Effect of Blade Cutout on Power Required by Helicopters Operating at High Tip-Speed Ratios

A numerical study was made of the effects of blade cutout on the power required by a sample helicopter rotor traveling at tip-speed ratios of 0.3, 0.4, and 0.5. The amount of cutout varied from 0 to 0.5 of the rotor radius and the calculations were carried out for a thrust coefficient-solidity ratio of 0.04. In these calculations the blade within the cutout radius was assumed to have zero chord. The effect of such cutout on profile-drag power ranged from almost no effect at a tip-speed ratio of 0.3 to as much as a 60 percent reduction at a tip-speed ratio of 0.5. Optimum cutout was about 0.3 of the rotor radius. Part of the large power reduction at a tip-speed ratio of 0.5 resulted from a reduction in tip-region stall, brought about by cutout. For tip-speed ratios greater than 0.3, cutout also effected a significant increase in the ability of the rotor to overcome helicopter parasite drag. It is thus seen that the adverse trends (at high tip-speed ratios) indicated by the uniform-chord theoretical charts are caused in large measure by the center portion of the rotor. The extent to which a modified-design rotor can actually be made more efficient at high speeds than a uniform-chord rotor will depend in practice on the degree of success in minimizing the blade plan form near the center and on special modifications in center-section profiles. A few suggestions and estimates in regard to such modifications are included herein.

Gessow, Alfred↗

A Novel Approach for Reducing Rotor Tip-Clearance Induced Noise in Turbofan Engines

Rotor tip-clearance induced noise, both in the form of rotor self noise and rotor-stator interaction noise , constitutes a significant component of total fan noise. Innovative yet cost effective techniques to suppress rotor-generated noise are, therefore, of foremost importance for improving the noise signature of turbofan engines. To that end, the feasibility of a passive porous treatment strategy to positively modify the tip-clearance flow field is addressed. The present study is focused on accurate viscous flow calculations of the baseline and the treated rotor flow fields. Detailed comparison between the computed baseline solution and experimental measurements shows excellent agreement. Tip-vortex structure, trajectory, strength, and other relevant aerodynamic quantities are extracted from the computed database. Extensive comparison between the untreated and treated tip-clearance flow fields is performed. The effectiveness of the porous treatment for altering the rotor-tip vortex flow field in general and reducing the intensity of the tip vortex, in particular, is demonstrated. In addition, the simulated flow field for the treated tip clearly shows that substantial reduction in the intensity of both the shear layer roll-up and boundary layer separation on the wall is achieved.

Khorrami, Mehdi R.↗

Compressor Stability Enhancement Using Discrete Tip Injection

Mass injection upstream of the tip of a high-speed axial compressor rotor is a stability enhancement approach known to be effective in suppressing small in tip-critical rotors. This process is examined in a transonic axial compressor rotor through experiments and time-averaged Navier-Stokes CFD simulations. Measurements and simulations for discrete injection are presented for a range of injection rates and distributions of injectors around the annulus. The simulations indicate that tip injection increases stability by unloading the rotor tip and that increasing injection velocity improves the effectiveness of tip injection. For the tested rotor, experimental results demonstrate that at 70 percent speed the stalling flow coefficient can be reduced by 30 percent using an injected mass- flow equivalent to 1 percent of the annulus flow. At design speed, the stalling flow coefficient was reduced by 6 percent using an injected mass-fiow equivalent to 2 percent of the annulus flow. The experiments show that stability enhancement is related to the mass-averaged axial velocity at the tip. For a given injected mass-flow, the mass-averaged axial velocity at the tip is increased by injecting flow over discrete portions of the circumference as opposed to full-annular injection. The implications of these results on the design of recirculating casing treatments and other methods to enhance stability will be discussed.

Suder, Kenneth L.↗

The possible involvement of root-cap mucilage in gravitropism and calcium movement across root tips of Allium cepa L

Roots of Allium cepa L. grown in aerated water elongate rapidly, but are not graviresponsive. These roots (1) possess extensive columella tissues comprised of cells containing numerous sedimented amyloplasts, (2) lack mucilage on their tips, and (3) are characterized by a weakly polar movement of calcium (Ca) across their tips. Placing roots in humid air correlates positively with the (1) onset of gravicurvature, (2) appearance of mucilage on tips of the roots, and (3) onset of the ability to transport Ca polarly to the lower side of the root tip. Gravicurvature of roots previously submerged in aerated water is more rapid when roots are oriented vertically for 1-2 h in humid air prior to being oriented horizontally. The more rapid gravicurvature of these roots correlates positively with the accumulation of mucilage at the tips of roots during the time the roots are oriented vertically. Therefore, the onset of gravicurvature and the ability of roots to transport Ca to the lower sides of their tips correlate positively with the presence of mucilage at their tips. These results suggest that mucilage may be important for the transport of Ca across root caps.

NASA Discipline Number 40-10↗

Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center

The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a bench top calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.

Woike, Mark R.↗

Quick-Connect Windowed Non-Stick Penetrator Tips for Rapid Sampling

Standard penetrator sampling systems were designed in order to allow for sampling via penetrators to produce a full set of sample acquisitions including volatile liquids, fine powders, and solid fragments. A gravity harpoon sampler has been designed with a removable tip and a quick coupling. The separation allows for sample handling and eliminates sample cross-contamination. Also, this design allows for multiple use of the penetrator body, which is the largest and heaviest part of the penetrator, while allowing for multiple changes of the light-mass, penetrator tip to avoid sample cross-contamination. The penetrator tip design has been improved by adding a spring trap to retain the sample, as well as a means for connecting to a quick coupling. Quick connect tips have been demonstrated in a sample handling carousel. The penetrator was released and rewound and the tips were released into a circular platter for rotation into instrument stations. The pyro-harpoon sampler was fabricated and tested with a NASA Standard Initiator (NSI) pyrotechnic charge. Initial tests collected cryogenic ice, but removal of the small pyro-harpoon from the ice was difficult. A brass metal sheath was then fitted over the harpoon tip, and removal from the ice was greatly alleviated by leaving the sheath in the ice. Quartz windows in the tips allow direct optical and spectral imaging and gas chromatography-mass spectrometer (GCMS) pyrolysis, and were found to survive impact. All systems were successfully tested by dropping into sand and into cryogenic ice.

Sherritt, Stewart↗

Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center

The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high-temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short-range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a benchtop calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.

Woike, Mark R.↗

Characterization and prediction of the electromechanical wear of contact tips during wire arc additive manufacturing of 316L stainless steel

Here, this study seeks to better understand the degradation of the contact tip with respect to WAAM for a 316L wire electrode as well as explore methods of monitoring the contact tip state from process data. The contact tip, a consumable component, positions the wire and serves as the electrical contact surface between the wire electrode and the welding power supply. The wear of the contact tip was characterized in terms of material loss and material contamination for a set of tips worn to discrete levels as measured by the amount of wire fed or arc time. Geometrical characterization found a 49% increase in the bore exit area at 180 meters of wire fed. Machine learning models were developed to predict the relative bore exit area of the contact tip from arc-based process data and a random forest classifier exhibited favorable performance with a cross-validated f1-score of 0.84. The regression architecture implemented a multi-layer perceptron with the ability to predict the relative exit area with an $R^2$ score of 0.75. Key features used in the prediction include the standard deviation of the voltage and the time between shorts.

Contact tip wear↗

A Parametric Study of Actuator Requirements for Active Turbine Tip Clearance Control of a Modern High Bypass Turbofan Engine

The efficiency of aircraft gas turbine engines is sensitive to the distance between the tips of its turbine blades and its shroud, which serves as its containment structure. Maintaining tighter clearance between these components has been shown to increase turbine efficiency, increase fuel efficiency, and reduce the turbine inlet temperature, and this correlates to a longer time-on-wing for the engine. Therefore, there is a desire to maintain a tight clearance in the turbine, which requires fast response active clearance control. Fast response active tip clearance control will require an actuator to modify the physical or effective tip clearance in the turbine. This paper evaluates the requirements of a generic active turbine tip clearance actuator for a modern commercial aircraft engine using the Commercial Modular Aero-Propulsion System Simulation 40k (C-MAPSS40k) software that has previously been integrated with a dynamic tip clearance model. A parametric study was performed in an attempt to evaluate requirements for control actuators in terms of bandwidth, rate limits, saturation limits, and deadband. Constraints on the weight of the actuation system and some considerations as to the force which the actuator must be capable of exerting and maintaining are also investigated. From the results, the relevant range of the evaluated actuator parameters can be extracted. Some additional discussion is provided on the challenges posed by the tip clearance control problem and the implications for future small core aircraft engines.

Turbine↗

Ultrafast laser triggered electron emission from ultrananocrystalline diamond pyramid tip cathode

Nitrogen-incorporated ultrananocrystalline diamond [(N)UNCD] pyramid tip cathode has been considered as a next-generation high peak current electron source for dielectric laser accelerators as well as other high peak current particle accelerator applications. In this work, we study non-linear photoemission from an (N)UNCD pyramid tip cathode using an ultrafast laser with the pulse length of 150 fs with the central wavelength of 800 nm in the peak intensity range of 10 9 –10 10 W/cm 2 . We demonstrated that as the incident laser intensity increases, the current emitted from the nano-tip first increases as a power function with an exponent of about 5 and then starts to roll over to an exponent of 3. This roll over is attributed to the Coulomb interaction between electrons emitted from the tip also known as the space charge. We also measured the photoemission electron energy spectra that show electrons with energies as high as ~10 eV. Based on the shape of the electron energy spectra, we conclude that the high-energy electrons are thermally emitted electrons due to ultrafast laser heating at the tip of the (N)UNCD pyramid tip cathode.

43 PARTICLE ACCELERATORS↗

Comment on “Tunneling-tip-induced collapse of the charge gap in the excitonic insulator Ta 2 NiSe 5 ”

In this study, we investigate the discrepancy between the estimate of Q. He [], who observed a remarkable collapse of the exciton gap in Ta 2 NiSe 5 due to the electrostatic field between the scanning tunneling microscope (STM) tip and the sample, and that of a recent angle-resolved photoemission spectroscopy investigation [C. Chen , ]. It is proposed that a critical factor contributing to this discrepancy is due to He 's assumption of a constant work function of the STM tip. This assumption led to an underestimation of the tip-induced electric field. Using a literature value for the sample work function, a more substantial electric field strength is obtained, which resolves the apparent conflict between the doping estimates of these two techniques. Furthermore, our findings highlight the importance of the STM tip condition, which can significantly impact the tip work function and, consequently, influence the doping estimation in experiments involving tip-induced electric fields. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Etching sharp tips from thin metallic wires for tuning-fork-based scanning probe microscopy

Sharp tips are critical for obtaining high resolution images in scanning probe microscopy (SPM), particularly in samples with large variations in topography. For tuning-fork-based SPM, such tips are commonly obtained by electrochemical etching of metallic wires (e.g., tungsten). Electrochemical etching of metallic wires is the preferred means of preparing tips for scanning tunneling microscopy (STM), and techniques for obtaining sharp tips have been investigated extensively. However, the requirements for STM and tuning-fork-based SPM are different. In particular, the wires used in STM are typically 250-500 μ m in diameter, while the wires used for tuning-fork-based SPM are usually an order of magnitude narrower in order to minimize loading of the tuning fork: 25-50 μ m and sometimes down to a few micrometers in diameter. Consequently, many of the recipes developed for etching thicker metallic wires for STM tips do not give optimal results for smaller diameter wires. The authors describe here a modification of the etching circuit of Ibe et al . that significantly improves the reproducibility and reliability of the etching process for thin wires, and discuss the parameters that affect the aspect ratio of produced tips.

42 ENGINEERING↗

In situ plasmonic tip preparation and validation techniques for scanning tunneling microscopy

Among the many parts constituting a scanning tunneling microscope, the metallic tip is the component that directly interacts with the specimen and plays a critical role in visualizing the physical quantity of interest. While tip materials such as W and Pt–Ir are commonly used for topographic imaging and their preparation is well-documented, the preparation of plasmonic materials such as Ag for tip-enhanced Raman spectroscopy is relatively less standardized. Furthermore, we present several in situ Ag tip preparation and validation techniques for the microscopist to use depending on their intended application, including atomic resolution imaging, scanning tunneling spectroscopy (STM), and tip-enhanced Raman spectro-microscopy in ultrahigh vacuum. Besides optical applications, these methods are not limited to Ag but also applicable to other STM tip materials.

47 OTHER INSTRUMENTATION↗

In Situ Measurement of Stress Corrosion Crack Tip Properties During Environmentally Induced Cracking in Stainless Steel 304L

The influence of the external cathodic area, stress intensity, and electrochemical polarization level on the resultant crack growth rate and crack tip pH and potential was studied for stainless steel 304L in a sodium chloride environment. Before testing, the validity of in situ crack tip property measurements using microprobes and drilled holes was supported through modeling efforts and confirmed with experimental observations. Here, it was found that increasing the R-ratio during corrosion fatigue increased the crack growth rate and decreased the measured crack tip pH of the 304L sample. Decreasing the electrochemical potential (i.e., cathodic polarization) of the bulk sample increased the crack tip pH and stopped measured crack extension under constant K conditions. Conversely, increasing the potential of the bulk sample decreased the crack tip pH and induced cracking under constant K conditions. Decreasing the cathodic area external to the crack increased the measured pH at the crack tip and decreased the crack growth rate under fatigue conditions. For the given configuration, environment, and alloy studied, fatigue crack growth is not sustained by cathodic reactions solely occurring in the crack wake and notch. These results have implications for the ability to predict atmospheric crack growth rates from laboratory, full immersion experiments.

corrosion fatigue↗

An experimental investigation of vortex stability, tip shapes, compressibility, and noise for hovering model rotors

Schlieren methods of flow visualization and hot-wire anemometry for velocity measurements were used to investigate the wakes generated by hovering model propellers and rotors. The research program was directed toward investigating (1) the stability of the tip vortex, (2) the effects produced by various tip shapes on performance and tip vortex characteristics, and (3) the shock formation and noise characteristics associated with various tip shapes. A free-wake analysis was also conducted for comparison with the vortex stability experimental results. Schlieren photographs showing wake asymmetry, interaction, and instability are presented along with a discussion of the effects produced by the number of blades, collective pitch, and tip speed. Two hot-wire anemometer techniques, used to measure the maximum circumferential velocity in the tip vortex, are discussed.

Tangler, J. L.↗

Analytic investigation of advancing blade drag reduction by tip modifications

Analytic techniques were applied to study the effect on the performance of the nonlifting advancing blade when the outboard 5% of the blade is modified to reduce drag. The tip modifications studied consisted of reducing airfoil thickness, sweepback, and planform taper. The reductions in instantaneous drag and torque were calculated for tip speed ratios from about 0.19 to 0.30, corresponding to advancing blade tip Mach numbers of 0.855 to 0.936, respectively. Approximations required in the analysis introduce uncertainties into the computed absolute values of drag and torque; however, the differences in the quantities should be a fairly reliable measure of the effect of changing tip geometry. For example, at the highest tip speed, instantaneous drag, and torque were reduced by 20% and 24%, respectively, for tip sweep of 40 deg on a blade using an NACA 0010 airfoil and by comparable amounts for 30-deg sweep on a blade having an NACA 0012 airfoil section. The present method should prove to be a useful, inexpensive technique for identifying promising configurations for additional study and testing.

Tauber, M. E.↗

Surface pressure measurements at two tips of a model helicopter rotor in hover

Surface pressures were measured near the tip of a hovering single-bladed model helicopter rotor with two tip shapes. The rotor had a constant-chord, untwisted blade with a square, flat tip which could be modified to a body-of-revolution tip. Pressure measurements were made on the blade surface along the chordwise direction at six radial stations outboard of the 94 percent blade radius. Data for each blade tip configuration were taken at blade collective pitch angles of 0, 6.18 and 11.4 degrees at a Reynolds number of 736,000 and a Mach number of 0.25 both based on tip speed. Chordwise pressure distributions and constant surface pressure contours are presented and discussed.

Gray, R. B.↗

Inherent spiral stability in a fixed wing aircraft by means of a simplified pneumatic wing tip control system

The concept of the lateralizer device is to sense the difference in wing tip static pressures (differential pressures being created by wing tip venturis) produced when any deviation from straight to level flight occurs. In a steady state turn the low slow wing tip experiences less venturi suction than the high fast wing tip. This signal activates the appropriate servos connected to the ailerons to produce a wing leveling restoring moment. If the wing is subjected to rolling velocities due to changes of the local angle of attack at the tip, the downgoing wing tip operates at a higher angle than the upgoing one. If with an increase in the angle of attack the signal is such that it increases the venturi pressure, then the servos are activated to produce the most negative signal to an upgoing aileron which results in a wing leveling restoring moment. In other words, any deviation from straight and level flight in either roll or yaw is exploited and the difference signal from the differential pressures activates the servo to effect or produce the necessary corrective action to null the signal.