camera that uses a hold and readout circuit for each pixel. This enables multiple images to be taken from a single–line–of–sight with high spatial and temporal resolution. Presently, the instrument can record two single–line–of–sight images with spatial and temporal resolution of 35 μm and down to 35 ps, respectively, with a planned upgrade doubling the number of images to four. Here we present the dilation aided single–line–of–sight camera for the NIF, including the x–ray characterization measurements obtained at the COMET laser, as well as the results from the initial timing shot on the NIF.

47 OTHER INSTRUMENTATION↗

Influence of spot size on propagation dynamics of laser-produced tin plasma

The plume dynamics in the presence of an ambient gas is very intriguing physics. The expansion of a laser-produced plasma in the presence of an ambient gas leads to internal plume structures, plume splitting, sharpening, confinement, etc. We investigated propagation dynamics of an expanding tin plume for various spot sizes using a fast visible plume imaging and Faraday cup diagnostic tools. Our results indicate that the sharpening of the plume depends strongly on the spot size. With a smaller spot size, the lateral expansion is found to be higher and the plume expansion is spherical while with a larger spot size the plume expansion is more cylindrical. Analysis of time resolved imaging also showed internal structures inside the plume.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fielding of a Time-Resolved Tomographic Diagnostic

A diagnostic instrument has been developed for the acquisition of high-speed time-resolved images at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed in order to create time histories of the electron beam. Four discrete optical subsystems view Cerenkov light generated at an x-ray target inside of a vacuum envelope. Each system employs cylindrical optics to image light in one direction and collapse light in the orthogonal direction. Each of the four systems images and collapses in unique axes, thereby capturing unique information. Light along the imaging axis is relayed via optical fiber to streak cameras. A computer is used to reconstruct the original image from the four optically collapsed images. Due to DARHT’s adverse environment, the instrument can be operated remotely to adjust optical parameters and contains a subsystem for remote calibration. The instrument was deployed and calibrated, and has been used to capture and reconstruct images. Matters of alignment, calibration, control, resolution, and adverse conditions will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fielding of a time-resolved tomographic diagnostic

A diagnostic instrument has been developed for the acquisition of high-speed time-resolved images at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed in order to create time histories of the electron beam. Four discrete optical subsystems view Cerenkov light generated at an X-ray target inside of a vacuum envelope. Each system employs cylindrical optics to image light in one direction and collapse light in the orthogonal direction. Each of the four systems images and collapses in unique axes, thereby capturing unique information. Light along the imaging axis is relayed via optical fiber to streak cameras. A computer is used to reconstruct the original image from the four optically collapsed images. Due to DARHT’s adverse environment, the instrument can be operated remotely to adjust optical parameters and contains a subsystem for remote calibration. The instrument was deployed and calibrated, and has been used to capture and reconstruct images. Matters of alignment, calibration, control, resolution, adverse conditions and maintenance will be discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interaction between pulsed discharge and radio frequency discharge burst at atmospheric pressure

The atmospheric pressure glow discharges (APGD) with dual excitations in terms of pulsed voltage and pulse-modulation radio frequency (rf) power are studied experimentally between two parallel plates electrodes. Pulse-modulation applied in rf APGD temporally separates the discharge into repetitive discharge bursts, between which the high voltage pulses are introduced to ignite sub-microsecond pulsed discharge. The discharge characteristics and spatio-temporal evolution are investigated by means of current voltage characteristics and time resolved imaging, which suggests that the introduced pulsed discharge assists the ignition of rf discharge burst and reduces the maintain voltage of rf discharge burst. Furtherly, the time instant of pulsed discharge between rf discharge bursts is manipulated to study the ignition dynamics of rf discharge burst.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution ptychographic imaging enabled by high-speed multi-pass scanning

As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh’s criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-Resolved In Situ Measurements During Rapid Alloy Solidification: Experimental Insight for Additive Manufacturing

In research and industrial environments, additive manufacturing (AM) of metals and alloys is becoming a pervasive technology, though significant challenges remain before widespread implementation of AM can be realized. In situ investigations of rapid alloy solidification with high spatial and temporal resolutions can provide unique experimental insight into microstructure evolution and kinetics that are relevant for AM processing. Hypoeutectic thin-film Al–Cu and Al–Si alloys were investigated using dynamic transmission electron microscopy to monitor pulsed-laser-induced rapid solidification across microsecond timescales. Solid–liquid interface velocities measured from time-resolved images revealed accelerating solidification fronts in both alloys. We observed microstructure evolution, solidification product, and presence of a morphological instability at the solid–liquid interface in the Al–4 at.%Cu alloy are related to the measured interface velocities and small differences in composition that affect the thermophysical properties of the alloys. These time-resolved in situ measurements can inform and validate predictive modeling efforts for AM.

36 MATERIALS SCIENCE↗

Data and Analysis from a Time-Resolved Tomographic Optical Beam Diagnostic

An optical tomographic diagnostic instrument developed for the acquisition of high-speed time-resolved images has been fielded at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed for the creation of time histories of electron-beam cross section through the collection of Cerenkov light. Four optical lines of sight optically collapse an image and relay projections via an optical fiber relay to recording instruments; a tomographic reconstruction algorithm creates the time history. Because the instrument may be operated in an adverse environment, it may be operated, adjusted, and calibrated remotely. The instrument was operated over the course of various activities during and after DARHT commissioning, and tomographic reconstructions reported verifiable beam characteristics. Results from the collected data and reconstructions and analysis of the data are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hohlraum x-ray preheat asymmetry measurement at the ICF capsule via Mo ball fluorescence imaging

In inertial confinement fusion, penetrating asymmetric hohlraum preheat radiation (>1.8 keV, which includes high temperature coronal M-band emission from laser spots) can lead to asymmetric ablation front and ablator–fuel interface hydrodynamic instability growth in the imploding capsule. First experiments to infer the preheat asymmetries at the capsule were performed on the National Ignition Facility for high density carbon (HDC) capsules in low density fill (0.3 mg/cc 4He) Au hohlraums by time resolved imaging of 2.3 keV fluorescence emission of a smaller Mo sphere placed inside the capsule. Measured Mo emission is pole hot (P2 > 0) since M-band is generated mainly by the outer laser beams as their irradiance at the hohlraum wall is 5× higher than for the inner beams. P2 has a large swing vs time, giving insight into the laser heated hohlraum dynamics. P4 asymmetry is small at the sphere due to efficient geometric smoothing of hohlraum P4 asymmetries at large hohlraum-to-capsule radii ratios. The asymmetry at the HDC capsule is inferred from the Mo emission asymmetry accounting for the Mo/HDC radius difference and HDC capsule opacity.

Dewald, E. L. (ORCID:0000000340546967)↗

Thermal behavior of single-crystal scintillators for high-speed X-ray imaging

Indirect detection of X-rays using single-crystal scintillators is a common approach for high-resolution X-ray imaging. With the high X-ray flux available from synchrotron sources and recent advances in high-speed visible-light cameras, these measurements are increasingly used to obtain time-resolved images of dynamic phenomena. The X-ray flux on the scintillator must, in many cases, be limited to avoid thermal damage and failure of the scintillator, which in turn limits the obtainable light levels from the scintillator. In this study, a transient one-dimensional numerical simulation of the temperature and stresses within three common scintillator crystals (YAG, LuAG and LSO) used for high-speed X-ray imaging is presented. Various conditions of thermal loading and convective cooling are also presented.

36 MATERIALS SCIENCE↗